Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 CrAccepted-Finance | ₹7.8 Cr | L1 | Accepted-Finance YES |
| 2 | L2₹8.0 Cr+₹20.4 L (2.63%)Accepted-Finance | ₹8.0 Cr+₹20.4 L (2.63%) | L2 | Accepted-Finance YES |
| 3 | L3₹8.8 Cr+₹1.1 Cr (13.9%)Accepted-Finance PLOT 1 SECTOR B POCKET 1 LOCAL SHOPPING COMPLEX VASANT KUNJ NEW DELHI 110070 | ₹8.8 Cr+₹1.1 Cr (13.9%) | L3 | Accepted-Finance YES |
| 4 | L4₹9.3 Cr+₹1.5 Cr (19.9%)Accepted-Finance PLOT NO HIG 7 CHUNVATI LANE GOPALGAN BALASORE 756001 | BALESHWAR | ODISHA | 756001 | ₹9.3 Cr+₹1.5 Cr (19.9%) | L4 | Accepted-Finance YES |
| 5 | L5₹9.6 Cr+₹1.8 Cr (23.6%)Accepted-Finance 306 MANISHA BUILDING 75 76 NEHRU PLACE NEW DELHI 110019 | ₹9.6 Cr+₹1.8 Cr (23.6%) | L5 | Accepted-Finance YES |
Tender Value
₹10.4 Cr
EMD Value
₹20.4 L
Closing Date
2 Mar 2020, 3:00 pmClosed
Shri P K Gupta Addl. CCE
Chief Construction Engineer (RandD) Central Rao Tula Ram Marg Behind Army HQ Camp Delhi Cantt 110 010
Provision of High Pulse Radiography Building at TBRL Range, Ramgarh
2020_DRDO_545047_1
CCE(RandD)C/TBRL/WKS(C)/19-20
Limited
Civil Works
Item Rate
365 days
Ramgarh, chandigarh
Please refer Tender documents.
5 documents required · 5 mandatory
₹3,000
Yes
Chief Construction Engineer (RandD) Central
₹20.4 L
Yes
9 Mar 2020
15 Feb 2020
3 Mar 2020
15 Feb 2020
2 Mar 2020
17 Feb 2020
Amount
SUBHEAD- I- SITE CLEARANCE
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
SUBHEAD - II EARTH WORK AND EXCAVATION
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m. All kinds of soil.
Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m. Ordinary rock
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m; disposed earth to be levelled and neatly dressed. All kinds of soil
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. Ordinary rock.
Extra for every additional lift of 1.5 m or part thereof for excavation in : (a) Ordinary or hard rock depth lift of 1.5M to 3Mtr
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth: consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m
Supplying and filling in plinth with River sand under floors including, watering, ramming consolidating and dressing complete..
Supply of approved earth obtained from out side MD land and filling in layers not exceeding 20cms thick, at all height and depths, in foundation pits, tranches, around structures and foundations, under floor and other places, including dressing and leveling, watering, compacting etc complete as per drawings, spcifications. ( The measurment for payment shall be made as per drawing after deductiing 5% for voids)
Supplying chemical emulsion in sealed containers including delivery as specified Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : (a) Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall & rodding etc. complete: With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
SUBHEAD- III PLAIN AND REINFORCED CEMENT CONCRETE WORK.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level
1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor block plain window sills, fillets etc. up to floor five level, excluding the cost of centering, shuttering and finishing : 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Providing, hoisting and fixing upto floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like including the cost of required centering, shuttering but excluding cost of reinforcement with 1:2:4 (1 Cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size).
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately).
All works upto plinth level.
All works above plinth level
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete,improve workability without impairing strength and durability as per direction of the Engineer-in-charge. All works above plinth level
All works upto plinth level.
All works above plinth level
Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable /recoverable separately. Providing M-30 grade concrete instead of M-25 grade BMC/ RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum)
Add / Deduct for using extra cement in the items of design mix over and above the specified cement content therein.
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete at all height & level.. Thermo-Mechanically Treated bars. Fe-500 D
Centering and shuttering including strutting, propping etc. and removal of form for:
Foundations, footings, bases of columns etc. for mass concrete.
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Suspended floors, roofs, landings, balconies and access platform.
Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Columns, Pillars, Piers, Abutments, Posts and Struts
Stairs (excluding landings) except spiral-staircases
Edges of slabs and breaks in floors and walls. Under 20 cm wide
Weather shade, Chajjas, corbels etc., including edges
Modular Formwork: Centering and shuttering including strutting propping etc and removal of form for slab, Beam, Column, wall ofany thickness, level and hight/Depth etc complete using modular form work of approved make etc and as directed by Engineer-in-Charge. The surface shall be exposed and no plaster shall be done over the RCC surface.
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentring at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured) Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)
Providing, fabricating & fixing in position at required locations to correct lines and levels, angles, inserts, pipe sleeves anchor bolts for columns, floors, machine foundations, crane brackets and all types of RCC, PCC and masonry including necessary welding, machining, grinding, threading etc. Rate shall include providing, making and positioning templates.
Anchor bolts
Plate inserts including hold fasts
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth
Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand).
Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : 0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra depth for circular type manhole 0.91m internal dia (at bottom) beyond 0.91 m to 1.67 m With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
SUBHEAD - IV BRICK MASONRY WORK .
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :: Cement mortar 1:6 (1 cement : 6 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand)
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size)
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification.
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil.
SUBHEAD - V : PLASTERING AND SURFACE TREATMENT
Providing of 6mm cement plaster of mix in all surface with cement mortar 1:3 (1 cement : 3 fine sand) at all levels
Providing of 12 mm cement plaster of mix in all surface with cement mortar 1:6 (1 cement : 6 fine sand) at all levels.
18mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge.
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections..
Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade in New work (two or more coats) over and including priming coat with cement primer
Finishing walls with Acrylic Smooth exterior paint of required shade in New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Applying priming coat :
With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)
With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade in Two or more coats on new work
Providing and fixing GI plaster mesh of nominal thickness 0.35 to 0.40 mm with zinc coating of 120 gms per sq m of approved make. (M/s. ARPITHA EXPORTS or equivalent) all as directed.
SUBHEAD - VI : FLOORING
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS:15622 (thickness to be specified by the manufacturer) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying double charged vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption's less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 60x60 cm
Providing and laying double charged vitrified floor tiles in different sizes (thickness to bespecified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), including routing the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm
Kota stone slab flooring over 20 mm average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Providing and laying Antistatic laminated false flooring with epoxy coated surface finish Panel is Made of good cold rolled steel sheet. Which are punched, Spotwelded, coated with epoxy powder. Inside the panel is filled with foamed cement. The steel sheet of the panel is stuck with fireproof HIGH PRESSURE LAMINATE(HPL) or conductive PVC tile Size 600mm X 600mm Thickness : 30/35mm .All steel construction with powder coated finish and cavity filled with cement slurry with complete steel structure nut bolt etc all complete as per direction of engineering incharge.
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing and laying vaccum dewatered flooring 100 - 200mm thick with reinforced cement conctere using nominal mix of 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate of 20mm nominal size) with reinforcement of 8mm dia at 150mm c/c both ways laid in alternate panels, channel form work including levelling, consolidation with vibrating table, withdrawal of excess water and finishing with compactor / power trowel sprinkling of extra cement, cutting grooves of size 4 x 15mm depth in early set concrete along the length of specified longitudinal and transverse joints (grooves spacing should not exceed 5m in either direction) using diamond point concrete saw, filling the grooves with approved joint filler polysulphide sealent etc., complete all as per specification.
Supply and application of epoxy rasin based static conductive/dissipative self levelling floor topping (nitoflor or equivalent) which shall provide an effective passage to the earth when applied over concrete or steel substrate. When measured for surface resistance in accordance with BS 2050, BS 6319, the static conductive topping, minimum flexural strength and minimum compressive strength shall be as per manufacturer's specifications. The system shall require the priming application of 2 coats of Nitroprime 25 or equivalent an epoxy based primer for concrete floor followed with a conductive / dissipative undercoat of nitoflor SL Undercoat or equivalent at a rate of 140gm/sqm or as per specified by the manufacture. Afterwards Nitoflor SL Conductive Topcoat or equivalent is poured on the primed surface and spread slowly and evenly to a thickness of 2mm using a serrated steel trowel. Immediately after spreading the floor shall be firmly rolled with a spike roller to release any entrapped air and level any slight trowel marks. Thickness of 2mm is must and should be checked again and a test shall be conducted to show that the SI conductive / dissipative flooring is working etc complete as directed by Engineer-in-Charge.
SUBHEAD -VII : DOOR WINDOW & WOOD / STEEL WORK
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile C Fixing with adjustable lugs with split end tail to each jamb
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Providing and fixing 2 mm thick wood finish M.S. sheet sliding-shutters, with frame and diagonal braces of 40x40x6 mm angle iron, 3 mm M.S. gusset plates at the junctions and corners, 25 mm dia pulley, 40x40x6 mm angle and T- iron guide at the top and bottom respectively, including applying a priming coat of approved steel primer
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured).
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
Providing and fixing bright finished brass 100 mm mortice latch and lock ISI marked with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles with necessary screws etc. complete (Best make of Approved Quality)
Providing and fixing of side hings or siliding precoated galvalume sheet door ( elctronic locking system) fabricated out of hollow M.S box section frame work and cladded bothside with liw rib(Around 20mm High) colour coated galvalume sheet of 0.5mm thickness (TCT -AZ-150,550mpa Alumminium zink alloy couting of 150gms per sqm total on both side ) with self tapping screws. All the frame work of the door will be painted 2 coat of epoxy Zinc phopsphate primer and finish paint on exposed surface shall be 2 or more coats in polyurethane aliphatic grade. All hardware roller hinhs etc shall be fabricated out of high grade steel with prior approval of engineer in charge before fabrication contractor are required to submitt the shop drawing and take approvel from engineer in charge.
Frame Work With out Sheet including All hardware
Percoated low rib galvalume sheet
Providing and Fixing in position M.S plates in two layers (16mm+16mm) as per approved design and drawing on RCC wall (Plane and curved Surfaces), All complete as per direction of Engineer in charge.
Providing and Fixing Threaded chemical anchor bolt 300mm long (M-24) (HILTI / Trutek) in RCC Wall /Column/Beam with 16mm MS Plates in two layers on curved / plane RCC Wall including drilling injecting chemical as per manufecture design & specification all complete as per direction by Engineer in charge.
Providing and Fixing Nuts (M-36) (HILTI / Trutek) for M-24 threaded anchor bolt for fixing 16mm MS Plates in two layers on curved / plane RCC Wall all complete as per specification and direction by Engineer in charge.
Providing and Fixing 1 mm thick Brass Plate protected the building with hilti anchor all nut bolt etc complet as per direction of engineer in charge
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) For fixed portion
Powder coated aluminium (minimum thickness of powder coating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately (a) Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): : With toughened glass panes of 5.5 mm thickness.
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300x16 mm
Providing and fixing aluminium tower bolts ISI marked anodised ( anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete: 200x10 mm
Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: 150 mm
Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. Twin rubber stopper
Providing and fixing of rubber nylon door buffer (dia of 40mm and 50mm long) on wall with rowl plug and screw.
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete. With Fixed to openings / wooden frames with rawl plugs (designation 10 No.) etc., all complete
Providing and fixing aluminium casement window fastener of required length for aluminium windows with necessary screws etc. complete. With Powder coated minimum thickness 50 micron aluminium.
SUBHEAD - VIII : ROOFING & WATER PROOFING:
Providing and fixing on wall face unplasticised Rigid Single socketed PVC rain water pipes conforming to IS : 13592 Type A, along with injection moulded fittings as required e.g., bends on any angle, sockets, junction, cowls, offsets, access pieces, including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion, providing and fixing MS stays & clamps and cutting & making good the holes in floors and walls wherever required etc. all complete. (For Rain water pipe).
110 mm diameter
160 mm diameter
Providing and fixing Armour Board (SIL–FIL) of Dawn colour between expansion joints, thickness built up using 10mm specifically extruded high performance sheet minimum density 30 kg per cum and compression strength 0.21 Kg./Sqm when tested as per ASTM D-3575 including using double sided adhesive SIL tape (manufactured by Supreme Industries Ltd. or equivalent) of 25x25x2 mm at four places per Sqm to the casted surface to form the expansion joint Armour Board (SIL – FIL) will become one side of the shuttering while the expansion joint is being created, including cost and conveyance of all materials, labour charges, sundries etc. complete as per drawings and as directed by Engineer-in-Charge. with 40 mm thick
Providing and laying 40 mm wide expansion joints to roof as per details shown in the drawing and filling the same with filler board & back up cord of approved make and top 40 x 20 mm gap from finished surface shall be sealed with THIOFLEX 600 two part, polysulphide sealant, manufactured by Fosroc to BS 4254 :1983 after priming using Primer 7E. The Cost shall inclusive of sealant material, labour for necessary surface preparation, and application and excluding of filler board & back up cord..
Providing and fixing sheet covering over expansion joints with iron screws as per design. With Aluminium fluted strips 3.15 mm thick and 200mm wide
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: Applying and grouting a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with water proofing compound conforming to IS:2645 and approved by Engineer - in- charge over the RCC slab including adjoining walls up to 300 mm height including cleaning the surface before treatment. Laying cement concrete using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer - in- charge over 20mm thick layer of cement mortar of mix 1:5 (1 cement: 5 coarse sand) admixed with water proofing compound conforming to IS2645 and approved by Engineer - in- charge to required slope and treating similarly the adjoining walls up to 300 mm height including rounding of junctions of walls and slabs.After two days of proper curing applying a second coat of cement slurry admixed with proprietary water proofing compound conforming to IS:2645 and approved by Engineer - in- charge .Finishing the surface with 20 mm thick joint less cement mortar of mix 1:4 (1 cement : 4 coarse sand) admixed with water proofing compound conforming to IS:2645 and approved by Engineer - in- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making of 300x300 mm square 3mm deep. The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge.
With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
Providing and laying in situ seven course water proofing treatment with APP (Atactic poly-propylene) modified Polymeric emberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 Kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702, 3rd and 5th layers of roofing membrane APP modified Polymeric membrane 1.5 mm thick of 2.25 Kg/sqm weight consisting of five layers prefabricated with centre core as 20 micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron HMHDPE film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately).
Laying brick tiles over mumty roofs, grouted With common burnt clay F.P.S. (non modular) brick tiles of class designation 10
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete..
SUBHEAD - IX SANITARY INSTALLATIONS
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required with W.C. pan with ISI marked white solid plastic seat and lid (Hindware cat. no 20011) or equivalent
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require with White vitreous china flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap, 15mm PVC connection pipe, waste coupling & 2 CI brackets
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
Providing and fixing C.P.brass bib cock of approved quality conforming to IS : 8931 with 15 mm nominal bore.(Jaquar model no. CON-037 kn/approved equivalent).
Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with fittings, standard size C.P. brass flush pipe, CP Angle stop cock along with Urinal Spreader, waste fitting,waste pipe, including cutting and making good the walls and floors wherever required :
Providing and fixing Salem Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required with Kitchen sink without drain board 610x510mm bowl depth 200 mm
Providing and fixing 100mm CP brass grating for trap
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. With Flexible pipe 32 mm dia
Providing and fixing 600x450 mm beveled edge mirror of superior glass of approved quality complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing soap dish of approved quality including fixing with C.P. brass screws etc. complete. (Jaquar CAT NO - ACN - 1131N)
Providing and fixing C.P. Brass towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality colour and make. With 600mm x 20mm size (Jaquar CAT NO - ACN - 1111N)
Providing and fixing C.P. brass toilet paper holder with concealed fitting arrangement of approved quality colour and make. (Jaquar Cat No. ACN - 1151N)
Providing and fixing Health faucet with concealed fitting arrangement of approved quality colour and make.
Providing and fixing approved type SS Double coat hooks with concealed type screws. Jaquar 1161 or equivalent approved make
Providing and fixing 15 mm nominal bor C.P. brass short body two way bib cock 15 mm nominal bore - Jaquar cat no-FLR-5041 N/equivalent .
SUBHEAD - X - INTERNAL WATER SUPPLY
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all (CPVC) plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This including jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of engineer in charge. .Internal work - Exposed on wall
25 mm dia nominal bore
32 mm dia nominal bore
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing this includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-charge. Concealed work, including cutting chases and making good the walls etc.
15 mm dia nominal bore
20 mm dia nominal bore
Providing and fixing brass stop cock of approved quality complete.
15 mm nominal bore
20 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
25 mm nominal bore.
32 mm nominal bore.
Providing and fixing C.P. bass angle valve for basin mixer and geyser points of approved quality conforming to I.S:8931 a) 15 mm nominal bore. With (a) 15 mm nominal bore
Providing and fixing unplasticised P.V.C connection pipe with PTMT Nuts coller and bush of approved quality and colour. With 15mm nominal bore with (a) 45cm length
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (a) 1000 ltr capacity
SUB HEAD - XI : INTERNAL ELECTRIFICATION WORK:
LIGHT POINTS: Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. a) Group - C
Wiring for group controlled (looped) light point / fan point / exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. a) Group - C
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.. a) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.. a) 4 X 10 sq.mm + 2 X 6 sq.mm earth wire
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 12 way (4 + 36), Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C series Miniature Circuit Breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc,as required. a) Single pole
Supplying and fixing following rating, four pole, 415 volts, MCB complete with connections, testing and commissioning etc. as required. 40 Amp
Supplying and fixing of following rating double pole (Single phase and neutral) 240 volts, residual current circuit breaker (RCCB), having a current sensivity current 30 miliampere in the existing MCB DB complete with connections, testing & commissioning etc. as required.. 40 Amp
Supply,installation, testing and commissioning of the following Light Fixture with lamp, Control Gear & All necessary accessories. Luminaries with all electrical accessories & it should be energy efficient, low loss, ortho cyclically wound open construction copper ballast, ignitor & power factor improvement capacitor or Electronics Ballast etc are prewired to the terminal block & mounted on are movable control gear module for ease of maintenance. All electrical connections of the control gear module with the rest of the luminaries should be click fix & require use of no tools. Mounting options should be for both lateral as well as pole top mounting. with Lamp Control Gear & Fixing Accessories.
20W LED Surface Type Light Fixture (Make: Regent Cat No. LED 5101-LED Tube-20w / Wipro cat no LL20-221-XXX-65AL1)
15W LED Ceiling Light Fixture surface Type Make: Wipro cat no LD80-131-XXX -60 SM, or equivalent)
18 W LED Ceiling Light Fixture Recessed Type (Make: Wipro cat no LD80-171-XXX-60-SM, or equivalent)
2'x2' LED Recessed Type Light Fixture (Make: Regent Cat No. LED 0820-Zen22SM-36w / Wipro cat no CRCO10R038HP57G1)
LED Highway Light (Make: Regent Cat No.LED 3664-Hogvik-150w / Wipro cat no LH14-192-XXX-57-G2)
1 x 10W LED Bulk Head Light Fixture Make: Regent Cat No.LED 9003-Bulkhead 10w / Wipro cat no LW07-141-XXX-57-XX)
9W LED Mirror Light Type (Make: Wipro cat no LL20-111-XXX-65NE3)
Supply, Installation, testing and commissioning of ceiling fan of 1200mm sweep ( white colour) with two module stepped type electronic fan regulator suitable for operation on 230/240V, 50Hz, single phase, AC Supply complete with double ball bearing motor, required down rod, capacitor, three MS blades etc complete. (5 Star Rating)
Supply, Installation & testing of 400mm wall bracket fan suitable for use on single phase, 230 volt, 50Hz AC supply complete with all accessories as required
Supply, Installation, testing and commissioning of 250 mm sweep decorative Fresh air fan with all accessories suitable for operation single phase 230 volt 50 cycle per second per sec. AC supply etc. as required. in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connection, testing, commissioning earthing etc. as required
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
SUB HEAD-XII : POWER WIRING
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and fixing suitable size PVC box with modular plate and cover in front on surface, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. a) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2x6 sq mm + 1x6 sq mm earth wire.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. a) 4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 12 way (4 + 36), Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C series Miniature Circuit Breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc,as required. a) Single pole
Supplying and fixing following rating, four pole, 415 volts, MCB complete with connections, testing and commissioning etc. as required. 63 Amp
Supplying and fixing of following rating double pole (Single phase and neutral) 240 volts, residual current circuit breaker (RCCB), having a current sensivity current 30 miliampere in the existing MCB DB complete with connections, testing & commissioning etc. as required.. 63 Amp
Supplying and fixing of 150 MM wide X 40MM deep GP raceway Fabricated GP sheet raceway for electrical and LV wiring including neoprene gasket in joint, cutting the floor & jaming the race way / hanging in ceiling supporting arrengement etc all complete as approved by Engineer-in-charge
Supplying and fixing of 200 MM wide X 50 MM deep Juction Box made out GP sheet raceway for electrical and LV wiring including neoprene gasket in joint, cutting the floor & jaming the junction box / hanging in ceiling supporting arrengement etc all complete as approved by Engineer-in-charge
Supply, installation, Testing and Commissioning of 3 phase and Neutral 415V 4 wire Free Standing Floor mounted indoor MV panel made out of 14 SWG MS sheet after seven tank process and painting with Epoxy powder coating. The panel shall consist of suitable rating TPN Aluminium bus bar (at the rating of 0.8A/Sq.mm) supported with DMC/ SMC barriers and color coded with Heat shrinkable sleeves. The Metering shall be provided as specified. The panel shall have short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below. The panel shall be got fabricated from manufacturer with CPRI Test certificate only. The PCC shall have at least two spare cubicles of the maximum rating. The size of all Panel Mounting Meters shall be 96X96mm. The Panels shall be mounted on U channels including supply and fixing of the same. Make :Schneider Electric or Equivalent.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 A, 25KA,FP Moulded case circuit breaker with operating handle.
Supplying and fixing of metal one way sheet steel enclosure for FP MCCB Suitable for 100A complete with connections, testing and commissioning etc. as required.
SUB HEAD - XIII : UPS WIRING:
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
Supplying and fixing suitable size PVC box with modular plate and cover in front on surface including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). (For UPS Supply)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. a) 2 X 2.5 sq.mm +1 X 2.5 sq.mm Earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. a) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. a) 2 X 16 sq.mm + 1 X 6 sq.mm earth wire
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a) 16 way , Double door.
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C series Miniature Circuit Breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc,as required. a) Single pole
Supplying and fixing following rating, double pole, 240 volts, MCB complete with connections, testing and commissioning etc. as required. 63 Amp
Supplying and fixing of following rating double pole (Single phase and neutral) 240 volts, residual current circuit breaker (RCCB), having a current sensivity current 30 miliampere in the existing MCB DB complete with connections, testing & commissioning etc. as required.. 63 Amp
Supply, installation, testing & commissioing of 6.0KVA UPS at 0.99 input power factor as per specification given in the document with following broad features. THD(i) shall be less than 3% in the entire loading range. Input power factor shall be more than 0.95. from 25% to 100% load. UPS shall carry design output at 40 deg.Shall have soft start and hold of for incoming supply. Invertor capability to supply 150% load for 5 sec. Single Phase Input and Single Phase Output. (Input - 180V - 240V, Single Phase, 2 wire. / Output - 200Volt, Single Phase, 2 Wire.) Shall not allow deep discharge of the battery and shall not go to 10.5 volts in case of 12 volt cells.Battery shall be external type with rack and suitable for 30 minute backup on 100% load.
SUB HEAD - XIV : TELEPHONE / TV / LAN CONDUITING:
Supplying and fixing of following sizes of steel conduit alonwith the accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. (for Telephones, TV and Data) a) 25 mm
Supplying and fixing of following sizes of steel conduit alonwith the accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. (for Telephones, TV and Data). a) 32 mm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. a) Telephone socket outlet
Supply and fixing of Data outlet (RJ45) with anodised GI box with front plate etc. complete as required
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. a) TV antenna socket outlet
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. a) 1 or 2 Module (75 mmX75 mm)
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. a) 2 Pair
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. a) 20 Pair
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Supply and installation of following size Krone connectors in MS box complete as required. a) 20 Pair
SUB HEAD - XV : SPECIAL EARTHING:
Maintenance Free Earting : - Supply & Fixing of Low carbon high tensile Copper Bonded Ground rods having min 250 micron of copper coating . The diameter of Rod should be 17.2 mm with the length of 3000 mm . The ground rod should be UL approved and tested from CPRI. The earthing include 400 mm square C.I. frame with hinged cover, masonry housing including excavation and back filling. The Rod should be surrounded with Earth Enhance compound of 30 Kg tested as per IEC 62561-2 for the rod & IEC 62561 -7 for compound. (borh are from same manufacturer) Exothermic welding shall be used for connection between main electrode (copper bonded rod) and copper strip of size 50 x 5 mm. Further GI strips as down conductor shall be connected to Copper strips. (i.e. stainless steel)
Providing and fixing of 17.2 mm Dia CCS Horizontal conductor used for making Earth Mat wth exothemic X-joint, T-joint, L-Joint of 17.2 mm dia Copper bounded road laying 600mm below the ground.
Providing and fixing of 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing of earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.
SUB HEAD-XVI : LIGHTNING PROTECTION
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required.(For horizontal run)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required. (For vertical run)
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 Nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.
Maintenance Free Earting : - Supply & Fixing of Low carbon high tensile Copper Bonded Ground rods having min 250 micron of copper coating . The diameter of Rod should be 19.2 mm with the length of 3000 mm . The ground rod should be UL approved and tested from CPRI. The earthing include 400 mm square C.I. frame with hinged cover, masonry housing including excavation and back filling. The Rod should be surrounded with Earth Enhance compound of 25 Kg tested as per IEC 62561-2 for the rod & IEC 62561 -7 for compound. (borh are from same manufacturer) Exothermic welding shall be used for connection between main electrode (copper bonded rod) and copper strip of size 32 x 6 mm. Further GI strips as down conductor (with test joint) shall be connected to Copper strips by means of special bi-matellic connector (i.e. stainless steel)
SUB HEAD-XVII: FIRE ALARM SYSTEM
Supplying, installation, testing & commissioning of addressable beam detector with short circuit isolator (inbuilt or seperate) complete with emitter and receiver including connections with remote test features etc complete as required..
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector acclimate type sensetive level (0.524%) OVS/ft. complete with mounting base complete as required.
Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required.
Supplying, installation, testing & commissioning of addressable manual call point complete as required.
Supplying, installation, testing & commissioning of addressable fire control module complete as required.
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. (75 DBA @3 mtr. & 75CD flashing)
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.
Supplying, installation, testing & commissioning of fault isolator complete with base as required..
Supply, installation, testing and commissioning of addressable monitor module complete as per specification.
Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required.
Supply, fixing and installation of fire exit signage's self illuminating light fixtures displaying exit with an arrow towards the exit door.
SUB HEAD - XVIII : ACCESS CONTROL SYSTEM:
Supplying,Installation, Testing and Commissioning of 4-Reader Accesscontroller with TCP/IP Communication Port,Built-in Compact Flash Card, LCD display for displaying information,including 12 Volts DC / 5Amps power supply unit complete with batterycharging unit and suitable aestheticenclosure with intrigated of fire alarm system complete with all accessories as required.
Supplying, Installation, Testing and Commissioning of Biometric based SmartCard Reader (Finger print and smart card)with LCDdisplay and Pinpad. Read Range of 3 Inches. complete with all accessories asrequired
Supplying, Installation, Testing and Commissioning of Smart Card Reader. Read Range of 3 Inches. complete with all accessories as required.
Supply of Standard CreditCard Size Smart Cards withWhite Glossy Finish as per the technical specifications complete with allaccessories as required
Supplying, Installation, Testing and Commissioning of Web-BasedAccess Management Software with Graphical representation of Floor Plans,Multi-Operator Login, Multi-Level Operation, Alarm Management, Reporting,time and attendance Software with user defined generic reporting, Visitormanagement for 24 Doors and 1000 CardHolders /persons etc. complete with all accessories as required
Supply and Laying of of 8 Core x 0.75 sq mm multistrand, copper , shielded armoured Cable (between the card readers & theaccess controllers) complete with all accessories as required.
Supplying, Installation, Testing and Commissioning of electromagnetic Single door lock complete with mounting arrangment, internal wiringetc. and all accessories as required.
Supplying, Installation, Testing and Commissioning of electromagnetic Double door lock complete with mounting arrangment, internal wiringetc. with all accessories as required
Supplying, Installation, Testing and Commissioning of exit pushbutton complete with all accessories as required.
Supplying, Installation, Testing and Commissioning of high gradeworkstation machine for access control SW applcaition with i5 processor, 8 GBRAM , 21 " LED monitor and 1TB hdd , Licensed Microsoft Windows 7 andother operating software with 600VA UPS complete with all accessories asrequired
SUBHEAD- XIX - EXTERNAL WATER SUPPLY,
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work
32 mm nominal outer dia Pipes
50 mm nominal outer dia Pipes
80 mm nominal outer dia Pipes
Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality
32 mm nominal outer dia Pipes
50 mm nominal outer dia Pipes
80 mm nominal outer dia Pipes
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
32 mm nominal
50 mm nominal
80 mm nominal
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design :With flyash (non modular) bricks of class designation 7.5
Providing and fixing gun metal non- return valve of approved quality (screwed end) :
32 mm nominal bore.
50 mm nominal bore.
80 mm nominal bore.
Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m : Ordinary Rock in Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia
Supply of Self Contained Drinking water cooler with refrigent R-22 Cooling capacity ltr/Hrs 4, Storage type, Storage capacity 80 Ltr alongwith Aqua Guard for water purification, voltage stabilizer of 5KVA & all fixing hardware etc., complete
SUBHEAD -XX : ROAD & HARDSTANDING, AREA DEVELOPMENT
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared..
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m; disposed earth to be levelled and neatly dressed. All kinds of soil
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level (a) 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres.
Construction of granular sub-base by providing close graded Material conforming to pecifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30
Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge.
Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately). Note:- Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately. (a) Cement concrete prepared with batch mixing machine
Providing & laying 300 mm micron thick PVC sheet over the base course surface as per direction of engineer in charge.
Providing and fixing in position pre-moulded joint filler in expansion joints.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge)
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete:
300 mm dia. R.C.C. pipe
600 mm dia. R.C.C. pipe
900 mm dia. R.C.C. pipe
SUBHEAD -XXI SEWERAGE DISPOSAL
Excavating trenches of required width for pipe, cables etc including excavation for sockets ,& dressing of sides ,ramming of bottoms ,depth upto 1.5m including getting out the excavated soil,& then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming ,watering, etc and disposing of surplus excavated soil as directed, within lead of 50m. All kinds of soil Pipes, cables etc exceeding 80 mm dia but not exceeding 300 mm dia.
Providing and fixing SWR / uPVC pipe 6 Kg/Sqcm (IS:4985-2000) including injection moulded fittings (plain or door) wherever required e.g., bends on any angle, sockets, junction, cowls, offsets, access pieces, jointing with rubber ring/solvent cement joints including covering with cement concrete 1:2:4, cutting and making good the holes in floors and walls wherever required etc. all complete. (for Soil and Waste Drainage pipe).
100 mm diameter
150 mm diameter
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete: (a) 150 mm diameter
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipe including bed concrete as per standard design: (a) 150 mm diameter
Providing and fixing square mouth SW gully trap class SP-1 complete with CI grating brick masonry chamber and water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg. as per standard design. 150x100mm size P type with common brunt clay F.P.S. (non modular) bricks of class designation 7.5.
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common brunt clay F.P.S. (non modular) bricks of class desigation 7.5
Construction brick masonry manhole in cement mortar 1:4 (1 cement : 4 coarse sand) with RCC top slab with 1:2:4 mix (1 cement : 2 coarse sand 4 graded stone aggregate 20mm nominal size) foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design. (a) Inside size 90 x 80 cm and 45 cm deep including CI cover with frame(light duty) 410x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg). With common brunt clay F.P.S. (non modular) bricks of class desigation 7.5
Extra for depth for manholes for Size 90x80cm With common brunt clay F.P.S. (non modular) bricks of class desigation 7.5
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter vent pipe with cowl, 1.8 m long complete as per standard design. With common brunt clay F.P.S. bricks of class designation 7.5
Supply, lowering & installation of RCC readymade hume pipe septic tank of approved make at suitable location as directed including excavation, back filling, sewer line connections at inlet & outlet, inspection chambers, etc. complete as standard design and as directed. 50 User
SUBHEAD -XXII : ARBORICULTURE
Tree plantation Digging pits in all type of soil and refilling the same with the good earth(excavated/imported) & manure (organic manure/ cow dung/ sludge in the ratio-of 3:1 (03 part of stacked volume of good earth in needed additionally to be paid separately after reduction of 20% of stacked volume of good earth & 8% stacked volume of manure AVENUE / FLOWERING TREES PT SIZE- (a) 1m x 1m x 1m (LxBxD)
Maintenance of tree sapling, after plantation for 30 days or more as minimum guarantee period , for well establishment of tree sapling. Stacking to be continued till tree sapling attains the stem strength. Replacemet of sapling casualties immediately
Ground Cover Digging of ground cover marked area upto a deapth of 30 cms in all type of soils. Refilling the same with (excavated / dupplied ) good earth mixed with manure (organic/cowdung sludge) in the ratio of 8:1 (08 part of stacked volume of good earth & 01 part of manure). Cost of manure/ sludge and good earth in nedeed additionally to be paid saparately , after reduction of 20% in good earth & 8% stacked volume granules @100 gms/ sq mts. Flooding with water this entire area. Rough & fine dressing of ground cover bed area and removel of weeds & unwanted vegetation & its disposal
Supply and plantation of approved / desired ground cover plant varieties well established fully grown, disease free and good foliage plantation density should be @36 ground cover plants/Square meter, or less as desired or dicided by site incharge replacement pf sapling casualites immediatly.
Hedge plantation Digging tranches of approved/desired size of LxW (45-50 cms) x (30-60 cms) in all type of soil. Refilling the tranches with good earth (excavated / imported ) mixed with manure ( cow dung/ sludge/dump) in the ratio of 5:1 (05 part of stacked volume of good earth and 01 part of manure). Cost of manure /sludge and good earth if needed additionally to be paid separately, after reduction of 20% for good earth & 8% in stackes volume of manure. For termite treatment add Thimet10G granules @100 gms/ running mts. Flooding the tranch with water then rough & fine dressing of tranched area including removel of undesirable weeds 7 vegetation .
Lawn plantation preparation of ground by trenching in all typs of soil upto a depth of 30 cm including removal and stacking of serviceable material than disposing the surplus soil with all lead & lift, by spreading and leveling neatly making up the trenched area well leveled by filling with additionally supplied earth (if need )
Shrubs: Digging of pits of size 0.60x0.60x0.60m and refilling with good agriculture soil and well decomposed cattle manure in 3:1 ratio. Supply and planting of approved Shurbs species of healthy grownup saplings with good root system. Saplings should be of minimum 2 ft height from ground level after plantation. Maintenance includes, regular watering, de-weeding, loosening of soil fortnight, manuring with cattle manure and fertilizer, training, pruning, staking and spraying of insecticide and fungicide, including initial maintenance of one month
Flower Beds: Digging upto 0.10m refilling with good soil and cattle manure in 3:1 ratio. Preparation of beds supply and planting of of healthy grown up plant material. Maintenance includes regular watering, de-weeding, manuring with manure and fertilizer.pruning, shaping and spraying of insecticide and fungicide including initial maintenance of one month.
Agriculture Soil: Supply of good soil for filling suitable for any type of plantation at the site including leveling, spreading, refilling of pits.
Potted Plants: Supply and maintaining the Indoor and Outdoor potted plants in a good healthy and disease free condition of various varieties and in different type of pots.
Brick Edging Edging with bricks (Class-1) laid in pcc (1:2:4) lengthwise, including required excavation, refilling consolidating with and packing spreadeing surplus earth neatly with all lead and lifts.
SUB HEAD - XXIII: EXTERNAL POWER SUPPLY:
Supply and installation of 990Ltrs capacity Fuel tank made out of MS sheet with Inlet/ Outlet connecting pipes, plugs, Drain valve from DG sets to tank and Scale with level monitoring
Supply and Fixing of MS Exhaust Pipe of 125mm dia cladded with 50mm thick Glasswool insulation covered with 24SWG Aluminium sheet
Supply and installation of double pole structure with 2 nos 9 metre long (1.50mtr below Ground) MS swaged pole (410 SP25) with 3.50 x 350 x 10mm MS base plate, earthing studs, including 1:3:6 foundation PCC Pedestal complete with painting with black bitumin paint inside the coping for embedded portion and two coats of Zinc chromate primer and two coats of Aluminium paint externally the length above the ground. consisting of 1set of 11KV 400A Triple pole manually gang operated complete with all standard accessories, support insulators and provided with 1set of 9KV 5KA Lightning arrestors, necessary channels, accessories, Pin/Strain type insulators, Stay sets, DO Fuse and anti climbing device, danger notice board, jumpers for connecting to euipment and all accessories like bolts, nuts etc. complete as required..
Design, manufacture, supply, installation, testing and commissioning of 250 KVA, 11 KV /0.415 KV, 3 phase, 4.5 % impedance, 50 Hz delta/star-11 connected, outdoor type, copper wound transformer, oil immersed ONAN cooled, complete with all fittings such as oil conservator, silica gel breather, thermometer, explosion vent with off Load Tap changing arrangement on HV side with Tapping for variations of high voltage from (+) 5% to (-) 10% in steps of 2.5% each, bi-directional roller, diagrams & rating plate, Oil temperature indicator, & Winding temperature indicator, weather proof Marshalling Box, lifting lugs, first filling of oil, weather proof H.T/L.T cable box etc. complete as per specification. All relays, contacts & CT terminals to be wired upto marshalling box. The Transformer losses should confirm to IS - 1180 Part-1 (2014) with energy efficiency level 2 [0.98 KW at 50% load & 2.93 KW at 100% load shall not exceeds by 5.0% (@ 11 KV) of the maximum total loss values. a) 250KVA
Supply, Receiving, Unloading, Shifting, Installation, Testing & Commissioning of 250 KVA Indoor type, 340V to 460V, 3-phase, 50 Hz, IGBT PWM natural air cooled type, LT Automatic electronic Voltage Staibilizer balanced input supply and unbalanced output load, copper wound complete with following fittings and as required for trouble free operation Input Voltage - 340 to 460 Volts, 3 Ph., 50 Hz. Output Voltage - 400V±1%, 3 Ph., 50 Hz.
Design, Manufacturing, Supply, Receiving, Unloading, Shifting, Installation, Testing & commissioning of Main L.T. Panel, this will be floor mounted, free standing, compartmentalized, indoor duty, dust proof, vermin proof, front operated, electrical panel fabricated, painted and manufactured exactly as per specifications laid in this document and will be complete with the main and auxiliary bus bars, interconnection, earth terminals, earth bus and will be powdered coated finished. All the busbar joint shall be protected by clip on type sleeve. The control panel shall use all draw out 3 position withdrawn type breakers suitable for 415 V AC, 3 phase, 50 Hz, 4 wire supply system and will have fault level of 25 KA or as required as per consultant approval. The panel will be made as per detailed specifications and drawings forming part of this document.The current density of main bus bar & drooper bus bar up to 1000 Amp shall be minimum 1.00 sq mm / amp & for 1250 / 1600 amp shall be minimum 1.30 sq.mm / amp.& for 2000 / 2500 / 3200 amp shall be minimum 1.60 sq.mm / amp
Each Incoming / Outgoing Air Circuit Breaker Breaker shall have microprocessor release with adjustable over current, short circuit & earth fault protection with instantaneous as mentioned in specification. The Panel will be made as per detailed specifications & drawings forming part of this document. Fault level of panel shall be 50 KA. Each Bus Coupler Air Circuit Breaker shall be with inbuilt U/V release. The Panel will be made as per detailed specifications & drawings forming part of this document. Fault level of panel shall be 50 KA. Each Outgoing MCCB shall have thermal release with adjustable over current, short circuit & eartg fault protection (Inbuilt / External module) up to 250 Amp and above shall have microprocessor release with adustable overload, short circuit & earth fault protection. (Ics shall be 25 KA). Make : Schneider Electic or equivalent
INCOMING 2 Nos. 630 Amp FP Electrically operated horizontal drawout type Air Circuit Breaker. BUSBARS 600 Amp TPN busbars of aluminium alloy as per SLD. OUTGOING 01 Nos 200 Amp FP Moulded Case Circuit Breaker(25KA) 01 Nos 160 Amp FP Moulded Case Circuit Breaker(25KA) 05 Nos 100 Amp FP Moulded Case Circuit Breaker(25KA) 06 Nos 63 Amp FP Moulded Case Circuit Breaker(25KA) 02 Nos 40 Amp FP Moulded Case Circuit Breaker(25KA)
APFC PANEL - 100 KVAR Incoming : 1 No. Digital Multifunction Meter with CT's. Metering : 1 Sets of phase indicating lights (RYB) with protection MCB's. 1 Sets breaker 'ON' & 'OFF' indicating lamp. 8 Step Automatic Power Factor Correction relay (APFC relay). BUSBARS 200 Amp TPN busbars of aluminium alloy as per SLD. OUTGOING:- 03 Nos.63 Amp TP MCCB (25 KA) with capacitor duty contactor (one for each 25KVAR capacitor unit). 02 Nos.32 Amp TP MCCB (25 KA) capacitor duty contactor (one for each 10KVAR capacitor unit). 01 Nos.16 Amp TP MCCB (25 KA) capacitor duty contactor (one for each 5KVAR capacitor unit).
Maintenance Free Earthing : - Supply of Low carbon high tensile Copper Bonded Ground rods having min 250 micron of copper coating . The diameter of Rod should be 17.2 mm with the length of 3000 mm . The ground rod should be UL approved and tested from CPRI. The earthing include 400 mm square C.I. frame with hinged cover, masonry housing including excavation and back filling. The Rod should be surrounded with Earth Enhance compound of 30 Kg Earth Enhancement Compound low resistivity (0.12 ohm meter ) tested as per IEC 62561-2 for the rod & IEC 62561 -7 for compound. (borh are from same manufacturer) Exothermic welding shall be used for connection between main electrode (copper bonded rod) and copper strip of size 50 x 5 mm. Further GI strips from equipments shall be connected to Copper strips by means of special bi-matellic connector (i.e. stainless steel)
Maintenance Free Earthing : - Supply of Low carbon high tensile Copper Bonded Ground rods having min 250 micron of copper coating . The diameter of Rod should be 17.2 mm with the length of 3000 mm . The ground rod should be UL approved and tested from CPRI. The earthing include 400 mm square C.I. frame with hinged cover, masonry housing including excavation and back filling. The Rod should be surrounded with Earth Enhance compound of 30 Kg Earth Enhancement Compound low resistivity (0.12 ohm meter ) tested as per IEC 62561-2 for the rod & IEC 62561 -7 for compound.(borh are from same manufacturer) Exothermic welding shall be used for connection between main electrode (copper bonded rod) and copper strip of size 50 x 5 mm.
Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 50 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Supply and laying of 11KV grade Rubber Mats as per IS 15652 of size1000mm x 2000mm
Supply and fixing of 4 nos fire bucket painted red and duly filled with MS sand complete as required. conforming to IS:2546-1974.
Supplying and fixing of shock restoration chart written in English and Hindi duly framed in glass as required.
Supplying and fixing carbon dioxide fire extinguisher type 4.5 Kg. capacity of approved make wall mounting bracket as required conforming to IS;2878/1976.
Supplying of first aid box as approved complete with standard kit as prescribed by Indian Red Cross.
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Supply of Hand Gloves -11KV grade
Supplying of XLPE insulated and PVC sheathed 1100V armoured copper conductor control cable as required. a) 4 x 1.5 Sqmm
Supplying of XLPE insulated and PVC sheathed 1100V armoured copper conductor control cable as required. a) 10 x 1.5 Sqmm
Supplying of XLPE insulated and PVC sheathed 1100V armoured copper conductor control cable as required. a) 14 x 1.5 Sqmm
Supplying of following size aluminium conductor XLPE 11 KV (E) cable complete as required. The cable shall conform to IS : 7098/ Part II a) 3C x 240 Sqmm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. a) Above 120 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. a) Above 120 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required. a) Above 120 sq. mm and upto 400 sq. mm
Supplying and making indoor cable end jointing with cast resin compound, including lugs and other jointing materials, for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : a) 3C x 240 Sqmm
Supplying of XLPE insulated, PVC sheathed 1.1 KV grade aluminium conductor armoured power cable as per IS : 7098 of following sizes:
3.5 core 185 sq. mm.
3.5 core 70 sq. mm.
3.5 core 35 sq. mm.
4 core 16 sq. mm.
4 core 10 sq. mm.
2 core 16 sq. mm.
2 core 6 sq. mm.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Upto 35 sq. mm.
Above 35 sq. mm and upto 95 sq. mm.
Above 95 sq. mm and upto 185 sq. mm.
Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.
Upto 35 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3.5 core 185 sq. mm.
3.5 core 70 sq. mm.
3.5 core 35 sq. mm.
4 core 16 sq. mm.
4 core 10 sq. mm.
2 core 16 sq. mm.
2 core 6 sq. mm
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. a) 100mm dia
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. a) 150 mm dia
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. a) 300 mm dia
SUB HEAD - XXIV : AREA LIGHTING:
Supply, erection, testing and commissioning of individual 3mtr long (600mm below Ground) 65mm dia Class B GI pole, 750mm out reach single arm complete with base plate FRP terminal box, wiring from terminal to the fixture with 3core 2.5sq.mm copper conductor cable, MCB control and 2nos of 40mm dia Class B GI pipe for incoming and outgoing cable etc including PCC foundation, pedestal and Supply and installation of 40W LED Lamp Post top Lantern fixture Integral type with Lamp and Controlgear/driver etc complete as required. (Make : Wipro cat no LP02-501-XXX-57-XX / 57/ -CL Philips cat no BDS670 GRN40)
Supply, erection, testing and commissioning of steel stepped and swaged tubler poles of 6mtr. Long (410 SP25) (1.5mtr below Ground) with base plate, earthing studs,1.5Mtr out reach single arm, FRP terminal box, 2nos 40mm dia class B GI Pipe, 0.75mtr. Long each for incoming and outgoings cables, including excavation in all types of soil, PCC 1:2:4, PCC Pedestal complete with painting with black bitumin paint inside the coping for embedded portion and two coats of Zinc chromate primer and two coats of Aluminium paint externally for length above the ground. The pole shall be with FRP Junction box consisting of 10A SP MCB. The wiring from Junction box to Light fixture shall be carried out with 3core 2.5sq.mm Copper conductor cable. The pole shall be fixed with 60W LED Lamp with fixture including supply of Condrolgear / driver and lamp etc complete as required. (Make: Wipro cat no LR02-671-XXX-57-G2 / Philips cat no BRP410)
Providing of Spiral coil earthing with 8 SWG GI wire including spreading of salt and charcoal as per IS 3043/87 with latest amendments complete as required.
SUBHEAD -XXV : EOT CRANE
Design, Manufacturing, Supplying, Erection, Testing & commissioning of double girder, Crab type EOT crane (Non Flame proof) 5 T Capacity, conforming to the standards given in IS: and other relevant IS standards of the latest revisions etc. all complete with all taxes, duties and other charges such as transportation to site, loading and unloading at stores/building, where to be installed etc., movement of material to work spot including the cost paint as required. Duty: Indoor, Span:6m Bay length: 13.5m, Lift: 9.0m
Supplying, Erection, Testing & Commissioning of for drag chain type of current collection system complete with drag chain with vertical separators, mounting brackets with tie wrap plates, support plates, trough with glide bar including mounting kit, along with cable from switch and with all necessary fixtures.
Supplying Erection, Testing & Commissioning of Gantry Rails section 60LB of prime material in length of 10m and above complete with mounting arrangement and fixing hardware etc. complete over the bay length to match the span of the crane within the permissible accuracy levels for span in height variation as per the QA plan.
SUBHEAD -XXVI : FURNITURE WORK
Providing and Supply Single Seater sofa Parto of having size 1340mm Width x Depth 870mm x Height 730mm, Seat Height 395mm. Providing comfort and convenience to its user. Its Comoactness ensures efficient space management and manages to accommodate everyone quit comfortably with its rubber wood fascia and contour armrests the parto sofa set is the perfect embodiment of elegance and class.
Providing and Supplying Three seater sofa Parto of having size 1750mm Width x Depth 870mm x Height 730mm, Seat Height 395mm. Providing comfort and convenience to its user. Its comoactness ensures efficient space management and manages to accommodate everyone quite comfortably with its rubber wood fascia and contour armrests the parto sofa set is the perfect embodiment of elegance and class.
Supply of executive office table of size 1800 x 900 x 750 (Front of top should be curved) made out of 19mm thick commercial board for top and sides with 03 Nos. drawer and foot rest made up of min 25mm thick teak wood. Top and external sides to be covered with 3mm thick vinear of teak finish. Edges of 19mm thick ply to be pasted with 4mm thick teak wood strip as required including melamine polish etc. all complete. (Make Godrej impress interio with ERU and pedestal.)
Supply of officer table of size 1500 x 900 750 (Front of top should be curved)made out of 19mm thick commercial board for top and sides with 03 Nos. drawer and foot rest made up of min 25mm thick teak wood. Top to be covered with 3mm thick vinear of teak finish. Edges of 19mm thick ply to be pasted with 4mm thick teak wood strip as required including melamine polish etc. all complete. (Make Godrej executive table Aristo 1650 with ERU and pedestal.)
Supply of computer table of size 1000 x 600 x 750 made out of 19mm thick commercial board for top and sides with 01 Nos. drawer and foot rest made up of min 25mm thick teak wood. Top to be covered with 1mm thick laminate or approved shade. Table has provision of keyboard tray and printer option as per specification.
Supply of Centre Table made out of 70 x 25mm teakwood frame work & 45 x 45mm teak wood moulded legs, top to have 19mm thick laminated top, edges to have 30 x 30mm teak wood moulding finished with melamine polish all complete. Centre Table of size 1050 x 525 x400 (Make Godrej Victoria.)
Supply of Modular type U shaped Conference Table of standard height and width etc for 14 persons made out of 19mm thick commercial board with 4mm teak veneer on top and 19mm thick commercial board tapered foot rest with provision for shelf for each person and provision for wiring etc for fitting of PA system etc. (Godrej Senate)
Supply of Corner Table made out of 70 x 25mm teak wood frame work & 45 x 45 teak wood moulded legs, top to have 19mm thick laminated top, edges to have 30 x 30mm teak wood moulding finished with melamine polish all complete. (Make Godrej Edward Interio) Corner Table of size 610 x 610 x 430
Supply of magnetic display cut writing board of size 900 x 1200 with suitable tripd of reputed make
Supply of magnetic display cum writing board of good quality Hard, Scratch and stain resistance non reflective surface, as approved by the engineer-in-charge of size 2400 x 1200 without tripod. (Ceramic steel Magnetic)
Supply of tripod for display boards etc.
Supply of high back executive revolving & tilting chair with hydraulic jack gas lift and arm and of size 760 x 760 x 1080mm PU cushion made out of powder coated/hot painted MS Frame of standard size with PU cushion 50mm thick for back with 5 Nos wheel castors covered with fabric of approved quality & shade etc. all complete. Make Godrej Interior Motion high Back Executive Chair or equivalent item of standard make.
Supply of high back non executive revolving & tilting chair with hydraulic jack gas lift and arms and of size 550 x 550 x 900mm PU cushion made out of powder coated MS Frame with PU cushion 50mm thick for back with 5 Nos wheel castors covered withfabric of approved quality & shade etc. all complete of godrej make or equvalent item of standard make.
Supply of computer chair revolving & tilting with hydraulic jack gas lift and arms rest and size 450 x 450 x 900mm PU cushion made out of powder coated MS Frame with PU cushion 50mm thick for back with 5 Nos wheel castors covered with fabric of approved quality & shade etc. all complete. Make: Godrej or equivalent.
Supply of Visitor Chair revolving & tilting with hydraulic jack gas lift and arms rest and size 450 x 450 x 900mm PU cushion made out of powder coated MS Frame with PU cushion 50mm thick for back with 5 Nos wheel castors covered with fabric of approved quality & shade etc. all complete. Make: Godrej or equivalent.
Supply of standard steel almirah for office purposes made up of M.S sheet of 1mm thick for side and back and 1.24mm thickness for doors MS sheet conforming to commercial quality CR-1. Grade 340 of IS 513:2008 (reaffirmed 2013) (Fifth Revision) Amdt. No.1 and door of thickness 3mm thick polycarbonate sheet fixed in the ms sheet frame. Size of almirah to be 2000 (without pedestal) x 1023mm x 430mm with adjustable shelves arrangement and lock arrangement. Make Godrej or equivalent.
Supply of standard steel almirah for office purposes made up of M.S sheet of 1mm thick for side and back and 1.24mm thickness for doors; MS sheet conforming to commercial quality CR-1, Grade 340 of IS 513:2008 (reaffirmed 2013) (Fifth Revision) Amdt. No.1 and door of thickness 3mm thick polycarbonate sheet fixed in the ms sheet frame. Size of almirah to be 1300 (without pedestal) x 1000mm x 360mm with adjustable shelves arrangement and lock arrangement. Make Godrej or equivalent
SUBHEAD -XXVII : AIR CONDITIONING WORK
VRV/VRFSystem: Supply, Installation, testing and commissioning of AIR COOLED & INVERTER BASED VARIABLE REFRIGERANT VOLUME / VARIABLE REFRIGERANT FLOW MODULAR TYPE AIR CONDITIONING SYSTEM with R410A suitable for 415 ± 10% , 50 Hz. The unit shall consist of indoor units and external condensing units and other accessaries as listed below complete in all respects as under
Outdoor Unit SITC Modular type outdoor units equipped with highly efficient inverter type scroll compressor(s) with special precoated heat exchanger, low noise condenser fan housed in compact housing duly powder coated. Outdoor units shall have both cooling & heat pump mode, and environmet friendly refrigerant R-410A.The C.O.P shall be confirmed by vendor at full and part load at 41 deg C ambient temperature..Complete with M.S mounting stand of approved design for outdoor unit.Nitogen Flushing before gas charging.Pressure testing should be done after installation.Anti corrosive coating should be done at site.
20 HP (Actual) at 41 Deg C
Indoor Units: Supply,Installation, testing and commissioning of both interconnected with copper refrigerant & drain pipe of required length, insulation, full charge of refrigerant gas and oil, M.S. base frame duly primered & painted, supports etc. complete as per specifications and drawings.
Cassette Type: SITC of Imported Air Cooled VRV/VRF Cassette type Indoor units equipped with pre-filter, fan section with low noise fan, multispeed motor, coil section with DX coil, electronic expansion valve, outer cabinet, drain Pump and pan, insulation, pipe connections,control and power panel with corded remote control etc. etc. of various capacities as per specifications and drawings
HI-Wall Type: SITC of Imported Air Cooled VRV/VRF HI-Wall type Indoor units equipped with pre-filter, fan section with low noise fan, multispeed motor, coil section with DX coil, electronic expansion valve, outer cabinet, insulation, pipe connections,control and power panel with corded remote control etc. etc. of various capacities as per specifications and drawings
Installation &Allied Works: Y-joints & header etc above complete as per specification and drawings.
Supply,Installation, testing and commissioning of Centralised remote controllers for operation & status monitoring of VRV/VRF indoor units.
Refrigerant Piping: Supply,installation,testing and commissioning of Interconnecting non exposed refrigerant pipe work with (19mm/13 mm thick) , Class 'O', k value-0.035 w/mk minimum, Density not less than 55 Kg/cu.m closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported with MS hanger & clamps
41.3 mm O.D. (insulation : 19 mm)
34.9 mm O.D. (insulation : 19 mm)
28.6 mm O.D. (insulation : 19 mm)
22.2 mm O.D. (insulation : 13 mm)
19.1 mm O.D. (insulation : 13 mm)
15.9 mm O.D. (insulation : 13 mm)
12.7 mm O.D. (insulation : 13 mm)
9.5 mm O.D. (insulation : 13 mm)
6.5 mm O.D. (insulation : 13 mm)
Supply,installation,testing and commissioning of Interconnecting exposed refrigerant pipe work with (19mm thick) , Class 'O', k value-0.035 w/mk minimum, Density not less than 55 Kg/cu.m closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported with MS hanger & clamps Refrigerant piping will be coated with three layers of feviprotekt (only pidilite) weather coating.
28.6 mm O.D. (insulation : 19 mm)
15.9 mm O.D. (insulation : 13 mm)
Fresh air unit (for VRV): Supply, installation ,testing and commissioning of ventilation Ceiling Suspended Fan Sections of Single Skin Construction made of 18 G pre plasticized GI sheet, belt driven DIDW centrifugal forward curve fan with vibration isolators and canvas connection , squirrel cage induction motor with class-F insulation (IEE-3), mounted within the housing and all other details as in the drawings & specifications. Fan section supplied,filter sections with 50 mm thick washable synthetic type pre filter having efficiency 90% down to 10 micron,fine filters having efficiency 99% down to 3 micron with extruded aluminum frame as detailed in the drawings. The fan motor shall be suitable for operation on Single speed , the motor with Class-F insulation, 415 ± 15 Volts, 50Hz, Ac power.The fan static pressure shall be 80 mm WC static.Makes-(Zeco, System Air, Caryaire)
Fresh Air CFM=600
Ventilation: Inline Fans : Supplying, Installing, Testing and Commissioning of Inline fans complete with motor, supporting frame, gravity louvres,etc. as per drawings and specifications. 300 CFM ,. @ 15mm Static.
Drain Piping:Supply,installation,testing and commissioning of rigid PVC piping complete with fittings, supports as per specifications and duly insulated with 6 mm thick closed cell nitrile rubber class ‘O’ . Providng and fixing pipes with all necessary fittings, supports and insulation.
Ducting: Supply, fabrication, installation, balancing and commissioning of factory fabricated GI sheet metal rectangular ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings of following gauges as per SMACNA standard:- Thickness 24 G sheet
Grilles/Diffusers: Supply,installation, testing and commissioning supply and return air grilles/ diffusers as per specifications and drawings including fixing frame of G.I./wooden in false ceiling/walls.
Aluminium supply air grill with VCD
Aluminium return/exhaust air Diffuser without VCD
Control & Transmission Wiring: Supply,installation,testing and commisioning of control cum transmission wiring of 2 core x 1.5 sqmm unarmoured copper in 25 MM heavy duty PVC conduits between indoor and out door unit & outdoor units to central remotes controllers.
Weather Proof isolators: Supply, installation, testing and commissioning of out door weather proof switch box of continuous welded construction, fabricated out of 2 mm thick G.I. sheet complete with water tight gasket with front openable and lockable door including earthing, painting, glands, danger boards etc. suitable for mounting on wall with M.S. angle iron frame of size 40x40x6 mm consisting of relevant I.S. specifications and drawings. Weather proof box with MCCBs of suitable ratings near the outdoor units for isolations for VRV Outdoor Units.(63 Amps)
Electrical cable: Supply of PVC insulated armoured Copper conductor cables of 1.1 Kv grade 4 core - 10 mm2
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. 4 core - 10 mm2
Termination: Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 core - 10 mm2
S. R. ASHOK & ASSOCIATES PVT. LTD.
RMS CONSTRUCTION PVT. LTD.
LIRA CONSTRUCTIONS PVT LTD
Bahl Builders Pvt Ltd
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .