Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 LAdmitted-Finance 4264 GALI SHAHTARA AJMERI GATE DELHI DELHI 110006 | NORTH DELHI | DELHI | 110006 | L1 | Admitted-Finance | |
| 2 | L2₹2.2 L+₹39,117 (21.4%)Admitted-Finance | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | paramount systems L1 | V.K. ENTERPRISES L2 |
|---|---|---|---|---|---|
| 1.01 | Shutting off the main suction valves located both outside and inside the premises, and closing the sluice valves of the pump set after taking the necessary shutdown, wherever required. The work shall include deployment of all necessary safety measures, tools, tackles and equipment for safe and proper operation/closure of the valves, as per site requirements and the directions of the Engineer-in-Charge. | 1 | Job | 5,000 ₹5,900 Lowest | 10,000 ₹11,800 |
| 1.02 | Tracing and locating the source of leakage by excavating the area where the underground pipeline is laid, including manual excavation, breaking of CC flooring and/or wall wherever required, particularly at the point where the common header emerges from the pump area, as per site requirements. The work shall be carried out with all necessary safety precautions and measures. | 1 | Job | 5,000 ₹5,900 Lowest | 10,000 ₹11,800 |
| 1.03 | Safety arrangement like Air Face Mask, Helmet, Gum Boots, Hand Gloves, Safety Belts, First Aid Box, Litmus Paper, etc. arranged by the firm for safe working of men and machinery at site. All precautions are to be taken to save men and material. | 1 | Job | 5,000 ₹5,900 Lowest | 15,000 ₹17,700 |
| 1.04 | Dismantling of existing damaged 300 mm dia. Common header line and allied accessories from the pump set with the help of heavy manual labour and electric welding set and gas cutter using proper logistics arrangements i.e. special tripod for holding the dismantled pipe and other accessories. | 1 | Job | 5,000 ₹5,900 Lowest | 10,000 ₹11,800 |
| 1.05 | Supply of 300 mm dia. M.S. pipe having thickness 8 mm duly painted with black bituminous anticorrosive paint. Make - TATA/ Jindal/ ISI/ Any other DJB Approved | 10 | Mtr. | 50,000 ₹59,000 Lowest | 55,000 ₹64,900 |
| 1.06 | Supply of 300mm dia. M.S Bend of 90 degree as per site requirement duly painted with black bituminous anticorrosive paint. Make - TATA/ Jindal/ ISI/ Any other DJB Approved | 1 | No. | 5,000 ₹5,900 Lowest | 10,000 ₹11,800 |
| 1.07 | Supply of 12mm thick M.S flange for 300 mm dia. M.S pipe. | 8 | Nos. | 24,000 ₹28,320 Lowest | 28,000 ₹33,040 |
| 1.08 | S/o Rubber insertion 75 % Neoprene (1.5 mm to 25 mm) jointing sheet conforming IS 638/79 with ISI mark 1.5 mm thick Make:- Jyoti or any other make approved by DJB | 20 | Kg | 7,000 ₹8,260 Lowest | 9,000 ₹10,620 |
| 1.09 | Supply of M.S Nut bolts washer as per site requirement. | 25 | Kg | 2,500 ₹2,950 Lowest | 2,750 ₹3,245 |
| 1.10 | Replacement of line by welding the flanges at both ends of the M.S pipe of 300 mm dia by cutting , welding, grinding etc. and fixing the same in proper alignment along with the existing holding arrangement with the help of heavy manual labor, nut/ bolts etc. complete in all respect as per site requirement | 1 | Job | 21,100 ₹24,898 | 18,000 ₹21,240 Lowest |
Tender Value
Refer Docs
EMD Value
₹4,800
Closing Date
15 Sept 2026, 3:15 pmClosed
Executive Engineer (EnM) M-8
Office of the Executive Engineer (EnM) M-8 Nangloi Phase-III, Near Maharaja Surajmal Stadium Metro Station New Delhi-110041.
Repairing of leakage in common header delivery line of 300 mm dia at Majra Nala Online Booster in AC-10. (Re-invite).
2026_DJB_298142_1
NIT No.12 /EE(EnM)M-8/2026-27 Item 20
Open Tender
Civil Works
Works
30 days
Nangloi
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Account No SB 50448339804
₹4,800
Yes
3 Oct 2026
8 Sept 2026
15 Sept 2026
8 Sept 2026
15 Sept 2026
8 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Shutting off the main suction valves located both outside and inside the premises, and closing the sluice valves of the pump set after taking the necessary shutdown, wherever required. The work shall include deployment of all necessary safety measures, tools, tackles and equipment for safe and proper operation/closure of the valves, as per site requirements and the directions of the Engineer-in-Charge. | 1 | Job | 80 | ₹80 |
| 1.02 | Tracing and locating the source of leakage by excavating the area where the underground pipeline is laid, including manual excavation, breaking of CC flooring and/or wall wherever required, particularly at the point where the common header emerges from the pump area, as per site requirements. The work shall be carried out with all necessary safety precautions and measures. | 1 | Job | 80 | ₹80 |
| 1.03 | Safety arrangement like Air Face Mask, Helmet, Gum Boots, Hand Gloves, Safety Belts, First Aid Box, Litmus Paper, etc. arranged by the firm for safe working of men and machinery at site. All precautions are to be taken to save men and material. | 1 | Job | - | - |
| 1.04 | Dismantling of existing damaged 300 mm dia. Common header line and allied accessories from the pump set with the help of heavy manual labour and electric welding set and gas cutter using proper logistics arrangements i.e. special tripod for holding the dismantled pipe and other accessories. | 1 | Job | - | - |
| 1.05 | Supply of 300 mm dia. M.S. pipe having thickness 8 mm duly painted with black bituminous anticorrosive paint. Make - TATA/ Jindal/ ISI/ Any other DJB Approved | 10 | Mtr. | - | - |
| 1.06 | Supply of 300mm dia. M.S Bend of 90 degree as per site requirement duly painted with black bituminous anticorrosive paint. Make - TATA/ Jindal/ ISI/ Any other DJB Approved | 1 | No. | - | - |
| 1.07 | Supply of 12mm thick M.S flange for 300 mm dia. M.S pipe. | 8 | Nos. | - | - |
| 1.08 | S/o Rubber insertion 75 % Neoprene (1.5 mm to 25 mm) jointing sheet conforming IS 638/79 with ISI mark 1.5 mm thick Make:- Jyoti or any other make approved by DJB | 20 | Kg | - | - |
| 1.09 | Supply of M.S Nut bolts washer as per site requirement. | 25 | Kg | - | - |
| 1.1 | Replacement of line by welding the flanges at both ends of the M.S pipe of 300 mm dia by cutting , welding, grinding etc. and fixing the same in proper alignment along with the existing holding arrangement with the help of heavy manual labor, nut/ bolts etc. complete in all respect as per site requirement | 1 | Job | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.14 MB
BOQ_397426.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .