| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.4 LAccepted-AOC 5 1B TARA ROAD KOLKATA 700026 INDIA | KOLKATA | WEST BENGAL | 700026 | L1 | Accepted-AOC Quoted Lowest Rates | |
| 2 | L2₹13.5 L+₹3.0 L (28.3%)Rejected-Finance 10 10 K S ROY ROAD 10 KIRAN SHANKAR ROY ROAD DALHOUSIE KOLKATA WEST BENGAL 700001 | KOLKATA | WEST BENGAL | 700001 | L2 | Rejected-Finance Quoted Higher Rates |
Tender Value
Refer Docs
EMD Value
₹21,200
Closing Date
4 Jan 2021, 6:00 pmClosed
MAJ SWAPNESH KOLI GE I CG P KOLKATA
DAMODAR COMPLEX GARDEN REACH ROAD KOLKATA 23
COMPREHENSIVE MAINTENANCE OF LIFTS INSTALLED AT BLDG NO P-128 JAMUNA AND INS NETAJI SUBHAS UNDER GE (I) (CGP) KOLKATA
2020_MES_398540_2
8879/E8
Open Tender
Electrical and Maintenance Works
Item Rate
334 days
KOLKATA
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE I CG P KOLKATA
₹21,200
Yes
23 Mar 2021
21 Dec 2020
6 Jan 2021
21 Dec 2020
4 Jan 2021
21 Dec 2020
Amount
Comprehensive maintenance of electrically operated automatic passenger lifts carrying capacity 6 passenger (408 kg) lift speed 1.0 mtr/sec incl gearless unit with full collective control system with automatic sliding steel door to serve from ground floor to 5th floor (G+5) at Bldg No. N-9 (INS NETAJI SUBHASH) Total 01 No lift , keeping the lifts and the accessories in perfect and working condition with the repair/replacement of all defective/wom out parts/components, lubricating of the lifts all as required without affecting normal functioning of lift complete all as specified and directed . (Note :- (1) : The parts shall be genuine and from original manufacturer. (2) Quoted rate will be inclusive of annual load testing of lift through authorised competemt engineer as per state factories act, report to be submitted to the department. (3) Report for forntnightly, monthly, quarterly and auunal maintenace to be carried out and report to be submitted as per performance given by the department. (4) Maintence regime will include checking, cleaning, adjusting and lubricating all equipments and parts to ensure the proper and safe oparation of the lift. (5) The contractor shall the all-in comperhensive maintenance services and to maintain efficeint and prompt response to breakdown; emergency call out or complaint for the timely attendance of installation/ equipment faillaiure and/ or unsatisfactory services uncompliance of this will attract penalty/recovery as per rule set by department. (6) Repair/Replacement of components like cabin fan, cabin LED light, V3F drive of suitable capacity, bettery, infra red sensor, car operating panel, landing opearting panal, over load unit, over unit, microprocessor based contraol panel, electronic module shall be measured and paid separately.
Comprehensive maintenance of IBIJI make electrically operated automatic passenger lifts carrying capacity 8 & 13 passenger single speed with full collective control system with automatic sliding steel door to serve from ground floor to 7th floor (G+7) at Bldg No. N-19 , keeping the lifts and the accessories in perfect and working condition with the repair/replacement of all defective/wom out parts/components, lubricating of the lifts all as required without affecting normal functioning of lift complete all as specified and directed (Total 02 Nos lifts). (Note :- (1) : The parts shall be genuine and from original manufacturer. (2) Quoted rate will be inclusive of annual load testing of lift through authorised competemt engineer as per state factories act, report to be submitted to the department. (3) Report for forntnightly, monthly, quarterly and auunal maintenace to be carried out and report to be submitted as per performance given by the department. (4) Maintenance regime will include checking, cleaning, adjusting and lubricating all equipments and parts to ensure the proper and safe oparation of the lift. (5) The contractor shall provide the all-in comperhensive maintenance services and to maintain efficeint and prompt response to breakdown; emergency call out or complaint for the timely attendance of installation/ equipment faillaiure and/ or unsatisfactory services uncompliance of this will attract penalty/recovery as per rule set by department. (6) Repair/Replacement of components like cabin fan, cabin LED light, V3F drive of suitable capacity, bettery, infra red sensor, car operating panel, landing opearting panal, over load unit, over unit, microprocessor based contraol panel, electronic module shall be measured and paid separately.
Supply, Installation, commissioning & Testing of ARD complete unit suitable for G+5 / G+7 / G+12 auto doorlift, interfaceing with new controllers complete including taking down old one all as specified and directed. (Make : Jeltron/ United Elevator/ADCO/EVS/ATZ Elevators).
Supply and fixing coaxial Cabin fan of 300/250 mm sweep as fixed on site complete including taking down old one all as specified and directed.
Supply and fixing cabin ceiling light fittings LED type 3/6/9 Watt (circular/Squuare type) as fixed on site complete including taking down old one all as specified and directed.
Supply, fixing, testing & commissioning of 15 kw lift duty V3F drive unit suitable for G+12 for 415 volts, AC 50Hz operation complete including taking down old one all as specified and directed. (Make- Yaskawa / Fuji)
Supply and fixing battery 12 volt, 17-30 AH complete including taking down old one all as specified and directed. (Exide/ Amron)
Supply, Installing, commissioning, and testing landing operating panel (flush type incl concealed ms box) with micro stroke luminous push button and digital floor position indicator for G+5 / G+7 / G+12 completed all as specified and as directed including taking down unserviceable one. (Make : ATZ Elevators/Thyssenkrupp/United Elevators)
Supply & fix infra red door curtain sensor/detector consisting of the emitter and receiver, power supply box, flexible cables, Relay output1A, 230V AC/2A 30 V with 96/154 beams operating distance 3000mm complete including taking down old one all as specified and as directed. (Make : WECO/TL JONES/EXCELLA/ADCO/LT ELEVATORS).
Supply and fixing of car operating panel for G+7 automatic lift with actually push button , door open, door close, button digital floor indicator & direction indicator suitable for 24 voltd DC operation complete including taking down old one all as specified and directed. (Make : Jeltron/ United Elevator/ADCO/EVS/ATZ Elevators).
Supply and fixing over load unit rope mounted with overload settable from 110 to 150% capacity of lift OL alarm and lift trip feature complete including taking down old one all as specified and directed.
Supply and fixing of full collective microprosessor based control panel suitable for G+12 automatic lifts, complete voice announcer, interface with existing car door operator and inerfered sensors, operating voltage 110v AC and 24v DC complete including taking down old one all as specified and directed. (Make : Jeltron/ United Elevator/ADCO/EVS/ATZ Elevators).
Supply and fixing battery 12 volt, 7 AH complete including taking down old one all as specified and directed.(Exide/ Amron)
Supply, fixing & testing door electronic module suitable for existing automatic door opertor and operating voltage 230 volts AC complete including taking down old one all as specified and directed. (Make- Genesis / Fermator / Wittur)
United Elevators Pvt Ltd
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .