Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
21 May 2024, 4:00 pmClosed
GE NORTH KOLKATA
GE NORTH KOLKATA 46 BT ROAD KOLKATA 50
REPAIR/ MAINT OF COOLING APPLIANCES SUCH AS ACs, WATER COOLER, REFRIGERATOR, DEEP FREEZER ETC IN KOLKATA AREA UNDER GE (NORTH) KOLKATA
2024_MES_648487_1
8357/24-25/GE(N)/KOL/E8 OF 2024-25
Open Tender
Miscellaneous Works
Item Rate
270 days
KOLKATA AREA
AS PER TENDER DOCUMENT
8 documents required · 8 mandatory
₹500
GE NORTH KOLKATA
₹80,000
Yes
11 Jun 2024
30 Mar 2024
22 May 2024
31 Mar 2024
21 May 2024
15 Apr 2024
Amount
Material and labour for taking down window type Air Conditioner of upto 2 TR,cleaning by water , thoroughly, cleaning by caustic and re-washing with plain water, Servicing. greasing,replacing of spares required, and refixing at same location with proper rectification of leakage and commissioning , etc complete, all as directed by the Engr-in-Charge. Existing makes of AC:- LG / Samsung / Voltas / Videocon/As per existing. Notes:- (i) The spares listed herein after shall be measured and paid as supply only. The spares incorporated shall be of existing make / suitable for the make of AC (ii) Filling of gas shall be measured and paid seperately, under supply only. (iii) Cost of any other spares / minor spares, not specified here in after, and the spares like nut bolts washers etc shall be deemed to be included in the unit rate quoted.
Dismantling covers of out-door and in-door units of split type Air Conditioner of capacity upto 2.0TR, cleaning completely the condenser coil and cooling coil initially with hand blower, spraying with soap water solution and finally clean with clear water, Servicing. greasing,replacing of spares required, re-fixing the covers with proper rectification, in same position complete as directed by the Engineer-in-Charge. Existing makes:- LG / Samsung / Voltas / Videocon/As per existing Notes:- (i) The spares listed herein after shall be measured and paid as supply only. The spares incorporated shall be of existing make / suitable for the make of AC (ii) Filling of gas shall be measured and paid seperately, under supply only. (iii) Cost of any other spares / minor spares, not specified here in after, and the spares like nut bolts washers etc shall be deemed to be included in the unit rate quoted..
Material and labour for taking down water cooler of upto 150 ltr,cleaning by water , thoroughly, cleaning by caustic and re-washing with plain water, Servicing. greasing,replacing of spares required, and refixing at same location with proper rectification of leakage and commissioning , etc complete, all as directed by the Engr-in-Charge. Existing makes of AC:- LG / Samsung / Voltas / Videocon/As per existing. Notes:- (i) The spares listed herein after shall be measured and paid as supply only. The spares incorporated shall be of existing make / suitable for the make of AC (ii) Filling of gas shall be measured and paid seperately, under supply only. (iii) Cost of any other spares / minor spares, not specified here in after, and the spares like nut bolts washers etc shall be deemed to be included in the unit rate quoted.
Material and labour for taking down refrigerator of upto 340 ltr,cleaning by water , thoroughly, cleaning by caustic and re-washing with plain water, Servicing. greasing,replacing of spares required, and refixing at same location with proper rectification of leakage and commissioning , etc complete, all as directed by the Engr-in-Charge. Existing makes of AC:- As per existing. Notes:- (i) The spares listed herein after shall be measured and paid as supply only. The spares incorporated shall be of existing make / suitable for the make of AC (ii) Filling of gas shall be measured and paid seperately, under supply only. (iii) Cost of any other spares / minor spares, not specified here in after, and the spares like nut bolts washers etc shall be deemed to be included in the unit rate quoted.
M&L, in repair, for Jointing capillary tubes filter strainer by brazing, cleaning / flushing whole the system, checking any leakage and make good including testing 350 PSI complete for Window type AC of capacity upto 2.0 TR
All as per item No. 5 above but, Split type AC of capacity of capacity upto 2.0 TR.
All as per item No. 5 above but,Refrigerator of capacity upto 340 ltr
All as per item No. 5 above but, Water cooler of capacity upto 150 ltrs
Dismantling of blower fan motor cutting burnt coils and taking out from the stator, cleaning the stator using petrol, rewinding using supper enameled copper wire of existing size and gauge including insulation materials change of bush (front and rear) made out of gun metal and reassembling all accessories and testing complete all as directed for Window type AC of capacity upto 2 TR. Notes:- (i) The unit rate quoted shall be deemed to including for rewinding also.
Dismantling of blower fan motor cutting burnt coils and taking out from the stator, cleaning the stator using petrol, rewinding using supper enameled copper wire of existing size and gauge including insulation materials change of bush (front and rear) made out of gun metal and reassembling all accessories and testing complete all as directed for Split type AC of capacity upto 2.0 TR Notes:- (i) The unit rate quoted shall be deemed to including for rewinding also.
Dismantling of blower fan motor cutting burnt coils and taking out from the stator, cleaning the stator using petrol, rewinding using supper enameled copper wire of existing size and gauge including insulation materials change of bush (front and rear) made out of gun metal and reassembling all accessories and testing complete all as directed for Water Coolers of capacity upto150 litres. Notes:-(i) The unit rate quoted shall be deemed to including for rewinding. .
Repair body and base of water cooler including providing plain MS Sheet of existing gauge / thickness and angle iron of existing thickness and size including necessary welding / brazing repair of leakage in water tank of water cooler, by arc welding after necessary leak testing,, including preparing the steel and iron surface and spray painting with synthetic enamel paint, glossy finish / shop finish, as directed by the Engineer- In- Charge,etc complete, of capacity upto150 litre.
Supply only, Running capacitor 10-36 mfd for 1.5/1.0/2.0 TR capacity window type/split type Air Conditioner. (Make for item Nos. 13 & 14 : Univeral/ Sarda / Usha / Copco / HPL / L&T / Existing make duly approved by the GE. )
All as per item No. 13 above but, Running Capacitor 4 mfd
All as per item No. 13 above but, Capillary Tube (copper) as per exixting size
All as per item No. 13 above but, Filter strainer
All as per item No. 13 above but, Starting relay
All as per item No. 13 above but, Air filter made of plastic frame and nylon net
All as per item No. 13 above but,Thermostat switch make - Indfos or equivalent
All as per item No. 13 above but, Contactor relay for split type AC.
Supply only, Starting /Running capacitor 45/ 50 Mfd + 6 MFD upto 2 ton split type AC.(Make : SARADA / UNIVERSAL / Usha / Copco / HPL / L&T / Existing make)
Supply only Blower motor for window type AC 1.5 Ton capacity.(as per existing make such as Blue Star, carrier, Usha, Voltas,LG, Amtrex etc)
All as per item No. 23 above but, Blower motor for window type AC 2 Ton capacity.(as per existing make such as Blue Star, carrier, Usha, Voltas,LG, Amtrex etc)
All as per item No. 23 above but Blower motor for Split type AC upto 2 Ton capacity.(as per existing make such as Blue Star, carrier, Usha, Voltas,LG, Amtrex etc).
Supply and fix in repair, Front grill for, Window type AC of capacity 1.5 TR.(as per existing make such as Blue Star, carrier, Usha, Voltas,LG, Amtrex etc)
Supply and fix in repair, Front grill for, Window type AC of capacity 2 TR. (as per existing make such as Blue Star, carrier, Usha, Voltas,LG, Amtrex etc)
Supply and fix in repair, PCB Board for split type, of capacity 1.0 TR AC.(as per existing make such as Blue Star, carrier, Usha, Voltas,LG, Amtrex etc)
Supply and fix in repair, PCB Board for split type, of capacity 1.5 TR AC.(as per existing make such as Blue Star, carrier, Usha, Voltas,LG, Amtrex etc)
Supply and fix in repair, PCB Board for split type, of capacity 2.0 TR AC.(as per existing make such as Blue Star, carrier, Usha, Voltas,LG, Amtrex etc)
Supply only Rubber bushing for blower motor of suitable and exixting capacity AC
Supply and fix in repair, Swing motor for split type AC of capacity upto 2.0 TRMake:- (as per existing make)
Supply and fix in repair, Swing motor for window type AC of capacity 2.0 TR.Make:-(as per existing make).
Supply and fix in repair, Display assembly for spilit type AC of capacity 2.0 TR.Make:- (as per existing make)
Supply and fix in repair, Display assembly for WINDOW type AC of capacity 2TR Make:- (as per existing make)
Supply and fix in repair, Display assembly for DEEP FREEZER type AC of capacity 500 ltr.Make:- (as per existing make)
Supply and fix in repair, Sensor for Indoor unit of Split type AC, of capacity Upto 2.0 TR.Make:- (as per existing make)
Supply and fix in repair, Service line charging valve 5/8'' (Brass).Make:- (as per existing make)
Supply and fix in repair, Liquid line valve 1/4'' (Brass).Make:- (as per existing make)
Supply and fix in repair, PCB Board for window type AC upto 2 .0 TR. Make:- (as per existing make of Blue Star, carrier, Usha, Voltas,LG, Amtrex etc)
Supply and fix in repair, condenser coil of copper for split type AC, of capacity 1.5 TR Make:- (as per existing make)
Supply and fix in repair, condenser coil of copper for split type AC, of capacity 2.0 TR Make:-(as per existing make)
Supply and fix in repair, condenser fan for AC of 1.0 TR/1.5 TR / 2.0 TR, Make:- (as per existing make)
M & L for sub main wiring with 2 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm alongwith one run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4 sqmm as earth continuity conductor drawn through PVC casing-caping surface type all as directed. Note:- 3 runs of cable, 1 run of casing-caping shall be measured and paid as one unit i.e Rm. Make of cable:- MESCAB / POLYCAB / HAVELLS / KEI / FINOLEX. Make for casing-caping :- Plaza / Presto Plast / Precision/ M/S AGK Industries
Supply and fixing in repair rotary sealed unit Compressor for window/split AC of 1.5 Ton capacity.Make :Tecumseh/ Kirloskar/ Emarson compland/ Wirlpool.
M & L for sub main wiring with 2 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm alongwith one run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6 sqmm as earth continuity conductor drawn through PVC casing-caping surface type all as directed. Note:- 3 runs of cable, 1 run of casing-caping shall be measured and paid as one unit i.e Rm. Make of cable:- MESCAB / POLYCAB / HAVELLS / KEI / FINOLEX. Make for casing Caping:- Plaza / Presto Plast / Precision/ M/S AGK Industries
Supply and fixing in repair rotary sealed unit Compressor for window/split AC of 2 Ton capacity. Make : Tecumseh/Emarson compland/Wirlpool/Kirloskar
Supply and fixing in repair Refrigerator compressor capacity upto 340 Ltrs. Make: Tecumseh/Kirloskar/Emarson compland/Wirlpool.
Supply and fixing in repair Water cooler compressor capacity above 40 and upto 150ltrs. Make :Tecumseh/Kirloskar/Emarson compland/Wirlpool.
Supply and laying in repair refrigerant line copper tubing of size 5/8 " with clamping on wall surface or concealed with both the ends connection complete.
All as per item Ser No 50 ( here - in - before) but of size 1/4 "
All as per item Ser No 50 ( here - in - before) but of size 1/2 "
S & F in repair foam insulation/ keniform for copper tubing of size 1/2" and 1/4'' dia.
S&F in repair flexible drain pipe for split type AC.
Supply and fixing in repair, Condenser coil. for various capacity of refrigerator.
Supply and fixing in repair, Pin/Thread type lamp holder
Supply and fixing in repair, Bulb 15 watt (Pin/Thread type)
Supply and fixing in repair, Ice tray
Supply and fixing in repair Open type relay with overload protector
Supply and fixing in repair Thermostat auto defrost
Supply and fixing in repair Capillary tube (copper) as per existing.
Supply and fixing in repair Chill tray
Supply and fixing in repair Ice Chamber upto 340 Ltr.
Supply and fixing in repair Vegetable box
Supply and fixing in repair Bimetal Relay
Supply and fixing in repair Heating Element
Supply and fixing in repair Frost free fan motor
Supply and fixing in repair Timer. Note:- All the makes for serial item Nos. 52 to70 as per existing.
Supply and fixing in replacement, Push type tap copper alloy chromium plated 15 mm bore. the following materials/accessories suitable for upto150 ltrs capacity water cooler-
All as per item No. 69 but, Rubber lining for top cover gasket of capacity upto 150 litre.Water Cooler
Supply only, Starting relay suitable for 5/8 HP motor of water cooler make SHRIRAM
Supply only Starting capacitor 80/100 mfd for water cooler (Make Universal/ SARADA or equivalent)
Supply only Thermostat (Make : Indofons/shriram/or equivalent)
Supply and fix in repair, Float valve Brass with fly nut, of dia / bore 15 mm , etc complete screwed as per existing.
Supply only, Over load protector Make : SHRIRAM or equivalent
Supply only Capilary tube as per existing size (Copper).
Supply only Blower motor as per existing.
Supply only CP Basin tray.
Supply only Running capacitor 15 mfd (Make Universal/ SARADA or equivalent).
Supply and charging refrigeration gas R-22 for Split/window AC confirm with N2 pressure testing and flushing the system with liquid nytrozen, dehydration and evacuation the system all as specified and directed by Engr-in-charge Make: Mafron or equivalent .
Dismantling, shifting and refixing of split type AC of capacity 1.5 to 2.0 TR including proper arrangement to keep outer unit (Angle iron with nut bolt) safely without gas leakage, in the unit complete all as specified and directed by Engr-in-charge.
S & F in repair for sheet metal enclosure single pole and neutral with two pin and earth plug complete with one single pole MCB 20 Amps 240 volt. Make: Havells/Legrand/L&T / Indoasian / HPL / Standard).
Material and labour for cutting holes in brick wall for fixing of window type Air Conditioner including removal of rubbish from the site of work within 50 m distance including necessary, second class hard wood, wooden frame work not less than 2" by 2" thick and size as per AC model including plastering 10 mm thick in CM 1:6, side walls in cement mortar 1:6 and white wash / distemper complete, to match the existing surface, including preparation of new wooden surfaces and applying 2 coats of synthetic enamel paint, first quality, over a coat of pink primer, etc complete. all as directed by the Engr-in-Charge. Make of paint:- Asian / Berger / Jenson & Nicholson / Berger.
Taking down out door unit of 1.5TR/2.0 TR capacity removing unserviceable AC stand/angle iron bracket fixing new AC stand/angle iron bracket in repair (including two coats of sunthetic enamel paint over a red oxide primer) fixing to the wall by foundation bolts refixing the out door unit connection the suction and discharge line complete testing and running all as directed by the Engr-in-charge.
Dismantling and taking out voltage stabllizer transformer unit, auto transformer varier, electric circult board, all cable connections, including repairing/replacement of push on switch, transistor, capacitor, relay transistor, diode, condenser, voltmeter, PVC connector, indicator lamp, cutout, MCB complete parts along with testing commissioning and trasportation charges from site to workshop all as directed of capacity Upto 2 KVA
All as per item No. 85 but, 03 KVA to 5 KVA capacity
Supply and fixing in replacement indoor unit of split ac of capacity 1.5 TR with all accessories including taking down of old unserviceable indoor unit complete all as directed by the Engr-in-Charge (as per existing make such as Blue Star, carrier, Usha, Voltas,LG, Amtrex etc)
Supply and fixing in replacement outdoor unit of split ac of capacity 1.5 TR with all accessories including taking down of old unserviceable indoor unit complete all as directed by the Engr-in-Charge (as per existing make such as Blue Star, carrier, Usha, Voltas,LG, Amtrex etc)
Supply and fix modular plate with starter plug and socket AC single phase, 230 Volts, 25 Amps capacity, including metallic mounting box including taking down the old unserviceable modular plate with starter plug and socket all as specified and as directed. Make :Crabtree /havells/C&S/Standard or equivallent)
Dismantling of exist unserviceable plug top and Supply & fixing in repair 15 Amp plug top complete with all connection, complete all as specified and as directed. MAKE:- Anchor / Cona / Bajaj / Crabtree / Havells / HPL / C&S / Standard
Supply and fixing in replacement indoor unit of split ac of capacity 2 TR with all accessories including taking down of old unserviceable indoor unit complete all as directed by the Engr-in-Charge (as per existing make such as Blue Star, carrier, Usha, Voltas,LG, Amtrex etc)
Supply and fixing in replacement outdoor unit of split ac of capacity 2 TR with all accessories including taking down of old unserviceable outdoor unit complete all as directed by the Engr-in-Charge (as per existing make such as Blue Star, carrier, Usha, Voltas,LG, Amtrex etc)
Dismantling deep freezer, any capacity,cleaning by water , thoroughly, cleaning by caustic and re-washing with plain water, Servicing. greasing,replacing of spares required, and refixing at same location with proper arrest of leakage and commissioning , etc complete, all as directed by the Engr-in-Charge. Notes:- (i) The spares listed herein after shall be measured and paid as supply only. (ii) The labour element involved in replacing the spares is deemed to include in the quoted rate. (iii) Filling of gas shall be measured and paid seperately, under supply only. (iv) The contractor shall take cognizance of the above aspects and quote the unit rate. (v) Cost of any other spares / minor spares, not specified here in after, and the spares like nut bolts washers etc shall be deemed to be included in the unit rate quoted. (vi) Rewinding shall be measured and paid separately under relevant items. (vii) The decission of GE shall be final and binding.
Supply only Blower motor suitabli for deep freezer upto 500 ltrs capacity Make: as per existing. Tecumseh/Kirloskar/Emarson compland/Wirlpool/voltas/samsung etc.
Supply only sealed compressor for deep freezer upto 500 ltrs capacity. Make: Tecumseh/Kirloskar/Emarson compland/Wirlpool.
M&L for painting with DUCO paint, first quality,t (ISI grade) white using spray machine spray painting including cleaning, washing, preparation of old painted surfaces complete all as directed by Engineer-in-Charge for Window type AC's upto 2.00TR- Make:- Asian / Berger / Jenson & Nicholson / Shalimar.
M&L for painting with DUCO paint, first quality,t (ISI grade) white using spray machine spray painting including cleaning, washing, preparation of old painted surfaces complete all as directed by Engineer-in-Charge for Split type AC's upto 2.00TR capacity :- Make:- Asian / Berger / Jenson & Nicholson / Shalimar.
M&L for painting with DUCO paint, first quality,t (ISI grade) white using spray machine spray painting including cleaning, washing, preparation of old painted surfaces complete all as directed by Engineer-in-Charge for Refrigerator of upto 340 ltr capacity Make:- Asian / Berger / Jenson & Nicholson / Shalimar.
M&L for painting with DUCO paint, first quality,t (ISI grade) white using spray machine spray painting including cleaning, washing, preparation of old painted surfaces complete all as directed by Engineer-in-Charge for water coolers upto 150 capacity Make:- Asian / Berger / Jenson & Nicholson / Shalimar.
S&F automatic voltage stabilizer single phase 220 volt, 50 Hz of capacity 5 KVA complete all as specified and directed.
Supply and charging refrigeration gas R-134 for refrigrator/water cooler/deep freezer confirm with N2 pressure testing and flushing the system with liquid nytrozen, dehydration and evacuation the system all as specified and directed by Engr-in-charge Make: Mafron or euivalent .
RADHA ENTERPRISE
REMCO
SANKAR TRADERS
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .