Loading…
Loading…
Tender ID
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical HOSHIARPUR | HOSHIARPUR | HOSHIARPUR | PUNJAB | Accepted-Technical Accept |
| 2 | Accepted-Technical 60 ST NO 1 D GTB NAGAR NEAR KK ROAD BYPASS SHRI MUKTSAR SAHIB | Accepted-Technical Accept |
Tender Value
₹6.2 L
EMD Value
₹12,439
Closing Date
16 Jan 2026, 10:00 amClosed
Executive Engineer
Executive Engineer, Kandi Area Dam Maintennce Division No.1,DEPARTMENT OF WATER RESOURCES,PUNJAB Hoshiarpur.
Project Estimate for Laying UPVC Pipeline for Increasing CCA in Saleran village of Saleran Dam Hoshiarpur.
2026_WR_157069_1
155
Open Tender
Civil Works
Item Rate
Hoshiarpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
Yes
₹12,439
Yes
9 Apr 2026
1 Jan 2026
16 Jan 2026
1 Jan 2026
16 Jan 2026
1 Jan 2026
Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect. Earth work upto 1.5 m. Depth for. All classes of soil except rocky
Providing and filling sand grading as per specifications or fine grade around the various sizes of G.I. pipes in external work.
First class burnt brick work laid in cement sand mortar 1:4 in foundation and plinth
10mm thick Cement Plaster 1:3
Providing & fixing 200 mm alpha valve including carriage, rehandling, loading, unloading, testing, etc. complete in all respect as per PWD specifications or instructions of the engineer in charge.
Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications 200 mm i/d UPVC pipe of 2.5 Kgf. / sqcm
Providing & fixing 200mm Dia. Equal Tee (6 kg/cm2 pressure) conforming to IS codes with latest amendments if any at site of work including loading, unloading and rehandling if any complete in all respects as per design and P.W.D. specifications and instructions of engineer in charge.
Providing & fixing 200mm Dia. Short OR long Bend (90 Degree)(6 kg/cm2 pressure) conforming to IS codes with latest amendments if any at site of work including loading, unloading and rehandling if any complete in all respects as per design and P.W.D. specifications and instructions of engineer in charge.
Providing & fixing 200 mm PVC BENDS OF 45 DEGREE (6 kg/cm2 pressure) conforming to IS codes with latest amendments if any at site of work including loading, unloading and rehandling if any complete in all respects as per design and P.W.D. specifications and instructions of engineer in charge.
Providing & fixing 200 mm Tail end point 6kg with M.S./C.I. flange(6 kg/cm2 pressure) conforming to IS codes with latest amendments if any at site of work including loading, unloading and rehandling if any complete in all respects as per design and P.W.D. specifications and instructions of engineer in charge.
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer incharge)(A) Class PN-1.6 as per ISI (g)200mm i/d Sluice Valves flanged
Providing & fixing Single air valve ISI Marked as per IS-14845 including jointing all carriages complete C.I Single air valve Screwed(Size 50mm)
Providing & fixing 200x50 mm Dia. MS Service saddle (6 kg/cm2 pressure) conforming to IS codes with latest amendments if any at site of work including loading, unloading and rehandling if any complete in all respects as per design and P.W.D. specifications and instructions of engineer in charge.
Providing, laying, fixing, testing and commissioning of C Class heavy duty MS Pipe conforming to IndianStandard IS:1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nutsbolts, gasketsetc. fixing the pipe on the wall /ceiling with suitable clamp sandpainting with two or more coats of synthetice paint of required shade complete in all respects. (G)50mm internal diameter
Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department. Size 0.6 m. x 0.6 m.
Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department. Size 0.9 m. x 0.9 m.
Providing & fixing 200mm Dia. Socket (6 kg/cm2 pressure) conforming to IS codes with latest amendments if any at site of work including loading, unloading and rehandling if any complete in all respects as per design and P.W.D. specifications and instructions of engineer in charge.
stage.html
html • 0.03 MB
technical_318381.pdf
techsummary_318381.pdf
cancelled_1.pdf
pdf • 0.08 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.49 MB
BOQ_318381.xls
BOQ • 0.33 MB
Corrigendum31.pdf
PDF • 0.10 MB
BOQ_318381.rar
PDF • 0.09 MB
Corrigendum29.pdf
PDF • 0.09 MB
Corrigendum28.pdf
PDF • 0.09 MB
Corrigendum27.pdf
PDF • 0.09 MB
Corrigendum26saleran.pdf
PDF • 0.09 MB
Corrigendum25.pdf
PDF • 0.09 MB
Corrigendum24.pdf
PDF • 0.09 MB
Corrigendum23.pdf
PDF • 0.09 MB
Corrigendum22.pdf
PDF • 0.09 MB
Corrigendum21.pdf
PDF • 0.09 MB
Corrigendum20.pdf
PDF • 0.09 MB
Corrigendum19.pdf
PDF • 0.09 MB
Corrigendum18.pdf
PDF • 0.09 MB
Corrigendum17.pdf
PDF • 0.09 MB
Corrigendum16.pdf
PDF • 0.09 MB
Corrigendum15.pdf
PDF • 0.09 MB
Corrigendum14.pdf
PDF • 0.09 MB
Corrigendum13.pdf
PDF • 0.09 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .