Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.2 LAccepted-AOC 13 P N DOGRA MARKET GOLE MARKET UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹25.4 L+₹1.1 L (4.70%)Rejected-AOC | L2 | Rejected-AOC Rejected due to not being L1 | |
| 3 | L3₹25.7 L+₹1.5 L (6.00%)Rejected-AOC NEW HOSPITAL ROAD UDHAMPUR UDHAMPUR UDHAMPUR UDHAMPUR JAMMU KASHMIR 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L3 | Rejected-AOC Rejected due to not being L1 | |
| 4 | L4₹28.3 L+₹4.1 L (16.8%)Rejected-AOC | L4 | Rejected-AOC Rejected due to not being L1 | |
| 5 | L5₹29.2 L+₹5.0 L (20.6%)Rejected-AOC NOT AVAILABLE | L5 | Rejected-AOC Rejected due to not being L1 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
6 Sept 2023, 6:00 pmClosed
GE NORTH UDHAMPUR
GE NORTH UDHAMPUR
GE U(N) 43 2023 REPAIR TO EXTERNAL PLASTERING CHAJJA PARAPET RWP ROOF TREATMENT FOR OTM AND MD ACCN OF JNE UNDER AGE BR II OF GE (N) UDHAMPUR
2023_MES_613170_1
GE/U(N)-43 2023-24
Open Tender
Civil Works
Item Rate
180 days
GE NORTH UDHAMPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE NORTH UDHAMPUR
₹70,000
Yes
10 Oct 2023
10 Aug 2023
8 Sept 2023
10 Aug 2023
6 Sept 2023
23 Aug 2023
Amount
M&L for taking down cement plaster of any description on bricks, PCC block or stone walls, etc. Including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engr-in-Charge.
M&L for rendering 15 mm thick plaster in CM 1:4 mixed with WPC as per manufactures instructions in two layer (10mm+5mm). in patches in cement mortar in 1:4 on smooth face of brick work or concrete surfaces finishd even and smooth without using extra cement & with using integral water proofing compound complete all as specified and directed by Engr-in-Charge.
M&L for 5 mm thick rendering on fair faces of brick / concrete surfaces in cement mortar 1:3 and finished even and smooth complete all as specified & directed by Engr-in-Charge.
M&L for 10 mm thick rendering on fair faces of brick / concrete surfaces in cement mortar 1:6 and finished even and smooth complete all as specified & directed by Engr-in-Charge.
M&L for demolition of cement concrete un-reinforced of any description and in any position not otherwise specifically provided for cement concrete complete all as specified and directed by Engr-in-Charge.
M&L for providing 50 mm thick cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates as in plinth protection even and smooth with using extra cement complete all as specified and directed by Engr-in-Charge.
M&L for demolition of brick work or stone boulder masonery built in cement mortor including all quoins arches pillars etc complete all as specified & directed by Engr-in-Charge.
M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius butt in cm 1.6 complete all as specified and directed by Engr-in-Charge.
M&L for half brick work with sub class 'B' brick straight or curved on plan exc 6m mean radius but in cm 1:4 complete all as specified and directed by Engr-in-Charge.
M&L for two coat of cement base paint over newly plastered surfaces of wall over a coat of cement primer preparing surfaces complete all as specified and directed by Engr-in-Charge.
M&L for one coat of cement base paint over old plastered surfaces and preparing surfaces complete all as specified and directed by Engr-in-Charge.
M&L for preparation of new plaster surfaces of wall and applying two coat of exterior wheather coat emulsion on a coat of primer over a coat of 1mm thick putty complete all as specified and directed by Engr-in-Charge.
M&L for prepration of new decorated surfaces and applying two coats of distemper oil emulsion on walls over 1mm thick wall care putty coat of wall care putty complete all as specified & directed by Engr-in-Charge.
M&L for taking up or down steel tubing and connections, including cleaning for refixing or removal to store 20mm dia. complete all as specified and directed by Engr-in-Charge.
M&L for taking up or down steel tubing and connections, including cleaning for refixing or removal to store 25mm dia.complete all as specified and directed by Engr-in-Charge.
S&F steel water tubing medium grade galvanised with all fitting and fixed complete to wall and ceiling or laid in floors of 20mm bore complete all as specified and directed by Engr-in-Charge.
M&L for refixing Steel water tubing medium grade galvanised with all fitting and fixed complete to wall and ceiling or laid in floors of 20mm bore complete all as specified and directed by Engr-in-Charge.
M&L for steel water tubing medium grade galvanised with all fitting and fixed complete to wall and ceiling or laid in floors of 25mm bore complete all as specified and directed by Engr-in-Charge.
M&L for gun-metal, globe or gate valves,20mm bore dia, with iron wheel head, screwed both ends for iron pipe and fixed,complete all as specified and directed by Engr-in-Charge.
S&F in repair rotational moulded polyethlene water storage tanks three layered white in colour (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I,capacity of water tank 500 Ltr including dismantling & remove old tank from site all as specified & directed by Engr-in-Charge.
S&F in repair rotational moulded polyethlene water storage tanks three layered white in colour (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I,capacity of water tank1000 Ltr including dismantling & fixing only all as specified & directed by Engr-in-Charge
S&F ball brass valves 20mm , high pressure, with polyethene float & fly-nut complete, screwed for iron pipe or brass ferrule & fixed complete all as specified and directed by Engr-in-Charge.
S&F PVC (SWR). Pipe 110mm dia in any length with rubber ring joints, fixed to walls any height including taking down complete all as specified and directed by Engr-in-Charge.
S&F PVC (SWR). Pipe 75 mm dia in any length with rubber ring joints, fixed to walls any height including taking down complete all as specified and directed by Engr-in-Charge.
M&L for PVC (SWR) bends any radius, for 110mm bore of pipe, fixed with rubber ring joint, fixed in repair, complete all as specified and directed by Engr-in-Charge.
S&F repair stack clamps made out of 50mm x 5mm flat iron & 15 mm dia round iron steys, including bolts and nuts and securing ends of syays to wall or roof for 110mm bore,complete all as specified and directed by Engr-in-Charge.
M&L for demolition of cement concrete (un reinforced) as in roofs of existing water proofing treatment of any type and any thickness, complete all as specified and as directed by Engr-in-Charge.
M&L for roughing surfaces of old concrete surfaces by picking up, sweeping, cleaning and washing down with water to remove dust etc including taking down tarfelt and brushing neat cement slurry @ 3.50 Kg/ sqm including 10mm thick plastering in CM (1:3) finished even and smooth mixed with water proofing compound applying bituminous primer on roof surfaces @ 0.40 ltr/sqm and applying one coat of hot blown bitumen of grade 85/25 @ 1.20 kg/sqm and providing Atactic Polyoropylene polymer (APP) modified five layered prefabricated waterproofing membrane with thermal fusible properties on both side having minimum 3.00mm thick and unit weight not less thaan 4.00kg /sqm reinforced with non woven spun bonded polyester reinforcement < -2 C cold flexibility. The layer of the membreane shall be laid using butane torch and seailing all joints properly ,leaving no bare edgs or end of APP membrane and finishing the surfaces with trowel or otherwise to obtain a unifrom surfaces . The minimum side lap and end lap shall be kept at 75mm and 150mm respectively . The membrane shall be laid over a coat of bituminous primer @ 0.300 kg/ltr per sqm made by the same membrane manufacture after necessary surfaces preparatory works such as cleaning the surfaces throughly,shapping mouth of outlets including cutting grooves (50mm x50mm) in parapet and inserting edgs of membrane and mending goods damage by sand cement mortar (1:4) and shall be finished in all respect as per directed by Engr-in-Charge. Note :- The laying of the membrane shall be got done by authorized applicator of the membrane manufacturer.Before execution of the WPT the authorised applicator certificate for the engaged skilled labour by name shall be collected from contractor after that contractor allowed for execution of WPT and further the concern executives submitted the certificate along with payement.
M&L for applying aluminium paint two coats on roof surface complete complete all as specified and directed by Engr-in-Charge.
M&L for making benching with PCC (1:2:4) type B0 using WPC along side wall adjoining to roof in concave shape complete complete all as specified and directed by Engr-in-Charge.
M&L for 40 mm thick plain Cement concrete type B-0 ,1:2:4 (12.5 mm graded aggregate) in two layer (each 20mm) , in leveling course as in roof including chiken wire mesh size of 20mm x 20mm and thickness of mesh 0.91mm provide between the layer of PCC and even and smooth with false grooves at 450x450 mm complete all as specified and directed by Engr-in-Charge.
M&L for cement concrete tiles with cement and no pigment 25cmX25cm x22mm thick machine pressed set jointed and including 10mm screed bedding in CM 1:4 as pointed in neat cement slurry in flooring as cut and polished complete all as specified and directed by Engr-in-Charge.
M&L for taking down steel frames n.exc 1.5 sqm each with shutter (without taking off shutter from the frame) complete all as specified and directed by Engr-in-Charge.
M&L for taking down chowkats or frames with shutters (without taking off shutters from the frame) exc 1.5 square metre but n.exc 4 square metre each,complete all as specified and directed by Engr-in-Charge.
S&F steel window (box type) factory made with side hung shutters including pintol hinges, steel handles, steel peg stay and all locking arrangement complete with glazing bars dovetailed or welded including one shop coat of red oxide primer complete all as specified and directed by Engr-in-Charge. Note : i) The window shall be fabricated as per Drg No CEUZ/TD/1269/2008 Sheet 1/3 to 3/3. ii) MS fillets including the frame and glazing, shall be measured and paid separately.
Description all as per Srl Item No.34 here in before but without glazing bar complete complete all as specified and directed by Engr-in-Charge. Note : i) The window shall be fabricated as per Drg No CEUZ/TD/1269/2008 Sheet 1/3 to 3/3. ii) MS fillets icluding the frame and wire gauge shall be measured and paid separately.
S&F factory made mild steel ventilators box type with upper top hung shutters and bottom fixed type shutters including pintol hinges,steel peg stay and one shop coat of red oxide primer complete all as specified and directed by Engr-in-Charge. Note : i) The window shall be fabricated as per Drg No CEUZ/TD/1302/2009 Sheet 1/3 to 3/3
S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40 mm fixing with wooden/steel beads, complete all as specified and directed by Engr-in-Charge.
S&F 4mm thick sheet glass ordinary quality and glazing with beading in square n/exc 0.5 Sqm each pane fixing with wooden/steel beads, complete all as specified and directed by Engr-in-Charge.
S&F 4mm thick figured glass, pin head type and glazing with oil putty or wooden beads in squares n exc 0.5 sq. m in each pane complete all as specified and directed by Engr-in-Charge.
M&L for framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work including welding con- forming to Fe.290.Gde-E-165 complete all as specified and directed by Engr-in-Charge.
M&L for dismantling wrought iron or mild steel work of any description not otherwise provided forsteel works complete all as specified and directed by Engr-in-Charge.
M&L for preparation of new steel and iron surfaces exceeding 10cms width or girth and applying two coats of synthetic enamel paint over pre primered surface complete all as specified & directed by Engr-in-Charge.
M&L for preparation of new steel and iron surfaces n.exceeding 10cms width or girth and applying two coats of synthetic enamel paint over a coat of pink primier surface complete all as specified & directed by Engr-in-Charge.
M&L for reinforced cement concrete, 1:11/2:3, type A-1 (using 20 mm graded stone aggregate) as in slab supported on walls, beams and columns in floor, roofs, landings, balconies, canopies, shelves and like complete all as specified and directed by Engr-in-Charge.
M&L for form work to edges of concrete flats, treads, breaks in floors, window cills, floor and roof slabs and shelves, horizontal or sloping and similar work exc 5cm but not exc. 10cm wide complete all as specified and directed by Engr-in-Charge.
M&L for form work to soffits of suspended slabs such as floor slab,landings and similar work not exc 200mm thick in rough finish surfaces of concrete complete all as specified and directed by Engr-in-Charge.
M&L for demolition of cement concrete (reinforced) of pardis, roofs, floors, beams, staircase, landing, chajjas & wall manually/by mechanical means of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engr-in-Charge.
M&L for mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed by Engr-in-Charge.
M&L for mild steel bars 6 to 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed by Engr-in-Charge.
M&L for machine cut kota stone slab flooring18-20 mm thick over cement screed base laid 15 mm thick in Cement mortar 1:4 and jointed with grey cement slurry mixed with pigment to match theshade of the slab including rubbing and polishing complete all as specified & directed by Engr-in-Charge.
M&L for kota stone slab 18-20 mm thick in riser of steps, skirting, dado and pillar laid over 10 mm thick rendering in Cement mortar 1:3 as in skirting and jointed with grey cement slurry mixed with pigment to match theshade of the slab including rubbing and polishing complete all as specified & directed by Engr-in-Charge.
M&L for 25mm thick PCC 1:2:4 type B0 (using 12.5mm graded stone aggregate) as in floor/Stair case base of tiles/stones complete all as specified and directed by Engr-in-Charge.
M&L for dismantling cast iron or reinforced concrete drain pipes, any size up to 100mm bore, jointed in in cement mortor and taking out of trenches if required,complete all as specified and directed by Engr-in-Charge.
M&L for 150 mm x 150mm size Salt-glazed stoneware gully traps, square or round mouthed, type ‘P’ and jointed, ISI marked complete complete all as specified and directed by Engr-in-Charge.
S&F in repairs cast iron multi floor trap with grating to 75mm bore including jointing to waste pipe fixed in cement concrete 1:2:4 type B-1 complete all as specified & directed by Engr-in-Charge.
M&L for cast iron soil, sand cast waste and vent pipes,75mm dia in any length with or without ears with cement joints, laid in trenches or in floors in repair complete all as specified & directed by Engr-in-Charge.
M&L for sand Cast iron soil, waste and vent pipes,100mm dia in any length with or without ears with cement joints, fixed to wall in repair complete all as specified & directed by Engr-in-Charge.
Re-fixing only pipe execpet pipe Sand Cast iron soil, waste and vent pipes, 100mm dia in any length with or without ears with cement joints, fixed to wall in repair complete all as specified & directed by Engr-in-Charge.
M&L for sand Cast iron soil, waste and vent pipes,75mm dia in any length with or without ears with cement joints, fixed to wall in repair complete all as specified & directed by Engr-in-Charge.
M&L for re-fixing only pipe execpet pipe Sand Cast iron soil, waste and vent pipes,75mm dia in any length with or without ears with cement joints, fixed to wall in repaircomplete all as specified & directed by Engr-in-Charge.
S&F in repairs 75mm bore bends with access door(any radius) measured larger bore complete all as specified & directed by Engr-in-Charge.
M&L for re-Fixing only in repairs 75mm bore bends(any radius) measured larger bore complete all as specified & directed by Engr-in-Charge.
S&F in repairs 100mm bore bends/reducer (any radius) diminishing pieces or tapers (larger bore measured) complete all as specified & directed by Engr-in-Charge.
M&L for re-Fixing only in repairs 100mm bore bends(any radius) measured larger bore complete all as specified & directed by Engr-in-Charge.
S&F in repairs branch pieces 75mm bore Cast iron, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches fitted with oval accessed door,complete all as specified and directed by Engr-in-Charge.
S&F in repairs branch pieces 100mm bore Cast iron, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches fitted with oval accessed door,complete all as specified and directed by Engr-in-Charge.
S& F cast iron cowls of 75mm bore as in repair,complete all as specified and directed by Engr-in-Charge.
S& F cast iron cowls of 100mm bore as in repair,complete all as specified and directed by Engr-in-Charge.
M&L for plain cement concrete 1:4:8 type D-2 as in floors 75mm thick complete all as specified & directed by Engr-in-Charge.
M&L for machine pressed concrete interlocking paver block glossy finish, any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 grade with grey cement and pigment including 25 mm thick sand cusioning /filling under floors complete all as specified & directed by Engr-in-Charge.
M&L for 25 mm thick sand cusioning /filling under floors or complete all as specified & directed by Engr-in-Charge.
M&L for providing cement concrete 1:3:6 type C-0 using 12.5mm graded crushed stone aggregates for filling in the pressed steel door frame/hold fast complete all as specified & directed by Engr-in-Charge.
M&L for cutting holes in brick walls in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required exc half brick but n.exc one brick complete all as specified & directed by Engr-in-Charge.
S&F powder coated anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified.Including taking down existing shutters complete all as specified & directed by Engr-in-Charge.
S&F powder coated anodised aluminium Window and ventilator shutters ,side hung type without sash bars aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, anodised aluminium snap beading screws anodised aluminium fittings such as peg stays 150mm long (1No) hinges type B-21 100mm 2 No suitable handle 1no including taking down existing shutters complete all as specified & directed by Engr-in-Charge.
S&F powder coated anodised aluminium frame for doors windows ventilators with one or more rebates including joining cleat for fixing etc including taking down existing shutters complete all as specified & directed by Engr-in-Charge.
S&F 5mm thick tinted glass pin head type and glazing with oil putty in squares in exc .05 sqm in each pane complete all as specified & directed by Engr-in-Charge.
S&F aluminium extruded section hydraulically door closer regulated designation no-1 universal type suitable for door shutter upto 700mm in width and of weight not more than 35 kg complete all as specified & directed by Engr-in-Charge.
M/S IMTESH BHAT
MAHAJAN TRADING CO
paras ram pachiala
DURGA CONSTRUCTION CO
RUDRABHISHEK CONSTRUCTIONS
KUMAR CONSTRUCTION CO
M/S PARDEEP KUMAR
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .