Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.9 LAccepted-AOC | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹9.5 L+₹1.5 L (18.4%)Rejected-Finance VILL POST GOASI DIST PURNEA BIHAR 854301 | PURNEA | PURNEA | BIHAR | 854301 | L2 | Rejected-Finance Higher bid value |
Tender Value
₹9.8 L
EMD Value
₹19,600
Closing Date
19 Sept 2020, 6:00 pmClosed
AGE (I) (AF) PURNEA
AGE (I) (AF) PURNEA,CHUNAPUR,PURNEA
REPAIR/MAINTANANCE OF HANGER LIGHT,WATER SUPPLY STARTER PANNEL AND AIR CONDITIONERS,REFRIGERATION,WATER COOLERS AND ALLIED WORKS AT AFS PURNEA UNDER AGE (I) (AF) PURNEA
2020_MES_362267_3
C/8883/E8
Open Tender
Civil Works
Item Rate
240 days
AGE (I) (AF) PURNEA
AS PER NIT
7 documents required · 7 mandatory
₹500
AGE I AF PURNEA
₹19,600
Yes
8 Oct 2020
5 Sept 2020
21 Sept 2020
5 Sept 2020
19 Sept 2020
7 Sept 2020
Amount
Taking out old U/s panel board, removing all electrical connection carefully, and dismantling all connected accesories includin reconnection of cable in new panel board/ feeder pillar complete all as directed by Eng-in-charge
Supply and fix in replacement of Outdooor water proof LED glow sign board of Dimensin 8 X 3 Ft for out door installation having folwing specification (i) High quality star flex printing on Eco solvent printing ( Printing matter as given by Eng-in-charge) (ii)LED Tubes of Havells/Philips/Syska/crompton Waterproof- 06 No (iii) Electrical cables of Specific Size for connectioniv) Signage box with 1 ic square MS Pipe, With tin Material paintd with sian Paint / Berger Rust Proof
Supply and fixing in repairs , glands of size 10 mm all as specified and as directed by Eng-in-charge
Supply and fixing in repairs, 3/8'' white suction/discharge PVC tubing suitable for decrin Dosing pump of existing make all as directed
Supply and fix MS sheet cover for under ground sump manhole of size 600x600x6 mm with locking arrangement including MS bolt grouted in PCC and all fixing arrangement all as directed by Eng-in-charge
Material and labour for PCC type C2 1:3:6 (40 mm graded aggregate ) in foudations, filling and mass concrete all as specified and as directed by Eng-in-charge.
Taking down old U/S HPSV/HPMV/CFL/hanger light/Blastpen light/flood light/Aviation obstruction and High mast light type fitting after disconnexcting electric connection of any capacity from pole/building all as specified and directed by the Engr-in-charge.
S&F in Hanger/Blast pen LED light fitting circularHighbay with Tapered Fin designed along with IP 66 Protection 100watts including removing and safe refixing of hanger Net comlete all as specified (Make:- Crompton cat no-LHB11-110-CDL/60
S&F Beamer Non-Integral IP65 Flood Light fitting with LED flood light 200 watt with high luminous efficacy protected to IP 65 with front toughened glass complete e all as specified and directed by the Engr-in-charge.(Make:- Crompton cat no-LFLN-200-CDL/60
S&F in LED Aviation obstructiob light fitting Set Yellow or red colour 45Watt IP65 Protection comlete all as specified (Make:-bajaj,CG)
S&F in replacement of cable PVC insulated fixible type 2.5 sqmm 3 core copper conductor cable including laking out old and unserviceable cable from Hanger light/Blast pen light/Aviation light. Make: hevells/ finolex
S&F in replacement Double door sheet metal enclsoures TPN DB 4 way with 200 amps rated bus bar 415 volts. Make : Legrand
M&L in replacement Isolater/MCB TPN 415 volt,63 Amps,complete all as directed.Make-Legrand
M&L in replacement Isolater/MCB SPN 240 volt,40 Amps C curve,complete all as directed.Make-Legrand
S&F in replacement 16 sqmm 4 Core LT , XLPE insulated (heavy duty) PVC elecric cable with aluminium conductor , 1100 volte grade , cross-sectional area complete all as specified and directed.
M&L for servicing of 1.5/2.0TR capacity window/split type AC disconnect from electric connection and open suction & dicharge pipe from outer unit , such as removing/ scrach dust with iron brush,cleaning condessor unit,compressor,cooling coil/cleaning of fan blade/ cleaning of filter of inner unit etc,including(check thermostate,startingcapacitior,runningcapacitor) with water & air blower, at the site and reinstall at the same place including Re-filling of refregerent Gas as required complete all as specified and directed by Engr-in-charge.
Taking down/up defective AC (Window/Split Type) 1.5 TR Capacity, Transportation from MES Store Yard/Site to Workshop and Back including re-fixing /re-installing after taking out defective/burnt rotary type Compressor Sealed Unit and providing new Compressor of same Capacity from Authorised Dealer including Flushing of Condenser and Charging with required quantity of appropriate Refrigerant Gas including re-connection of Electric Connections, functioning AC complete in all respect and Testing, complete all as specified and as directed. MAKE : KIRLOSKAR/EMERSION/TECUMSEH
All as per Item No. 19 above but AC (Window/Split Type) 2.0 TR Capacity. Note: (Item No 2 above: Refreigerant Gas should be measured and paid under item here-in-after separately as required to fill as per requirement/manufacturer instruction excluding measurement of gas filled by OEM).
M&L Fan Motor of AC (Window/Split Type) 1.5 TR Capacity of approved Make and required Size to suit existing AC including Taking out the unservice-able Fan Motor from AC, complete all as specified and as directed. MAKE : AUE/FRAGMETER/GE
All as per Item No. 21 above but AC (Window/Split Type) 2.0 TR Capacity. MAKE : AUE/FRAGMETER/GE
M&L Air Circular Blower Fan Motor of AC (Split Type) 1.5 TR Capacity (as per Sample/Site Requirement) including Taking out unserviceable Air Circular Blower Fan Motor from AC, complete all as specified and as directed.MAKE : VOLTAS/LG/AMTEX/HITACHI
M&L Air Circular Blower Fan Motor of AC (Split Type) 2.0 TR Capacity (as per Sample/Site Requirement) including Taking out unserviceable Air Circular Blower Fan Motor from AC, complete all as specified and as directed.MAKE : VOLTAS/LG/AMTEX/HITACHI
M&L Remote Circuit Board including senser and display with Remote of AC (Split Type) 1.5 TR Capacity (as per Sample/ Site Requirement) including taking out unserviceable Remote Circuit Board including senser and display from AC, complete all as specified and as directed. MAKE : AMTREX/LG/VOLTAS/HITACHI
M&L Remote Circuit Board including senser and display with Remote of AC (Split Type) 2.0 TR Capacity (as per Sample/ Site Requirement) including taking out unserviceable Remote Circuit Board including senser and display from AC, complete all as specified and as directed. MAKE : AMTREX/LG/VOLTAS/HITACHI
M&L Capacitor Running 36 mfd – 45 mfd of AC (Window/Split Type) 1.5/2.0 TR Capacity including Taking out unserviceable Capacitor from AC, complete all as specified and as directed. MAKE : ELECTRO/UNIVERSAL/TIBCON
M&L Capacitor Starting 80 mfd – 120 mfd of AC (Window/Split Type) 1.5/2.0 TR Capacity including Taking out unserviceable Capacitor from AC, complete all as specified and as directed.
M&L Fan Motor Capacitor 4 mfd of AC (Window/ Split Type) 1.5/2.0 TR Capacity including Taking out unserviceable Fan Motor Capacitor from AC, complete all as specified and as directed. MAKE : ELECTRO/UNIVERSAL/TIBCON
M&L Fan Motor Capacitor 6 mfd of AC (Window/ Split Type) 1.5/2.0 TR Capacity including Taking out unserviceable Fan Motor Capacitor from AC, complete all as specified and as directed. MAKE : USHA/UNIVERSAL/TIBCON
M&L Starting Relay of AC (Window/Split Type) 1.5/2.0 TR Capacity including Taking out unserviceable Starting Relay from AC, complete all as specified and as directed.
M&L Thermostat Switch of AC (Window/Split Type) 1.5/2.0 TR Capacity including Taking out unserviceable Thermostat Switch from AC, complete all as specified and as directed.MAKE : INFOSS/ANNAPURNA/RENOLT
Supply and filling Gas Charging with R-22 /R134a/R404 Gas of AC (Window/Spilt Type) 1.5/2.0 TR Capacity with required quantity of Refrigerant in the Unit including Checking of Leakage in the System, Brazing the Leakage Parts of Oil Gas Tubing as required, complete all as specified and as directed.
Re-installation and re-commissioning Air Conditioner (1.5TR, 2.0TR) split type/window type AC (1.5/2.0) TR electric driven (single phase) comprising for split type AC one inner unit, one outer unit with servicing and installed at site including making connection with copper tubes from inner unit to outer unit including filling of refrigerant gas as required and electrically connecting up and testing, complete all as specified and as directed.
M&L Mild steel stand as per existing for testing AC Window type/Split type 1.5 to 2.0 TR capacity, grouting with Brick wall with Mild steel expandable bolts with steel rawl plug including making good walls in cement mortar (1:3) as required including Dismantling old unserviceable mild steel stand for AC’s complete all specified and as directed. Note:-The contract sum shall be arrieved at after deducting amount of schedule of credit from the total quated amount.
shashi bhushan gupta
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .