Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.6 LAccepted-AOC | L1 | Accepted-AOC Award | |
| 2 | L2₹26.4 L+₹45,352.75 (1.75%)Rejected-Finance | L2 | Rejected-Finance Being a not lowest bidder | |
| 3 | L3₹26.7 L+₹76,710.60 (2.96%)Rejected-Finance RAWALPORA WANABAL PATI YAYIL POST OFFICE SANAT NAGAR SRINAGAR 190005 J K | SRINAGAR | JAMMU AND KASHMIR | 190005 | L3 | Rejected-Finance Being a not lowest bidder | |
| 4 | L4₹29.8 L+₹3.9 L (14.9%)Rejected-Finance | L4 | Rejected-Finance Being a not lowest bidder |
Tender Value
₹33.5 L
EMD Value
₹67,000
Closing Date
3 Jan 2022, 6:00 pmClosed
GE 861 EWS
GE 861 EWS C/O 56 APO
PROVN OF 01 x VECHILE SHED TOILET BATH BLOCK AT KHUNMOH AND SPECIAL REPAIR TO BUILDING NO T 01 AT SHER E SHALI UNDER GE 861 EWS
2021_MES_492428_1
GE 861 EWS-67/2021-2022
Open Tender
Construction Works
Item Rate
180 days
GE 861 EWS
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE 861 EWS
₹67,000
Yes
9 Feb 2022
3 Dec 2021
5 Jan 2022
3 Dec 2021
3 Jan 2022
20 Dec 2021
Amount
Surface excavation n exc 30 cm deep and averaging 15 cm deep and getting out in hard/dense soil, complete all as specified and directed.
Excavation in trenches n exc 1.50m wide and n exc 1.50m in depth for foundation etc or for shaft wells, cesspits manholes pier holes etc n. exc 10 sqm on plan and n. exc 1.5m in depth and getting out in in hard/dense soil, complete all as specified and directed.
Excavation in trenches n exc 1.50m wide and n exc 1.50m in depth for foundation etc or for shaft wells, cesspits manholes pier holes etc n. exc 10 sqm on plan and exc 1.5m but n. exc 3.0m in depth and getting out in in hard/dense soil, complete all as specified and directed.
PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified.
RCC M-25 design mix using 20 mm graded aggregate in foundations, including rafts, footings, foundation beams, plinth beams, base for columns, etc basements slabs under rammed piles and mass concrete complete all as specified and directed.
RCC M-25 design mix using 20 mm graded aggregate in Column, pillars, piers, posts and struts complete all as specified and directed.
RCC M-25 design mix using 20 mm graded aggregate as in Beams cantilevers, bressummers lintels over 1.5 m span complete all as specified and directed.
RCC M-25 design mix using 20 mm graded aggregate as in slab supported on walls, beams and columns in floors, roofs landings balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
Form work to sides of concrete foundations, footings, bases of columns, raft beams sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter complete all as specified and directed.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions rough finish surface of concrete square, rectangular or polygonal complete all as specified and directed.
Form work to sides and soffits of floor or roof beam haunching , lintels, cantilevers shelved including supports overhangs etc also splays between floors and beams, etc complete all as specified and directed.
Form work to sides and soffits of suspended slab such as roof slab, floor slab, shelves and similar works n. exc. 200 mms thick (Horizontal or sloping), finishing rough the concrete surfaces, complete all as specified and directed.
MS TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking bending spirally for hopping for columns, hooking ends and binding with and including mild steel wire (annealed) not les than 0.9 mm dia or securing with clips quality conforming to complete all as specified and directed.
MS TMT Bars of 5 mm dia and over up to 10 mm dia in stirrups, spacers and binders, cut to length bent to shape required including cranking, binding spirally for hooping for columns hooking ends and binding with and including MS wire annealed not less than 0.9 mm dia or securining with clip complete all as specified and directed.
Brick work with sub class 'B' bricks straight or curved on plan, exceeding 6 m mean radius with old size bricks, built in cement mortar 1:6 complete all as specified and as directed.
Brick work with sub class 'B' bricks, straight or curved on plan, to any radius, in half brick thick wall, using old size brick, built in cement mortar 1:4, complete all as specified and directed.
10mm thick rendering on fair faces of brick or concrete surfaces in CM 1:4 finished even and smooth without using extra cement, complete all as specified and directed.
15mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:6 finished even and smooth without using extra cement, complete all as specified and directed.
Preparation of new plastered or unplastered surfaces of wall and applying two coat of distemper oil emulsion white tinted over a coat of primer, complete all as specified and directed.
Preparation of new plastered or unplastered surfaces of wall and applying two coats of cement base paint over a coat of alkali-resistant priming coat, complete all as specified and directed.
Sand filling under floors or in foundation including watering and consolidation, complete all as specified and directed.
Hard core of broken stone or boulders of guage n. exc 63mm, deposited, spread and levelled in layers n. exc 15 cm thick, watered and rammed to a true surface, complete all as specified and directed.
100mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in sub base of floors and pavings etc, complete all as specified and directed.
25 mm thick PCC 1:2:4, type B-0 (using 12.5 mm graded crused stone aggregate) as in floors to recieve floor finishes, complete all as specified.
Non-skid coloured ceramic tiles 7 to 8 mm thick (square / rectangular) area of each tile exc. 0.11 sqm but not exc 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM 1:6, complete all as spcified and directed.
Glazed ceramic coloured tiles 450mm x 300mm x 7mm thick as in vertical surfaces such as skirting dado etc set and jointed in neat cement slurry, pointed in white or coloured cement to match over and including 10mm thick rendering in cement mortar 1:4 to receive tiles, complete all as specified and directed.
Plain cement concrete M-10, 1:3:6, type C-2, using 40mm graded mechanically crushed stone aggregate, 75mm thick, as in plinth protection etc., surface finished even and smooth without using extra cement and laid to a slope of 1 in 24 in alternate panels n.exc. 1.20 Sqm each, 12mm wide and 5 cms deep joints shall be formed between the bays and shall be filled with mastic filling comprising a mixture of one part of heated blown bitumen VG-10 and two parts of heated coarse sand (by volume), all as specified and directed. Note:- The unit rate include for use of form work (straight or curved).
Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified, complete all as specified and directed.
Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding (eaves board) to wall fixed with self tapping screws as specified and directed.
Rolled mild steel as in joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) conforming to Fe-290W (Gde-E-165), complete all as specified and directed.
Mild steel work in hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165, complete all as specified and as directed.
Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded, complete all as specified and directed.
Steel ventilator with top hung shutter incl hinges, steel peg stay, including one shop coat of red oxide primer, complete all as specified and directed, complete all as specified and directed.
4mm thick sheet glass ordinary quality, and glazing with oil putty or fixed with bead/glazing pins in squares n.exc 0.50 Sqm in each pane, including hacking out old glass panes, complete all as specified and directed.
4mm thick figured glass pin head type and glazing with oil putty in squares not exceeding 0.50 Sqm in each pane, complete all as specified and directed.
Mild steel in framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165, complete all as specified and as directed.
Preparation of new or previously untreated steel surface any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Factory made solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplying & fixing in opening as per specification & drawing shown in SSR Part-II, complete all as specified and directed.
Factory made solid panel PVC door shutter 30mm thick (stile) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC channel having a PVC sheet strip of 20mm width struck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rails and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to in stiles & rails with suitable PVC sheet beading and joinned together with solvent cement supplying & fixing in frames at site as per specification and drawing shown in SSR Part -II, complete all as specified and directed.
250mm size aluminium alloy, anodised, sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy, complete all as specified and directed.
150mm long, aluminium, anodised, barrel tower bolts of extruded section, complete all as specified and directed.
150mm long, extruded aluminium alloy handles, fabricated type, anodised, all as specified and directed.
100 mm long, mild steel cold rolled butt hinges, medium weight, complete all as specified and directed.
Vitreous china squatting pan water closet, orissa pattern, size 580x440mm white with integral foot rests (excluding flushing cistern and flush pipe) including cast iron 'P' or 'S' trap, jointing to flush pipe complete including cement concrete M-5 (1:5;10), type E-2 using 40mm graded crushed stone aggregate, complete all as specified and directed.
Stainless steel grating doom 125mm dia, complete all as specified and directed
Vitreous china urinals, bowl type 465x355x265 mm white, providing & fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with flush pipe, grating and union for discharge pipe complete all as specified and directed.
10 litre capacity PVC valveless, low level, synphonic action type, flushing cistern, with inlet, ball valve, float valve, handle including brackets, complete all as specified and directed.
Vitreous china, wash hand basin, coloured, round shape, of size 550mmx400mm including brackets and pedestal, including brass, chromium plated, waste coupling 32mm dia with long screwed shank and fly nuts and 15mm bore dia pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts,screwed for iron pipe and fixed, complete all as specified and directed.
PVC connection 15mm size with PTMT nuts of length 600mm, complete all as specified and directed.
Swivel shower of PTMT with shower arm 15 mm size, 195mm long with bend of 45degree with flange of PTMT any colour for fixing with 15mm pipe, complete all as specified and directed.
100mm cast iron sanitary connection socket to fit WC outlet, complete all as specified and directed.
75mm cast iron nahani trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4), complete all as specified and directed.
15mm bore bib tap, fancy type, chromium plated, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule,complete all as specified and directed.
15mm bore stop valves, fancy type, chromium plated, cast copper alloy, screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipe or union, complete all as specified and directed.
Rotational moulded polythylene 500 litres capacity water storage tank (Cylindrical vertical with closed top), 3 layer hoisted and fixed in position including 20mm brass ball valve high pressure with brass rod & high density plastic ball complete all as specified and directed.
Tubular towel rail, CP brass, 20mm dia, D type 60 cm long between flanges, complete all as specified and directed.
Supply, fixing, jointing and testing, ISI Marked, of approved quality, gun metal globe/gate valve 20mm dia with iron wheel head, both ends screwed for iron pipe complete all as specified and directed.
75mm bore dia PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors etc, complete all as specified and directed.
110mm bore dia PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors etc, complete all as specified and directed.
75mm bore dia PVC (SWR) bends, complete all as specified and directed.
75mm bore pipe PVC (SWR) vent cowl and fixed, complete all as specified and directed.
Steel water tubing, 15 mm bore, galvanised, "medium grade" with all fittings and fixtures and short lengths, fixed to wall and ceiling or laid in floor, complete all as specified and directed.
Steel water tubing, 20 mm bore, galvanised, "medium grade" with all fittings and fixtures and short lengths, fixed to wall and ceiling or laid in floor, complete all as specified and directed.
Plain cement concrete bed 1:4:8 type D-2 (using 40mm graded crushed stone aggregates)to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested for 150mm bore pipe, complete all as specified and directed.
Salt glazed stone ware drain pipe of 150mm bore (internal bore) garde 'A' laid in trenches and jointed, complete all as specified and directed.
Precast cement concrete type 1: 2: 4, type-B1 (20 mm graded aggregate) as in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces, set and jointed in CM 1:4, complete all as specified and directed.
Cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork, complete all as specified and directed.
Returning filling in (soil) including spreading, levelling , watering and well ramming in layers n exc 25cm thick, complete all as specified and directed.
Removing of surplus soil to a distance n exc 50 mtr and depositing where directed at a level n exc 1.5 mtr above the starting point, complete all as specified and directed.
Brick work with sub class 'B' bricks in one brick thick honey-comb walling, built in cement mortar 1:4, complete all as specified and directed.
Surface dressing not exceeding 30 cm deep and averaging 15 cm getting out in hard/dense soil, complete all as specified and directed.
Rolled mild steel in roof trusses (framed),trussed ,purlins,crane girders,purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., conforming to Fe-410-W (Gde-E-250) quality-A, complete all as specified and directed.
Rolled mild steel in plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment, etc., and similar small articles, conforming to Fe-290 (Gde-E-165), complete all as specified and directed.
75mm thick, PCC 1:2:4 type B-2 (using 40 mm graded crushed stone aggregate) as in floor laid in alternate bays(size of each panel 1.20x1.20m) including spike rolling to surfaces or making impressions of expanded metal, whilst the concrete is green and joints filled with mastic filling, including necessary formwork, complete all as specified and directed.
Extra for forming fair finished drain or channel 30cm inner girth in cement using extra cement including forms, moulds, mitered / stopped ends etc., complete all as specified and directed.
Preparation of new plastered or unplastered surfaces of walls and applying three coats of white wash,complete all as specified and directed.
Taking down cement plaster on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors & pavings n.exc 15 cm thickness (below or above ground level), complete all as specified and directed.
Dismantling timber framed scantling 40 sq cm and over in section in any position, complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, Pulp, insulation etc) or insulation board/slabs/blankets, any thickness, including cover fillets etc, complete all as specified and directed.
Taking down chowkats or frames with shutters (w/o taking of shutters from the frame) exc 1.5 but n exc n.exc 4 Sqm each, complete as specified and directed.
Taking down chowkats or frames including shutters (without taking off shutters from the frames) not exceeding 1.50 Sqm each, complete all as specified and directed.
Taking down shutters of any description exceeding 1.00 Sqm and not exceeding 2.00 Sqm each, and removing from site, complete all as specified and directed.
Dismantling plain or corrugated steel sheeting , any gauge and thickness, including Nainital or similar pattern roof coverings, complete all as specified and directed.
Demolition of brick work or stone / boulder masonry, built in cement mortar, including all quoins, arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles etc, complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing, removing serviceable tiles to store and rubbish off the premises,complete all as specified and directed.
Brick work with sub class 'B' bricks straight or curved on plan, exceeding 6 m mean radius with old size bricks, built in cement mortar 1:4 complete all as specified and as directed.
All as per srl item No-88 here in above but except bricks, complete all as specified and directed.
2nd class hard wood, plain, solid, straight chowkats and frames, wrought, framed, worught, framed rebated on the solid, rounded of chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads, complete all as specified and directed.
35 mm thick 2nd class hardwood plain (Sal/ Hollock) factory made, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers supplied and fitted to chowkats, complete all as specified and as directed.
35mm thick, 2nd class hard wood (Sal/ Hollock) factory made glazed and skeleton shutters, open rebated and prepared to receive glass or gauge,etc. (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut & mitred beads for securing gauge sizes of members of shutters as specified in SSR Part-I Section-8, clause 8.24 (a) for door shutter supplying and fitted to chowkats, complete all as specified and directed.
30 mm thick, 2nd class hard wood (Sal/ Hollock) factory made glazed and skeleton shutters, open rebated and prepared to receive glass or gauge,etc. (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut & mitred beads for securing gauge sizes of members of shutters as specified in SSR Part-I Section-8, clause 8.24 (b) for door shutter supplying and fitted to chowkats, complete all as specified and directed.
300mm size aluminium alloy, anodised, sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy, complete all as specified and directed.
100mm long, extruded aluminium alloy handles, fabricated type, anodised, all as specified and directed.
75 mm long, mild steel cold rolled butt hinges, medium weight, complete all as specified and directed.
100mm thick PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) as in sub base of floor, complete all as specified and directed.
Non-skid coloured ceramic tiles 7 to 8 mm thick (square / rectangular) area of each tile exc. 0.18 sqm but not exc 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM 1:6, complete all as spcified and directed.
15mm thick rendering on other than fair faces of brick work or concrete surfaces in CM 1:4 finished the surface even and smooth without using extra cement, complete all as specified and directed.
Preparation of new plastered surfaces of wall to receive 3mm thick wall care putty and applying two coats of oil bound distemper over a coat of primer, complete all as specified and directed.
Complete removal of existing treatment of walls & applying two coats of oil bound distemper white or tinted over a coat of alkaline resistant primer and 3 mm thick wall care putty, complete all as specified and directed.
Complete removal of existing treatment of walls and applying two coats of cement base paint over a coat of alkali resistant primer, complete all as specifed and directed.
Preparation of new wooden surfaces of any description not otherwise described, exc 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer, complete all as specified and directed.
Preparation of old painted wooden surcaces of any description not otherwise described over 10 cm width or girth and applying one coats of synthetic enamel paint, complete all as specified.
Anodised aluminium snap grid of size 605 x605 mm frame work for false ceiling including Hangers 6 mm dia MS rod (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long, complete all as specified and directed.
10 mm thick PVC insulation panels with EPS stuck to 1 mm thick plain PVC sheet suitably placed in false celing grid made of aluminim GI/MS as per specification and drawing complete all as specified and directed.
S&F in repair stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with stainless steel wire staples,complete all as specified and directed.
Plain cement concrete M-10, 1:3:6, type C-2, using 40mm graded mechanically crushed stone aggregate, 50mm thick, as in plinth protection etc., surface finished even and smooth without using extra cement and laid to a slope of 1 in 24 in alternate panels n.exc. 1.20 Sqm each, 12mm wide and 5 cms deep joints shall be formed between the bays and shall be filled with mastic filling comprising a mixture of one part of heated blown bitumen VG-10 and two parts of heated coarse sand (by volume), all as specified and directed. Note:- The unit rate include for use of form work (straight or curved).
2nd class soft wood as in scantlings and similar work, clean sawn, timber framed and fixed in position, complete all as specified and directed.
Chequered coloured cement concrete tiles, glossy finished of size 300 x 300 x 25 mm thick, with grey cement and pigment, set, jointed and pointed in neat cement slurry, laid in floors, over and including 15 mm thick screed bed in cement mortar 1:6, complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including unscrewing from board fitting and fixture such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody for reuse if serviceable or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
Point wiring with 1.5 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable 1100 volts grade single core conforming to IS-694-1990 and including one run of continous earth wire to common earth and connected to earth with 1.5 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable draw in & incl PVC surface casing 'N' capping double lock type to be fixed with the help of rawal plugs & screws incl necessary fittings & fixture and to be turminated in sunk cast iron/pressed steel/PVC terminal boxes for mounting switches, sockets, regulators etc with 3 mm thick plastic laminated sheet cover of adequate size for one light / fan/ bell point controlled by one switch one way and making good disturbed surfaces with CM (1:3) to match with the existing surface, complete all as specified and directed.
All as per srl item No-113 here in above but for one 3 pin 5A socket outlet independent controlled by one switch, complete all as specified and directed.
All as per srl item No-113 here in above but for one 5A socket outlet on the same board controlled by one switch, complete all as specified and directed.
All as per srl item No-113 here in above but for one 3 pin 15 Amps socket outlet independent with 2.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 2.5 Sqmm PVC FRLS insulated unsheathed copper conductor single core cable (green color) as earth lead.
Switch piano flush button types 5/6 Amp, single pole, one way complete all as specified and directed.
Switch socket combination 2 in 1, outlet 5 pin, 5 Amp flush type, universal, complete all as specified and directed.
Switch socket combination 2 in 1, 5/6 pin, 5 and 15 Amp, flush type universal complete all as specified and directed.
Supply and fixing in replacement fan regulator electronic, step type hum free suitable to control speed of fan from 0 to 100% and connecting electrically all as required at site or directed.
Ceiling rose 3 terminal bakelite 65mm x50mm surface type, PVC/Polycarbonate, isolated body, complete all as specified and directed.
Lamp holder, PVC/ Polycarbonate type with back plate, straight/ angular, suitable for batten fittings, complete all as specified and directed.
Supply only LED lamp 9watt (WW), complete all as specified and directed.
LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and directed.
LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed.
Supply & install environmental friendly, ultra modern, energy saving bulk head 8W in die cast aluminium housing & frosted glass complete all as specified and directed. Cat Part No LHKL01160099 in Havells or equivalent in Philips/C&S/Bajaj/Halonix.
Sub main wiring with two single core PVC insulated flexible copper conductor cable of size 6.0 sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 6.0 Sqmm as earth lead in & including concealed PVC casing capping medium grade 2mm thickness ISI marked or cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification incl taking down old unsv, complete all as specified and directed.
Supply and fix in repair sheet metal enclosure MCB distribution board, single pole and neutral double door with IP-43 protection single phase 240 volts 12 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.
Supply and fix in repair sheet metal enclosure MCB distribution board, single pole and neutral double door with IP-43 protection single phase 240 volts 4 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.
M&L in repair for MCB single pole and neutral 240 volts 32 amps as per site requirement , with rupturing capacity 10 KA as per IS-8828-1996 (IEC-60898), biconnect upper and lower terminals , integrated label holder to ensure circuit identification complete all as specified and directed.
M&L in repair for MCB single pole 240 volts 6 to 32 amps as per site requirement , with rupturing capacity 10 KA as per IS-8828-1996 (IEC-60898), biconnect upper and lower terminals , integrated label holder to ensure circuit identification complete all as specified and directed.
Supply and fixing in repair change over switch,4 pole, on load 415 volts in sheet metal enclosure of capacity 40 Amps, complete all as specified and as directed.
Supply laying connecting and testing in replacement of 1100 volt graded heavy duty XLPE cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanized steel strip or wire and overall PVC sheathed of size 16 Sqmm normal cross section 4 core including suitable size lugs laid in trenches fixed to pole or passing through pipes incl all necessary clamps nuts, bolts and washers and remove unsv cable complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level. connecting to the GI wire 4 mm dia by means of bolls, nuts, check nuts and washers of galvanised iron and earth wire protected by provision of GI light grade pipe 15mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and handle of 6mm dia MS bar made to shape, GI medium grade 20mm bore pipe for watering , perforated at bottom. 1.75 metre long placed on top edge of earth plate. charcoal and common salt filling with fixing arrangement, funnel wire mesh and earth work in soft soil returning filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electrical plate 3 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion. NOTE :- (i) Item of earthing includes cost of 7.5 m long GI wire of size 4 mm dia with protection pipe of 15mm dia GI medium grade, any variation in length shall be adjusted through deviation order based on SSR rates enhanced by (-) 14.50% (MINUS). (ii) On testing after completion of earthing if the desired earth resistance is not obtained earthing will be re-done by the contractor at his own risk and cost.
Supply laying connecting and testing of 1100 volt graded heavy duty XLPE cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanized steel strip or wire and overall PVC sheathed of size 16 Sqmm normal cross section 2 core including suitable size lugs laid in trenches fixed to pole or passing through pipes incl all necessary clamps nuts, bolts and washers, complete all as specified and directed.
Sub main wiring with two single core PVC insulated flexible copper conductor cable of size 2.50 sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 2.50 Sqmm as earth lead in & including concealed PVC casing capping medium grade 2mm thickness ISI marked or cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification, complete all as specified and directed.
25 watt LED security light, energy saving and environment friendly light fitting with housed in pressure die-cast aluminium housing with sealed toughened glass cover, SMD LED with secondary lens luminaires with IP-66 protection including all fixing accessories such as bracket etc, complete all as specified and directed. Make : C&S Cat Part No LTESS25WLED/LS or Equivalent in Havells/Philips/Bajaj/Halonix.
Earthing complete with galvanised cast iron earth plate electrode of size 600x600x6 mm thick buried directly in ground less than 3.0m deep below normal ground level as earth electrode with top edge of the earth plate not less than 2.25mtr below ground level using GI strip 32x6mm as earth continuity conductor connected to earth plate by means of welding, GI thimbles, nuts, bolts & washers all as directed including providing earth wire protection pipe GI light grade 40mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover with handle of angle iron frame of size 40 x 40 x 6mm in PCC 1:3:6 adequate quantity of charcoal dust and salt and kalmi shore all around the earth plate, earth work in any type of soil remaining surplus excavated material all as required at site and specified in EP No 3 of SSR part I 2009 or directed by Engineer-in-charge and incl testing on completion. NOTE :- (i) Item of earthing includes cost of 7.5 m long GI strip of size 32x6mm with protection pipe of 40mm dia GI medium grade, any variation in length shall be adjusted through deviation order based on SSR rates enhanced by (-) 14.50% (MINUS). (ii) On testing after completion of earthing if the desired earth resistance is not obtained earthing will be re-done by the contractor at his own risk and cost.
MCB single pole and neutral 240 volts 40-63 amps as per site requirement , with rupturing capacity 10 KA as per IS-8828-1996 (IEC-60898), biconnect upper and lower terminals , integrated label holder to ensure circuit identification complete all as specified and directed.
MCB single pole 240 volts 6 to 32 amps as per site requirement , with rupturing capacity 10 KA as per IS-8828-1996 (IEC-60898), biconnect upper and lower terminals , integrated label holder to ensure circuit identification complete all as specified and directed.
Sub main wiring with two single core PVC insulated flexible copper conductor cable of size 6.0 sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 6.0 Sqmm as earth lead in & including concealed PVC casing capping medium grade 2mm thickness ISI marked or cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification, complete all as specified and directed.
Supply laying connecting and testing of 1100 volt graded heavy duty XLPE cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanized steel strip or wire and overall PVC sheathed of size 10 Sqmm normal cross section 2 core including suitable size lugs laid in trenches fixed to pole or passing through pipes incl all necessary clamps nuts, bolts and washers, complete all as specified and directed.
Excavation in trenches n exc 1.50m wide and n exc 1.50m in depth for foundation etc of poles/stays/cables etc and getting out in hard/dense soil, complete all as specified and directed.
Sand cushioning to underground cable as per clause No 19.75 of SSR Part-I laid with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable. The top layer of 15cm shall be punned to 10 cm (total 23 cm) complete all as specified and directed.
Bricks laid in trenches flat with width equal to length of brick for cable protection well burnt sub class 'B' laid across the cable, complete all as specified and directed.
Lagging to 20mm bore GI pipes used in external water supply of plumbing all around with 25mm thick bonded mineral wool pre-formed. SNAPON pipe section of density 144 Kg/Cum conforming to IS-9842 or equivalent and provided chicken wire mesh netting 25gauge 20mm meshing and plaster of Peris 3 to 5 mm thick all around the mesh, complete all as specefied and directed
Cutting of existing CI water main line in position in trenches of size upto 100mm dia for insertion of tee for taking branch connection including excavation, earthwork etc., complete all as specified and directed.
M/S MOHAMMAD SHABAN AND CO
FIRDOUS AHMAD BABA
NAJAR ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .