S&T work for addition/alteration in existing EI and Provision of 01 full rake Goods Handling Line at Jangbahadur Ganj Station on RAC-SPC section and Utility shifting in c/w Upgradation/Modernisation of infrastructure at Kaurha & Roza line no. 05 & 06 stations goods sheds and Construction of new ROB in lieu of existing dilapidated ROB no.1142-A at Km.1397/18-20 on LKO-MB section over Moradabad Division of Northern Railway.
287-SIG-C-TKJ-79-26~NR
287-SIG-C-TKJ-79-26
Open
Works - General
8 Months
Moradabad, Uttar Pradesh
₹0
₹3.8 L
17 Jun 2026
26 May 2026
3 Jun 2026
0 Description:- Installation, wiring, programming, testing & commissioning icw Modification /alteration/augmentation in the existing EI (KYOSAN) system (at JBG Station) of Hot stand by Arc as
applicationlogic programmes to suit Modified SIP. 2. Alteration in existing Interface Circuit diagram to suit Modified SIP. 3. Factory Acceptance Test of EI system. 4. Site Accpetnce Test of EI System. 5. Installation , Testing & Commissioning of EI System as per Modified SIP. 6. Supply of ASMADE Documents.
2 Description:- I/O Card, PI03C(PIO2-LOG). Inspection: RDSO (Item interlinked with item no.1)
accessories necessary to make the EI system functional as per approved signaling plan. (Item interlinked with item no.1)
Description:- "Supply of ""As built"" Documents. (i) Completion Documents as per condition of Contract. (6 Sets for each EI) (ii) Supply of documents as per Technical specification Para - 10.2 of
quality paper, laminated, properly bound in steel clip jaw file with cushioned cover.(ii) Software back up of complete set in the form of Pen Drive. (iii) One complete set of tracings.(iv) Design through CAD (v) Drawings in A3 and plans in bigger size. (six sets). (6 Sets for each EI). (1 Set=1 Set per Station) (Inspection: SSE/DandD)"
DYCSTE-C-TKJ-S AND T/NORTHERN RLY
Measuring Instruments for technicians / Jr. Engineers for Testing, Maintenance at Site and Instuments and Tool Kit required for trouble Shooting and repair at site. Note: Details of tool kit item is enclosed in Annexure -V/Vol.II of tender document. (1 Set=1 Set per Station) (Inspection : Consignee) "
Description:- Training for Rly. Tech./JE/SE/SSE/Officer by OEM in installation, testing and commissioning, maintenance and trouble shooting of EI system complete including supply of
OEM. All arrangements including classroom, lab, equipment, measuring instruments etc. required for the training should be satisfactorily arranged by the contractor at their own cost. (Inspection/Supervision : Site Engineer)
Description:- Fabrication, supply and fixing of relay racks of size 2200mmx690mm (as per approved Drg. No. NR/SandT/CON/4-3/97A) made of angle iron size 45mmx45mmx6mm alongwith outer frame made of angle iron size 65mmx65mmx8mm, fitted with M.S. squares bars duly
units/ECRs/HMUs. All fixing material like antilting device, hylam sheets if required, bolts and nuts, washers, insulators, shoe, angle irons, flats, L-bolts, Catenary wires and cement concrete etc. will be supplied by the contractor. This includes cleaning, priming by red oxide, painting and description etc. with ISI mark paints. (Inspection: Site Engineer)
Description:- "Fabrication, supply and fixing of cable termination board of size 2200mmx900mm as per Drg. No. NR/SandT/CON/4-1/97A made of angel iron size 40mmx40mmx5mm alongwith outer frame made of angle iron size 65mmx65mmx8mm duly fitted with Bakelite sheet (HYLAM MAKE or similar ) of size 6mm thick. This also includes fixing of ARA terminals/strips/Wago connectors and
jamming of armour of cables, each cable in the hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering. All the fixing materials like bolts, nuts, washers, Insulators, shoe, angle irons, flats, L- bolts, Catenary wires and cement concretes etc. will be supplied by the contractor. This includes cleaning, priming by red oxide, painting and description etc. with ISI mark paints. (Inspection : Site Engineer) "
Description:- Fabrication, supply and fixing of scaffolding /cable carrier made of angle ironof Size
between two flats will be 25cm or less as per site requirements allthe fixing materials i.e nut, bolt washer, insulators, cement concrete etc will be supplied by the contractyor . This includes insulating flat strips, cleaning priming by Red oxide, painting by ISI mark paint. (Inspection : Site Engineer)
Description:- "Wiring of relays in relay room/relay huts as per appd wiring diagrams. All wiring
dressing, bunching , lacing and fixing of relay bases. (Cables and wires for wiring will be supplied by Railway). (Inspection : Site Engineer) "
Description:- Fabricating, writing and fixing of description boards made of ply 6mm thick with
having alluminium angle size of 25.4mmx25.4mmx3.15mm on all four sides as per instruction of Engineer at site. All the materials to be supplied by contractor. (Inspection : Site Engineer)
1.25" thick supported on angles 2" x 2" x .25" on three sides. This includes painting of angles and varnishing of shelves. All materials to be supplied by the contactor. (Inspection : Site Engineer)
Description:- Supply of electric fuse complete with fuse block(base) for Railway signalling non-
78/2006 and fuse block made of PBT/Polycarbonate as per IRS: S-75/2006 (Rev-2 and Amd 2 ) and drg no. 23748 (IRS) Alt.4 or latest. Fuse block shall be suitable for round head type fuses. Rating : 2Amp/4Amp /10 Amp/16Amp'. (Inspection : RDSO)
Description:- Supply, installation and wiring of Earth leakage detector (12 Channels) for monitoring
or latest and stipulations of tender docment. Installation to be done by OEM. A certificate to be submitted by the contractor.(Inspection : RDSO for supply portion and Installation by Site Engineer)
DYCSTE-C-TKJ-S AND T/NORTHERN RLY
or Rishabh make capable to measure from (0.1mv/0.01ma) AC/DC upto 50Amp(AC/DC), 600V(AC/DC) and 0.1 ohms- 40M ohms suitable for measurement of Freq., capacitance complete with Manual, leads, battery and holster etc. (Inspection : Consignee)
Description:- Supply of tool kit for JE/SE/SSE for Maintenance as per tech spec. given below: (1) Digital Multi Meter suitable for axle counter ranges 20 Amp AC/DC make protek 506 or similar- 1 no. (2) Digital clamp Multi Meter range up to 100 Amps for AC/DC current make SEW or similar - 1 no. (3) Leather Tool Bag for keeping tool kit -1 no. (4) Plier Sealing with sealing code bit -1 no. (5) Plier Wire Cutting 8" make Taparia or similar -1 no. (6) Nose Plier 4" make Taparia or similar -1 no. (7) Wire
(10) Soldering Iron 230V AC/65 watt -1 no. (11) Soldering Iron 230V AC/35 watt with diffrerent type replacement soldering head - 1 no. (12) Soldering Iron 110V AC/35 watt -1 no. (13) Mesuring Tape steel 30 meters - 1 no. (14) Measuring Tape steel 5 meters - 1 no. (15) Rechargable Torch Superior quality -1 no. (16) File Flat 8" long - 2 nos. (17) File Round smooth 8" long - 2 nos. (18) File Flat Bsterred 8" long - 2 nos. (19) Electric Drill Machine Portable 6mm make wolf or similar -1 no.(20) megger 100V DC (Inspection : Consignee)
Description:- Supply fixing and wiring of fuse auto changeover system (FACS main system) as per RDSO/SPN/209/2012 Rev. 2.0 with latest amendments. One automatic changeover unit comprise 32 nos of external Non Deteriorating Type or 'G' type fuses of various Ampere Rating, working voltage-
fuses in one card. .Installation , wiring, Testing and commissioning of Fuse Alarm System,it consists of fixing of modules of fuse alarm system on existing relay rack, wiring from existing fuses to modules, soldering, lacing etc will be supplied by the contractor. Installation to be executed without affecting the functioning of the existing Circuits/Gears (Inspection : RDSO for supply portion and Installation by Site Engineer)
Description:- Supply of 4 conductor dis-connect terminal block for test and measurement 0.8
carreir rail DIN 35 front entry cage clamp connection Grey wago or similar as per RDSO/SPN/189/2004 Ver.3.0 or latest. (Inspection : RDSO)
Wago or similar as per RDSO/SPN/189/2004 Ver.3.0 or latest. (Inspection : Consignee)
RDSO/SPN/189/2004 Ver.3.0 or latest. (Inspection : Consignee)
similar as per RDSO/SPN/189/2004 Ver.3.0 or latest. (Inspection : Consignee)
Description:- "Prep. of Station Working Rule Diagram, Cable route plan, Cable core chart, Track jumpering plan, Power supply arrangement plan based on station specific load calculation for indoor and out door , Circuit termination chart, Cable termination chart in relay room ,relay hut (if applicable) and location boxes, Location wiring plan, Cable insulation chart and register, Track circuit
Contact analysis chart , Outdoor circuits,pull sheets,goomtie plans,diagrams. temp. plans required for execution of PNI/NI and other outdoor diagram and obtaining approval of the Engineer as per following :- (i) Supply of 6 copies of completion set of superior quality paper, laminated, properly bound in steel clip jaw file with cushioned cover.(ii) Software back up of complete set in the form of Pen drive (32 GB). (iii) One complete set of tracings.(iv) Design through CAD(v) Drawings in A3 and plans in bigger size (six sets) in folders. (Inspection : SSE/C/DandD)"
Description:- Excavating and refilling of trench in Normal Soil to the level of ground with rammed
per signalling and cable plan. It also includes clearance of rooots of trees and bushes. (Inspection : Site Engineer)
No.NR/SandT/CON/1-1/97A as per instructions of the site Engineer. (Inspection : Site Engineer)
DYCSTE-C-TKJ-S AND T/NORTHERN RLY Description:- Supply, laying and fixing of HDPE double Wall Corrugated (DWC) Duct as per as per 25 RDSO Specification No. RDSO/SPN/204/2011 Ver. 1.1 With Amndt-1 (outer dia 120mm in 6m st. length with one coupler for every 6m length). All the materials cement, sand etc. are to be supplied by the contractor. This include brick work and other arrangements required to secure the pipe as per specifications, drawings and stipulations of tender documents and as per approved cable route plan including road crossing/platform/track crossing and for bridges and culverts etc. (Inspection : Consignee for supply portion and Installation by Site Engineer)
Description:- Installation of 120mm/90mm dia HDPE double Wall Corrugated (DWC) Duct as per as per RDSO Specification No. RDSO/SPN/204/2011 Ver. 1.1 With Amndt-1 (outer dia 120mm in 6m st.
by the contractor. This include brick work and other arrangements required to secure the pipe as per specifications, drawings and stipulations of tender documents and as per approved cable route plan including road crossing/platform/track crossing and for bridges and culverts etc. (Inspection : Site Engineer)
Description:- Supply and fixing of G.I. pipe 75mm/80mm dia, 3mm thick as per spec no IS-1239, perforated at a distance of 20 CM or less of required length at culverts/ bridges/along the cuttings,
office/other buildings suitably fixing it to the wall and at both ends. G.I. clamps of M.S. flats bolts and nut, to be supplied by the contractor. Inspection : Consignee for supply portion and Installation by Site Engineer)
Description:- All work of horizontal boring and trenchless cabling along with supply,transpotation and insertion of double wall corrugated pipe -( ISI marked ) conforming to RDSO Spec no.
instruction of site engg. by using pipe of size 120 mm outer dia, 103.5 mm inner dia in which required number of cables to be crossed. This includes laying of cables in trench. The depth of horizontal boring should be minimum 1.0 m from rail flange/road level. (Inspection : RITES for supply portion and Installation by Site Engineer)
NR/SandT/CON/1-1/97C and as per cable route plan approved by Railways and meggering of cable before and after its laying of all type of outdoor cables. (Inspection : Site Engineer)
includes supply and provision of jointing kit. (Inspection : Site Engineer)
Description:- Supply and installation of RFID electronic marker for S&T underground cable wlth
chip,later recordable by electronic marker locator during locating(1O cm diameter with floating coil to keep detection circuit always Horizontal for better detection) which can be buded to depth of 5ft Placing in trench. Inspection RITES
/020, dated 31.10.11. The marker shall be fixed at various places of cable route as per instruction of Engg. At site. (Inspection: Site Engineer)
Description:- Testing and meggering of all types of outdoor cables after its laying and termination
report for core to core and core to earth on prescribed proforma for each core of the cable seperately. This also include dressing and lacing of cable on both ends. Proforma for testing and material for lacing to be supplied by the contractor. (Inspection : Site Engineer)
34 Description:- Supply of Megger 500V DC Philips or similar make. (Inspection : Consignee)
Description:- Casting, concreting and curing of foundation of size (1160mmx760mm) at surface and 650mm deep as per approved Drg.No.NR/SandT/CON/2-7/97. It includes erection of single apparatus case ,A layer of 3 mm of bitumen compound has to be provided between foundation and
cement,coarse sand,aggregate,bitumen compound and anchor bolt shall be supplied by contractor . App. Case single will be supplied by Railway. Contractor is required to execute all type of repair Works of foundations if required during inserting the cable for termination. (Inspection : Site Engineer)
36 DYCSTE-C-TKJ-S AND T/NORTHERN RLY 36 Description:- Supply of single app.case steel RE with E type lock and key ward no.42 and handle as per drg. No. RE/SandT/ALD/SK/219/82 and 221/82 with Alt.B. (Inspection : RITES)
Description:- Preparation of App. Case single involving wiring of relays. Preparation and fixing of bakelite hylum sheet 910x800x6mm and backelite shelf 900x450x10mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location boxes secured by nuts and bolts.This includes fixing of fuses, ARA terminal, Q series relays and other type relays on square bars fixing and jamming of cables with 2 inch thick salwood plank provided at the bottom. This will include
through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering.Wiring description for terminal drawing of circuits, inside app. Case. Painting from out side as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including Backelite shelf, hylum board, salwood plank, angle iron square bar, wire and wiring material catenary wires , nuts and bolts and other items shall be supplied by the contractor. Relays, ARA terminals, fuse with base only shall be supplied by the Railways. (Inspection : Site Engineer)
Description:- Preparation of App. Case single not involving wiring of relays. Preparation and fixing of bakelite hylum sheet 910x800x6mm and Backelite shelf 900x450x10mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location boxes secured by nuts and bolts.This includes fixing of fuses, ARA terminal and fixing and jamming of cables with 2 inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable
location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering.Wiring description for terminal drawing of circuits, inside app. Case. Painting from out side as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including Backelite shelf, hylum board, salwood plank, angle iron square bar, wire and wiring material , catenary wires , nuts and bolts and other items shall be supplied by the contractor. ARA terminals,fuse with base only shall be supplied by the Railways. (Inspection : Site Engineer)
Description:- Preparation of App. Case single to be used as battery box.(not requiring shelf and hylum of size 910x150x6mm only is reqd.). Preparation and fixing of bakelite hylum sheet 910x150x6mm. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location boxes secured by nuts and bolt sthis includes fixing of fuses, ARA terminal and jamming of cables with 2 inch thick salwood plank provided at the bottom. This will
cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering.Wiring description for terminal drawing of circuits, inside app. Case. Painting from out side as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including hylum board, salwood plank, wire and wiring material , catenary wires, nuts and bolts and other items shall be supplied by the contractor. ARA terminals only shall be supplied by the Railways. (Inspection : Site Engineer)
Description:- Casting, concreting and curing of foundation of size (670mmx760mm) and 650mm deep as per Drg.No.NR/SandT/CON/2. 8/97 it includes erection of Apparatus case half. A layer of 3
ingress of water in the base of location box . All material such as cement,coarse sand,aggregate,bitumen compound and anchor bolt shall be supplied by contractor . App. Case half will be supplied by Railway. Contractor is required to execute all type of repair Works of foundations if required during inserting the cable for termination. (Inspection : Site Engineer)
handle as per drg.no. RE/SandT/ALD/SK/220/82 and 221/82 with Alt.B. (Inspection : RITES)
DYCSTE-C-TKJ-S AND T/NORTHERN RLY Description:- Preparation of Apparatus Case half involving wiring of relays. Preparation and fixing
piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location box secured by nuts and bolts. This includes fixing of fuse ARA terminal, Q series relays and other type of relays on square bars, fixing and jamming of cable with 2 inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in the hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering. Wiring description for terminal drawing of circuits, inside app. Case. Painting from out side as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including Backelite shelf, hylum board, salwood plank, angle iron square bar, wire and wiring material catenary wires, nuts and bolts and other items shall be supplied by the contractor. Relays, ARA terminals,fuse with base only shall be supplied by the Railways (Inspection : Site Engineer)
Description:- Preparation of App. Case half not involving wiring of relays. Preparation and fixing of Bakelite hylum sheet 450x800x6mm and Backelite shelf 450x450x10mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location box secured by nuts and bolts. This includes fixing of fuse ARA terminal and fixing and jamming of cable with 2 inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in the
location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering.Wiring description for terminal drawing of circuits, inside app. Case. Painting from out side as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including Backelite shelf, hylum board, salwood plank, angle iron square bar, wire and wiring material with bases, catenary wires, nuts and bolts and other items shall be supplied by the contractor. ARA terminals, fuse with base only shall be supplied by the Railways. (Inspection : Site Engineer)
Description:- Preparation of App. Case half as Battery Box (not requiring shelf and hylum of size 450x150x6mm only is reqd.) Preparation and fixing of bakelite hylum sheet 450x150x6mm Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location box secured by nuts and bolts. This includes fixing of fuse ARA terminal and fixing and jamming of cable with 2 inch thick salwood plank provided at the bottom. This will include opening,
salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering.Wiring description for terminal drawing of circuits, inside app. Case. Painting from out side as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including hylum board, salwood plank, angle iron square bar, wire and wiring material catenary wires, nuts and bolts and other items shall be supplied by the contractor. ARA terminals only shall be supplied by the Railways. (Inspection : Site Engineer)
with alteration in wiring shall be provided by the contractor. Relays, ARA terminals only shall be supplied by the Railways. (Inspection : Site Engineer)
No.IRS-S-75/2006 (Rev.2) and IRS drawing No. SA-23741A(Alt.4), SA23745(Alt.5) ,SA-23746 and SA- 23756(Alt.3) . (Inspection : RDSO)
Description:- Casting, concreting and curing of foundation for main signal of size
Drg. no. NR/SandT/CON/2.1/97 all material such as anchor bolts, cement, coarse sand aggregate to be supplied by contractor. (Inspection : Site Engineer)
spec. IRS-S-6-81, Rev-3 or latest . (Inspection : RITES)
spec. IRS-S-6-81, Rev-3 or latest.(Inspection : RITES)
Description:- Supply of 2 Aspect colour light signal unit complete with-out holders, lamps, lenses 50 and signal transformer as per RDSO Drg. No. SA-23003 A/M (Adv), Alt-9 or latest . Specification no. IRS:S-26/64 Rev 1 or latest. (Inspection : RITES) DYCSTE-C-TKJ-S AND T/NORTHERN RLY
Description:- Supply of 3/4 Aspect colour light signal unit complete with-out holders, lamps, lenses
2302A/M(Adv), Alt 9 or latest respectively. Specification no. IRS:S-26/64 Rev 1 or latest. (Inspection : RITES)
latest complete with hoods and offset bracket 5 1/2" as per . specn.no.IRS-S-66/84 (Amd-1) or latest, drg.no. SA 23402(Adv), Alt.-2 or latest. (Inspection : RITES)
Description:- Installation, erection, wiring of 2 aspect color light signal. Fixing of CLS surface base, bolting on the foundation. Erection of CLS post with signal unit on the top or on an off-set bracket and fitting ladder and guard to the post at the top. Concreting ladder base and embedded into the ground with supporting bracket in the middle, blanking of the ladder for a distance of 1 feet between the height 6' 9" and 7' 9" from the rail level by MS angle and MS sheet 6mm thick wherever required. This includes provision of wooden (SAL) cross arm 1 mtr x 1 mtr for CLS unit prior to the
wiring the CLS unit and focusing the signal. Elevation and distance of foundation from track shall be in accordance with schedule of dimension for Indian Railways and as per NR practice. All items for the above Works except Signal unit, LED signal, Signal post, Base and Ladder shall be supplied by the contractor including but not limited to the following: i) "U" bolt for offset brackets,ii) Wooden cross arm 1 mtr. x 1 mtr.,iii) MS angle and MS sheet for blanking of ladder,iv) Supply and fixing of signal number plate (retro reflective) with complete fittings as per standard railway practice. v) Wire mesh guard, lock for unit if required, nuts, bolts etc for the following: (Inspection : Site Engineer)
Description:- Installation, erection, wiring of 3/4 aspect color light signal. Fixing of CLS surface base, bolting on the foundation. Erection of CLS post with signal unit on the top or on an off-set bracket and fitting ladder and guard to the post at the top. Concreting ladder base and embedded into the ground with supporting bracket in the middle, blanking of the ladder for a distance of 1 feet between the height 6' 9" and 7' 9" from the rail level by MS angle and MS sheet 6mm thick wherever required. This includes provision of wooden (SAL) cross arm 1 mtr x 1 mtr for CLS unit prior to the
wiring the CLS unit and focusing the signal. Elevation and distance of foundation from track shall be in accordance with schedule of dimension for Indian Railways and as per NR practice. All items for the above Works except Signal unit, LED signal, Signal post, Base and Ladder shall be supplied by the contractor including but not limited to the following: i) "U" bolt for offset brackets, ii) Wooden cross arm 1 mtr. x 1 mtr., iii) MS angle and MS sheet for blanking of ladder,iv) Supply and fixing of signal number plate (retro reflective) with complete fittings as per standerd railway practice. v) Wire mesh guard, lock for unit if required, nuts, bolts etc (Inspection : Site Engineer)
Description:- "Installation, erection and wirng of 2/3/4 aspect LED lit colour light signal including 1/2/3/4/5/6 way Jn. type/Stencil/Theatre type route indicator Fixing of CLS surface base, bolting on the foundation. Erection of CLS post with signal unit on the top or on an off-set bracket and fitting ladder and guard to the post at the top. Concreting ladder base and embedded into the ground with supporting bracket in the middle, blanking of the ladder for a distance of 1 feet between the height 6' 9" and 7' 9" from the rail level by MS angle and MS sheet 6mm thick wherever required. This includes provision of wooden (SAL) cross arm 1 mtr x 1 mtr for CLS unit prior to the commissioning, fixing of LED aspect, current regulator and hoods of CLS unit, terminating cables, wiring the CLS unit
schedule of dimension for Indian Railways and as per NR practice. All items for the above Works except Signal unit, LED signal, Signal post, Base and Ladder shall be supplied by the contractor including but not limited to the following: i) "U" bolt for offset brackets, ii) Wooden cross arm 1 mtr. x 1 mtr., iii) MS angle and MS sheet for blanking of ladder,iv) Supply and fixing of signal number plate (retro reflective) with complete fittings as per standerd railway practice. v) Wire mesh guard, lock for unit if required, nuts, bolts etc . This also includes fixing of route indicator on the top of the signal post or on offset bracket including fixing of offset bracket, wiring the whole unit, focussing of signal and route indicators. All items for installation and erection to be supplied by the contractor. Wiring and other fixing material, 'U' bolts will also be supplied by the contractor. (Inspection : Site Engineer)"
drg.no.SA 24351-52(Adv) or latest .no.IRS-S-23/88. or latest. (Inspection : RITES)
without holders bulbs etc. to drg.no.SA 23840(adv) to SA 23848 (adv), spec no .IRS-S-23/88 Dependent post type. (Inspection : RITES)
DYCSTE-C-TKJ-S AND T/NORTHERN RLY Description:- Installation, erection and wiring of LED lit calling-on/dependent shunt signal
Which also includes fixing of stencil and hoods, wiring and focussing of the signal. Offset brackets, calling on signal/shunt signal complete will be supplied by Railways. U-bolt for offset bracket and wire and wiring material will be supplied by contractor. (Inspection : Site Engineer)
Description:- Casting, concreting and curing of foundations for shunt signal/ F marker of size
no. NR/SandT/CON/2-1/97A. All material such as cement, coarse sand, aggregate and foundation bolts will be supplied by contractor. (Inspection : Site Engineer)
mounting socket 90mm dia without holders bulbs etc. to drg.no.23840 adv. Or latest specs.no.IRS-S- 23/88 Independent post type. (Inspection : RITES)
Description:- Installation, erection and wiring of independent position light shunt signal/ F
hood and wiring of shunt unit and focussing the signal. All material such as wire,nutand bolt etc. will be supplied by the contractor. (Inspection : Site Engineer)
Description:- Fabrication, Supply and fixing of retroreflective P/G/C/A markers with complete
sheet, MS angle. Nut and bolts will be supplied by the Contractor. The P and G markers shall be as per Drg. No.S 23456(Adv) and SA 23477(Adv) respectively. (Inspection : Site Engineer)
Description:- Casting, concreting, curing of foundations of size (400mmx300mm) at surface and 1000mm deep and erection of retroreflective SLB/BSLB/SB/ calling on boards/stop dead
provisions of SEM. Supply of SLB/BSLB/SB/ calling on boards/stop dead boards/ GoodsWarning Board/ PassangerWarning Board as per approved Drg. No.SA-2373 or latest will be Supplied by the contractor. (Inspection : Site Engineer)
Description:- Supply of electric point machine (IRS Type) (AC Immunity 160 VAC) Non Trailable to
box and slides for lock and detector as per specification no. IRS-S-24/2002 with Ammendment-1 or latest. (More than 1200 Mtr operations required) Inspection : RDSO
Description:- Fabrication and Supply of complete set of point rodding for point machines of IRS
bracket required coal Bengal for smithy work, all type of nuts and bolts and ,washers and spring washers ,Lugs as reqd also to be supplied by contractor with each set. (Inspection : Consignee)
of Insulation plate - 01 No. Ferrule - 02 Nos. Washers - 04Nos. (Material Nylon 66). (Inspection : Consignee)
Insulation plate - 01 No. Ferrule - 02 Nos. Washers - 04Nos. (Material Nylon 66). (Inspection : Consignee)
Description:- "Fixing, wiring, testing and adjustment of point machines as per standard practice. It also includes :- i) Fixing of switch extension 'P' bracket/'D' bracket, providing insulation for switch extension bracket, fixing ground connections, adjusting the correct opening of switches and adjusting the point machine with crank handle. ii) Wiring inside the point machine, wiring of JB with lock and key as per drawing, provided with terminal strips for cable terminations. iii) Supply and fixing of GI pipes with flange for taking cable in to point machine and jn. Box through gland/GI pipe. iv) Complete installation of point insulation , GI pipe, gland pipe, angle iron of size
stretcher bar 90R/52kg/60kg as per . drg.no.SA-23172 (adv.) Alt.1 will be done by the contractor. v) Smithy and fitting work required at site for complete installation of Gauge tie plate and insulation of GTP as per approved Drg.no.NR/SandT/CON/7-6/97 and william stretcher bar (if reqd.) will be done by the contractor. Machine shall be overhauled by contractor if required. vi) This includes removal of existing gears and fixing the machine at raised level on channel as per standard practice to avoid flooding wherever required. vii) Supply of point machine, ground connections of electric point machine, Jn. box , non insulated GTP and CTP extension plate, and stretcher bar with insulation material shall be made available by the Rlys. (Inspection : Site Engineer)" DYCSTE-C-TKJ-S AND T/NORTHERN RLY
Description:- Supply, installation and wiring complete KLCR and its box in ASM office /LC Gate or fixing in L-Box. Supply of Key Lock Relay(KLCR) type TMA 24V DC with 2F/2B contact configuration with different wards combinations as per RDSO Specificatins. Supply, installation, wiring of heavy duty push button, LED indicator on MS sheet as per N.R. practice for crank handle locking. This work
and 3 Nos. of 6 I cells as per instructions of the Site Engr. This includes all materials such as heavy duty push button, LED indicator (10mm), MS sheet of 4.5mm thick, nuts and bolts, fixing materials for the magneto telephone including standard Battery Box and 3 Nos. of 6 I cells and wiring materials to be supplied by contractor. (Inspection : RDSO for supply portion and Installation by Site Engineer)
Description:- Fabrication and installation of illuminated indication Diagram Board of salwood with white sunmica top having aluminum angle of size 1"x1"x1/8" on all 4 sides duly painted for station
The indications for signal, slot etc shall be provided near the signal painted on the yard diagram. It includes of all materials like LED, Holders ,wires etc will be supplied by the contractor. Inspection Consginee
Description:- Supply and fixing of 50 mm wide Red/Yellow coloured retro reflective highlighter
specification for fixing on BSLB/SLB boards/Stop signals/LC gates Make 3M India Ltd or equivalent. Inspection Consginee
no. IRS: 89/2013 (Amd 1) or latest from RDSO appd. Firm. (Inspection : RDSO)
latest with micro porous vent plugs cum floats with inter cell connectors, nuts,bolts,washers etc. (Inspection : RDSO)
Description:- Installation of Berthing and straight DC track circuits to suit RE area as per std. Practice. This will include following as per site requirement :- (a) Drilling of holes 7.2 mm dia or size as required provision of continuous G.I. wire bonding on switch portion and crossing of point with two bonds wires and two clips duly fastended with fish plates and bolts at each joints including transverse bonding with rope wire. 8 SWG G.I. soft bond wire, Channel bond pins and all other material required will be supplied by contractor. (b) Jumpering from rail to rail or to track lead junction box including polarity jumpers/cables as per track jumpering/ insulation diagram. This includes , terminating the jumpers in the TL JB and fixing the jumper on the sleeper as per instructions of Engr. at site. (c) Fixing of insulated block joints complete with provision of skimmed fish plate. Fish plates shall be supplied by the Railways but skimming to be done by contractor.
No.(NR/SandT/CON/3.2/97) along with concrete foundation and plastering on both ends i.e. T.F. and TR end and for polarity changers as per the track jumpering/ insulation diagram. All material for fixing including angle iron shall be supplied by the contractor. This also includes supply and fixing of TLJBs with provision of M-6 terminals. TLJB to be written with track circuit number. (e) Prov. and wiring in the app. Cases/relay huts of T.F. battery charger, TF resistance 30 Ohms, track relays, choke B type (at Feed End and Relay End) and batteries as per the standard practice using fuses and terminals. This all include supply of all material by contractor except supply of TF battery charger, batteries, relays.Supply of TF battery charger, batteries, relays will be done by the Railway. (f) Commissioning of track circuits as per prov.of para of IRS specn. S-36/87 Amd 2. This includes adjustment of track feed resistance, testing with train shunt resistance. This also includes preparation of track history cards. Track history card should be supplied by the contractor. (Inspection : B- type Choke, track resistance and fuse by RDSO
DYCSTE-C-TKJ-S AND T/NORTHERN RLY Description:- Installation of Point track circuit having single point (excluding traps) DC track circuits to suit RE area as per std. Practice. This will include following as per site requirement:- (a) Drilling of holes 7.2 mm dia or size as required provision of continuous G.I. wire bonding on switch portion and crossing of point with two bonds wires and two clips duly fastended with fish plates and
bond pins and all other material required will be supplied by contractor. (b) Jumpering from rail to rail or to track lead junction box including polarity jumpers/cables as per track jumpering/ insulation diagram. This includes terminating the jumpers in the TL JB and fixing the jumper on the sleeper as per instructions of Engr. at site. (c) Fixing of insulated block joints complete with provision of skimmed fish plate. Fish plates shall be supplied by the Railways but skimming to be done by contractor. Supply of insulation materials for insulated block joints will be supplied by Railway. (d) Fixing of TL JBs as per drg. No.(NR/SandT/CON/3.2/97) along with concrete foundation and plastering on both ends i.e. T.F. and TR end and for polarity changers as per the track jumpering/ insulation diagram. All material for fixing including angle iron shall be supplied by the contractor. This also includes supply and fixing of TL JBs with provision of M-6 terminals. TLJB to be written with track circuit number. (e) Prov. and wiring in the app. Cases/relay huts of T.F. battery charger, TF resistance 30 Ohms, track relays, choke B type (at Feed End and Relay End) and batteries as per the standard practice using fuses and terminals. This all include supply of all material by contractor except supply of TF battery charger, batteries, relays.Supply of TF battery charger, batteries, relays will be done by the Railway. (f) Commissioning of track circuits as per prov.of para of IRS specn. S- 36/87 Amd 2. This includes adjustment of track feed resistance, testing with train shunt resistance. This also includes preparation of track history cards. Track history card should be supplied by the contractor. (Inspection : B- type Choke, track resistance and fuse by RDSO
Description:- Installation of Point track circuit having double point (excluding traps) DC track circuits to suit RE area as per std. Practice. This will include following as per site requirement:- (a) Drilling of holes 7.2 mm dia or size as required provision of continuous G.I. wire bonding on switch portion and crossing of point with two bonds wires and two clips duly fastended with fish plates and bolts at each joints including transverse bonding with rope wire. 8 SWG G.I. soft bond wire, Channel bond pins and all other material required will be supplied by contractor. (b) Jumpering from rail to rail or to track lead junction box including polarity jumpers/cables as per track jumpering/ insulation diagram. This includes terminating the jumpers in the TL JB and fixing the jumper on the sleeper as per instructions of Engr. at site. (c) Fixing of insulated block joints complete with provision of skimmed fish plate. Fish plates shall be supplied by the Railways but skimming to be done by
Fixing of TL JBs as per drg. No.(NR/SandT/CON/3.2/97) along with concrete foundation and plastering on both ends i.e. T.F. and TR end and for polarity changers as per the track jumpering/ insulation diagram. All material for fixing including angle iron shall be supplied by the contractor. This also includes supply and fixing of TL JBs with provision of M-6 terminals. TLJB to be written with track circuit number. (e) Prov. and wiring in the app. Cases/relay huts of T.F. battery charger, TF resistance 30 Ohms, track relays, choke B type (at Feed End and Relay End) and batteries as per the standard practice using fuses and terminals. This all include supply of all material by contractor except supply of TF battery charger, batteries, relays.Supply of TF battery charger, batteries, relays will be done by the Railway.(f) Commissioning of track circuits as per prov.of para of IRS specn. S- 36/87 Amd 2. This includes adjustment of track feed resistance, testing with train shunt resistance. This also includes preparation of track history cards. Track history card should be supplied by the contractor. (Inspection : B- type Choke, track resistance and fuse by RDSO
miniature tractive armature with 2F/1B contacts as per BRS : 939A or latest amendments if any, BRS :966 Append F2, IRS-S-34 and IRS-S-23 and IRS-S-60 (as applicable). (Inspection : RDSO)
Description:- Charging of lead acid secondary cells of 80/120AH capacity as per standard charging
conforming to latest IRS specs and distilled water as per IRS specs will be supplied by contractor. This also includes installation of secondary batteries, their interconnection and writing work. (Inspection : Site Engineer)
graded acid with mounting stand in Battery Room/ location boxes. (Inspection : Consignee)
tyco/Raychem/Bourn/Fuzetech/Little Fuse or similar. (Inspection : Consignee for supply portion and Installation by Site Engineer)
DYCSTE-C-TKJ-S AND T/NORTHERN RLY Description:- "Installation, testing and commissioning of High Availability Single Section Digital Axle Counter System complete by OEM or its authorised dealer. The axle counter will be High Availability Single Section type with two detection points and it is possible to install it without trolley
TX and RX coil-2 sets, each set consist of web mounting type 2 Nos. of TX and 2 Nos. of RX. TX and RX shall be supplied by Rly. (b) Mounting of track side digital axle counter Unit-2 Nos. (c) Fixing of vital relays etc. duly wired-2 Nos. (d) Clamping with deflector plate and hardware for mounting of two set of TX and RX coil. (e) Resetting arrangement of each axle counter. (f) All the wiring material required for installation and commissioning shall be arranged by contractor. (g) This also includes integration with existing SGE/Tokenless/Token block instruments were required as per instructions of site engineer. The wire and other wiring material will be arranged by contractor at site. Inspection: Site Engineer"
Description:- "Supply, Installtion and Commissioning of maintenance free earth suitable kit as per RDSO Specification no. RDSO/SPN/197/2008 and Drg No. SDO/RDSO./EandB/001 dated:- 19.09.2008 and Drg No. RDSO/SDO/RDSO./EandB/002 dated:- 19.09.2008. Earthing kit consisting of earthing electrode of 17mm dia as 3m long -01 no 2 MEEB (300mmx25mmx6mm) -o1 no. 3. SEEB (150mmx25mmx6mm) -01 no 4. Earth enhancing compound - 30 kg (minimum). This includes:- Provisiion of earth connection from MEEB to SandT equipment i.e. cable sheath, apparatus case, BPAC, Axle counter, IPS, Data Logger etc. with PVC earth wire of size 10/16/25 sq.mm through
certain locations, it may not be possible to acheive earth resistance of less than 1.0 ohm with one earth electrode /pit due to soil resistivity. In such cases, provision of loop earth consisting of more than one earth pit shall be done, for interconnection of two earth pits copper tape of size( 25mmx2mm) or GI flat of size( 50mmx6mm) shall be provided by the contractor. The number of pits required shall be decided based on the resistance achieved for the earth pits already installed. The procedure mentioned above for one earth pit shall be repeated for other earth pits. The other earth so installed for the purpose of loop earthing arrangement shall be counted as seperate earth. (Inspection : RDSO for supply portion and installation by Site Engineer)"
Description:- Supply and installation of earth electrodes as per std. practice. The item includes digging of pit in earth, 3 Mtrs. deep and fixing earth electrode pipe. Casting of cement concrete enclosures as per drg. No. (NR/SandT/CON/6.4/97). The soil treatement shall be done as per std. pratice. The item includes provn. of mild steel flat of size 35mm x 6mm (as per IRSEM) and nut bolted connection of MS flat with earth electrode. The other end of mild steel flat to be connected to
apparatus case, LC Gate Pedestal, Boom Lock Post, Operating Panel of LC Gate. CT rack / relay racks, other equipments as per the instruction of Engr. at site and IRSEM. Earhting connection location to location,Earth pit to block instrument, CTR/Relay Rack and any other indoor equipment shall be done through cable for which cable shall be provided by Railway. Complete materials such as earth electrodes as per drg. No. ( NR/SandT/CON/6. 3/97), cement, wiring material, nut bolt for connection and mild steel flat of size 35mm x 6mm or 210 sqm as per SEM etc. to be supplied by the contractor. (Inspection : RDSO/RITES for supply portion and Installation by Site Engineer)
Description:- "Dismantling and releasing single signal post which includes dismantling of signal fittings electrical and mechanical both wheel of sorts,GI pipe pullies,pully stakes wire run from cabin
SSE/Sig/C/TKJ or DY.CMM/SSB store depot at SSB as per site supervisoror any other store of northern railway. Note :- Before dismantling joint survey is to be done with the site engr. and report to be submitted to the site engr.1 Job= 1 Signal) (Inspection : Site Engineer)"
Description:- Dismantling and releasing of Point eqpts. which includes all SandT fittings of electrical and mechanical, facing point lock/ hand plunger lock/ lock bar / holding bar/ EPD/
and stack in the store of SSE/Sig/C/TKJ or DY.CMM/SSB store depot at SSB as per site supervisoror any other store of northern railway Note :- Before dismantling joint survey is to be done with the site engr. and report to be submitted to the site engr.(1 Job= 1 Point). (Inspection : Site Engineer)
Description:- Dismantling and releasing of location boxes which includes all SandT fittings of electrical and mechanical, releasing of termination boards, relays, terminals, batteriies, track feed
matterial to be transported and stack in the store of SSE/Sig/C/TKJ or DY.CMM/SSB store depot at SSB as per site supervisoror any other store of northern railway. Note :- Before dismantling joint survey is to be done with the site engr. and report to be submitted to the site engr. (1 Job= 1 Location Box). (Inspection : Site Engineer)
DYCSTE-C-TKJ-S AND T/NORTHERN RLY Description:- Dismantling and releasing of S and T gears in ASM room,Battery room, relay room,
terminal board, SM Slide frame, panel batteries, battery chargers, DG sets,angle iron, etc. All dismantelled matterial to be transported and stack in the store of SSE/Sig/C/TKJ or DY.CMM/SSB store depot at SSB/ as per site supervisoror any other store of northern railway. Note :- Before dismantling joint survey is to be done with the site engr. and report to be submitted to the site engr.(One job= One Room). (Inspection : Site Engineer)
Description:- Dismantling and releasing of lever frame which includes all SandT fittings of electrical and mechanical on top floor and basement of the cabin and stations. All dismantelled matterial to be
supervisoror any other store of northern railway. Note :- Before dismantling joint survey is to be done with the site engr. and report to be submitted to the site engr.1 Job= 1 Lever). (Inspection : Site Engineer)
Description:- Dismantling and releasing of rod run from lead off and final to different function I.e. points, locks, lock bars/holding bars/clearance bar which includes cranks, compensators, trestles 4/2
transported and stack in theSSE/SE/Sig/C/TKJ or DY.CMM/SSB store depot at SSB/ as per site supervisoror any other store of northern railway. Note :- Before dismantling joint survey is to be done with the site engr. and report to be submitted to the site engr. (Inspection : Site Engineer)
Description:- Shifting of Apparatus case Single and it includes the Excavation of pit in and around the existing location boxes very carefully without damaging the working cables and shifting and turning the location boxes to clear of the infringment as instructed by the railway repsentative at
access for shifting/ turning the location boxes. Necessary masonary work and earth work in and around the location boxes to the required level shall be done as instructed by the Railway representative at site, if the existing earth connection to the location boxes are disturbed the earth wires shall be the properly reconnected. (All materials required for the work shall be supplied by the contractor). (Inspection : Site Engineer)
Description:- Shifting of Apparatus case half and it includes the Excavation of pit in and around the existing location boxes very carefully without damaging the working cables and shifting and turning the location boxes to clear of the infringment as instructed by the railway repsentative at site. The
for shifting/ turning the location boxes. Necessary masonary work and earth work in and around the location boxes to the required level shall be done as instructed by the Railway representative at site, if the existing earth connection to the location boxes are disturbed the earth wires shall be the properly reconnected. (All materials required for the work shall be supplied by the contractor). (Inspection : Site Engineer)
Description:- Earth work for excavation and refilling around location boxes, signals etc. where
breaking of clods, levelling and dressing. The earth work around the location/junction boxes/signalls shall be up to the plaster level and for width sufficient for the maintainer to attend the box both from front and back side. (Inspection : Site Engineer)
Description:- General concrete work in cement, coarse sand and aggregate ratio 1:3:6, work
be done with cement sand ratio of 1:4 . Volume of foundation also includes volume of C.I. base, anchor bolts etc. Coarse sand, aggregate 25mm and cement to be supplied by contractor. (Inspection : Site Engineer)
(ordinary) mixture of 1:4 ratio. All material is to be supplied by the contractor. (Inspection : Site Engineer)
Description:- "Cleaning , Scrapping , Painting and lettering of all newly installed and existing gears such as signals, point equipment, track circuit equipment with T.C. no on rail app. Cases JB. TL JBs point rodding cranks, compensators etc. including gate equipment if existing in station section as per the provision of IRSEM. All paints (ISI marked) shall be approved by Railway Engr. and painting 95 material to be supplied by the contractor. This item also includes writing and painting requirement of all indoor and outdoor gears along with making of all circuit nos. near terminal and terminal boards/track in app. Cases, junction boxes, relay room, SMs room, writing of relay nomenclature fuse nos. and equipment nomenclature as the approved plans and as per provision of IRSEM. (1 Job=1 Station).(Inspection : Site Engineer)" DYCSTE-C-TKJ-S AND T/NORTHERN RLY
Description:- Relay,AC immune, plug in type, style QNA1,DC neutral line relay,24 V DC 8F/8B
confirming to BRS:931A, IRS: S@45<47N44@ IRS: S@45"47@68 & IRS: S-23/88 as applicable. (Inspection: RDSO).
Description:- Relay,Non AC immune, plug in type, style QN1,DC neutral line relay,24 V DC 12F/4B
confirming to BRS:931A, IRS: S@45<47N44@ IRS: S@45"47@68 & IRS: S-23/88 as applicable. (Inspection: RDSO).
Inspection Consignee
latest. Inspection Consignee
insulation thickness of 1.20 mm nominal conductor resistance 0.780 ohms/km and other parameters as per IRS: 76/89 with latest amdt. Inspection Consignee
materials) as per IRS spec. No. IRS-76/89 with amendment no.3 or latest. (From RDSO Approved Source only) (Inspection : Consignee)"
Description:- Engaging mechanical excavators like JCB or other machineries for regarding and
all lead and lifts etc., complete and as per the instruction of railway representative at site.( Inspection: Site Engineer)
Description:- Supply, Fixing and wiring of magneto telephones with all accessories including
and interlocked L-xing gates as per instructions of the site Engr. All fixing materials including Standard battery box and 3 nos. Of RR cells to be supplied by the contractor. Inspection : Consignee
Description:- Supply and Installation of 10 pair DP box made of cast Aluminium with in built locking system and water proof should have double outlet with leadig in brass nozzle.The main tag block plate is mounted on the inner aluminium chamber with brass terminal studded in back lite sheet. DP
This includes fixing of the same on 1" thick board of size as pesr directions of site engineer with ground nuts and bolts of suitable size and pipe fixed with clamps on pole /wall .All materials required for fixing and termination including salwood/hylum board and the hardware required for fixing will be supplied by contractor. (Inspection : Consignee for supply portion and Installation by Site Engineer)
Description:- Supply and Installation of 20 pair DP box made of cast Aluminium with in built locking system and water proof should have double outlet with leadig in brass nozzle.The main tag block plate is mounted on the inner aluminium chamber with brass terminal studded in back lite sheet. DP
This includes fixing of the same on 1" thick board of size as pesr directions of site engineer with ground nuts and bolts of suitable size and pipe fixed with clamps on pole /wall. All materials required for fixing and termination including salwood/hylum board and the hardware required for fixing will be supplied by contractor. (Inspection : Consignee for supply portion and Installation by Site Engineer)
Description:- Supply and Installation of Annunciator (Multiway Telephone Exchange) 10 lines as per
wire etc will lbe supplied by contractor.(Inspection : Consignee for supply portion and Installation by Site Engineer)
107 Description:- Supply of PVC channel 1"with fixing accessories. (Inspection : Consignee )
108 Description:- Supply of PVC channel 2"with fixing accessories.(Inspection : Consignee)
109 DYCSTE-C-TKJ-S AND T/NORTHERN RLY 109 Description:- Supply of PVC conduit pipe 1" dia with fixing accessories. (Inspection : Consignee)
indoor cable laying. All fixing material will be supplied by the contractor. (Inspection : Site Engineer)
Description:- Supply and Installation of Thermo shrink jointing kit for 6-Quad/4-Quad cable for
per approved cable route plan at various locations. Jointing kits to be supplied as per RDSO specification IRS:TC 77-2012 (Rev.-3) or latest amendments. (Inspection : Consignee for supply portion and Installation by Site Engineer)
Description:- Supply and Installation of Thermoshrink jointing kit for 6-Quad cable and PIJF cable
Engineer as per IRS: TC-77/2012 (Rev.3) with amendment 1 and 2 or latest. This includes all materials required for joints.(Inspection : Consignee for supply portion and Installation by Site Engineer)
Description:- Supply and Laying of HDPE duct in the trenches, including in HDD/Manual Boring and supply pulling of Nylon rope through is at different places as per direction of Engineer incharge/ site
G/CDS-08/02 Nov /2004 with latest amendment with end cap to be provided along with the drum at both ends . (RDSO specs No. RDSO/SPN/TC/45/2013 revi 2.0) (Inspection : Consignee for supply portion and Installation by Site Engineer)
No. G/CDS-08/02 Nov /2004 with latest amendment. (Inspection : Consignee)
per TEC Gr No. G/CDS-08/02 Nov /2004 with latest amendment. (Inspection : Consignee)
inner dia 33mm as per TEC Gr No. G/CDS-08/02 Nov /2004 with latest amendment (Inspection. Consignee)
system. (Inspection : Site Engineer)
Description:- Supply and installation of optical fibre cable joint enclosure as per TEC spec no.
testing) . This includes provision of joint pit (RCC/Prefabricated) as detailed in the technical specifications and as advised by Engineer at site. (Inspection : Consignee for supply portion and Installation by Site Engineer)
120 Description:- Typing and Printing One master Copy SET in Hindi. Inspection by SSE/C/D&D.
121 Description:- Photocopies of Hindi Master Copy Set Inspection by SSE/C/D&D.
cover. Inspection by SSE/C/D&D.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .