Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.8 LAccepted-AOC S NO 279 1 1A PLOT NO 113 KUTWAL COLONY SASTHE WASTI LOHEGAON PUNE 411 047 | PUNE | MAHARASHTRA | 411047 | L1 | Accepted-AOC Acceptance | |
| 2 | L2₹22.6 L+₹43,762.43 (1.97%)Rejected-Finance | L2 | Rejected-Finance Rejected being other than lowest | |
| 3 | L3₹22.7 L+₹53,078.53 (2.39%)Rejected-Finance | L3 | Rejected-Finance Rejected being other than lowest | |
| 4 | L4₹30.0 L+₹7.8 L (35.0%)Rejected-Finance FLAT NO 03 PANCHAVATI BUILDING ADARSH NAGAR CHICALIM GOA 403711 | SOUTH GOA | GOA | 403711 | L4 | Rejected-Finance Rejected being other than lowest |
Tender Value
₹24.5 L
EMD Value
₹49,000
Closing Date
21 Nov 2019, 6:00 pmClosed
GE (I) (P) Ratnagiri
Garrison Engineer (I) (P) Ratnagiri SLUY Shed Plot, W19-23, MIDC Mirjole, Ratnagiri - 415 639
REPAIR/MAINT OF EXTERNAL ELECTRIC SUPPLY, TRANSFORMER AND DG SETS AT CGRA AREA AND TRV CHICOLNA UNDER AGE/BR, GOA UNDER GE (I) (P) RATNAGIRI
2019_MES_290562_1
8106/E8
Open Tender
Civil Works
Item Rate
Goa
Please refer tender documents
6 documents required · 6 mandatory
₹500
GE (I) (P) Ratnagiri
₹49,000
21 Feb 2020
17 Oct 2019
25 Nov 2019
17 Oct 2019
21 Nov 2019
7 Nov 2019
Amount
Excavation in trenches n.exc 1.5 m deep and n.exc 1.5 m wide and getting out in hard dense soil for taking up/relaying LT UG cable/ pipe all as specified and directed.
All as per Item No1.00 above but in soft disintegrated rock/ laterite rock all as directed.
Returning filling in excavated earth work including spreading, levelling, watering and well ramming in layers n.exc 25cm thick in any strata.
Removing excavated soil to a distance n.exc 50m, depositing where directed at a level n.exc 1.5m above the starting point
Supply/ Lay dry river sand/ M sand in trenches for cable protection all as specified and directed. Note : Punned thickness only will be measured & Paid.
Supply and lay bricks common burnt clay building bricks: sub class 'B' designation 75 for cable cover all as directed.
M & L for PCC (1:4:8) type D-2 (using 40 mm aggregate) as in foundation for pole etc.complete all as specified and as directed.
M & L for PCC (1:3:6) type C-1 using 20 mm graded stone aggregate as in coping of pole etc. including form work & finishing the surfaces even & smooth with out using extra cement complete all as specified and as directed.
M & L for PCC (1:2:4) type B-2 using 40 mm graded stone aggregate as in foundation for pole etc.complete all as specified and as directed.
M & L for painting of steel tubular electric poles 9.0 mtr long with with two coats of aluminium paint over a coat of red oxide primer after preparation of surfaces approved colour and quality including marking and painting with grey and blue colours strips with synthetic enamelled paint on intervals of 150 mm apart upto a height of 1.5 mtr from the coping level and marking of Pole Number with letter like " MES LT No " all as directed by Eng-in-Charge.
Taking out LT UG cable of any type and size from trenches/ walls etc.
M & L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of cross sectional area 185 Sqmm 3.5 core complete all as specified and directed.
M & L XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of cross sectional area 120 Sqmm 3.5 core complete all as specified and directed.
M & L XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of cross sectional area 95 Sqmm 3.5 core complete all as specified and directed.
M & L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of cross sectional area 70 Sqmm 3.5 core complete all as specified and directed.
M & L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of cross sectional area 50 Sqmm 3.5 core complete all as specified and directed.
M & L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of cross sectional area 35 Sqmm 3.5 core complete all as specified and directed.
M & L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of cross sectional area 16 Sqmm 2 core complete all as specified and directed.
M & L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of cross sectional area 10 Sqmm 2 corecomplete all as specified and directed.
Taking out old rusted / unserviceable steel tubular poles of 9 M long embedded in concrete into bottom of foundation with necessary excavation complete all as specified and directed.
Taking down street light fitting from pole for repairing / replacement / cleaning of any Wattage, including removing dead insect, dust and refixing again to same location. Note:- Replacement of accessories like Ballast, ignitor, lamp will be measured & paid seperately.
M & L for Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-22 (9 metres long) all as directed.
S & F in repair PVC FRP junction box with 01 No MCB SP of 6 Amp fixed on existing pole with clamp, nut & bolt connections including removing dismantling of unserviceable pole box and MCB complete all as specified and directed.
S & F FRLS PVC insulated copper conductor 2x 2.5 sqmm+1x1.5 sqmm earth wire in PVC conduit from fitting through the bracket to DB box all as specified and directed. Note: 2 run of 2.5sqmm, 1 run of 1.5 sqmm and 20mm PVC conduit will be measured as one length.
S & F in repair GI pipe medium grade 50 mm dia, for cable protection, road/drain crossing etc complete.
M&L preparation of old painted surface including cleaning the surface of the RCC pole (HT) above the ground level incl coping area with 2 coats of cement base paint over a coat of primer after preparation of surface including 12 cm width black paint around the pole, numbers/letters in white columns all as directed.
M&L preparation of old painted surface including cleaning the surface of the RCC street light poles above the ground level incl coping area and applying 2 coats of cement basepaint over a coat of cement primer after preparation of surface including 12 cm width black paint around the pole, numbers/letters in white columns all as directed.
Supply & lay GI tubing light grade protection of cable at road crossing /hard standing/pole protection fixed with clamps as per site requirement etc of size 40 mm dia bore complete all as specified and directed .
M&L for taking down old worn out/corroded body of LT panel board including rusted angle iron frame on which mounted and dismantling of Serviceable MCB, timer switch, contactor without damaging for refixing in new LT panel board body for street light complete all as specified.
carryingout maintenance of 11KV/440V transformer including the following works for 500 KVA capacity as follows : (a) Dismantling the transformer, drain out transformer oil, cleaning inside, scraping complete all around parts of the transformer. (b) Re-assembling all dismantled parts including provision of new gasket,nut,bolts,refilling with transformer oil including elecric connection testing and commissioning complete. NOTE :- i) supply of new oil will be measured separately. ii) All petty parts including nut, bolts, gasket and minor weldings /patch work are deemed to be included in the rate quoted iii) The rate for transport to the maintenance workshop and lifting of transformer by crane will be measured seperately.
All as per item No 31 above but for 250 KVA.
All as per item No 31 above but for 100 KVA.
Disconnecting HT 11 KV incoming side and LT 430 V outgoing side connections from defective / repairable 11KV/ 430 V Transformer of capacity up to 500 KVA including earthing strips, loading and unloading to Authorized maintenance workshop for repair in a suitable load carrier vehicle with using required capacity crane / Manual tripode and vehicle from Outdoor / indoor 11KV Substation yard CGRA and TRV under AGE B/R Goa to Authorized maintenance workshop and same return back at its existing installation place including testing, commissioning on site/area complete all as specified and directed.
S&F in repairs HT bushing insulator, Brass metal studs nut & washers suitable for HT bush side of transformer up to 100 KVA
All as per item No 35 above but for 250 KVA capacity of transformer.
All as per item No 35 above but 500 KVA capacity of transformer.
S & F in repairs LT bushing insulator, Brass metal studs nut & washers suitable for LT 415 Volt bush side of transformer up to 100 KVA capacity of transformer.
All as per item No 38 above for 250 KVA capacity of transformer.
All as per item No 38 above but 500 KVA capacity of transformer.
Supply and fill new EHV grade insulating transformer oil complete with minimum BDV 60 KV and by replacing existing complete transformer oil all as specified and as directed by Engr-in-charge. Make -Power Oil or approved make.
Supply and fill in repairs existing breather silca jel of superior quality for transformer breather complete all as specified and directed by Engr-in-charge.
Supply and fix in repairs breather unit of transperant PVC material including its replacement for transformer of capacity up to 250 KVA.
All as per item No 43 above but 500 KVA capacity of transformer.
M&L in repair to transformer radiator fins, drain out the transformer oil including refilling the same after repairs cut and remove unserviceable transformer fins and fix / weld new radiator fin assembly complete suitable for transformer upto 100 KVA Capacity all as specified. NOTE : Cost of lifting the transformer by crane, transportation to workshop, testing, re-installation and commission are deemed to be included in the rate quoted.
All as per item No 45 above but suitable for Transformer 250 KVA to 500 KVA Capacity
M & L for painting of transformer outside of body with all accessories completely, including cleaning the body scrubbing thoroughly and applying two coat of synthetic enamel existing shade of paint over a coat of red oxide primer to transformer of capacity up to 500 KVA and writing SM/MES No. all as specified and directed by engr-in-charge.
S & F in repair temperature gauge dial thermometer with a bimetal sensing system suitable size for transformer of any capacity. Make - Precimeasure controls or equivalent make
Supply & fixing oil level indicator glass of existing size of the transformer of any capacity including replacement of allied gaskets complete and draining out transformer oil from conservator complete all as specified and directed by Engr-in-charge.
M & L for fixing of lugs on LT cable to connecting on LT side bushing by removing old lugs fixed on LT bushing complete for 95 to 400 Sqmm 3.5 core cable all as specified.
M & L for fault finding for Transformer 11KV/433V and Capacity upto 500KVA incl dismantling LT and HT cable connection, checking the transformer winding for open circuit, short circuit or internal short circuit LT/HT bushing failure etc all as directed and specified by Engr-in-charge. Note:- i) Inspection and fault location shall be carried through authorised agencies. Ii) Equipment required for fault finding shall be provided by the contractor.
S&F in repair disc type porcelain vitreous, brown or white insulator to suit 11 KV HT working Pressure of size 145 mm height, 255 mm dia , including. one galvanised mild steel spindle, two galvanised iron washer and one GI nut complete including dismantling existing old insulator from position.
S&F in repair for Pin type porcelain vitreous,brown of white insulator to suit 11 KV HT of working pressure of size 150mm height, 150mm dia, including one galvanised mild steel spindle, two galvanished iron washer and one GI nut complete including dismantling existing old insulator from position.
S&F in repair for Post insulator suitable for 11 KV HT working pressure including all connected accessories including dismantling existing old insulator from position.
M&L for Replacement of ACSR type jumpers(appx 1.5 RM in length) of suitable dia incl aluminium lugs of suitable size for HT structures and yards including PVC insulation pipe and cleaning of carbon deposited on joints,applying jelly to each contact points and GOD male & female contacts and dismantling old jumpers complete all as directed.
Taking down 11 KV HT Drop out fuse assembly with DO Fuse unit all as directed.
Material & Labour for HT Drop out fuse assembly of 11 KV Current Rating of 200 Amps with 2 post insulator per phase,double stack channel type incl steel base mounting frame,MS Nuts and bolts complete all as specified and directed. Make :- Jaipuria/ Pactil /GEC
Taking down Triple pole Air break switch mechanism complete all as specified and directed.
Material & Labour for outdoor type Gang operated Air break switch triple pole, mechanically operated, mounted on insulator and steel frame,with operting mechanism worked from ground level with GI pipe medium grade, for current rating upto 200 Amps suitable for vertical mounting fixed type complte with 09 Nos HT insulators suitable for HT 11 KV complete all as specified and directed. Make :- Jaipuria/ Pactil /GEC
Material & Labour for Lightning Arrestor (LA) zinc oxide type complete with all fittings transmission class, discharge capacity 10 KA, suitable for 12 KV complete all as specified and directed. Make :- Jaipuria/ Jaisree /Southern Insulators
Supply only in repair HT Fuse element of following rating:- (a) HT 11KV, 10 Amp to 30 Amp rating
(b) HT 11KV, 30 Amp to 60 Amp rating
Supply only HT type Insulating Tape non heat shrinkable type of 38 mm width and 10 Mtr length.
Painting the panel board, feeder piller etc with two coats of synthetic enamel paint over the existing painted surfaces after preparing the old painted surfaces and apply putty and a coat of red oxide primer all as specified and as directed.
S & F for replacement of straight through heat shrinkable type including joint kits for making joints suitable for LT aluminium conductor cables for following sizes :-(a) 4/3.5 Core 16 to 35 Sqmm.
(b) 3.5 Core 50 to 70 Sqmm.
(c) 3.5 Core 120 to 150 Sqmm.
Dismantling of MS cross arms bracing support clamps nuts bolts and washers etc and M/L for cross arms channel, bracing, support, clamps etc fabricated structured steel, sections, including nuts, bolts, washers etc and cutting to required length beat to any shape drilling holes, fixed on poles all as specified and directed incl painting with 2 coats of aluminum paint over a coat of red oxide primer after preparation of surfaces.
S & F in replacement end termination joint kit outdoor heat shrinkable type for 50 to 90 Sqmm 3 core XLPE cable 11000 Volts
S & F in replacement end termination joint kit outdoor heat shrinkable type for 120 to 185 Sqmm 3 core XLPE cable 11000 Volts
M&L for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x15cm size
M & L for Earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick, buried directly in ground vertically earth pit not less than 2.25m deep below the ground level with top to edge of the plate n. less than 1.5m below ground level connected to galvanized earth wire 4 mm dia by means of blots, nuts, check nut and washer of galvanized steel, including necessary earth work and excavation in any strata and PCC 1:3:6 type C2 chamber and RCC cover and light grade GI pipe 15mm dia pipe of required length for protection of GI wire and water funnel and wire mesh with GI pipe medium grade 20mm dia etc complete all as per electrical plate No 3 of SSR part - I and all directed including connections and testing on completion all as specified.
M & L for Earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick, buried directly in ground vertically earth pit not less than 2.25 mtr deep below the ground level with top to edge of the plate n. less than 1.5 mtr below ground level connected to galvanized iron strip 25 x 4mm as earthing lead by means of blots, nuts, check nut and washer of galvanized steel, including necessary earth work and excavation in any strata and PCC 1:3:6 type C2 chamber and RCC cover and light grade GI pipe 15mm dia pipe of required length for protection of GI wire and water funnel and wire mesh with GI pipe medium grade 20mm dia etc complete all as per electrical plate No 3 of SSR part - I and all directed including connections and testing on completion all as specified.
S & F in repairs for epoxy insulator suitable for 11 KV reel type inside LT feeder pillar box outdoor type including replacement of new nut, bolt and washer on bus bar and base complete all as specified and directed.
Supply only electrical rubber Hand gloves suitable on working pressure of 11 KV Make : Jaipuria/Pactil or equivalent approved make.
S & F insulating rubber mat ISI marked of size 1 m x 2 m x19mm suitable for 11 KV at CGRA & TRV Area.
S & F in repairs AAC for binding purpose of not less than 0.9mm dia for tightening the conductors on poles complete all as direcetd.
S & F in repairs for epoxy insulator suitable for an 415/433 Volts reel type inside LT sub main feeder pillar box outdoor type including replacement of new nut, bolt and washer on bus bar and base complete all as specified and directed.
S & F in repairs for loop insulator Vitreous Porcelian white or brown of size 90 X 140 mm clearance hole 25.5 mm complete all as specified and directed.
M&L in repairs for Cable route markers made of cast iron 10mm thick 4" dia with HT/LT Cable MARK and indication of direction and in casting welded to angle iron 40x40x6mm, 450mm long embedded in PCC block 1:2:4 B1 (20mm aggregate) of size 150x150x300mm deep complete all as directed.
Supply only Anodised aluminium frame ladder extension type, close height 18 ft and extended height 32 feet heavy duty all as specified and directed. Make - Bathla Model No WE 1132 or equivalent
supply and install First aid box of standard size quipped with all medicine and equipments required for first aid complete all as specified and directed
Service Charges for Carrying out 'C' Check maintenance for DG sets from authorised rep or service engineer from the OEM of DG set of Kirloskar Cummins make of 35 KVA capacity at CGRA Pump House of injector & valve tappet setting, checking of vibration damper, checking turbocharger, oil leakage, tightening mounting screws & nuts, replacement of filters & oil, checking inlet & Exhaust manifold cap, screws, checking of fan hub & water pump, removing the existing unserviceable engine oil, clean the oil sump and refilling with required quantity of new oil & coolant top up, charging of battery, filling of distilled water, cleaning of radiator fins by using blower / inside tank with solution (caustic soda with water) to the entire satisfaction of Engr-in-charge, trial & testing etc. Note : (1) The 'C' Check Maint spares, engine oil, Coolant, caustic soda solution (restore plus) will be measured and paid separately under relevent item of this schedule. 2. Any other check as per menufacturer's instructions / Engr In charge direction shall be carried out by the contractor and the same may be included in the quoted rate.
Supply only Lubrication oil filter, cartridge
Supply only Fuel Filter assy Diesel Primary
Supply only Fuel Filter assy Diesel Secondary
Supply only Air Cleaner primary element
Supply only Air Cleaner safety element
Supply only Tappet cover Gasket.
Service Charges for Carrying out 'C' Check maintenance for DG sets from authorised rep or service engineer from the OEM of DG set of Kirloskar Cummins make of 50 KVA capacity at TRV Pump House of injector & valve tappet setting, checking of vibration damper, checking turbocharger, oil leakage, tightening mounting screws & nuts, replacement of filters & oil, checking inlet & Exhaust manifold cap, screws, checking of fan hub & water pump, removing the existing unserviceable engine oil, clean the oil sump and refilling with required quantity of new oil & coolant top up, charging of battery, filling of distilled water, cleaning of radiator fins by using blower / inside tank with solution (caustic soda with water) to the entire satisfaction of Engr-in-charge, trial & testing etc. Note : (1) The 'C' Check Maint spares, engine oil, Coolant, caustic soda solution (restore plus) will be measured and paid separately under relevent item of this schedule. 2. Any other check as per menufacturer's instructions / Engr In charge directeion shall be carried out by the contractor and the same may be included in the quoted rate.and directed by Engineer-in-charge.
Supply only Lubrication oil filter, cartridge
Supply only Fuel Filter assy Diesel Primary
Supply only Fuel Filter assy Diesel Secondary
Supply only Air Cleaner primary element
Supply only Air Cleaner safety element
Supply only Tappet cover Gasket.
Supply & filling Engine Oil / K- Oil
S & F in repairs Radiator assembly with tank of complete set made up of copper fins and tube suitable for 50 KVA DG set of any make as existing all as directed.
Service Charges for Carrying out the 'B' Check maint from authorised rep or service engineer from the manufacturer of DG set of Engine Greaves/Kirloskar/Cummins of 35 KVA capacity Engine at CGRA Pump House , checking of vibration damper, checking turbocharger, oil leakage, tightening mounting screws & nuts, replacment of filters, checking inlet & Exhaust manifold capscrews, checking of fan hub & water pump, toping up level the existing engine oil, coolant top up and in replacement, supplying & fixing of following spares :- Note :- 'B' check shall be carried out on running of 500 hrs or three months which ever is earlier. (a) Kit, fuel filter and ring - 2 Kit (b) Element for Lubrication oil filter - 2 Nos. (c) Kit, Element of super bypass filter - 01 Kit (d) Seal, O Ring - 02 Nos
Service Charges for Carrying out the 'B' Check maint from authorised rep or service engineer from the manufacturer of DG set of Engine Greaves/Kirloskar/Cummins of 50 KVA capacity Engine at TRV Pump House ,checking of vibration damper, checking turbocharger, oil leakage, tightening mounting screws & nuts, replacment of filters, checking inlet & Exhaust manifold capscrews, checking of fan hub & water pump, toping up level the existing engine oil, coolant top up and in replacement, supplying & fixing of following spares :- Note :- 'B' check shall be carried out on running of 500 hrs or three months which ever is earlier. (a) Kit, fuel filter and ring - 2 Kit (b) Element for Lubrication oil filter - 2 Nos. (c) Kit, Element of super bypass filter - 01 Kit (d) Seal, O Ring - 02 Nos
Supply & filling Coolant concentrate Superkool xtra as required in the DG oil sump all as directed. Make : VALVOLINE/SERVO/HINDUSTAN
Supply & filling Engine Oil Premium Blue 15 W 40 grade API CI 4 PLUS as required in the DG oil sump all as directed. Make : VALVOLINE/SERVO.
Supply & chelating cleaner Restore Plus solution Part No. AX1001098 Make : Cummins for engines cooling system all as directed.
Dismantling the defective alternator of any capacity from the existing foundation and from Engine after removing all electrical connections, transporting to approved / authorised / directed workshop, opening and taking out burnt winding, cleaning the stator assy rewinding with super enameled copper wire as per existing gauge as per original manufacturer and applying insulating varnishing of ‘F’ class, baking in oven re-assembling the alternator, transporting back to site re-installing the same position, carrying out alignment of complete DG set connecting up all electrical connections testing and commissioning complete. Note : - (a) Rate quoted shall be deemed to be inclusive of making good the disturbed surfaces. (b) The DG set shall be tested on load as per rated capacity for the satisfaction of Engineer- in- Charge to achieve designed parameters.
S & F in repair door hinges for canopy of any capacity of DG set door including nut, bolt, drilling of hole, welding as per directed.
Dismantling the old and unserviceable DG Set rubber hose pipe up to 2'' to 4" dia and replacing the same with of existing size and equal length for any capacity DG Set including both side hose clamp, with nut, bolt and washers as required , etc as directed by the Engineer in Charge .
Supply and fixing in repair battery terminals brass suitable for 95 AH to 180 AH battery .
Supply and fixing in repair rectifiers diodes for 30/50 KVA DG sets Make : Kirloskar/ Cummins/stanford .
Dismantling the radiator assy from the DG set of 35 to 50 KVA capacity carefully for necessary repair , soldering the cooling tube if found weak /leakage , cleaning properly , replacement of nuts , bolts , rubber mounting bushes etc and refixing at the same site including testing on completion.
S & F battery charging unit industrial type floor mounted heavy duty, with steel enclosure, vlot meter, Ammeter, Toggle switch, chrger ON-OFF switches suitable for charging 2 Nos of lead acid battery 12- 24 V DC out put type and suitable for 230 volts incoming AC supply all as directed.
Dismantling the unserviceable Dynamo / Alternators 12/24 volts and rewinding with ‘F’ class copper wire of 22 /existing gauge incl dismantling the old coil, cleaning thoroughly and winding with super enamelled copper cord of existing size and gauge, varnishing, drying etc and re fixing with dynamo/alternator properly including testing on completion.
Dismantling the defective Dynamo /Alternators 12/24 volts and necessary repair with replacement of defective spares such as, carbon brushes, carbon spring, bearing, bushes, defective wiring, and soldering after re-fixing at site.
Dismantling the defective self starter assy of 12/24 volts and necessary repair with replacement of defective spares such as, carbon brushes, carbon spring, bearing, bushes, defective wiring and soldering after repair, re-assembling and refixing at site complete as directed including testing on completion.
M&L for providing new AVR unit suitable for 15 KVA to 50 KVA DG Set size in repairs ie taking down of old AVR unit, complete all as specified and as directed by Engineer -in-charge. Make: Kirloskar/cummins/stanford
Dismantling the old and unserviceable DG Set Diesel/oil pressure pipe of existing size and replacing the same with of existing size and equal length of 15 KVA to 50 KVA DG Set including both side hose clamp , etc as directed by the Engineer in Charge .
Dismantling the defective exciter of DG set of any capacity from the existing foundation and engine after removing all electrical connections, transporting to workshop rewinding the burn out coil complete with super enamelled copper wire rewinding, applying insulating varnish of 'F' class baking in oven reassembling the alternator, transporting back to site, re-installing the same carrying out alignment of complete DG Set connecting up all electrical connections, testing & commissioning complete.
Dismantling the defective alternator assembly of capacity 35 to 50 KVA DG set from the engine including opening of canopy, transporting to the reputed or as directed workshop, opening the alternator, taking out burnt winding from the stator carefully with out damaging core etc, rewinding with super enamelled copper conductor with existing gauge and size including at the same site connecting to engine assy and testing after installation complete all as directed by Engineer in charge.
Supply and fixing digital in repair type volt meter square type 96x96 mm up to 3 Phase AC 50 HZ, 500 volts of and connecting complete make : Meco/AE or equivalent all as directed.
Supply and fixing copper cable multi stranded suitable for 12/24 volts battery replacing the same with of existing size and equal length complete fixing with brass clamp at both ends including taking down of old one from the existing battery.
supply and fixing of lamp indicator assy LED lamp type 230 volts AC .
S &F in repair asbestos rope 12 mm dia of superior quality for wrapping with the exhaust pipe of the DG set complete as directed.
S&F in replacement fan belt suitable for 15 to 50 KVA DG Set as per existing model and size including dismantling the old one.
Scraping the old paint from the DG set of 50 KVA capacity, applying one coat of synthetic enamel paint of approved make, writing of SM/MES No at easily visible manner complete as directed.
S & F in repairs Turbo kit for 35 to 500 KVA DG Set for Cummins / Kirloskar / Greaves DG Set.
S & F in repairs solenoid switch complete set as per existing size and make of DG Set 15 to 50KVA DG Set all as directed. Make Kirloskar.
M & F for opening the alternator assy of any capacity from the existing foundation and Engine after removing all electrical connections, taking out the Field winding, transporting to approved / authorised / directed workshop, opening and taking out burnt winding, cleaning the Field coil stator assy rewinding with super enamelled copper wire as per existing gauge as per original manufacturer and applying insulating varnishing of ‘F’ class, baking in oven re-assembling the alternator, transporting back to site re-installing the same position, carrying out alignment of complete DG set connecting up all electrical connections testing and commissioning complete. Note : - (a) Rate quoted shall be deemed to be inclusive of making good the disturbed surfaces. (b) The DG set shall be tested on load as per rated capacity for the satisfaction of Engineer- in- Charge to achieve designed parameters.
S & F in repairs magnetic speed censor assy suitable for Kirloskar make DG sets all as directed. (Make : Kirloskar/Cummins)
S & F in repairs Electronic Speed control unit suitable for 15 to 50 KVA Capacity Kirloskar make DG sets all as directed. (Make : Kirloskar/cummins )
Dismantling and taking out the defected Electromagnetic speed Governor unit with fuel injector pump assy from the DG set, transport to authorised work shop, cleaning the Fuel injector, Nozzle, calibration in test bench re-assembling into the DG set with necessary new gaskets/ nut, bolt and washer and testing complete all as directed. Note : The cost of spares like new injector / nozzle / gasket / seal / nut, bolt and washers are deemed to be included in the quoted rates.
Dismantling the defective Radiator assy form the DG set of 15 to 50 KVA capacity by disconnecting all incoming and out going cooling line, transporting to the work shop cutting and taking out the all fins with cooing line replace the same size with new copper cooling line with fins by bracing work complete incl leak arrest in radiator tank by welding and sealing and re-fix the same into the old position all as directed.
S & F in repairs Complete Wring harness system incl necessary elect connections for 15 to 50 KVA Capacity complete all as directed. Make Kirloskar/Cummins.
S & F in repairs self starter push button / or with Key arrangement for DG starting suitable for Kirloskar / Cummins DG sets all as directed.
S & F in repairs micro processor based DG control unit suitable for 15 to 50 KVA Capacity Kirloskar make DG sets incl neccessary connections and testing complete all as directed. (Make : Kirloskar/Cummins)
S & F of distilled water in the DG battery complete all as specified.
Supply and fix in repair flat 6 sqmm, 3 core PVC insulated and PVC Flat sheathed industrial cable for submersible pump motor, 1100 volts confiming to IS: 694
S & F in repairs Feed pump, hand operated for fuel pumping suitable for 35 to 50 KVA capacity DG sets
M & L for opening the cylinder head of the engine and oil sump carefully for replacement of head gasket including sump gasket complete refixing the head and sump to arrest oil leakage with engine complete with proper alignment and testing the engine for 1 hrs on load to achiveve designed parameters all as directed by Engineer-in-Charge of capacity 15 KVA to 35 KVA.
M & L for opening the cylinder head of the engine and oil sump carefully for replacement of head gasket including sump gasket complete refixing the head and sump to arrest oil leakage with engine complete with proper alignment and testing the engine for 1 hrs on load to achiveve designed parameters all as directed by Engineer-in-Charge of capacity 35 KVA to 50 KVA.
Charges for attending break down of DG set of 35 to 50 KVA capacity by only auth OEM rep / team for fault finding incl attending repairs as and when required such as No start condition of DG and repairing, starting the DG set till smooth running and setting up the alighnment / required paramenters of all major parts such as fan belt, AVR, RPM, sencors, actuators, Engine safety units, bty chargers, AMF relays, fuel / oli levels, speed governer, Micro processor based control panel, Injector pumps etc as required in ground / as ordered by EIC all as directed. (The payment for the above shall be made to Contractors after submitting the original invoice only)
SLB Enterprises
Shine Enterprises
M/s. P S REDDY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .