Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹84.3 LAccepted-AOC | ₹84.3 L | L1 | Accepted-AOC L1 |
| 2 | L2₹84.4 LRejected-AOC TANTIPARA HOOGHLY GHAT P O HOOGHLY HOOGHLY PIN 712103 | HOOGHLY | WEST BENGAL | 712103 | ₹84.4 L | L2 | Rejected-AOC L2 |
| 3 | L3₹84.4 LRejected-AOC | ₹84.4 L | L3 | Rejected-AOC L3 |
| 4 | L4₹84.4 LRejected-AOC RAJABAGAN MOKDUMPUR ENGLISH BAZAR MALDA WB 732103 | ENGLISH BAZAR | MALDA | WEST BENGAL | 732103 | ₹84.4 L | L4 | Rejected-AOC L4 |
Tender Value
Refer Docs
EMD Value
₹1.7 L
Closing Date
10 Feb 2026, 4:00 pmClosed
EE(A-M) Chinsurah (A-M) Division
EE(A-M) Chinsurah (A-M) Division
Installation of New Mainan-I Major RLI Schemes (Handed Over) on Turn-Key Basis under Champadanga (A-M) Sub-Division under Chinsurah (A-M) Division under Core Sector Programme in the District of Hooghly
2026_WRDD_989551_1
WBWRDD/EEAM/CNS/CS /eNIT-16 of 2025-26
Open Tender
CIVIL AND ELECTRICAL WORKS
180 days
Hooghly
Please refer Tender documents.
3 documents required · 3 mandatory
₹1.7 L
2 Mar 2026
19 Jan 2026
13 Feb 2026
20 Jan 2026
10 Feb 2026
20 Jan 2026
Supply of Materials: Supply of 315 mm dia P.V.C. Pipe(Cl-I) with Coupler (Class-II) As per IS 4985:2000 with latest amendments
Supply of 200 mm dia P.V.C. Pipe(Cl-I) with Coupler (Class-II) As per IS 4985:2000 with latest amendments
Supply of 140 mm dia P.V.C. Pipe(Cl-I) with Coupler (Class-II) As per IS 4985:2000 with latest amendments
Supply of 140 mm dia P.V.C. Pipe(Cl-II) with Coupler (Class-II) As per IS 4985:2000 with latest amendments
Supply of 200 mm dia P.V.C. Equal Tee as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)
Supply of 140 mm dia P.V.C. Equal Tee as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)
Supply of 315 mm dia F.T.P. as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)
Supply of 200 mm dia F.T.P. as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)
Supply of 160 mm dia F.T.P. as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)
Supply of 160 X 140 mm P.V.C. Reducer (Class-II) as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)
Supply of 200 X 140 mm P.V.C. Reducer (Class-II) as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)
Supply of 200 X 160 mm P.V.C. Reducer (Class-II)
Supply of 200 X 60º P.V.C. Bend s per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)
Supply of 140 X 60º P.V.C. Bend s per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)
Supply of 140 X 90º P.V.C. Bend s per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)
Supply of 200 mm dia P.V.C. End Cap(Cl-III)
Supply of 140 mm dia P.V.C. End Cap(Cl-III)
Supply of 315 mm dia P.V.C.Extra Coupler (Class-II)
Supply of 200 mm dia P.V.C.Extra Coupler (Class-II)
Supply of 140 mm dia P.V.C.Extra Coupler (Class-II)
Supply of Solvent Cement(Exra)
M.S. ACCESSORIES: Supply and Delivery of Quadrupped Set for Major RLI Scheme
Supply of 150 mm dia C.I. Sluice Valve as per IS 14846(ISI MARKED)
Supply and Delivery of 150 mm dia NB Foot Valve (Flanged type) IS -4038 / 1986
Supply of 150 mm dia Alfa Alfa type Valve (C type) (ISI MARKED)
Supply of 90 degree G.I Bend (both end flanged-ISI marked-IS 1239,Galv- IS4736 150 mm dia bend
150 mm dia bend (With priming)
Supply of Galv. MS Flanged Pipe ISI marked- IS: 1239, Galv- IS4736 150mm.dia (4.8mm) (ISI MARKED)
Supply and Delivery of MS Hose Clamp 150 mm dia 45mm width 2.0mm thick
Supply and Delivery of 150mm dia. CI Tail piece one end flanged other end grooved.
Supply and Delivery of Foundation Bolt For Distrubution Chamber
Supply and Delivery of Foundation Bolt For Electro motor pump set
Supply and Delivery of Nuts & Bolts M 20x80 mm.
Supply and Delivery of Nuts & Bolts M 20x100 mm.
Supply and Delivery of Nuts & Bolts M.16x65 mm
Supply and Delivery of Nuts & Bolts M 16x80 mm
Supply and Delivery of Nuts & Bolts M 16x50 mm
Supply and Delivery of Electro motor pump set, both ISI marked,IS-12615 & IS-6595;Monoblock as per IS 9079 b)200 M3/hr,18m head.(20 HP).
Supply and Delivery of Switch Fuse Unit, ISI marked, IS 60947-63 amps 415 volts A.C. TPN main switch(ISI Marked)
Supply and Delivery of Switch Fuse Unit, ISI marked, IS 60947-200 amps 415 volts A.C. TPN main switch(ISI Marked)
Supply and Delivery of Motor Controller IS 60947;20 HP 3 phase electromagnetic Star-Delta Controllers with 4 pole heavy duty power contactor,single phasing preventor and normal protective features MCB Indicators,push buttons, ammeter & Voltmeter , all in IP54 encloser of min 16 SWG C R sheet, 10 tank process powder coat painted and as per technical specification.
Supply and Delivery of Bus Bar Chambers .(as per appvd. Existing dwg.)-IS60947-200amp
Supply and Delivery of 50 sq.mm. ,3.5 core Aluminium PVC insulated(heavy Duty) armoured electric cable duly ISI certification mark as per IS 7098/1988
Supply and Delivery of 6 sq.mm. ,3 core water proof copper cables ISI marked -IS 694
Supply and Delivery of Compresed Asbestos fibre jointing for Quadruped & Tripod set( for raised surface of Flange as per IS-6392) 500 mm.dia (Table-5)
Supply and Delivery of ISI marked P.V.C.Flexible Hose pipe as per IS 15265 - 150 mm dia
Supply and Delivery of 150 mm dia Foot Valve Leather Washer
Supply and Delivery of Rubber Insertion (for raised surface of Flange as per IS-6392) 300 mm.dia( Table-11)
Supply and Delivery of Rubber Insertion (for raised surface of Flange as per IS-6392) 200 mm.dia( Table-11)
Supply and Delivery of Rubber Insertion (for raised surface of Flange as per IS-6392) 200 mm.dia( Table-5)
Supply and Delivery of Rubber Insertion (for raised surface of Flange as per IS-6392) 150 mm.dia( Table -17)
Supply and Delivery of Rubber Insertion (for raised surface of Flange as per IS-6392) 150 mm.dia( Table -5)
Laying of WTA : Earthwork in excavation of foundation trenches or drains in all sorts of soil (including mixed soil but excluding laterite and sand stone), including removing, spreading or stacking the spoils, within a lead of 75 m as directed.The item includes necessary trimming the sides of trenches, levelling,dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1500 mm
Earthwork in excavation of field trenches as per designed section & alignment for laying of pipe lines(PVC,RCC,ACP etc.) upto a depth of 1500 mm in all sorts of soil including removing, spreading or stacking extra earth as directed.The item includes necessary trimming the sides of trenches, levelling,dressing and ramming the bottom as required complete
Laying of P.v.C. pipes of different diameters within field trenches in curve / straight line using P.V.C. fittings, viz. Bend, Tee, Reducer etc. and making leak proof joints with couplers after roughening the surface with wire brush and emery paper and applying solvent cement (The rate is inclusive of transport of pipes, fittings and solvent cement to be supplied by Deptt.) all complete as per direction of Engineer-in-Charge. a) 315 mm dia
b) 200 mm dia
c) 140 mm dia
Earth work in filling in trenches after laying pipe lines (PVC,RCC,ACP etc.) with good earth obtained from excavation of field trences in layer not exceeding 225 mm , including watering & ramming etc. layer by layer complete. (payment will be made on the basis of measurement of finished quantity of work)
Filling in foundation or plinth by Silver sand in layers not exceeding 150 mm as directed and consolidated the same by through saturation with water ramming complete including the cost of supply of sand.
Single brick flat soling of picked Jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Ordinary Cement concrete (Mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement , if any, in ground floor as per relevant IS codes.(a) Pakur vareity
Ordinary Cement concrete (Mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement , if any, in ground floor as per relevant IS codes.(a) Pakur vareity
Hire and labour charges for shuttering with centering and necessary staging upto 4 metre using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor). 25 mm. to 30 mm. thick wooden shuttering as per decision & direction of Engineer-In-Charge
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction. For works in foundation, basement and upto roof of ground floor / upto 4m. Tor steel/Mild steelI. SAIL/ TATA/RINL ( i)For foundation Blocks of Water Distribution System
Brick work with Ist class brick in cement mortar (1 : 6) . (a) In foundation and plinth
Brick work with Ist class brick in cement mortar (1 : 6) . (a) In superstructure ground floor.
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (i) With 1:6 cement mortar (c) 15 mm thick plaster.
Neat cement punning about 1.5 mm. thick in wall dado, floor, drain, door and window sill etc. Complete.
Fitting and fixing of M.S. / G.I. / C.I.accessories and special in pipe line (accessories & special to be supplied departmentally) including supply of jointing materials viz.rubber insertion, nuts & bolts, havoc Zink (Zink Oxide) complete as per direction of Engineer-in-Charge. a) 150 mm dia sluice valve.
Labour Charges for fitting, fixing and laying, where necessary of following M.S / G.I. / E.R.W. pipes and accessories (to be supplied departmentally) including transportation of the same cutting, threading, jointing and making leak-proof threaded / flanged joint at site, by using socket / rubber insertion, nuts and bolts etc. maintaining proper alignment and level - all complete - as per direction of Engineer-in-Charge. (i) 150 mm. dia. ERW pipe.
Erection, fitting, fixing of set of M S Quadruped inlet and outlet pipe fittings for 1st chamber and 2nd chamber of Major RLI Scheme. (Rate inclusive of transportation from departmental store to work site)
Supplying, fitting and fixing including transportation of Sign board of MS fabricated Structure Sheet Size 2 m x 1 m x 1.5 mm thick, MS flat bar (40 mm x 6 mm) welded with frame with 2 nos. MS Angle post (45 mm x45 mmx6mm) of 2.44 m length embeded 0.6 m into 1:2:4 Cement Concrete pasting flex on the MS Sheet ( 2 m x 1 m) as approved signage. This will include Civil construction works of foundation, Painting , material , fitting fixing and labour complete as per Drawing and direction of EIC
Placing and positioning the centrifugul pump motor base/ pump house floor aliging property with necessary packing and fixing the set with holding down nuts and washer including cutting holes of requisite size as complete and direction of EIC. 20 HP capacity
Labour charges for fitting, fixing 150 mm. Dia. Alfa-Alfa valve with 140 mm. dia.P.V.C. pipe with the help of flanged P.V.C. tail-piece by joining the P.V.C.End of Tail-piece and riser pipe with coupler and flanged end of Tail-piece and Alfa-Alfa valve with rubber insertion, nuts and bolts etc. complete.
Testing of pipe line system against leakages by filling the distribution chamber with water and supplying water through the entirepipe line net work for at least 4 (four) hour by running the departmental Diesel Engine pumping set, including supplying necessary fuels & lubricants and hiring and transporting tools and plants all complete as per direction of Engineer-in- Charge. for Major
For Water transmission Arrangement of RLI I 4% extra over the schedule rates, save & except for earth work in excavation & filling works, will be allowed for extra carriage by cart I boat I head load besides initial transport by truck etc.
Add GST @ 18 % on every Items from Item No. 2.01 to 2.25
Add Cess @1% on every Items from Item No. 2.01 to 2.26
Earthwork in excavation of foundation trenches or drains in all sorts of soil (including mixed soil but excluding laterite and sand stone), including removing, spreading or stacking the spoils, within a lead of 75 m as directed.The item includes necessary trimming the sides of trenches, levelling,dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1500 mm. (considering 50 mm clearence)
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidated the same by through saturation with water ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)
Single brick flat soling of picked Jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Ordinary Cement concrete (Mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement , if any, in ground floor as per relevant IS codes.(a) Pakur variety
Ordinary Cement concrete (Mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement , if any, in ground floor as per relevant IS codes.(a) Pakur variety
Hire and labour charges for shuttering with centering and necessary staging upto 4 metre using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor). 25 mm. to 30 mm. thick wooden shuttering.
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction. For works in foundation, basement and upto roof of ground floor / upto 4m. Tor steel/Mild steel ( Other than SAIL/ TATA/RINL) i)For foundation Blocks of Water Distribution System
Brick work in cement mortar (1 : 6) with first class kiln burnt bricks including racking out joints, scaffolding and other incidental works etc. complete. a) In foundation & plinth.
b) In superstructure ground floor
Plaster (to wall, floor, ceiling etc.) with (1:6) sand and cement mortar including rounding off or chamfering corners, as directedand racking out joints or roughening of concrete surface including throating. Nosing and drip course as necessary at ground floor. (a) 15 mm thick (1:6) proportion.
b) 20 mm thick with 1:6 cement mortar.
c) 10 mm thick with 1:4 cement mortar.
25 mm. thick damp proof course with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10 mm nominal size] and admixture of water proofing compound as per manufacturer's specification followed by two coat of polymer based paint, (1st coat after 4 to 5 days of concrete laying and 2 nd coat just before brick masonry work) as directed (cost of water proofing compound & polymer based paint to be paid separately).( Chequering not required over concrete or painted surface). [Note: - Water proofing as per item 9, polymer based paint as per item 8 (a) of subhead C of Section (C).
Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor.3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement).Using grey cement(ii) 25 mm. thick
Neat cement punning about 1.5 mm. thick in wall dado, floor, drain, door and window sill etc. complete.
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows,railing etc. fitted and fixed with necessary screws and lugs in ground floor.(ii) Grill weighing above 16 Kg./sq.mtr and above.
Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than 150 mm apart complete in all respect as per design including cost of all labour and materials.
Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete . A) UPVC Pipes:(i) 75 mm. Dia
B) UPVC Fittings:a) Plain Tee (i) 75 mm. Dia
c) Bend 87.5 degree (i) 75 mm. Dia
Earth work in filling in foundation trenches or plinth with good earth in layer not exceeding 150 mm. Including watering and ramming etc. layer by layer complete with earth obtained from excavation of foundation.
Priming one coat on steel or other metal surface with synthetic enamel / oil bound primer of approved quality including smoothening surfaces by sand papering etc.
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary. Two coats (super gloss hi- gloss except white) Steel surface iv) Two coats (with any shade except white)
White washing including cleaning and smoothening surface thoroughly (5 parts of stone lime and 1 part of shell lime should be used in finishing coat) all floor
Applying decorative cement based paint of approved quality after preparing the surface including scraping the same thoroughly (plastered or concrete surface) as per manufacturer's specification.
Suppling 1 mtr x 0.6 m x 24 swg MS board contaning list of spout wise water users by making numbers of spout as directed by EIC. The board should have base colour - Black and words - White to be fitted and fixed on the wall of the pump house.
Add 4% Carrige as applicale of Construction of Pump House
GST @ 18% on every item from (Sl no 3.01 to 3.27)
Labour welfare Cess@1%on every item from (Sl no 3.01 to 3.28)
Supplying, fitting & fixing 350 mm x 250 mm x 25 mm size Wooden Plank on wall I(for fitting & fixing of electrial equipments as necessary on the plank). (WRDD schedule Item no-9 ,Page-42,Sl no-8)
Supply, Fitting & fixing of DPIC main switch 15/16A 240 Volts (Havells) on board on wall including mending good the damage for light circuit of pump house (PWD elec. Sh. Page-D-1,item -1(a)
Supplying & Fixing bulk head light fitting (Havells make) with die cast aluminium housing & frosted glass on wall/ceiling incl. S&F 8watt CFL / 100 watts GLS lamp complete set (PWD elec. Sh. Page-D-13,item- 1(23)
Supply & Fixing of 20 watt single / twin florescent light fitting complete with all accessories directly on wall / ceilling / TW round block and suitable size of fastener ..((PWD elec. Sh. Page-D-13,item- 24)
Wiring from 15/16A DPIC main switch to Busbar box in 1.1KV grade single core stranded 'FR' PVC insulated and unsheathed copper wire (Finolex/havells/KDK) of 2 x 36/0.3(2.5 Sq. mm) + 1 x 22/0.3(1.5 Sq. mm) in PVC casing capping (Precision make) including necessary PVC clips,fittings etc incl supply of wire. (PWD elec. Sh. Page-E-11,,item-1)
Wiring from 15/16A DPIC main switch to BDB in 1.1KV grade single core stranded 'FR' PVC insulated and unsheathed copper wire (Finolex/havells/KDK) with 2X 36/0.3(2.5 Sq. mm) + 1 X 22/0.3(1.5 Sq. mm) in PVC casing capping (Precision make) including necessary PVC clips,fittings etc.incl supply of wire (PWD elec. Sh. Page-E-11,,item-1)
Distribution wiring in 1.1KV grade 2 x 22/0.3 (1.5 Sq. mm) single core stranded 'FR' PVC insulated and unsheathed copper wire (Finolex/havells/KDK) with 1X22/0.3 (1.5 Sq. mm) single core stranded 'FR' PVC insulated and unsheathed copper wire for ECC, including necessary PVC clips,fittings etc. to light/fan/calling bell with piano key type switch of (Anchore make) fixed on sheet steel fabricated switch board with perspex/ bakelite top cover on wall including necessary connections and making earthing attachments and mending good damages to the building works incl. supply of wire.[PVC casing capping and switch board both on surface] average run 5 meter
Supply & Fixing 240 V, 4 nos. 6A, plug socket with separate 4 nos. 6 A Piano key type switch, indicator & 16A kit-kat flush type fuse (Brand approved by EIC) on sheet metal switchboard embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessaryconnections as require
Fitting & fixing of 200A 500 V iron clad/ sheet steel TP/ TPN main switch on iron legs on wall.
Fitting & fixing of 63A 500 V iron clad/ sheet steel TP/ TPN main switch/isolators on iron legs on wall .
Fitting & fixing of only 200A 500V iron clad M.S. sheet metal busbar chamber on angle iron frame on wall for 4 bars 63Amps .
Fitting & fixing of Star - Delta starter (for 20 HP motor contol) on angle iron frame on wall .
(ii) 3C X 16 sqmm copper cable conforming to IS 694 [Busbar to 63 A, TP Main switch and 63 A TP switch to Motor starter]
Suppling & fitting & fixing of danger Board (mannual) 4"x6" in two distinguishing position in the door of pump house (outside) and at the palce of panel board. (PWD elec. Sh. Page-D-13, item- 21(a))
Earthing with 50 mm (2") dia Galvanized iron pipe(TATA MAKE) 3.64 mm thick X 3.04 mtr.(10ft) long and 1X4 SWG G.I.(Hot Dip) Wire (4 mtr. Long ) 13 mm (1/2") dia X80 mm (3") long G.I. Bolts, double nuts and double washer including S&F 15 mm dia G.I. Pipe protection (1 mtr) long to be fitted with bitumen partly under the ground level and partly above the ground level driven to an average depth of 3.56 mtr. (12") below the ground level and restoring the surface duly rammed for Soft/Morrum soil by ISI-Medium G.I. Pipe
Supplying and fixing earth bar of galvanized M.S. Flat 25 mm × 6 mm on wall having clearance of 6 mm. from wall including providing drilloed holes (on busbar) about 3 cm. apart complete with G.I. bolts, nuts, washers etc. as required for tapping.(PWD elec. Sh. Page-G-2, item-4a)
Connecting the equipments to earth busbar including supplying and fixing G.I. Wire No. 8 SWG on wall/floor with stapples burried inside floor/wall as required and making connection to equipments with bolts, nuts, washers, cable, lugs etc. as required and mending good all the damages..(PWD elec. Sh. Page-G-2, item-5a)
Suppling fitting & fixing of shock treatment chart in a wooden frame with brass. (Passed rate of SE(A-M) Burdwan (A-M) Circle)
Add 18% GST from tem no 4.01 to 4.23
Add 1% Labour cess from tem no 4.01 to 4.24
ENERGISATION: Materials Pcc Pole 9 mtr long
GI STAY SET HT
G I STAY WIRE 7/3.15MM
Porcelain guy insulator HT
G I EARTH SPIKE 1833X20MM
G.I. WIRE 5 MM.
DTR 63 Kva
Polymer Pin insulator 11 kv
Polymer Disc insulator 11 kv
Hard wire fittings 11 kv
PVC Cable 50 sqmm 4 core
LT Kiosk 63 kva DTR
ACSR 50 sqmm
Pcc Pole 8 mtr long
GI STAY SET LT
G I STAY WIRE 7/2.5MM
Porcelain guy insulator LT
1.1 LT AB cable 70 sqmm
Eye Hook
Anchor Clamp
Connector
SMC Box
MS V Bracket 11 kv 9 mtr
MS Top adoptor 11 kv 9 mtr
TPGO Isolator 11 kv
MS Channel 100x50x6 mm
M/S Channel 75x40x6 mm
M/S Angle 65x65x6 mm
M/S Flat 65x6 mm
Labour Cost: Conduction of Physical Survey Using VM APP
Painting of Digits for Unique pole No on Pole
Earthing Complete
Survey HTOH line
Survey LTOH line
Service connection charge 3 ph PRO- A with materilas
Erection of Sub Stn DP 9 mtr pcc pole
Erection of DP Structure 9 mtr pole HT
Erection of Single Pcc Pole 9 Mtr long HT
Erection of Stay Set Complete HT
Erection of Stay Set Complete LT
Erection of Single Pcc Pole 8 Mtr long LT
Sagging with 1.1 LT AB Cable 70 sqmm
Fixing of Anchor (Dead end) Clamp
Fixing of Connector
Fixing of SMC Box
Fixing of Pin insulator 11 kv
Fixing of Disc insulator 11 kv
Erection of 63 kva DTR
Extension PCC pole
Re fixing of Pin Insulator 11 KV
Re fixing of MS V Bracket & Top Adaptor 11 KV
Fixing of TPGO isolator 11 kv
Sagging with ACSR 50 sqmm x 3 w
Re Sagging with ACSR 50 sqmm x 3 w
Fixing of LT Kiosk
Earthing DTR Nutral with materials
Fixing of LA
Fixing of T off Bracket on SP
Cess @ 1% on (Labour+Material+Suprvision)
GST @ 18% on Labour Charge
Quotation Money as per WBSEDCL Procedure
Campaigning in the command area of New Major RLI Sub-project by community workers for mass awareness , capacity building to achieve sustainability of Sub-projects. Cost include wage payment to community workers, transportaton, leaflet etc.
Meeting Cost for WUA formation, cost including Refreshment, training materials, transport local conveyance, wage payment to community worker, remuneration to resource person and incidental charges [Approved estimate regarding activities for institutional development for sustainability of project
Registration Cost for WUA under suitable act ( Society ) deed writing including registration charge, conveyance cost & opening of Bank A/C Charges etc [Approved estimate regarding activities for institutional development for sustainability of project
Livelyhood plan / Micro plan formulation cost for minor irrigation scheme, cost including refreshment, training materials, transport local conveyance, wage payment to community worker, remuneration to resource person and incidental charge ( rate on meeting ) [Approved estimate regarding activities for institutional development for sustainability of project
Meeting and onsite demonstration for operation & maintenance of one New Major RU , water manangement and mode of collection of water tax, building of corpus fund etc [Approved estimate regarding activities for institutional development for sustainability of project
IEC Materials ( Leaflet, poster, notebook )= 8 meetings, for SL - 2 and SL-4 [Approved estimate regarding activities for institutional development for sustainability of project
Documentation Cost for activities of WUA Scheme - by still photography, report booklet etc in both hard and soft copy.[Approved estimate regarding activities for institutional development for sustainability of project
Impact study & monitoring of scheme by site visit of 2 Community workers during 3 years' period [Approved estimate regarding activities for institutional development for sustainability of project
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.14 MB
Tendernotice_2.pdf
PDF • 0.51 MB
BOQ_2417935.xls
BOQ • 0.49 MB
Download all tender documents and submit your bid