| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.3 LAccepted-AOC 03 RAJA GARDEN EXT KAPURTHALA ROAD JALANDHAR CITY | JALANDHAR | PUNJAB | 144001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹4.5 L+₹21,480.54 (5.05%)Rejected-AOC 99 SAINIK VIHAR JALANDHAR | JALANDHAR | PUNJAB | 144001 | L2 | Rejected-AOC L2 | |
| 3 | L3₹4.6 L+₹30,509.70 (7.18%)Rejected-AOC HOUSE NO 3 RAJA GARDEN EXT KAPURTHALA ROAD JALANDHAR | L3 | Rejected-AOC L3 |
Tender Value
₹5.1 L
EMD Value
₹10,200
Closing Date
2 Dec 2024, 12:00 pmClosed
O/O EXECUTIVE ENGINEER WSS DIV NO. 1 JALANDHAR
O/O EXECUTIVE ENGINEER WSS DIV NO. 1 JALANDHAR
DNIT for Estate Sewerage system of shifted buildings For Civil Surgeon office Jalandhar. Deposit Work
2024_WSS_130153_1
07-GOVTWOKS-2024
Open Tender
Civil Works
Item Rate
60 days
Jalandhar
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
₹10,200
31 Jan 2025
21 Nov 2024
2 Dec 2024
21 Nov 2024
2 Dec 2024
21 Nov 2024
Amount
Estate Sewerage System
Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm
100mm internal Diametre S.W.gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm
Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement,R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming toI.S.I complete as per standard design.
450mm x 600mm inside with 455mm x 610mm cover and frame light duty double seal
Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects.
200mm o/d pipe
160mm o/d pipe
Providing and filling sand grading as per specifications or fine grade around the various sizes of G.I. pipes in external work
Earth work in excavation for storage and sedimentation tanks, high level tanks, filter beds, clear water reservoirs, pump houses, sumps, screening chambers and other similar works having straight or open cuttings in foundations trenches etc. with 3D Excavator/ JCB including manually dressing of bed, trimming of sides and side slopes to full dimension and depth as shown on the drawings or as shall be required by Engineer- in-charge, including dressing of bottom and sides of trenches, stacking the excavated soil clear from the excavation and subsequent filling around plinth/structures including watering dressing and disposal of surplus soils as directed upto 15 metre complete in all respects.
For depths not exceeding 3.0 metre B.G.L. For all classes of soil except rocky
Dismantling Brick or flanged stone flooring without concrete base as per CSR item No 8.19 & Dry brick on edge on paving with the dismantled bricks including sand grouting and analysis A 13 complete in all respects.
Dismantling of cement concrete 80mm thick cement concrete 1:2:4 over 100mm thick C.C. 1:8:16 and making good the same to its original condition complete in all respects as per analysis A-25
Dismantling & Refixing of interlocking pavers and relaying in same condition complete in all aspects.
For 200 mm o/d PVC Pipe
Constructing brick masonry manhole in cement mortar 1:5 ( 1 cement : 5 coarse sand ) R.C.C. top slab 20cm thick using M-20 mix by using mixer and vibrator, TMT Fe500 @80.00 kg/per cum, foundation concrete 1:4:8 mix (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making 40mm thick benching in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, Orange coloured PVC steps including RCC cover with frame complete as per standard design complete in all respects.
Inside size 75x120 cm with depth 120 cm deep
Making connection of newly laid sewer in walls of existing manhole of fully charge sewer including cost of pluging sewer, desilting, removal of sullage water and making good of khudda
Sewer connections upto 300 mm id
Excavation in dumped stone or malba including stacking of unserviceable material separately and disposal of unserviceable material. Lead up to 50 m and lift up to 1.5 m, disposed material to be neatly dressed in all kinds of soils.
Disilting of manhole including all safety measures, cost of container T & P and disposal of silt upto 5km complete in all respects.
Depth upto 3 m.
RGM Contractorsco (BID ID -599912)
Suresh Kumar Jain (BID ID -599637)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .