Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.9 CrAccepted-AOC | ₹6.9 Cr | L1 | Accepted-AOC Accepted |
| 2 | L2₹7.2 Cr+₹33.5 L (4.85%)Rejected-AOC | ₹7.2 Cr+₹33.5 L (4.85%) | L2 | Rejected-AOC Rejected |
| 3 | L3₹7.3 Cr+₹36.8 L (5.32%)Rejected-AOC BANSAL COTTAGE BADRI NAGAR TEH PAONTA SAHIB SIRMAUR | SIRMAUR | HIMACHAL PRADESH | 173025 | ₹7.3 Cr+₹36.8 L (5.32%) | L3 | Rejected-AOC Rejected |
Tender Value
₹6.8 Cr
EMD Value
₹6.8 L
Closing Date
21 Sept 2020, 11:00 amClosed
Executive Engineer
JSV Division Rohru
SH Site development for all Civil Structures C O Anckor block for R main C O Sump well at node 1 2 4 23 000 Litrs Cap C O Sump well at node 3 4 03 000 Litrs Cap C O Sump well at node 5 2 24,000 Litrs Cap C O Sump well at node 6 2 14 0
2020_HPIPH_40379_1
IPH-RD-E-Tender/2020-6190-6217
Open Tender
Civil Works - Others
Item Rate
365 days
Rohru Town
Tender Document
8 documents required · 8 mandatory
₹2,500
Yes
EE Rohru
₹6.8 L
Yes
Engineer in Chief
24 Mar 2021
7 Sept 2020
22 Sept 2020
7 Sept 2020
21 Sept 2020
7 Sept 2020
14 Sept 2020
Amount
Cutting in earth work and disposal of excavted earth all kind of soil with in all leads and lifts as per the direction of the Engineer in Charge P&J work.
Excavation in foundations , trenches etc., in earth work , lift up to 1.50 metres. Stacking the eacavated soil not more than 3 metres clear from the edge of the excavation and then returning the stacked soil in 15 cm. (fifteen centimetres) layers , when required in to plinth and sides of foundations etc., conslolidating each of the disposited layer by ramming and watering and then disposing off all excavated soil as directed with in the load of 20 mtrs. Pick and Jumper work etc. complete as per the direction of the Engineer - in - Charge.
Execavation in foundation digging well in dry execavation from ground level up to the level which well curb is placed,including depositing spoils in 20 mtrs. Radius for filling space out side the well after completion from N.S level to 1.5 mtrs. Depth in pick & jumper work 50% each with in all leads and lifts and as directed by the Engineer-in-charge.
Wet well sinking in gravel including all pumping shoring etc. with in all lead and lifts and as directed by the Engineer-in-charge.
i) From spring level to 3 mtrs.
ii) From 3 mtrs. To 6 mtrs.
iii) From 6 mtrs. To 9 mtrs.
Lowering steel well curb in the pit and assembling in position etc. with in all lead and lifts and as directed by the Engineer-in-charge.
I ) When depth is upto 3 mtrs. From ground.
II ) When depth is more than 3 mtrs.
Providing 200mm wide cost iron rungs with chequirred ribbed non slip surfaces including fixing in main holes with 200mmx20mmx100mm cement concrete 1:3:6 (1cement 3sand 6 graded stone 20mm nominal size with in all leads and lifts and as directed by the Engineer-in-charge.
Square rubble masonary coursed with hard stone of approved quality in foundation and plinth in retaing walls/ Breast walls including raking out joints in cement mortar 1:4 (1cement 4 sand) within all leads and lifts and as directed by the Engineer-in-charge.
20mm cement concrete topping 1:2 to 3(1cement :2 to 3 stone aggrigate of size 4.75mm and below by volume) laid over and finished monolithic with base concrete within all leads and lifts and as directed by the Engineer-in- charge.
Providing and laying cement concrete 1:3:6 (1cement: 3 sand: 6 graded stone aggregate 40mm( Forty millimeter nominal size) and curing complete excluding cost of from work in foundation and plinth with in all leads & lifts as per entire satisfication of Engineer-in-Charge.
Providing from work steel plates 3.15 mm thick welded with angle iron in frame 30x30x5 mm so as to give a fair finish i/c centering, shuttering, strutting and propping etc. with wooded battens & ballies, height of propping and centring below supporting floor to ceilling not exceeding 4 meters and removal of the same for in situ reinforced concrete and plain concrete work with in all leads aand lifts as per the direction of the Engineer in Charge.
i) Vertical surfaces such as walls (any thickness) partitions and the like including attached pillasters, buttress, plinth and string couress and the like.
ii) Flat surfaces such as soffits and suspended floors, roofs landing and the like: Floors etc up to 200 mm in thickness .
iii) Edge of slab and breaks in floors and wall under20cm wide within all leads and lifts.
iv) Foundation footing bases of column and mass concrete.
v) Column, pillar & poat upto floor two level square, rectangular and polygonal in plan.
vi) Stair cases (Except spiral stair cases) excluding landing i/c preparation of surface.
vii) Beams, cantilevers, Girders & lintels sides and siffits of beams, hounching cantilever girder not exceeding 1 mtr. Depth.
viii) Sloping and bettering surfaces I/c folding plates where inclination to horizontal plane not exceed 30 degrees.
vix) Arches upto 6.00 mts.span
Providing & laying in trenches GMS/MS Tubes (L/M class) tube fitting (Earth work in trenches to be measured & paid for separately)
50mm dia.
65mm dia.
Providing & fixing CI Sluice valve (with hand wheel) as per IS : 780-1984 class-I upto 300 mm dia.(i/c brass spindle & as per 2906-1984 class-II for dia.> 300 mm) complete with bolts nuts,rubber insertion etc.,(the tail piece if required shall be measured & paid for separatly)
50 mm dia.
65 mm dia
Prov. & fixing SFRC Man hole cover with frame having frames size of 560 mm internal dia.should not be less than 58 kg
Providing and laying cement concrete 1:1.5:3(1cement:1.5 approved sand:3approved graded stone agg. 20mm nominal size) & curing complete excluding cost of form work in foundation and plinth:
i) Foundation and plinth (bed) with in all leads and lifts.
ii) Column, pillar & poat upto floor two level.
iii Suspended Floor roofs, landing and shelves and their support balconies, beams, girders, bressumers and contilever up to floor two level with in all leads and lifts as per the direction of the Engineer - in - Charge.
iv) Stair cases (except spiral stair cases) excluding landing i/c preparation of surface.
Providing and laying cement concrete 1:1:2 (1cement :1Sand: 2 graded stone aggregate 20 mm N/S) and curing complete excluding cost of form work and reinforcement for Rainforced concrete work in:-
i) Foundation and plinth (bed) with in all leads and lifts.
ii) Column, pillar & poat upto floor two level.
(iii) Wall (any thickness but not less than 0.1 m thickness) attached pilasters,buttresses, plinth and string courses etc. from top of foundation level up to floor two level with in all leads and lifts as per the direction of the Engineer - in - Charge.
iv) Suspended Floor roofs, landing and shelves and their support balconies, beams, girders, bressumers and contilever up to floor two level with in all leads and lifts as per the direction of the Engineer - in - Charge.
Providing mild steel/ tor steel reinfircement for rainforced concrete work I/C bending, binding and placing in position complete upto floor two level with in all leads and lifts as per the direction of the Engineer in Charge.
Providing and laying cement concrete 1:2:4 (1cement :2 Sand: 4 graded stone aggregate 20 mm (Twenty millimeter nominal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work in : Suspended Floor roofs, landing and shelves and their support balconies, beams, girders, bressumers and contilever up to floor two level with in all leads and lifts as per the direction of the Engineer - in - Charge.
(ii) Arches upto floor two level.
Providing and laying (pours) No fine concrete 1:4 (1Cement : 4 graded stone Agg. 40mm and above and curing complete with weep hole or pours etc. with in all leads and lifts as per the direction of the Engineer in Charge.
R/R masonary/polygone rubble masonry (uncoursed/brought to course) with hard stone of approved quality in foundation & plinth including levelling up with cement concrete 1:6:12 (1cement:6sand:12aggrigate 20mm nominal size)at plinth level in CM 1:6 (1cement:6sand) within all leads and lifts as per the directions of the Engineer in charge.
Boulder/Stone filling behind retaing wall & crate wall within all leads and lifts and as directed by the Engineer-in-charge.
Steel work in single sections including cutting hoisting fixing in position and applying a priming coat of red lead paint in R.S. joists, channels, angles, Tees, with in all leads and lifts as directed by the Engineer -In-charge
Providing in RCC work smooth finishing of the exposed surface with cement mortor1:3 (1cement :3 sand )with in all leads and lifts as per direction of the Engineer in Charge.
10mm cement plastering in single coat on fair side of brick/concrete wall for internal plastering upto floor two level i/c arrises internal angles, chamfers and rounded angles not exceeding 80mm in girth and finished even and smooth in cement mortar 1:3 (1cement : 3 Sand ) with in all leads and lifts as per direction of the Engineer in Charge.
White washing with lime on undecorated wall surfaces(two coats) to give an even shade I/c thoroughly brooming the surface to remove all dust dirt & other foreign matter. with in all leads and lifts as per the direction of the Engineer in charge.
Half Brick masonary using common burnt clay building bricks above plinth upto floor two level in cm 1:4(1cement:4sand)conventiohal brick first class within all leads and lifts and as directed by the Engineer-in-charge.
Providing and fixing pressed steel door, frames, manufactured from comercial mild steel sheet of 1.25 mm thickness including hinges jump block Jamb, beed, and if required angle threshold of mil steel angle of section 50x25mm or base ties of 1.25mm pressed mild steel welded or regidly fixed together by machanical means adjustable lugs with split and tails to each Jamb i/c steel but things 2.5mm thick with guards lock strike plate and shock as specified and applying a coat of applying steel primer after pretreatment of the surfaces directed by the Engineer-in-charge
Profile A
Profile B
Profile C
Providing and fixing Pannelled and glazed shutters for doors windows and clear storey windows including bright finish black enamel led iron butt hinges with necessary screws 40mm thick: 2nd class deodar wood.
Providing and Fixing wire gause shutter using MS wire gause if IS gause designation 85 G for doors windows clearstorey windows I/c bright finished black enamelled iron hinges with necessary secrews 30mm thick and 2nd class deodar wood.
15 mm thick cement plaster on fair sides of brick/stone masonery convrete walls for interior plastering upto floor two level including arises internal rounded angles not exceeding 80mm girth in cm 1:6 (1cement:6sand)
20 mm thick cement plaster on rough sides of brick/stone masonery convrete walls for interior plastering upto floor two level including arises internal rounded angles not exceeding 80mm girth in cm 1:6 (1cement:6sand)
6 mm thick cement plaster in CM 1:3( 1cement 3 sand in roof slabs
Distempering (two coats) with oil bond distemper of approved brand and manufacture and of required shade on undecorated surfaceto give an even shade and including priming coat with distemper after throughly brushing the surface free from mortar dropping and other foreign matters.
Finishing wall with water profing cement paint of approved brand and manufacture and of rerquired shade on undecorated wall surfaces (two coats) to give an even shade after thoroughly brushing the surface to remove all dirt and remains of loose powdered materials.
Applying priming coat over new wood and wood based surface after and including preparing the surface by throughly cleaning oil grease & dirt and other foreign matters.
a)Painting two coats(excluding priming coat) on new wood and wood based surfaces with ready mixed paint brushing to give even shade including cleaning all dirt, dust and other foreign matters white paint
b)Painting two coats(excluding priming coat) on new wood and wood based surfaces with ready mixed paint brushing to give even shade including cleaning all dirt, dust and other foreign matters other than white paint
Providing and fixing of MS grill of required patttern in wooden frame of window etc. with MS rounded headed bolts and nuts or by screw: Plain Grill within all leads and lifts and as directed by the Engineer-in-charge.
Stone soling properly hand packed filling interstices with spalls and consolidating with power road roller to the required gradient and camber including spreading watering and rolling of binding materials moorum or earth etc. 100mm spread thickness (finished work including materials and laboour) within all leads and lifts and as directed by the Engineer-in-charge.
Providing and fixing anodized Mild Steel sliding door bolts withnuts and screws complete I) 250mmX16mm with in all leads and lifts as per the direction of the Engineer in charge.
Providing and fixing anodized aiuminium. tower bolts barrel type with screws etc. complete.
I) 200mmX10mm
ii) 100mmx10mm
Providing and fixing anodized mild steel .handles with screws etc. complete. with in all leads and lifts as per the direction of the Engineer in charge.
I)125mm dia
ii) 100mm dia
Providing 40x3 mm flat iron hold fast 40cm. Long including fixing to frame with 10mm dia metres bolts, nuts and wooden plug and embedding in cement concrete block 30x10x15cm. 1:3:6( 1cement:3sand:6 graded stone att. 20mm nominal size) within all leads and per the directions of the Engineer in charge.
Providing plinth protection 50mm thick in cement concrete 1:3:6(1cement:3sand:6graded stone agg. 20mm nominal size) i/c finishing the top surface of concrete smooth within all leads and lifts and as directed by the Engineer-in-charge.
Supplying of various materials for pump house.
(i)Tool Kit for Pump house (24 items) with all accessory etc.
(i) Insulation mate (6'x4'), Bearing puller, insulation gloves & gress gen 1 No each ofr pump house
(iii) Steel / C.I.chairs,Poly table & stool 1 no each for pump house.
(v) P/F of gantry girder 1 No each of pump house( 2.0T)
Providing & fixing of Finalax pipe 40 mm dia. Under floor ( for connection cables ) including all req. fitting i:e elbows,sockets etc.
Supplying and fixing woven plain GI fencing of mesh 50 to 150mm to any type of standard rails strainging bolts etc. i/c provision of binding wire etc.
Providing and laying heavy duty precast cement conrete inter locking precast cement conrete inter locking paver blocks vibro compacted upto M-50 grade i/c border or kurb block grey or coloured over sub-base of concrete with 25mm thick average thickness of cement mortar 1:4 (1 cement : 4 sand) laid over and jointed with neat cement slurry mixed with pigment to match the shade of blocks i/c curing rubbing & polishing complete (Sub base concrete floor to be paid for 60mm thick inter locking blocks
Providing and fixing 10mm thick antiskid water proof stain and impect resitent resistent heavy duty vetrified tiles Nitco or equivalent 600x600mmx10mm manufactured or approved shade and colour in flooring and landings laid over (12mm thick cement mortar 1:3)(1Cement:3Sand)jointed with cement slurry mixed with pigment to match the shade of tiles as required complete within all leads and lifts and as directed by the Engineer-in- charge..
Providing and fixing 0.45 mm thick prepainted steel sheet in roofing with hot dipped metallic zinc coated sheet with top coat of regular modified polyster (RNP) organic coating of 20 microns over 5 microns primer coating to back coat of polyster of 5microns over 5 microns primer coating i/c fixing with prepainted iron J or L hooks, bolts and nuts 6mm dia metre with prepainted limpet and rubber washers complete with all accesoriees as required as per the direction of Engineer-in-charge.
Providing and fixing ridges or hips 60 cm overall with 0.45 mm thick prepainted steel sheet in roofing with hot dipped metallic zinc coated sheet with top coat of regular modified polyster (RNP) organic coating of 20 microns over 5 microns primer coating to back coat of polyster of 5microns over 5 microns primer coating i/c fixing with prepainted iron J or L hooks, bolts and nuts 6mm dia metre with prepainted limpet and rubber washers complete with all accesoriees as required as per the direction of Engineer-in-charge.
Providing and fixing prepainted steel sheet ceiling with 0.30mm thick in panets of steel channels base frame in ceiling with screws complete (steel channels base frame to be measured and paid for separately
Providing and fixing anodised aluminium work for door, window, ventilators &partitions with extruded built up standard tubular and other sections of approved make conforming to IS 733 and IS 1285 anodised according to IS1868.(Minimum anodic coating of grade AC 15) fixed with rawlplugs and screws up of gaps at junctions, at top, felt etc. Aluminium sections shall be smooth,All complete as per architectural drawings and the direction of Eingineer-in-charge
P/F in position rolled steel shutters with vertical chanels 20 mm x 10 mm x 2 mm & braced with flat iran diagonals 20mm x 5mm size with top and bottom rail of t iron 40 mm x 40 mm x6 mm with 38 mm dia steel pulley complate with bolts and nuts lockin arrangments , stoppers ,handles including appling a priming coat of red lead paint.
Providing and fixing glazing in aluminium door and windows ,ventilater shutters and partition etc.with PVC/ neorens gasket etc. complete as per the architewctural drawing and the directions of Engineer-in-Charge(cost of aluminium snap beadingshall be paidin basic item) glazing with glass panes of 5.50 mm thickness (weight not less than 13.75 kg/sqm.ly
Providing and placing horizontal layers filtering media duly graded screened washed and cleaned as specified by the Engineer Incharge with in all leads and lifts.
(i) Prov. Dry Bricks for filter bed/septic tanks
(ii) Coarse sand 3mm to 6mm
Providing and fixing vitreous China wash down water closet (European type. W.C. Pan) with integral 'P' or 'S' trap including jointing the trap with soil pipe in cement mortar 1:1 (1Cement : 1 Sand) (Seat and cover to be measured and paid for separately) Ordinary type.
Providing and fixing Stainless steel kitchen sink with drain board with in all leads and lifts as per the directions of the Engineer in charge. 470X 420X 178MM
Prorviding and fixing vitreous china wash basin with single hole for piller tap with C.I. or M.S. brackets painted white Flat back 630mmx450mm within all leads and lifts and as directed by the Engineer-in-charge.including cutting holes and making good the same but excluding fittings:-with in all leads and lifts as per the directions of the Engineer in charge.
Providing and fixing PTMT Coloured / white high density polyethlylene / poly propylene 10 liters cap. full flush European standard control low level flushing Cistern with fitting and within all leads and lifts and as directed by the Engin
P/F C.P. brass waste for wash basin or sink (i)32mm diawith in all leads and lifts as per the directions of the Engineer in charge.
P/F C.P. soap dish with C.P. brass brackets fixed to wooden cleats With C.P. brass screws with in all leads and lifts as per the directions of the Engineer in charge.
P/F C.P. Brass Bib tap with capstan head(15mm dia) with in all leads and lifts as per the directions of the Engineer in charge.
P/F brass full wheel valve with capstan head(15mm dia)within all leads and lifts and as directed by the Engineer-in-charge,
P/F C.P. Angle cock 15mm dia within all leads and lifts as per the directions of the Engineer-in-charge,
P/F of GI Elbow 15mm with in all leads and lifts as per the directions of the Engineer in charge.
P/F of GI Tee 15mm with in all leads and lifts as per the directions of the Engineer in charge.
P/F of GI Nipple 15mm with in all leads and lifts as per the directions of the Engineer in charge.
Providing and laying galvanized mild steel tube (heavy class) in wall. Ceiling including with in all leads and lifts as per the directions of the Engineer in charge .15mm dia(fiifteen milimetres)nominal size.(H . C )
Providing and fixing 600mmx450mm bevelled edge miror of superior glass mounted on 6mm thick A.C. sheet or plywood sheet and fixed to wooden plugs with C.P. Brass screws and washers. within all leads and lifts and as directed by the Engineer-in-charge.
Providing and fixing in trenches 10 Kg.f/cum2 working pressure unplasticized P.V.C. pipe (Conforming to IS: 4985-1968) complete fittings (earth work in trenches to be measured and paid for separately):-
a)110 mm out side diameter.
b)Elbow 100 mm dia.
c)Clamps 100mm dia.
d)Door Bends
e)Plain bends
f)Collar
g) Cowl
h)Floor Traps
Wiring for light point/fan point/exhaust fan/call bell point with 1.5 Sq.mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in PVC casing & capping and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required. with in all leads and lifts as per direction of the Engineer-in-Charge. Group A.
Wiring for power plug with 2x4 Sq.mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke sinlge core (flexible) copper conductor cable in PVC casing & capping along with 1 No. 4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.with in all leads and lifts as per direction of the Engineer-in-Charge. Group A.
Wiring for power plug with 4x4 Sq.mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke sinlge core (flexible) copper conductor cable in PVC casing & capping along with 2 No. 4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.with in all leads and lifts as per direction of the Engineer-in-Charge. Group A.
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke sinlge core (flexible) copper conductor cable in PVC casing & capping along with 1 No. HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required. with in all leads and lifts as per direction of the Engineer-in-Charge.
2x1.5 Sq.mm.
2x10 Sq.mm.
Supplying & Fixing wooden boxes of following sizes (nominal size) on surface or in recess suitable for fixing phenolic laminated sheet cover in front including painting etc. as required. with in all leads and lifts as per direction of the Engineer-in-Charge.
102mm.x102mm.x60mm. Deep.
178mm.x102mm.x60mm. Deep.
203mm.x152mm.x60mm. Deep.
203mm.x254mm.x60mm. Deep.
Supplying and fixing following rating Piano-type switch/socket on the existing switch box/cover including connections etc. as required. with in all leads and lifts as per direction of the Engineer-in-Charge.
S.P. 5/6 Amps one way switch, piano type.
S.P. 15/16 Amps one way switch, porcelain base/paino type.
5 pn 5/6 Amps socket outlet, poreclain base/piano type.
6 pin 15/16 Amps socket outlet, porcelain base/piano type.
Supplying and fixing bakelite batten/angle holder including connections etc. as required. with in all leads and lifts as per direction of the Engineer-in-Charge.
Supplying and erection of 6 amps, to 32 amps, rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required. with in all leads and lifts as per direction of the Engineer-in-Charge. Single pole . Cat-A
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. with in all leads and lifts as per direction of the Engineer-in-Charge. 40 Amps. Cat- A
Supplying and fixing of following way, single pole and netural sheet steel MCB distribution board, 240 volts, on surface/recess, complete with tinned copper bus-bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels inter-connections phosphatized and powder painted, including earthing etc. as required. with in all leads and lifts as per direction of the Engineer-in-Charge. Single door-6 way
Earthing with G.I. earth pipe 4.5mtr. Long and 40mm dia, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. with in all leads and lifts as per direction of the Engineer-in-Charge.
Extra for using salt and charcoal for pipe earth eletrode complete as required. with in all leads and lifts as per direction of the Engineer-in-Charge.
Supplying and laying 6 SWG G.I. wire at 0.50 mtr. Below ground level for earth electrode conductor, including soldering etc. as required. with in all leads and lifts as per direction of the Engineer-in-Charge.
Providing and fixing sleek and decorative strip type fixture with domestic electronic ballast and colored engineering plastic end plates, suitable for 28 watt FTL (T5), complete with all accessoris (excluding the T-8 tube), connections, testing and commissioning etc. as required. 1x 28 watt-FTL (T5) (Category-A with in all leads and lifts as per direction of the Engineer-in-Charge.
Providing, Installation, testing and commissioning of ceiling fan with regulator, including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required. with in all leads and lifts as per direction of the Engineer-in-Charge.
Supplying and fixing Ding-Dong/Electronic musical bell, suitable for D.C./A.C. single phase, 230 volts complete as required. with in all leads and lifts as per direction of the Engineer-in-Charge.
Supplying and fixing of integral CFL Post Top Lantern of following capacity, cast aluminium spigot, spun alumnium canopy, opal acrylic diffuser, complete with all accessoreis but excluding CFL lamp including making connections, testing etc. as required. Gate post top lantern-FCL 26 watt. with in all leads and lifts as per direction of the Engineer-in-Charge.
Providing laying and fixing of one No. aluminuim conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade on surface etc. of the required size. Armoured cable 4 sq. m (twin core) with in all leads and lifts as per direction of the Engineer-in-Charge.
Erection of Galvanized Iron (G.I.)/Steel tubular or Steel rail pole of length 3 to 8 metre but not exceeding 8 metres up to a given depth below G/L. the hole of excavation about 30 cm dia. And given depth to filled in up to 15 cm below G/L with 1:3:6 cement concrete and three above plinth with 1:2:4 cement concrete up to a height of 45 cm from G/L. The radial thickness of the plinth above G/L should not be less than 6.35 cm and sufficient to completely flush a 180 mm x 10mm x 45mm deep, glass filled Nylan F.R. grade box for housing a 16 Amp. MCB, the outer surface of the plinth to be finished with 1:3 cement plaster 6mm thick, the fuse-box shall have a water tight cover, including excavation and refilling etc. compelt in all respects as required. with in all leads and lifts as per direction of the Engineer-in-Charge.
Pumping and Machinery: Booster Stage. Supply of horizontal spindle,horizontal split casing Single/Multistage centrifugal/reciprocating pumps of standard make such as KSB/ Mathar & Platt/ Jayoti/ Kirloskar/WASP confirming to BIS 1520-1980 (latest with upto date ammendments) read with BIS 9137-1978 or latest to handle raw water having turbidity 50 ppm. with impelleres,casing ring & shaft sleeves of bronze, shaft of steel with cast iron casing of suitable capacity coupled directly through a flexible coupling on a common base plate to Kirlokar/NGEF/Crompton/ Siemen/Jyoti slip ring/squirrel cage screen protected drip proof electric induction motor suitable for operation on the data given belowa) Pump: Specification 1 ) Make 2) Model 3) No of Stages 4) Material (Manufactured certificate to be appended performances) i) Head(H) mtr. ii) Discharge LPS iii) BHP Absorbed iv) Effeciency (n) v) NPSH b) Motor i) Make ii) Model iii) Motor rating iv) Speed v) Insulation.
i) Discharge (Q) 20.46 LPS each pump. ( 2 no. pumps one to work at a time independently)
ii) Total Dynamic head 32.50 mtrs.
a) LWL of sump well (h) 1410 mtr.
b) Shaft level 1410mtr.
c) Level at discharge point 1440 mtr.
d) suction lift (+) head 32.50 mtr.
e) Discharge head 32.50 mtr.
f) Static head 30 mtr.
iii) Rising main
a) Length 50 mtr.
b) Dia 200 mm.
iv) Pumping hour 16 hours.
v) Altitude of installation above MSL mtr.
vi) Characterstics of water. Clear cold water
a) Temperature 0C.
b) Ambient temp. 0C.
c) Turbiduty JTU
d) Alkanality
e) Size of the solid NIL mm.
f) Other
ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen make and having capacity 30% extra of the operational rating of motor as BIS 4064-1978 with upto date ammendments immediately after the power meter of HPSEB. ICTC Switch Make Type Capacity
Providing M.S Sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting the following accessaries with all internal electric connections. The drawing of panel board shall be subject to approval of Engineer-in-charge .Panel/Switch Board i) Drawing ii) Layout Plan
MCB/Oil circuit breaker of suitable capacity of Kilburn/LT/LK/MEI/Standard make on in coming feeder for motors offered by the tenderer conformaing to BIS 2516-1985 latest with upto date ammendments with neutral linked under voltage release. ACB/OCB i) Make ii) Type iii) Range iv) Capacity
Earth leakage circuit braker of requcemended (Kilburn/L&T/MET/GEC as per BIS-2516-1977 with upto date ammendments and of suitable range with which should have control box , oprating handel and trip/rest bush button / off indicators,re-indicating off spring condition of the circuit braker for over current protection.The curcuit should be equipped with magnet thermal release with metallic tap CTS.It should also be fitted earth fault for trippping of breaker on occurance of earth fault on/of braker load side.ELCB i) Make ii) Type iii) Range Voltage relay meter i) Make ii) Type iii) Range
Supply & errection of floor/wall mounted power factor capacitor conforming to BIS 2834-1986 latest with upto date ammendment Power factor meter Type Make
Frequecy meter of standard make as per relevent IS code with upto date ammendments Frequency Meter i)Make ii) Type iii) Range
Bus bar chamber having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating for full length for naturalnphase as per IS 8084-1976 and IS 11353-1985 read with BIS-5578-with upto date ammendments. Bus bar chanber i) Make ii) Type iii) Rating.
ICTC switches with HRC fuses of Kilburn/L&T/Siemens/Standard/ Havels make and of suitable capacity as per IS 4064-1978 with upto date ammendments. ICTC Switches i) Type ii) Make iii) Capacity
Three phase indicator lamp complete with toggie switches for indivisual motor as per IS:3452 (P-l&lll) with up to date ammendments. Three phase indicator i)Type ii) Make iii) Capacity.
Supply & errection of floor/wall mounted power factor capacitor conforming to BIS 2834-1986 latest with upto date ammendment BHEL/GEC/Machneil/Masger/Bajaj make to raise the pervailing power factor at site to 0.95 for direct connection to induction motor individually, or requird KVAR according to Himachal Pradesh of motor offered including cable siemens/ Gloster/ICC make from busbar chamber to capacitor & also including LT/LK/Kilburn make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer. Capacitor i) Type ii) Make iii) Range.
Hour rum meter of reputed make.
Supply of suitable oil immersed star delta starter/ATS/stator rotor starter of standared make such as MEI/Kilburn/Jyoti/Siemens conforming to BIS-8544-1979 leates with up to date ammendments for squirrel cage/slipering motor(make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot, time log , under voltage release wfith initial oil filling. Single phase preventer i) Type ii) Make
Providing and fixing cast iron flanged/screw type stainer as per IS 4038-1986 with upto date ammendments of Kiloskar/GIED/ Kilburn/ Karter valve Mechneil/ Kilburn leader make 65mm dia. Foot Valve i) Make
Providing and fixing cast iron double flanged sluice valve of class II 65mm dia of leader/ Behl Kirlsker/GIED/ Kilburn/Fouress make n suction side as per the relevent IS code.
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/of reputed make of suitable size cast iron /cast steel double flanged sluice valve having size equal to delivery of pump and capable of with standing nominal seat pressure of 52kg/cm^2. The sluice valve shall conform to BIS 780-1984 latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21Kg/cm^2) or class 300 ASA (seat pressure 52Kg/cm^2) as per BS 1414 Sluice Valve i) Make ii) Class iii) Sheet Pressure iv) Material
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/of suitable size cast iron /cast steel double flanged swing check type reflux valve having bye pass arrangement & size equal to delivery of pump for withstanding nominal seat pressure of 52Kg/cm/^2 The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be cast steel conforming to class 150 ASA (Seat pressure 231Kg/cm^2) or class 300 ASA (seat pressure 52Kg/cm^2)) as per BSI 1414 Reflux Valve i) Make ii) Class iii) Sheet Pressure iv) Material
Providing and fixing double flanged cast steel reflux valve of Leader/BHEL/Kilosker/Kilburn/ GLED/Fouress make and of 50mm dia for rising main having byepass arrangement for rising main andcapable withstanding the normal steel pressure as per IS 780-1984 with up to date ammendments class ASA to be mentioned by the firm. Reflux Valve i) Make ii) Class iii) Sheet Pressure iv) Material
Supply of standard make 100mm dia circular dial pressure of suitable range Fiebeg/ Bourden/Precision make with all accessories such as stop cock, copper tubing etc. conforming to BIS 3624-1987 latest with up to date ammendments. Pressure Guage i) Make ii) Range
Providing, laying, testing & commissioning at site in trenches bevelled ended conforming to IS/ISO:3183-2007 latest having wall thickness & per Rmt. weight as mentioned below & capable of withstanding required test pressure as prescribed in BIS code, in random lengths of 5.5 to 6.5 mtr. The pipe ends shall be bevelled suitable for butt welding, including the cost of jointing with butt welding confirming to IS 816-1969 or latest as applicable and with uptodate ammendements (leak proof) in three layers at site of work welding rods of Advani/oerliken make/ISI marked (welding rods 3mm to 4mm) and all allied accessories whatever required for welding at site, tail please, tees, bends & other special manufactured from parent pipes as applicable to the particular reach and of approved specification as per site conditions and cutting of pipe wherever required as per site requirement including carriage in all leads & lifts and as directed by the Engineer-in-charge. The pipe shall have zinc coating inside & out side confirming to IS-4736-1986 or latest with upto date ammendments & shall be engraved with API- X 46 etc. The sizes of various components to be as under: l) Suction Pipe ---------- mm dia ii) Delivery Pipe ---------- mm dia iii) Common Header ---------- mm dia. and will be extended up to 5 mtr from the outer wall of the pump house in th direction to be jointed. Suction Pipe i) Material ii) Grade iii) Thickness iv) Pressure Rating - Delivery pipe and common header i) Material ii) Grade iii) Thickness iv) Pressure Rating
Providing and laying copper PVC insulated armoured power cable (One vable carrying all the three phasees) of suitable size and capacity to motors and all other electrical equipments as per IS:1554 (P-1) 1988 or latest with up to date ammendments of seimence/Gloster/IEC/EICO/National/Grandly make including all other accessories such as thimbles, flexible pipe, solder, nut & bolts, vable gland etc. laid in pipe or trenches under floor.
P/L double loop earthing with crpper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt, GI pipes, thimbles, nuts & bolts, digging of pits, GI wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendmentsfor above motors & other electrical equipment. Armored power cable of HPSEB to bus bar 10mtr. i) Size ii) Make iii) Type Copper iv)Capacity v) Core 3
Pumping and Machinery: 1st Stage. Supply of horizontal spindle,horizontal split casing Single/Multistage centrifugal/reciprocating pumps of standard make such as KSB/ Mathar & Platt/ Jayoti/ Kirloskar/WASP confirming to BIS 1520-1980 (latest with upto date ammendments) read with BIS 9137-1978 or latest to handle raw water having turbidity 50 ppm. with impelleres,casing ring & shaft sleeves of bronze, shaft of steel with cast iron casing of suitable capacity coupled directly through a flexible coupling on a common base plate to Kirlokar/NGEF/Crompton/ Siemen/Jyoti slip ring/squirrel cage screen protected drip proof electric induction motor suitable for operation on the data given below (a) Pump: Specification 1) Make 2) Model 3) No of Stages 4) Material (Manufactured certificate to be appended performances) i) Head(H) mtr. ii) Discharge LPS iii) BHP Absorbed iv) Effeciency (n) v) NPSH b) Motor i) Make ii) Model iii) Motor rating iv) Speed v) Insulation.
i) Discharge (Q) 20.46 LPS each pump.
ii) Total Dynamic head 424.56 mtrs.
a) LWL of sump well (h) 1420 mtr.
b) Shaft level 1420 mtr.
c) Level at discharge point 1830 mtr.
d) suction lift (+) head 424.56 mtr.
e) Discharge head 424.56 mtr.
f) Static head 410 mtr.
iii) Rising main
a) Length 3200 mtr.
b) Dia 200 mm.
iv) Pumping hour 16 hours.
v) Altitude of installation above MSL mtr.
vi) Characterstics of water. Clear cold water
a) Temperature 0C.
b) Ambient temp. 0C.
c) Turbiduty JTU
d) Alkanality
e) Size of the solid NIL mm.
f) Other
ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen make and having capacity 30% extra of the operational rating of motor as BIS 4064-1978 with upto date ammendments immediately after the power meter of HPSEB. ICTC Switch Make Type Capacity
Providing M.S Sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting the following accessaries with all internal electric connections. The drawing of panel board shall be subject to approval of Engineer-in-charge. Panel/Switch Board i) Drawing ii) Layout Plan
MCB/Oil circuit breaker of suitable capacity of Kilburn/LT/LK/MEI/Standard make on in coming feeder for motors offered by the tenderer conformaing to BIS 2516-1985 latest with upto date ammendments with neutral linked under voltage release. ACB/OCB i) Make ii) Type iii) Range iv) Capacity
Earth leakage circuit braker of requcemended (Kilburn/L&T/MET/GEC as per BIS-2516-1977 with upto date ammendments and of suitable range with which should have control box , oprating handel and trip/rest bush button / off indicators,re-indicating off spring condition of the circuit braker for over current protection.The curcuit should be equipped with magnet thermal release with metallic tap CTS.It should also be fitted earth fault for trippping of breaker on occurance of earth fault on/of braker load side. ELCB i) Make ii) Type iii) Range Voltage relay meter i) Make ii) Type iii) Range
Supply & errection of floor/wall mounted power factor capacitor conforming to BIS 2834-1986 latest with upto date ammendment Power factor meter Type Make
Frequecy meter of standard make as per relevent IS code with upto date ammendments Frequency Meter i)Make ii) Type iii) Range
Bus bar chamber having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating for full length for naturalnphase as per IS 8084-1976 and IS 11353-1985 read with BIS-5578-with upto date ammendments. Bus bar chanber i) Make ii) Type iii) Rating.
ICTC switches with HRC fuses of Kilburn/L&T/Siemens/Standard/ Havels make and of suitable capacity as per IS 4064-1978 with upto date ammendments. ICTC Switches i) Type ii) Make iii) Capacity
Three phase indicator lamp complete with toggie switches for indivisual motor as per IS:3452 (P-l&lll) with up to date ammendments. Three phase indicator i)Type ii) Make iii) Capacity.
Supply & errection of floor/wall mounted power factor capacitor conforming to BIS 2834-1986 latest with upto date ammendment BHEL/GEC/Machneil/Masger/Bajaj make to raise the pervailing power factor at site to 0.95 for direct connection to induction motor individually, or requird KVAR according to Himachal Pradesh of motor offered including cable siemens/ Gloster/ICC make from busbar chamber to capacitor & also including LT/LK/Kilburn make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer. Capacitor i) Type ii) Make iii) Range.
Hour rum meter of reputed make.
Supply of suitable oil immersed star delta starter/ATS/stator rotor starter of standared make such as MEI/Kilburn/Jyoti/Siemens conforming to BIS-8544-1979 leates with up to date ammendments for squirrel cage/slipering motor(make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot, time log , under voltage release wfith initial oil filling. Single phase preventer i) Type ii) Make
Providing and fixing cast iron flanged/screw type stainer as per IS 4038-1986 with upto date ammendments of Kiloskar/GIED/ Kilburn/ Karter valve Mechneil/ Kilburn leader make 65mm dia. Foot Valve i) Make
Providing and fixing cast iron double flanged sluice valve of class II 65mm dia of leader/ Behl Kirlsker/GIED/ Kilburn/Fouress make n suction side as per the relevent IS code.
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/of reputed make of suitable size cast iron /cast steel double flanged sluice valve having size equal to delivery of pump and capable of with standing nominal seat pressure of 52kg/cm^2. The sluice valve shall conform to BIS 780-1984 latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21Kg/cm^2) or class 300 ASA (seat pressure 52Kg/cm^2) as per BS 1414 Sluice Valve i) Make ii) Class iii) Sheet Pressure iv) Material
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/of suitable size cast iron /cast steel double flanged swing check type reflux valve having bye pass arrangement & size equal to delivery of pump for withstanding nominal seat pressure of 52Kg/cm/^2 The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be cast steel conforming to class 150 ASA (Seat pressure 231Kg/cm^2) or class 300 ASA (seat pressure 52Kg/cm^2)) as per BSI 1414 Reflux Valve i) Make ii) Class iii) Sheet Pressure iv) Material
Providing and fixing double flanged cast steel reflux valve of Leader/BHEL/Kilosker/Kilburn/ GLED/Fouress make and of 50mm dia for rising main having byepass arrangement for rising main andcapable withstanding the normal steel pressure as per IS 780-1984 with up to date ammendments class ASA to be mentioned by the firm. Reflux Valve i) Make ii) Class iii) Sheet Pressure iv) Material
Supply of standard make 100mm dia circular dial pressure of suitable range Fiebeg/ Bourden/Precision make with all accessories such as stop cock, copper tubing etc. conforming to BIS 3624-1987 latest with up to date ammendments. Pressure Guage i) Make ii) Range
Providing, laying, testing & commissioning at site in trenches bevelled ended conforming to IS/ISO:3183-2007 latest having wall thickness & per Rmt. weight as mentioned below & capable of withstanding required test pressure as prescribed in BIS code, in random lengths of 5.5 to 6.5 mtr. The pipe ends shall be bevelled suitable for butt welding, including the cost of jointing with butt welding confirming to IS 816-1969 or latest as applicable and with uptodate ammendements (leak proof) in three layers at site of work welding rods of Advani/oerliken make/ISI marked (welding rods 3mm to 4mm) and all allied accessories whatever required for welding at site, tail please, tees, bends & other special manufactured from parent pipes as applicable to the particular reach and of approved specification as per site conditions and cutting of pipe wherever required as per site requirement including carriage in all leads & lifts and as directed by the Engineer-in-charge. The pipe shall have zinc coating inside & out side confirming to IS-4736-1986 or latest with upto date ammendments & shall be engraved with API- X 46 etc. The sizes of various components to be as under: l) Suction Pipe ---------- mm dia ii) Delivery Pipe ---------- mm dia iii) Common Header ---------- mm dia. and will be extended up to 5 mtr from the outer wall of the pump house in th direction to be jointed. Suction Pipe i) Material ii) Grade iii) Thickness iv) Pressure Rating - Delivery pipe and common header i) Material ii) Grade iii) Thickness iv) Pressure Rating
Providing and laying copper PVC insulated armoured power cable (One vable carrying all the three phasees) of suitable size and capacity to motors and all other electrical equipments as per IS:1554 (P-1) 1988 or latest with up to date ammendments of seimence/Gloster/IEC/EICO/National/Grandly make including all other accessories such as thimbles, flexible pipe, solder, nut & bolts, vable gland etc. laid in pipe or trenches under floor. Armored power cable a) Motor side (From switch to starter 20 mtr. And starter to Motor.10mtr. i) Size ii) Make iii) Type Copper iv)Capacity v) Core 3
P/L double loop earthing with crpper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt, GI pipes, thimbles, nuts & bolts, digging of pits, GI wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendmentsfor above motors & other electrical equipment. Armored power cable of HPSEB to bus bar 10mtr. i) Size ii) Make iii) Type Copper iv)Capacity v) Core 3
Pumping and Machinery: 2nd Stage.Supply of horizontal spindle,horizontal split casing Single/Multistage centrifugal/reciprocating pumps of standard make such as KSB/ Mathar & Platt/ Jayoti/ Kirloskar/WASP confirming to BIS 1520-1980 (latest with upto date ammendments) read with BIS 9137-1978 or latest to handle raw water having turbidity 50 ppm. with impelleres,casing ring & shaft sleeves of bronze, shaft of steel with cast iron casing of suitable capacity coupled directly through a flexible coupling on a common base plate to Kirlokar/NGEF/Crompton/ Siemen/Jyoti slip ring/squirrel cage screen protected drip proof electric induction motor suitable for operation on the data given below (a) Pump: Specification 1) Make 2) Model 3) No of Stages 4) Material (Manufactured certificate to be appended performances) i) Head(H) mtr. ii) Discharge LPS iii) BHP Absorbed iv) Effeciency (n) v) NPSH b) Motor i) Make ii) Model iii) Motor rating iv) Speed v) Insulation.
i) Discharge (Q) 14.02 LPS each pump.
ii) Total Dynamic head 688.73 mtrs.
a) LWL of sump well (h) 1630 mtr.
b) Shaft level 1630 mtr.
c) Level at discharge point 2280 mtr.
d) suction lift (+) head 688.73 mtr.
e) Discharge head 688.73 mtr.
f) Static head 650 mtr.
iii) Rising main
a) Length 5000 mtr.
b) Dia 150mm.
iv) Pumping hour 16 hours.
v) Altitude of installation above MSL mtr.
vi) Characterstics of water. Clear cold water
a) Temperature 0C.
b) Ambient temp. 0C.
c) Turbiduty JTU
d) Alkanality
e) Size of the solid NIL mm.
f) Other
ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen make and having capacity 30% extra of the operational rating of motor as BIS 4064-1978 with upto date ammendments immediately after the power meter of HPSEB. ICTC Switch Make Type Capacity
Providing M.S Sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting the following accessaries with all internal electric connections. The drawing of panel board shall be subject to approval of Engineer-in-charge. Panel/Switch Board i) Drawing ii) Layout Plan
MCB/Oil circuit breaker of suitable capacity of Kilburn/LT/LK/MEI/Standard make on in coming feeder for motors offered by the tenderer conformaing to BIS 2516-1985 latest with upto date ammendments with neutral linked under voltage release. ACB/OCB i) Make ii) Type iii) Range iv) Capacity
Earth leakage circuit braker of requcemended (Kilburn/L&T/MET/GEC as per BIS-2516-1977 with upto date ammendments and of suitable range with which should have control box , oprating handel and trip/rest bush button / off indicators,re-indicating off spring condition of the circuit braker for over current protection.The curcuit should be equipped with magnet thermal release with metallic tap CTS.It should also be fitted earth fault for trippping of breaker on occurance of earth fault on/of braker load side. ELCB i) Make ii) Type iii) Range Voltage relay meter i) Make ii) Type iii) Range
Supply & errection of floor/wall mounted power factor capacitor conforming to BIS 2834-1986 latest with upto date ammendment Power factor meter Type Make
Frequecy meter of standard make as per relevent IS code with upto date ammendments Frequency Meter i)Make ii) Type iii) Range
Bus bar chamber having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating for full length for naturalnphase as per IS 8084-1976 and IS 11353-1985 read with BIS-5578-with upto date ammendments. Bus bar chanber i) Make ii) Type iii) Rating.
ICTC switches with HRC fuses of Kilburn/L&T/Siemens/Standard/ Havels make and of suitable capacity as per IS 4064-1978 with upto date ammendments. ICTC Switches i) Type ii) Make iii) Capacity
Three phase indicator lamp complete with toggie switches for indivisual motor as per IS:3452 (P-l&lll) with up to date ammendments. Three phase indicator i)Type ii) Make iii) Capacity.
Supply & errection of floor/wall mounted power factor capacitor conforming to BIS 2834-1986 latest with upto date ammendment BHEL/GEC/Machneil/Masger/Bajaj make to raise the pervailing power factor at site to 0.95 for direct connection to induction motor individually, or requird KVAR according to Himachal Pradesh of motor offered including cable siemens/ Gloster/ICC make from busbar chamber to capacitor & also including LT/LK/Kilburn make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer. Capacitor i) Type ii) Make iii) Range.
Hour rum meter of reputed make.
Supply of suitable oil immersed star delta starter/ATS/stator rotor starter of standared make such as MEI/Kilburn/Jyoti/Siemens conforming to BIS-8544-1979 leates with up to date ammendments for squirrel cage/slipering motor(make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot, time log , under voltage release wfith initial oil filling. Single phase preventer i) Type ii) Make
Providing and fixing cast iron flanged/screw type stainer as per IS 4038-1986 with upto date ammendments of Kiloskar/GIED/ Kilburn/ Karter valve Mechneil/ Kilburn leader make 65mm dia. Foot Valve i) Make
Providing and fixing cast iron double flanged sluice valve of class II 65mm dia of leader/ Behl Kirlsker/GIED/ Kilburn/Fouress make n suction side as per the relevent IS code.
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/of reputed make of suitable size cast iron /cast steel double flanged sluice valve having size equal to delivery of pump and capable of with standing nominal seat pressure of 52kg/cm^2. The sluice valve shall conform to BIS 780-1984 latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21Kg/cm^2) or class 300 ASA (seat pressure 52Kg/cm^2) as per BS 1414 Sluice Valve i) Make ii) Class iii) Sheet Pressure iv) Material
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/of suitable size cast iron /cast steel double flanged swing check type reflux valve having bye pass arrangement & size equal to delivery of pump for withstanding nominal seat pressure of 52Kg/cm/^2 The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be cast steel conforming to class 150 ASA (Seat pressure 231Kg/cm^2) or class 300 ASA (seat pressure 52Kg/cm^2)) as per BSI 1414 Reflux Valve i) Make ii) Class iii) Sheet Pressure iv) Material
Providing and fixing double flanged cast steel reflux valve of Leader/BHEL/Kilosker/Kilburn/ GLED/Fouress make and of dia for rising main having byepass arrangement for rising main andcapable withstanding the normal steel pressure as per IS 780-1984 with up to date ammendments class ASA to be mentioned by the firm. Reflux Valve i) Make ii) Class iii) Sheet Pressure iv) Material
Supply of standard make 100mm dia circular dial pressure of suitable range Fiebeg/ Bourden/Precision make with all accessories such as stop cock, copper tubing etc. conforming to BIS 3624-1987 latest with up to date ammendments. Pressure Guage i) Make ii) Range
Providing, laying, testing & commissioning at site in trenches bevelled ended conforming to IS/ISO:3183-2007 latest having wall thickness & per Rmt. weight as mentioned below & capable of withstanding required test pressure as prescribed in BIS code, in random lengths of 5.5 to 6.5 mtr. The pipe ends shall be bevelled suitable for butt welding, including the cost of jointing with butt welding confirming to IS 816-1969 or latest as applicable and with uptodate ammendements (leak proof) in three layers at site of work welding rods of Advani/oerliken make/ISI marked (welding rods 3mm to 4mm) and all allied accessories whatever required for welding at site, tail please, tees, bends & other special manufactured from parent pipes as applicable to the particular reach and of approved specification as per site conditions and cutting of pipe wherever required as per site requirement including carriage in all leads & lifts and as directed by the Engineer-in-charge. The pipe shall have zinc coating inside & out side confirming to IS-4736-1986 or latest with upto date ammendments & shall be engraved with API- X 46 etc. The sizes of various components to be as under: l) Suction Pipe ---------- mm dia ii) Delivery Pipe ---------- mm dia iii) Common Header ---------- mm dia. and will be extended up to 5 mtr from the outer wall of the pump house in th direction to be jointed. Suction Pipe i) Material ii) Grade iii) Thickness iv) Pressure Rating - Delivery pipe and common header i) Material ii) Grade iii) Thickness iv) Pressure Rating
Providing and laying copper PVC insulated armoured power cable (One vable carrying all the three phasees) of suitable size and capacity to motors and all other electrical equipments as per IS:1554 (P-1) 1988 or latest with up to date ammendments of seimence/Gloster/IEC/EICO/National/Grandly make including all other accessories such as thimbles, flexible pipe, solder, nut & bolts, vable gland etc. laid in pipe or trenches under floor. Armored power cable a) Motor side (From switch to starter 20 mtr. And starter to Motor.10mtr. i) Size ii) Make iii) Type Copper iv)Capacity v) Core 3
P/L double loop earthing with crpper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt, GI pipes, thimbles, nuts & bolts, digging of pits, GI wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendmentsfor above motors & other electrical equipment. Armored power cable of HPSEB to bus bar 10mtr. i) Size ii) Make iii) Type Copper iv)Capacity v) Core 3
Pumping and Machinery: 3rd Stage. Supply of horizontal spindle,horizontal split casing Single/Multistage centrifugal/reciprocating pumps of standard make such as KSB/ Mathar & Platt/ Jayoti/ Kirloskar/WASP confirming to BIS 1520-1980 (latest with upto date ammendments) read with BIS 9137-1978 or latest to handle raw water having turbidity 50 ppm. with impelleres,casing ring & shaft sleeves of bronze, shaft of steel with cast iron casing of suitable capacity coupled directly through a flexible coupling on a common base plate to Kirlokar/NGEF/Crompton/ Siemen/Jyoti slip ring/squirrel cage screen protected drip proof electric induction motor suitable for operation on the data given below (a) Pump: Specification 1) Make 2) Model 3) No of Stages 4) Material (Manufactured certificate to be appended performances) i) Head(H) mtr. ii) Discharge LPS iii) BHP Absorbed iv) Effeciency (n) v) NPSH b) Motor i) Make ii) Model iii) Motor rating iv) Speed v) Insulation.
i) Discharge (Q) 10.94LPS each pump.
ii) Total Dynamic head 700.36 mtrs.
a) LWL of sump well (h) 2277 mtr.
b) Shaft level 2277 mtr.
c) Level at discharge point 2950 mtr.
d) suction lift (+) head 700.36 mtr.
e) Discharge head 700.36 mtr.
f) Static head 673 mtr.
iii) Rising main
a) Length 5500 mtr.
b) Dia 150 mm.
iv) Pumping hour 16 hours.
v) Altitude of installation above MSL mtr.
vi) Characterstics of water. Clear cold water
a) Temperature 0C.
b) Ambient temp. 0C.
c) Turbiduty JTU
d) Alkanality
e) Size of the solid NIL mm.
f) Other
ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen make and having capacity 30% extra of the operational rating of motor as BIS 4064-1978 with upto date ammendments immediately after the power meter of HPSEB. ICTC Switch Make Type Capacity
Providing M.S Sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting the following accessaries with all internal electric connections. The drawing of panel board shall be subject to approval of Engineer-in-charge. Panel/Switch Board i) Drawing ii) Layout Plan
MCB/Oil circuit breaker of suitable capacity of Kilburn/LT/LK/MEI/Standard make on in coming feeder for motors offered by the tenderer conformaing to BIS 2516-1985 latest with upto date ammendments with neutral linked under voltage release. ACB/OCB i) Make ii) Type iii) Range iv) Capacity
Earth leakage circuit braker of requcemended (Kilburn/L&T/MET/GEC as per BIS-2516-1977 with upto date ammendments and of suitable range with which should have control box , oprating handel and trip/rest bush button / off indicators,re-indicating off spring condition of the circuit braker for over current protection.The curcuit should be equipped with magnet thermal release with metallic tap CTS.It should also be fitted earth fault for trippping of breaker on occurance of earth fault on/of braker load side. ELCB i) Make ii) Type iii) Range Voltage relay meter i) Make ii) Type iii) Range
Supply & errection of floor/wall mounted power factor capacitor conforming to BIS 2834-1986 latest with upto date ammendment Power factor meter Type Make
Frequecy meter of standard make as per relevent IS code with upto date ammendments Frequency Meter i)Make ii) Type iii) Range
Bus bar chamber having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating for full length for naturalnphase as per IS 8084-1976 and IS 11353-1985 read with BIS-5578-with upto date ammendments. Bus bar chanber i) Make ii) Type iii) Rating.
ICTC switches with HRC fuses of Kilburn/L&T/Siemens/Standard/ Havels make and of suitable capacity as per IS 4064-1978 with upto date ammendments. ICTC Switches i) Type ii) Make iii) Capacity
Three phase indicator lamp complete with toggie switches for indivisual motor as per IS:3452 (P-l&lll) with up to date ammendments. Three phase indicator i)Type ii) Make iii) Capacity.
Supply & errection of floor/wall mounted power factor capacitor conforming to BIS 2834-1986 latest with upto date ammendment BHEL/GEC/Machneil/Masger/Bajaj make to raise the pervailing power factor at site to 0.95 for direct connection to induction motor individually, or requird KVAR according to Himachal Pradesh of motor offered including cable siemens/ Gloster/ICC make from busbar chamber to capacitor & also including LT/LK/Kilburn make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer. Capacitor i) Type ii) Make iii) Range.
Hour rum meter of reputed make.
Supply of suitable oil immersed star delta starter/ATS/stator rotor starter of standared make such as MEI/Kilburn/Jyoti/Siemens conforming to BIS-8544-1979 leates with up to date ammendments for squirrel cage/slipering motor(make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot, time log , under voltage release wfith initial oil filling. Single phase preventer i) Type ii) Make
Providing and fixing cast iron flanged/screw type stainer as per IS 4038-1986 with upto date ammendments of Kiloskar/GIED/ Kilburn/ Karter valve Mechneil/ Kilburn leader make 65mm dia. Foot Valve i) Make
Providing and fixing cast iron double flanged sluice valve of class II 65mm dia of leader/ Behl Kirlsker/GIED/ Kilburn/Fouress make n suction side as per the relevent IS code.
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/of reputed make of suitable size cast iron /cast steel double flanged sluice valve having size equal to delivery of pump and capable of with standing nominal seat pressure of 52kg/cm^2. The sluice valve shall conform to BIS 780-1984 latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21Kg/cm^2) or class 300 ASA (seat pressure 52Kg/cm^2) as per BS 1414 Sluice Valve i) Make ii) Class iii) Sheet Pressure iv) Material
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/of suitable size cast iron /cast steel double flanged swing check type reflux valve having bye pass arrangement & size equal to delivery of pump for withstanding nominal seat pressure of 52Kg/cm/^2 The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be cast steel conforming to class 150 ASA (Seat pressure 231Kg/cm^2) or class 300 ASA (seat pressure 52Kg/cm^2)) as per BSI 1414 Reflux Valve i) Make ii) Class iii) Sheet Pressure iv) Material
Providing and fixing double flanged cast steel reflux valve of Leader/BHEL/Kilosker/Kilburn/ GLED/Fouress make and of dia for rising main having byepass arrangement for rising main andcapable withstanding the normal steel pressure as per IS 780-1984 with up to date ammendments class ASA to be mentioned by the firm. Reflux Valve i) Make ii) Class iii) Sheet Pressure iv) Material
Supply of standard make 100mm dia circular dial pressure of suitable range Fiebeg/ Bourden/Precision make with all accessories such as stop cock, copper tubing etc. conforming to BIS 3624-1987 latest with up to date ammendments. Pressure Guage i) Make ii) Range
Providing, laying, testing & commissioning at site in trenches bevelled ended conforming to IS/ISO:3183-2007 latest having wall thickness & per Rmt. weight as mentioned below & capable of withstanding required test pressure as prescribed in BIS code, in random lengths of 5.5 to 6.5 mtr. The pipe ends shall be bevelled suitable for butt welding, including the cost of jointing with butt welding confirming to IS 816-1969 or latest as applicable and with uptodate ammendements (leak proof) in three layers at site of work welding rods of Advani/oerliken make/ISI marked (welding rods 3mm to 4mm) and all allied accessories whatever required for welding at site, tail please, tees, bends & other special manufactured from parent pipes as applicable to the particular reach and of approved specification as per site conditions and cutting of pipe wherever required as per site requirement including carriage in all leads & lifts and as directed by the Engineer-in-charge. The pipe shall have zinc coating inside & out side confirming to IS-4736-1986 or latest with upto date ammendments & shall be engraved with API- X 46 etc. The sizes of various components to be as under: l) Suction Pipe ---------- mm dia ii) Delivery Pipe ---------- mm dia iii) Common Header ---------- mm dia. and will be extended up to 5 mtr from the outer wall of the pump house in th direction to be jointed. Suction Pipe i) Material ii) Grade iii) Thickness iv) Pressure Rating - Delivery pipe and common header i) Material ii) Grade iii) Thickness iv) Pressure Rating
Providing and laying copper PVC insulated armoured power cable (One vable carrying all the three phasees) of suitable size and capacity to motors and all other electrical equipments as per IS:1554 (P-1) 1988 or latest with up to date ammendments of seimence/Gloster/IEC/EICO/National/Grandly make including all other accessories such as thimbles, flexible pipe, solder, nut & bolts, vable gland etc. laid in pipe or trenches under floor. Armored power cable a) Motor side (From switch to starter 20 mtr. And starter to Motor.10mtr. i) Size ii) Make iii) Type Copper iv)Capacity v) Core 3
P/L double loop earthing with crpper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt, GI pipes, thimbles, nuts & bolts, digging of pits, GI wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendmentsfor above motors & other electrical equipment.
P/L double loop earthing with crpper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt, GI pipes, thimbles, nuts & bolts, digging of pits, GI wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendmentsfor above motors & other electrical equipment. Armored power cable of HPSEB to bus bar 10mtr. i) Size ii) Make iii) Type Copper iv)Capacity v) Core 3
Providing, laying, & commissioning at site in trenches to be beveled ended pipe conforming to IS/ISO:3183-2007 (Latest with up to date amendments) having minimum wall thickness as specified below & capable of withstanding required test pressure as prescribed in IS/ISO code, in random lengths of 5.5 to 6.5 mtr. The pipe ends shall be levelled suitable for butt welding, including thecost of jointing with butt welding confirming to IS 816-1969 or latest applicable and with uptodate ammendments (leak proof) in three layers at siteof work with welded rods of Advani/oeriliken make/ISI marked (welded rods 3mm to 4mm) and all allied accessories whatever required for welding at site, tail pieces,tee bends & other special manufactured from parent pipes as applicable to the particular reach and of approved specification as per site conditions. and cutting of pipes wherever required as per site requirement including carriage in all leads & lifts andas directed by the Engineer-In-Charge. The pipe shall have zinc coating inside & outside confirming to IS-4736-1986 or latest with upto date ammendments & shall be marked with API-X56 , X65 ,X60 , X42 L-245 etc The laying shall cofirm to BIS 5822-970 or latest with upto date ammendments to the entire satisfaction of Engineer-In-Charge. (Earth work & cost of MS Flanges after 100meter length shall be measured & paid for seperately.) including all leads, lifts and carriage of materials at site andas per direction and to the entire satisfaction of the Engineer-In-Charge.
Zone 1st Booster Stage RD-0 to 50 API-X56 L-390 W.T 4.80mm 200mm dia. Stage 1st. RD-0 to 3200 API-X56 L-390 W.T 4.80mm 200mm dia.
Stage 2nd. RD-0 to 600 API-X65 L450 W.T 5.2mm 150 mm dia. . Stage 3rd. RD-0 to 1200 API-X65 L-450 W.T 5.2mm 150mm dia.
Stage 2nd. RD-0/600 to 3000 API-X65 L-450 W.T 4.80 mm 150 mm dia. . Stage 3rd. RD-0/1200 to 4200 API-X65 L-450 W.T 4.80mm 150mm dia.
Laying, testing and commissioning at site in trenches bevelled ended BIS marked GI Heavy conforming to IS 1239 or it equivalent latest with uptodate ammendments of following dia of Heavy/ Medium class, having wall thickness and weight per Rmt. as mentioned below and capable of withstanding required test pressure as presscribed in BIS/IS)code, in random lengths of 5.5 to 6.5mtr. The pipes ends shall be bevelled suitable for butt welding, including the cost of ointing with butt welding confirming to IS 816-1969 or latest as appliable and with upto date ammendments (leak proof) in three layers at site of work with welding rods of Advani/Oerliken make/ISI marked(welding rods 3mm to 4mm) and all allied accessories whatever required for welding at site, tail pieces, tees bends & other specials manufactured from parent pipes as applicable to the particular reach & of approved specificatin as per site conditions and cutting of pipes wherever required as per site requirment i/c carriage in all leads & lifts and as directed by the Engineer-in-charge.
Zone 1st Stage 2nd Heavy Class FT 17 150mm dia. RD 0/3000-0/4200
Zone 1st Stage 2nd Medium Class FT 5 150mm dia. RD 0/4200-0/5000
Zone 1st Stage 3rd Heavy Class FT 17 150mm dia. RD 0/4200-0/5100
Zone 1st Stage 3rd Medium Class FT 5 150mm dia. RD 0/5100-0/5400
Gravity Line node 2-3 Stage 1st Medium Class FT 5 125mm dia. RD 0/0-0/2350
Gravity Line node 5-6 Stage 3rd Medium Class FT 5 100mm dia. RD 0/0-0/4600
Providing MS Flange (in Pairs) for joints of API pipe mentioned as below and same shall conform to BIS 6392-1971 ( Latest with uptodate ammendments ) including the cost of Nut and Bolts of Required size 3mm thick compressed asbestos fibre/ synthetic rubber gasket conforming to relevant BIS Standards the rates also include entire carriage of Flange and welding of one flange in three layers other Flange consider in butt welding testing , complete to the best satisfaction and direction of engineer -in Charge.charge.
Zone 1st Booster Stage and Stage 1st. API-X56 FT 5 1 Pairs 200 mm dia.
Stage 1st. API-X56 FT 28 6 Pairs 200 mm dia.
Stage 1st. API-X56 FT 23 6 Pairs 200 mm dia.
Stage 1st. API-X56 FT 17 6 Pairs 200 mm dia.
Stage 1st. API-X56 FT 11 6 Pairs 200 mm dia.
Stage 1st. API-X56 FT 5 8 Pairs 200 mm dia.
Stage 2nd API-X65 FT 34 12 Pairs 150 mm dia.
Stage 2nd API-X65 FT 28 18 Pairs 150 mm dia.
Stage 3rd API-X65 FT 34 18 Pairs 150 mm dia.
Stage 3rd API-X65 FT 28 24 Pairs 150 mm dia.
Providing MS Flange (in Pairs) for joints of G.I. pipe mentioned as below and same shall conform to BIS 6392-1971 ( Latest with uptodate ammendments ) including the cost of Nut and Bolts of Required size 3mm thick compressed asbestos fibre/ synthetic rubber gasket conforming to relevant BIS Standards the rates also include entire carriage of Flange and welding of one flange in three layers other Flange consider in butt welding testing , complete to the best satisfaction and direction of engineer -in Charge.
Zone 1st Stage 2nd and 3rd Heavy Class FT 17 21 Pairs 150 mm dia.
Stage 2nd and 3rd Medium Class FT 5 11 Pairs 150 mm dia.
Gravity Line node 2-3Stage 1st Medium Class FT 5 24 Pairs 125 mm dia.
Gravity Line node 5-6 Stage 3rd Medium Class FT 5 33 Pairs 100 mm dia.
HILL CONSTRUCTION AND ENGINEERING CO. SOLAN
H. C. Bansal Engg. & Contt.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .