| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.4 LAccepted-AOC 12 1 FERRIGHAT ROAD P O BHATPARA DIST NORTH 24 PGS WEST BENGAL PIN 743123 | BHATPARA | NORTH 24 PARGANAS | WEST BENGAL | 743123 | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹5.4 L+₹1,750 (0.32%)Rejected-Finance 19B PANKAJINI CHATTERJEE ROAD CHARU MARKET KOLKATA WEST BENGAL 700033 UDYAM WB 10 0047115 | KOLKATA | WEST BENGAL | 700033 | L2 | Rejected-Finance 2nd lowest bidder | |
| 3 | L3₹5.5 L+₹8,610 (1.59%)Rejected-Finance BASUDEBPUR BELKHALI HOWRAH PIN 711 322 | HOWRAH | HOWRAH | WEST BENGAL | 711322 | L3 | Rejected-Finance 3rd lowest bidder |
| Sl No | Description | Qty | Unit | Computer Gallery L3 | BALAJI FIRE PROTECTION SYSTEMS L2 | Creative Projects L1 |
|---|---|---|---|---|---|---|
| 1.00 | Supply, installation, testing & commissioning of EN Standard, VDS /UL approved Addressable Multi-Sensor Detector (optical smoke as well as heat) with inbuilt / equal number of additional Isolator for each detector and integral LED status indicator with 360 degree viewing angle. Detector shall communicate 3 danger levels for differentiated alarm activation and high tolerance to dust,dirt, temperature fluctuations and air currents. Detector should have unquie address for communication and assigned through panel with Mounting Base as required.
(Approved Make : Siemens Cerberus Pro / Bosch/Honeywell/ Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / GST ) | 60 | Nos | 3,450 ₹2,07,000 | 3,300 ₹1,98,000 Lowest | 3,465 ₹2,07,900 |
| 2.00 | Supply, installation, testing & commissioning of EN Standard, VDS approved Inteliigent addressable manual call point with inbuilt / equal number of additional Isolator for each manual call point suitable for flush or surface mounting, call point shall include test key feature without removing the glass with extra acceesories as required. (Approved Make : Siemens Cerberus Pro / Bosch/Honeywell/ Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / GST/ ) | 6 | Nos | 2,650 ₹15,900 Lowest | 2,650 ₹15,900 Lowest | 2,800 ₹16,800 |
| 3.00 | Supply, installation, testing & commissioning of EN Standard, VDS approved Inteliigent addressable loop powered sounder cum beacon with base, inbuilt / equal number of additional Isolator for each sounder, able to provide an o/p of minimum 80dBA at 1m, peak light o/p of at least 10cd and shall have minimum 9 programmable tones, 3 volume settings selectable from the panel and fully synchronized with other sounders and shall have the ability to switch between one tone for alert and one tone for evacuation.
(Approved Make : Siemens Cerberus Pro / Bosch/Honeywell/ Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / GST/ ) | 6 | Nos | 4,250 ₹25,500 Lowest | 4,500 ₹27,000 | 5,200 ₹31,200 |
| 4.00 | Supply, installation, testing & commissioning of Response Indicator with all accessories.
(Approved Make : Siemens Cerberus Pro / Bosch/Honeywell/ Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / GST ) | 10 | Nos | 40 ₹400 | 110 ₹1,100 | 20 ₹200 Lowest |
| 5.00 | Supply & Laying of 2 Core 1.5 sq.mm FRLS screen shielded copper Cable (Make. Finolex / Havells / Polycab) in prelaid PVC rigid conduit pipe. | 1,080 | RM | 47 ₹50,760 | 65 ₹70,200 | 40 ₹43,200 Lowest |
| 6.00 | Supply & Drawing 20 mm NB PVC rigid conduit pipe (Make: Precisson/polycab) on wall incl necy. Bend, elbow etc. | 1,050 | RM | 26 ₹27,300 | 24 ₹25,200 | 19 ₹19,950 Lowest |
| 7.00 | Supply, Installation, Testing & Commissioning of Microprocessor based Intelligent, addressable expandable and fully networkable fire alarm control panel ( VDS / UL approved ) suitable for the devices as stated in the previous items of this BOQ along with 20% spare capacity with each loop loading not exceeding 80% of the full capacity of detectors and devices taken together, complying to IS 2189:2008 or its latest amendments, and with minimum 600 character alpha - numeric liquid crystal display. The panel shall be soft addressable type and shall be able to give pin point location of all fire/ fault conditions. Further, the panel must be able to automatically switch off respective control switches whenever any alarm is triggered. The Panel should be able to store sufficient numbers of log events in its Memory as per recommended standards.
The FACP shall be capable of being networked (future expansion) with other similar FACP located at different part of the premises through single RS 485 bus. The FACP shall have provision for interfacing with the public address system, remote computer and BMS interface. The system must be preloaded with licensed software.
(Approved Make : Siemens Cerberus Pro / Honeywell/ Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / GST ) | 1 | Item | 2,22,000 ₹2,22,000 | 2,05,000 ₹2,05,000 Lowest | 2,21,000 ₹2,21,000 |
| 8.00NOTE :- 1) The Fire Alarm system shall comply with latest requirements of -- (i) National Fire Protection Association (NFPA) Standards, (ii) IS 2189 , (iii) NFPA 70 National Electric Code, (iv) NFPA 72 National Fire Alarm & Signaling Code , (v) Local Statutory Regulations , (vi) Manufacturer Recommendation. vii) System should be integrated with the components like FACP, Detectors, MCP, Hooter, Monitor Module, Relay Module, etc. and all these components should be of same brand. | ||||||
| 9.00TESTS :- 1) The system shall be tested and commissioned by a qualified competent, trained engineer or technician authorized by the manufacturer of the fire alarm equipment to technically supervise and participate during all of the adjustments and tests for the system. 2) Before energizing the cables and wires, inspection and check for correct connections, and test for short circuits, ground faults, continuity, and insulation and other tests as per applicable Indian/International standards must be done. | ||||||
| 10.00TERMS & CONDITIONS :- | ||||||
Tender Value
₹5.5 L
EMD Value
₹11,000
Closing Date
14 May 2025, 12:00 pmClosed
Exe.Engr.-I, Kol. South Health El. Divn. P.W.Dte
75 D H Road Kidderpore Kol_75
Emergent thorough renovation work of Electrical Installations , Air-Conditioning Systems and SITC of FDA Systems and online UPS System at Bio-Chemistry Lab and Ancillary areas of IOP Office Building, IOP-COE, Kolkata-25-SITC of FDA System
2025_WBPWD_840363_1
WBPWD/EE-I/KSHED/Q11/25-26
Open Tender
FIRE FIGHTING ORG
Item Rate
30 days
Kolkata
Please refer Tender documents.
4 documents required · 4 mandatory
₹11,000
O/o Exe.Engr., Kol. South Health El. Divn. P.W.Dte
9 Sept 2026
29 Apr 2025
16 May 2025
29 Apr 2025
14 May 2025
7 May 2025
6 May 2025
Amount
Supply, installation, testing & commissioning of EN Standard, VDS /UL approved Addressable Multi-Sensor Detector (optical smoke as well as heat) with inbuilt / equal number of additional Isolator for each detector and integral LED status indicator with 360 degree viewing angle. Detector shall communicate 3 danger levels for differentiated alarm activation and high tolerance to dust,dirt, temperature fluctuations and air currents. Detector should have unquie address for communication and assigned through panel with Mounting Base as required. (Approved Make : Siemens Cerberus Pro / Bosch/Honeywell/ Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / GST )
Supply, installation, testing & commissioning of EN Standard, VDS approved Inteliigent addressable manual call point with inbuilt / equal number of additional Isolator for each manual call point suitable for flush or surface mounting, call point shall include test key feature without removing the glass with extra acceesories as required. (Approved Make : Siemens Cerberus Pro / Bosch/Honeywell/ Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / GST/ )
Supply, installation, testing & commissioning of Response Indicator with all accessories. (Approved Make : Siemens Cerberus Pro / Bosch/Honeywell/ Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / GST )
Supply & Laying of 2 Core 1.5 sq.mm FRLS screen shielded copper Cable (Make. Finolex / Havells / Polycab) in prelaid PVC rigid conduit pipe.
Supply & Drawing 20 mm NB PVC rigid conduit pipe (Make: Precisson/polycab) on wall incl necy. Bend, elbow etc.
Supply, Installation, Testing & Commissioning of Microprocessor based Intelligent, addressable expandable and fully networkable fire alarm control panel ( VDS / UL approved ) suitable for the devices as stated in the previous items of this BOQ along with 20% spare capacity with each loop loading not exceeding 80% of the full capacity of detectors and devices taken together, complying to IS 2189:2008 or its latest amendments, and with minimum 600 character alpha - numeric liquid crystal display. The panel shall be soft addressable type and shall be able to give pin point location of all fire/ fault conditions. Further, the panel must be able to automatically switch off respective control switches whenever any alarm is triggered. The Panel should be able to store sufficient numbers of log events in its Memory as per recommended standards. The FACP shall be capable of being networked (future expansion) with other similar FACP located at different part of the premises through single RS 485 bus. The FACP shall have provision for interfacing with the public address system, remote computer and BMS interface. The system must be preloaded with licensed software. (Approved Make : Siemens Cerberus Pro / Honeywell/ Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / GST )
NOTE :- 1) The Fire Alarm system shall comply with latest requirements of -- (i) National Fire Protection Association (NFPA) Standards, (ii) IS 2189 , (iii) NFPA 70 National Electric Code, (iv) NFPA 72 National Fire Alarm & Signaling Code , (v) Local Statutory Regulations , (vi) Manufacturer Recommendation. vii) System should be integrated with the components like FACP, Detectors, MCP, Hooter, Monitor Module, Relay Module, etc. and all these components should be of same brand.
TESTS :- 1) The system shall be tested and commissioned by a qualified competent, trained engineer or technician authorized by the manufacturer of the fire alarm equipment to technically supervise and participate during all of the adjustments and tests for the system. 2) Before energizing the cables and wires, inspection and check for correct connections, and test for short circuits, ground faults, continuity, and insulation and other tests as per applicable Indian/International standards must be done.
TERMS & CONDITIONS :-
The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them. Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/ submission of bill. If any refurbished material is supplied and installed, penal action will be taken as per existing rules
Defect Liabibility Period 1 (One) year
Make & model of each and every material to be approved by EIC
BALAJI FIRE PROTECTION SYSTEMS (BID ID -6399381)
Computer Gallery (BID ID -6387578)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .