Tender Value
₹1.6 Cr
EMD Value
₹2.3 L
Closing Date
18 Feb 2026, 2:00 pmClosed
Provision of Data logger Console and upgradation of S&T/Cnl/SDAH for proper Analytics for Asset maintenance and management over Sealdah division.
SDSTE-SIG-T-43-25-26-CAP~ER
SDSTE-SIG-T-43-25-26-CAP
Open
Works - General
6 Months
Kolkata, West Bengal
₹0
₹2.3 L
18 Feb 2026
22 Jan 2026
4 Feb 2026
A-NON-SCHEDULE/SOR ITEM vide SL. NO. 1 to 26 GIVEN IN SCHEDULE
BEEN SHOWN IN ITEM BREAKUP SEPARATELY.
NON-SCHEDULE/SOR ITEM vide SL. NO. 1 to 26 GIVEN IN SCHEDULE OF WORK. GST HAS BEEN
SHOWN IN ITEM BREAKUP SEPARATELY.
S No. Item Description of Item Unit Qty Rate Amount
SEALDAH DIVISION-S AND T/EASTERN RLY
1 1 "Design and Development of suitable Numbers 106.00 25847.46 2739830.76
logics, Implementation and validation of
Dashboard to display the Real time status
for all the stations, Auto Huts, LC
gates(WSL), IBH, OFC rooms in Sealdah
division at a glance and Design and
development of a dash board to display real
time status of Axle Counters of block
sections for all stations and locations at
data logger control room/sealdah division
and provision of audio alarms for all critical
inputs taken from all Dataloggers and RTUs
to S&T control room at Sealdah division: (i)
Open/Close status of Relay room door (ii)
All IPS inputs (DC-DC converters, SMRs,
Inverters, other redundant IPS modules)
including battery status (iii) All inputs of
power supply from different Telecom
equipments present in OFC room , battery
room,etc, required for proper monitoring of
power supply arrangements and current
status (iv) Status of dual track detection
systems (failure of any one system) for
systems of all combination like dual
MSDAC, SSDAC, HASSDAC, DC track with
SSDAC, etc. (v) Status of Track Feed
Battery Charger (TFBC) (vi) Status of Earth
Leakage Detectors (ELD) (vii) Monitoring of
intermittent failures of boom locking
arrangements for all LC gates (WSL & OSL)
(viii) Status of Media fail of UFSBI and BPAC
for systems with Dual Media provision
(Quad/OFC) (ix) Working of fire alarms (x)
All RDSO approved fault logics should be
shown in the dashboard screen as per the
Division requirement. (xi) Installation,
Testing and commissioning of work
station,Application PC and client PC. Note:
(i) Any other logic required for monitoring
of signalling and telecom gears should also
be provided as per demand of S&T Control.
All the logics for monitoring purpose should
be approved by Sr.DSTE/SDAH through
SSE/Sig/CNL and SSE/Tele/CNL (ii) 'No' in
the unit column indicates 'Per station'"
2 2 "Design, development and Implementation Numbers 228.00 10593.22 2415254.16
of dashboard to display the realtime Status
of LC gate through RTU including (i) IPS
inputs for battery backup or failure of
modules or other sources of power supply
at the LC gates (ii) Relay Room door (iii)
Development of logics to generate audio
and visual alarms in case of IPS or Fire
Alarm failures for all stations and locations
at data logger control room/sealdah
division. (iv) All the indications of RDSO
Power panel of LC Gate should be available
in the dash board. Note: (i) Any other logic
required for monitoring of signalling and
telecom gears should also be provided as
per demand of S&T Control. All the logics
for monitoring purpose should be approved
by Sr.DSTE/SDAH through SSE/Sig/CNL and
SSE/Tele/CNL (ii) 'No' in the unit column
indicates 'Per LC gate'"
SEALDAH DIVISION-S AND T/EASTERN RLY
3 3 "Carrying out relay alteration to the existing Per Relay 10000.00 228.81 2288100.00
relay wiring at relay rack/location box as
per the approved circuit diagram and the
addition of all analog inputs present at site
to the dataloggers/ RTUs . These works
include: (i) Inclusion/ deletion of all Vital
relays and analog inputs as per site
requirements for all stations, LC gates, Auto
huts, IBH, OFC rooms with correct
nomenclature of all relays and analog
inputs. (ii) Carrying out wiring and
validation of potential free contact of OFC
Charger over with Datalogger.(iii)
Configuration & Validation of all relay and
analog inputs and also ensuring proper
working of all in-operative relays and
analog inputs. (iv) The releasing of existing
unused wires and wiring the relays using
16/0.2 mm copper wire as per RDSO Spec.
Wire to be procured from RDSO's approved
source. Inspection : RITES Note: - i)Wire to
be procured from RDSO's approved source
only. All required material like wire,
soldering material, paint etc. To be
supplied by the contractor for execution of
4 4 "Supply of Client PC (Multi Monitor Display Numbers 2.00 296610.17 593220.34
System) Capable for driving 04 Nos of LED
TV Displays of 55" or above.• Processor :
Intel XEON 6 Core CPU 2.1 GHz or higher.•
RAM : 32 GB DDR4 • Storage : 1 TB SSD•
Graphic Card : 4 GB (4 Mini-DP ports per
card) • Power Supply : 800W - 90% efficient
• Keyboard : USB Keyboard • Mouse : USB
Optical Mouse • Speakers : Desktop
speakers 1 set • Operating System :
Windows 11 Pro or latest with Licensed
version •Monitor: 60.5 cm (23.8 inch)
diagonal FHD display or better • Antivirus :
Kaspersky/ Quick heal or better with 01
years subscription minimum.• UPS : 1 KVA
offline UPS with 30 minutes of backup for
the CPU.•02 Nos 128GB Pen Drive.
Warranty : 3 Years. Make- Dell/HP or better.
Inspection : RITES"
5 5 "Supply of STP CAT-6 data cable as per Metre 7000.00 38.39 268730.00
EIA/TIA- 568-B.2-1 or latest. Make: D-Link/
Molex/Comscope or better.. Inspection:
6 6 Laying of Power Cable/STP/UTP CAT- Metre 7000.00 16.10 112700.00
6/Switch Board Cable/OFC/Earth Cable etc.
through flexible PVC Conduit Pipe/ GI
Pipe/HDPE Pipe (where necessary) as per
direction of the Rly. Representative . Note-
This also includes Laying of STP/UTP CAT-6
from Relay room/OFC to Data logger
equipment Room to connect free potential
contact of OFC charger.
7 7 "Supply of conduit pipe size 25mm dia 2 Metre 7000.00 24.80 173600.00
mm thicknessand 3 mtrs standard length
with ISI 9537(Part 3):or latest. Make:
Supreme/Polycab/Jindal/Garware or better.
Inspection : Consignee."
8 8 Fixing of PVC conduit pipe on wall, bridges, Metre 7000.00 5.27 36890.00
platformshed complete with 'U' clamps and
necessary fixture screws etc. as per route
given by site engineer of Railways. Note-
PVC pipe supplied by railway.
SEALDAH DIVISION-S AND T/EASTERN RLY
9 9 "Supply, Installation, wiring, testing & Set 5.00 52118.64 260593.20
commissioning of 55"" LED based VDU
(Professional Monitor) with 4K resolution,
suitable for 24X7 application for Control
Terminal of E.I. System as per RDSO spec.
No. RDSO/SPN/192/ 2019 Ver. 2 or latest
with Technical specification : Display
Technology- In plane Switching(IPS) ,
Display Type- Anti-Glare LCD with direct lit
LED, Display Panel Size( Diagonal)-55"",
Minimum Display resolution (Horizontal X
Vertical ) - 4K UHD-3840X2160 , Life time
60,000 Hrs (Typ.) / 50,000Hrs (Min.), View
angle- 178/178 Degree.Touch Technology-
Infrared(IR), Number of Touch points -20
Nos.,Type of CPU- Inbuilt CPU with slot
provision for open pluggable
specification(OPS), Core-4, SSD Storage-
64GB, Wi-fi & Bluetooth connectivity- In
built Make- LG/SAMSUNG or better
Warranty:- 3 Years Inspection :Consignee."
10 10 "Supply, Installation, wiring, testing & Set 3.00 72033.90 216101.70
commissioning of 65"" LED based VDU
(Professional Monitor) with 4K resolution,
suitable for 24X7 application for Control
Terminal of E.I. System as per RDSO spec.
No. RDSO/SPN/192/ 2019 Ver. 2 or latest
with Technical specification : Display
Technology- In plane Switching(IPS) ,
Display Type- Anti-Glare LCD with direct lit
LED, Display Panel Size( Diagonal)-65"",
Minimum Display resolution (Horizontal X
Vertical ) - 4K UHD-3840X2160, Life time
60,000 Hrs (Typ.) / 50,000Hrs (Min.), View
angle- 178/178 Degree.Touch Technology-
Infrared(IR), Number of Touch points -20
Nos.,Type of CPU- Inbuilt CPU with slot
provision for open pluggable
specification(OPS), Core-4, SSD Storage-
64GB, Wi-fi & Bluetooth connectivity- In
built Make- LG/SAMSUNG or better
Warranty:- 3 Years Inspection : Consignee."
11 11 "Supply and installation of Modular Office Numbers 4.00 122528.20 490112.80
working console. Specification:- Primary
Table Top Material Type-Particle Board,
Type of Material of Finish / Lamination in
Primary Table Top-Laminate, Primary Table
Top Thickness -25 mm. Width of Primary
Table Top (Tolerance ±50 mm)-2400 mm,
Depth of Primary Table Top (Tolerance ±20
mm)- 900mm, Height of Primary Table Top
- 750 mm Secondary Table Top Edges- 'L'
Shaped, Width of Secondary Table Top -
1800 mm, Depth of Secondary Table Top
(Tolerance ±20 mm) -250 mm, Height of
Secondary Table Top-1050 mm Make-
GODREJ or better. Inspection : Consignee."
SEALDAH DIVISION-S AND T/EASTERN RLY
12 12 "Supply of Monitoring device for diagnostic Numbers 3.00 134564.00 403692.00
purpose as per Specification : Processor
Make : Intel Processor Generation
13,Number of Cores per Processor : 16,
Processor Description : Intel Core i7,
Processor Number : Intel Core i7 13700,
Operating System (Factory Pre-Loaded)
:Windows 11 Professional, RAM Size : 8 GB
RAM Expandability up to : 64 GB (using
spare DIMM Slots) Type of Drives used to
populate the Internal Bays : PCIe_SSD ,
Total SSD Capacity :512 GB, Display Size :
27 INCHES, Display Type : Non Touch, Panel
Technology : IPS Display Resolution :
1920x1080 PIXELS Availability of Webcam
integrated with Display : Yes Motherboard-
Chipset Series: Intel Q Series, Chipset
Number : Intel Q670, Warranty : 3 Years.
Warranty : 3 Years, Make : HP, DELL or
better Inspection : Consignee."
13 13 "Supply of Fault and Incident Report Numbers 15.00 19723.73 295855.95
Generation Device. Specification :- Printing
Technology- Laser, Cartidge Technology -
Composit Technology, Paper Size-A4,
Resolution - 1200X1200(Dpi) , Processor
Speed - 400MHz, USB Port- Yes.
Certification-UL,CE, Warranty- 3 Years,
Make HP( HP-Laser 1008W), or supirior
Inspection : Consignee"
14 14 "Termination of Outdoor Cables (Main Per 503.00 7.63 3837.89
Cables /tail cables) at both ends in location Conductor
boxes, cable termination rack in relay
room, station building, generator room etc.
The item includes dressing of cables and
wires with dressing threads as per standard
practice. All material required for this item
will be supplied by contractor. The outdoor
cable shall be terminated in Relay Room,
DG Room, ASM Room etc under supervision
and instructions issued by Engr. incharge of
the work. Inspection: Consignee Note :
Twisting of Quad cable to be done before
termination at location boxes/CT rack/OFC
room/SM Room/CT boxes as per Technical
Policy Circular No-110 dt. 11.06.24"
15 15 "Supply of Disconnect Terminal Block, Numbers 945.00 46.61 44046.45
Screw less type, 4-wire front entry (Two in-
put & Two out-put) The colour will be
decided by Engineer - in - Charge.
(Preferably In Blue, Red & Grey Colors in
the ratio of 1:2:3) Inspection : Consignee "
16 16 "Supply of End plate 2.5mm/0.091 in thick Numbers 98.00 8.47 830.06
as per site requirement. Inspection :
width as per site requirement. Inspection :
18 18 "Supply of Carrier Rails for above 35mm x Metre 32.00 92.37 2955.84
7.5mm, 1mm/0.039 in thickness un-slotted
type as per site requirement. Inspection :
SEALDAH DIVISION-S AND T/EASTERN RLY
19 19 "DURING THE EXECUTION OF THE WORK, Man-Days 10.00 3854.00 38540.00
DISMENTALLING / REFIXING / SHIFTING AND
OTHER ALLIED WORK OF S&T EQUIPMENTS
LIKE VDU, FURNITURE, MONITORING
DEVICE, INCIDENT GENARATION REPORT
DEVICE AND OTHER MISCLLANIOUS WORKS
TO BE EXECUTED. THIS JOB INCLUDES
COST OF RELEASING OF S&T EQUIPMENTS,
GEARS & DEVICES AND RECONNECTION OF
THE SAME AFTER THE WORK. THIS WORK
TO BE EXECUTED AT ANY TIME OF DAY /
NIGHT AS PER THE INSTRUCTION OF
RAILWAY SITE ENGINEER(S). 1 ELECTRICAL
WIRE MAN, 2 FITTER & 1 KHALASIS/
HELPERS TO BE PROVIDED PER DAY AS
ONE(1) GANG FOR THIS JOB. Note: Mandays
in unit column indicates Per Day/Per Night"
20 20 "Supply of Office Chair make Godrej interio Numbers 34.00 5063.00 172142.00
legs office chair non-revolving and non-
tilting chair with arm rest , Understructure
materials - ERW tube conforming to IS :
1161 latest, Shoe/Studs materials-
Polypropylene , Seat material - Moulded PU,
Thikness of PU used in seat- 45mm, width
of Seat- >450mm, Backrest material- Mesh,
width of back rest- >450mm. Make- Godrej
or better quality of reputed brand.
Inspection: Consignee"
21 21 "Supply of Steel Plain Almirah with 4 Numbers 15.00 14544.92 218173.80
adjustable slaves Size: 1980mm height, 915
mm width and 485 mm depth. Make-
Godrej or better Inspection: Consignee"
22 22 "Supply & installation of Color LaserJet Numbers 4.00 412295.76 1649183.04
Managed multifunction Printer (Print, copy,
scan, fax) (A4/A3/Legal size) with having
Print technology:Laser, Print Speed:
Monochrome Black & Color :31 to 35 PPM,
Display: Touchscreen Color Graphic Display
(CGD) , Connectivity:USB Port ,Ethernet
Port,Wi-Fi, Min 02 Nos Paper Tray, Scanner
type:ADF & Flatbed, Scan resolution: Up to
600 x 600 dpi or better, Warranty : 3 Years
Make-HP Color LaserJet Managed MFP
E78635dn/Brother or better. Inspection:
23 23 "Supply of 1TB Solid State Drive (SSD) with Numbers 20.00 9313.56 186271.20
speeds of up to 1050MB/S1 and write
speeds of up to 1000MB/S1, Password
enabled, Cross compatible USB 3.2 gen-2
and USB-C, Warranty : 3 Years, Make-
SanDisk/Seagate or better. Inspection:
Synchronization of Datalogger and RTU
clocks with GPS. Make- Efftronics or better.
Inspection: Consignee"
25 25 "Supply of Network Attached Storage (NAS) Numbers 4.00 76271.19 305084.76
4-Bay Diskstation R1600 Dual-Core or
better having Digital Storage Capacity-
16TB, Hard Drive Size-16TB SSD with 4X
4TB SSD (Make-Seagate or better), Ram-
4GB DDR4 , 2xRJ-45 1GbE LAN-Port, USB
,Data Transfer Rate- 1000 Mbps or
higher,Warranty : 3 Years, Make-Synology
or better. Inspection: Consignee"
SEALDAH DIVISION-S AND T/EASTERN RLY
26 26 "Supply of Network Management System Numbers 1.00 512780.00 512780.00
(NMS) for FOIS/UTS/PRS having Device
Management,fault analysis, performance
and Network Monitoring facility and life
time licensed for 500 devices. The system
must have embedded alarm generating and
management system Hardware and
software requirement as per technical
specification in Annexure A. Inspection:
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .