| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.9 CrAdmitted-Finance UNIT NO 12 4 MERLIN ACROPOLLS 12TH FLOOR 1858 1 RAJDANGA MAIN ROAD KOLKATA 700107 WB | KOLKATA | WEST BENGAL | 700107 | ₹11.9 Cr | L1 | Admitted-Finance |
| 2 | L2₹12.6 CrAdmitted-Finance | ₹12.6 Cr | L2 | Admitted-Finance |
| 3 | L3₹13.2 CrAdmitted-Finance | ₹13.2 Cr | L3 | Admitted-Finance |
| 4 | L4₹13.6 CrAdmitted-Finance JAIPUR RAJASTHAN 302019 INDIA UDYAM RJ 17 0101683 | JAIPUR | RAJASTHAN | 302019 | ₹13.6 Cr | L4 | Admitted-Finance |
| 5 | L5₹13.9 CrAdmitted-Finance | ₹13.9 Cr | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Kanohar Electricals Limited L5 | Ashoka Buildcon Ltd L2 | Suncity Urja Private Limited L4 | Lumino Industries Limited L1 | J K Electric Contractor LLP L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00MAIN MATERIAL/ ITEMS | ||||||||
| 2.00Circuit Breakers | ||||||||
| 3.00220 kV Circuit Breakers | ||||||||
| 4.00220kV circuit breakers (3 Ph.) Along with support Structure | ||||||||
| 5.00 | 2500 A, 50 kA | 4 | Nos. | 27,64,000 ₹32.6 L | 24,58,853.01 ₹29.0 L | 24,83,250 ₹29.6 L | 20,82,917 ₹25.2 L | 21,60,000 ₹26.5 L |
| 6.00132 kV Circuit Breakers | ||||||||
| 7.00132 kV circuit breakers (3 Ph.) Along with support Structure | ||||||||
| 8.00 | 1250 A, 40 kA | 7 | Nos. | 10,19,000 ₹12.0 L | 10,38,182.38 ₹12.3 L | 10,83,600 ₹12.9 L | 8,20,543 ₹9.9 L | 7,80,000 ₹9.6 L |
| 9.0033 kV Circuit Breakers | ||||||||
| 10.0033 kV circuit breakers (3 Ph.) Along with support Structure | ||||||||
Tender Value
₹55.3 Cr
EMD Value
₹1.1 Cr
Closing Date
9 Dec 2024, 4:00 pmClosed
SE(Contracts-I), RVPN, Jaipur
SE(Contracts-I) O/o CE(Contracts), New MM Building of RVPN, Old Power House Road, Near Ram Mandir, Bani Park, Jaipur
Construction of 220 KV GSS at Sumerpur (Distt. Pali) (Upgradation) on Turnkey Basis under BN-9018002417
2024_RRVPN_430009_1
RVPN/EHV/BN-9018002417
Open Tender
Electrical Works
545 days
Jaipur
Please refer tender documents
25 documents required · 25 mandatory
₹23,600
As per Bid Specification
₹1.1 Cr
Jaipur
30 Dec 2024
5 Nov 2024
9 Dec 2024
5 Nov 2024
9 Dec 2024
21 Nov 2024
13 Nov 2024
Amount
MAIN MATERIAL/ ITEMS
Circuit Breakers
220 kV Circuit Breakers
220kV circuit breakers (3 Ph.) Along with support Structure
132 kV Circuit Breakers
132 kV circuit breakers (3 Ph.) Along with support Structure
33 kV Circuit Breakers
33 kV circuit breakers (3 Ph.) Along with support Structure
Instrument Transformers
Capacitor Voltage Transformer
Single-Phase, 220 kV, 4400 pf CVT
Single Phase 132 kV , 4400 pf CVT
33 kV Potential Transformer
Current Transformer (1-Phase)
C&R Panels & SAS system (Complete in all respect, refer Section-V A, B, Part-III, Volume-II)
New Substation
Control Panel for 220 kV Transformer (220 kV Side) Type: SAS-THCB
Relay Panel for 220 kV Transformer (for both HV & MV) Type: SAS-THRB
Control Panel for 220 kV Feeder Type: SAS-FCB
Relay Panel for 220 kV Feeder Type: SAS-FRB
Control Panel for 220 kV Bus Coupler Type: SAS-BCCB
Relay Panel for 220 kV Bus Coupler Type: SAS-BCRB
220 kV Busbar Protection Relay Panel Type: SAS-BBRB
Control Panel for 220 kV Transformer (132 kV Side) Type: SAS-TLCB
Relay Panel for 220 kV Transformer (132 kV Side) Type: SAS-TLRB
Control and Relay Panel for 1x 50/31.5/25 MVA, 132/33 kV Power Transformer Type SAS-TCRA
Control Panel for 132 kV Feeder Type SAS-FCA
Relay Panel for 132 kV Feeder Type SAS-FRA
Control and Relay Panel for 132 kV Bus-Coupler Type SAS-BCRA
Control and Protection Panel for 33 kV Feeder (I/C, O/G)/Bus-coupler/ Capacitor Bank [For TWIN FEEDER/BAY] Type-FCRD
Station HMI [Industrial grade Computer with 21"TFT monitor as per specification requirements]
Station HMI (Hot Standby)[Industrial grade Computer with 21"TFT monitor as per specification requirements]
HMI View Node[Industrial grad Computer with 21"TFT monitor as per specification requirements]
A3 Size B&W Laser Printer
Substation Automation System Network Panel Type SAS-NW
Modems (both sending and Receiving End) for communication to RCC & Sub SLDC for PLCC]
Data Concentrator Unit (DCU) at Substation for RAS mounted in suitable enclosure & fully wired
Software: Application as well as System Software as per specification requirements for various hardware elements for meeting of functional requirement of the specification.
Substation Auxiliary Monitoring Panel Type SAS-SAMP
Other Items:
Fiber optic cables, connectors, ethernet cables, jack panels connectors, patch cords etc. for completing the Substation LAN as per specification requirements.
Transducers, Sensors etc. (if not considered in the respective equipment/ items) for accumulating monitoring data as per the specification requirements for switchyards.
Surge Arresters
Substation LT Transformer
33/ 0.433 kV, 250 kVA LT transformer complete with all accessories, fittings, terminal connectors etc as specified filled with transformer oil
Batteries & Battery Charger
Batteries (Sizing shall be as per requirement of technical specification)
220 V [Min. 600 AH]
48 V [Min. 600 AH]
Battery Charger System
220 V Float and Boost
50 V Float and Boost
Lighting System
Outdoor Lighting & other Works
Lighting Fixture Type FL-1
Lighting Fixture Type FL-2
Outdoor Receptacle
Type-RP
Type-RO
Substation Premises Lighting
Lighting poles
Type-L1
Type-D1
Street Lighting Type-SL-L1 for mounting on poles
Street Lighting Type-SL-D1 for mounting on Poles
Sub-Lighting Boxes/Panels Type -SLP at Lighting Mast and Other Loaction as designated complete with all controgears and accessories, items etc.
Lighting Panel Type ACP-2 as per technical specification
Lighting Panel Type ACP-3 as per technical specification
Indoor Lighting & Other Works
Electrification
Electric Fitting (if not covered under Civil Works) with G.I. Conduit, Junction Boxes, pull out boxes, copper wiring, Modular Switchboards, Modular Switches, GI Wire (16SWG) etc. for control room, Hall and administrative office building as per the requirements of the specifications
Illumiation
Lighting fixtures and Receptacles (including accessories/ materials etc. as per requirement alongwith complete accessories and mounting arrangements)
Indoor Lignting Panels
Lighting Panel (Indoor) Type ACP-1 as per technical specification
Lighting Panel (Indoor) Type DCP as per technical specification
Wall mounted fans Approx. 400 mm sweep
Ceiling Fan - Approx. 1400mm sweep with electronic Step regulator
Exhaust Fans
Fire Fighting System
Nitrogen Injection Fire Protection System for Auto Transformer (160 MVA ) complete in all respects.
DCP Type
Carbon di oxide type – 6 Liters.
Foam Type- 9 Liters
Sand type
i) GI Buckets 9 liters capacity
ii) Steel Stands for four buckets
Air Conditioning System
Air Conditioning for the Rooms specified in the specifications
1.1kV Grade PVC insulated Al. conductor FRLS power cables and copper conductor armoured FRLS control cables [Excluding the wiring required for electrical & Lighting fittings/fixtures installation in control room and other building]
Power Cables(XLPE)
1Cx630 sq.mm
3.5Cx300 sq.mm
Power Cable(PVC)
1Cx150 sq.mm
3.5Cx70 sq.mm
3.5Cx35 sq.mm
4Cx16 sq.mm
4C x 6 Sq. mm
2C x 6 Sq. mm
Control Cable (PVC)
4 CX4 Sq. mm
3Cx2.5 sq.mm
5Cx2.5 sq.mm
7Cx2.5 sq.mm
10Cx2.5 sq.mm
14Cx2.5 sq.mm
19Cx2.5 sq.mm
Substation Structures
Standard Lattice Structure [Design, engineering, procurement of materials, fabrication galvaising, proto-assembly, FOR destination delivery & erection including nuts, bolts, gusset plates, base plates, foundation bolts, fixing arrangement for control cabinets/MB of equipments and other accessories for lattice steel structure as per specification requirements]:
Non-Standard type Pipe Support Structure [Design, engineering, procurement of materials, fabrication galvaising, proto-assembly, FOR destination delivery & erection including nuts, bolts, gusset plates, base plates, foundation bolts, fixing arrangement for control cabinets/MB of equipments and other accessories for Pipe Support structure as per specification requirements]
Isolators
220 kV (3-Phase) (Horizontal DOUBLE BREAK)
1600A, 50KA, isolator with one E/S
Post insulators for above Isolator
1600A, 50KA, isolator without E/S
Post insulators for above Isolator
1600A, 50KA, isolator without E/S (TANDEM Type)
Post insulators for above Isolator
132 kV (3-Phase) (Horizontal DOUBLE BREAK)
1250A, isolator with one E/S
Post insulators for above Isolator
1250A isolator without E/S
Post insulators for above Isolator
33 kV (3-Phase) (Horizontal DOUBLE BREAK)
1250A, isolator without E/S
Post insulators for above Isolator
800 A isolator without E/S
Post insulators for above Isolator
800A isolator withE/S
Post insulators for above Isolator
Switchyard Erection
Busbar & Interconnections
New Substation/ Switchyard
220 kV Switchyard Works:
Main-I Bus: 220 kV Twin ACSR Zebra Bus with conductor, busbar material, insulator string (DT/SS), AF Type Disc Insulators/Porcelain Long Rod Insulators, hardware, Clamps, Connectors, spacers, corona shields etc. as per Layout arrangment of the subsation and specification requirements [for 3 bays]
Main-II Bus: 220 kV Twin ACSR Zebra Bus with conductor, busbar material, insulator string (DT/SS), AF Type Disc Insulators/ Pocelain Long Rod Insulators, hardware, Clamps, Connectors, spacers, corona shields etc. as per Layout arrangment of the subsation and specification requirements [for 3 bays]
Aux Bus: 220 kV Twin ACSR Zebra Bus with conductor, busbar material, insulator string(DT/SS), AF Type Disc Insulators/ Porcelain Longrod Insulators, hardware, Clamps, Connectors, spacers, corona shields etc. as per Layout arrangment of the subsation and specification requirements [for 3 bays]
220 kV Overhead Jack Bus (for DMT Layout) on Twin ACSR Zebra(Bus-Coupler Bay)/ Single ACSR Zebra (Transformer/ Line on ACSR Zebra) with conductor, busbar material, insulator string (DT/SS), AF Type Disc Insulators/ Porcelain Longrod Insulators, clamps, connectors, spacers etc. as per Substation Layout arrangement and specification requirements [ for 1 Bay]
Twin ACSR Zebra
Single ACSR Zebra
Equipment Interconnections to Main Bus, Overhead Bus including Single ACSR Zebra (for Line), Twin ACSR Zebra (forTransformer bay & B/C Bay), bus-bar materials, clamps, connectors, spacers, corona shields, including equipment connectors, Junction box including of all accessories etc. for the following:
220 kV DMT-type layout
Line bay
Transformer bay
Bus-Coupler
Bus CVT Interconnections to Main Buses including Single ACSR Zebra, clamps, connectors, junction box including of all accessories etc.
132 kV Switchyard Works:
Main Bus: 132 kV Twin ACSR Zebra Bus with conductor, busbar material, insulator string (DT/DS), AF Disc Insulators/ Porcelain Longrod Insulator, hardware, Clamps, Connectors, spacers etc. as per Layout arrangment of the subsation and specification requirements [for 4 bays]
Aux Bus: 132 kV Single ACSR Zebra Bus with conductor, busbar material, insulator string (DT/DS), AF Disc Insulators/ Porcelain Longrod Insulators, hardware, Clamps, Connectors, spacers etc. as per Layout arrangment of the subsation and specification requirements [for 4 bays]
132 kV Overhead Jack Bus (for Main & Aux Layout) on Twin ACSR Zebra(220 kV Transformer/Bus-Coupler Bay), Single ACSR Zebra(132 kV Transformer/Bus-Coupler Bay) Single ACSR Panther (Line on ACSR Panther) on Single Panther ( with conductor, busbar material, insulator string, Disc Insulators, hardware, clamps, connectors, spacers etc. as per Substation Layout arrangement and specification requirements [ for 1 Bay]
Twin ACSR Zebra
Single ACSR Zebra
Single Panther
Equipment Interconnections to Main Bus, Overhead Bus including Twin ACSR Zebra (Bus Sectionalizer/ 220 kV Transformer /Bus-Coupler Bay)/ Single ACSR Zebra (132 kV Transformer Bay) Single ACSR Panther ( Line on ACSR Panther), bus-bar materials, clamps, connectors, spacers including equipment connectors, Junction box including of all accessories etc. for the following:
132 kV Main & Aux-type layout
Line bay
Transformer bay
Bus-Coupler
Bus CVT Interconnections to Main Bus including Single ACSR Zebra, clamps, connectors, junction box including of all accessories etc.
33 kV Switchyard Works:
Aux Bus: 33 kV Single ACSR Zebra Bus with conductor, busbar material, insulator string, Disc Insulators, hardware, Clamps, Connectors, spacers etc. as per Layout arrangment of the subsation and specification requirements [for 5 bays+ Bus Coupler]]
33 kV Overhead Jack Bus for Transformer Incomer (for Main & Aux Layout) on Twin Zebra ( with conductor, busbar material, insulator string, Disc Insulators, hardware, clamps, connectors, spacers etc. as per Substation Layout arrangement and specification requirements [ for 1 Bay]
Equipment Interconnections to Main Bus, Overhead Bus including Twin ACSR Panther ( Transformer /Bus-Coupler Bay)/ Single ACSR Panther ( Line bays), bus-bar materials, clamps, connectors, spacers including equipment connectors, Junction box including of all accessories etc. for the following:
33 kV Main & Aux-type layout
Line bay
Transformer bay
Bus-Coupler
LT Transformer connection with ACSR Panther conductor, 33 kV DO Fuse Set alongwith required Clamp/connectors
Bus PT Interconnections to Main Bus including Single ACSR Panther , clamps, connectors, junction box including of all accessories etc.
Bus Post Insulators (BPI)
Earthing & Lightning Protection System
Main, Auxilary Earthmats, Risers etc. for complete earthing in the Switchyard Area
40 mm Dia MS Rod
40mm Dia, 3.2 M Long MS Rod Earth Electrodes Directly Driven.
40mm Dia, 8 M Long MS Rod Earth Electrodes Directly Driven.
40 mm dia, 3000 mm long GS pipe electrodes with test links and treated earth pits with C.I. cover hinged to C.I. frame alongwith all associated civil works
75X12 mm GS Flat
50X6 mm GS Flat
Earth Enhancing Compound for treated pits as above and other requirement as per specification
Cleat type clamps(8mm thick) for earthing down conductor (10.98 mm dia), 75x12 mm GS Flat and 50x6 mm GS flat
Cu/Al Flexible braids Grounding Conductor connection to MS/GS Flats
Earth Wire for Shielding Protection of Switchyard
7/3.15 Galvenized Steel Wire
Earthwire tension clamps with D Shackle assembly
PG calmp to suit 7/3.15 mm GS earth wire
Cleat clamp on structure to suit 7/3.15 mm GS earth wire/ 75 X 12 mm GS Flat
Pad clamp on structure to suit 7/3.15 mm earth wire and 75 x 12 GS flat
Lug to suit 7/3.15 mm earth wire
Other Clamps, Copper Earth Bond etc. as per layout diagram for erection of Earth Wire
Bay Marshalling KIOSK
200 way (Stud Type Connectors)
AC Distribution Boxes (Outdoor Type)
Outdoor AC Distbibution Box (Double Front type)
Outdoor AC Distbibution Box (Single Front type)
Conduits, Cable Trays [Perforated and Ladder Type], Cable Tags, Cable Clamps, Cable Lugs,Cable sealing system, Gland Plates, Junction Boxes, PVC pipes, hume Pipes, Nylon type Trefoil Clamps etc.[Excluding the conduits, junction boxes etc. required for electrical & Lighting fittings/fixtures installation in control room and other building]
Other Steel Structures/ members [items such as Galvenized/ Mild Steel Channels, Angles, Plates, round, joist, Hot dip galvenized Nut-Bolts, Electro Galvenized Spring Washers etc. considered for this component of price schedule] to be designed/ provided by the bidder for the completion of project [This shall not include the steel to be used in the civil works]
LT Switchgear
LT AC Main Panel
LT AC Distribution Board
Main Lighting Distribution Board
Emergency Lighting Distribution Board
220V DCDB
48V DCDB
PLCC EQUIPMENTS
220 kV Wave trap (2000A, 0.5 mH, 40 kA)
132 kV wave trap (1250A, 0.5 mH, 40 kA)
VFT equipment (Modem) suitable for transmission of Data through PLCC links based on frequency shift keying modulation techniques programmable for both baud rate from 50 Baud to 2400 Baud and center frequency through switches or jumpers (A.F. Shift Channel)
SSB four Channel Carrier Set (40 W) suitable for transmitting Data and super imposed channels along with Remote subscriber facility and emergency calling set.
A.F. Protection coupler microprocessor based suitable for Four commands.
Coupling Devices for Phase to Phase coupling having Band width programmable at site with protective Device & balancing transformer matching with line impedance of respective voltage level.
Coupling Devices for Phase to Ground coupling having Band width programmable at site with protective Device & balancing transformer matching with line impedance of respective voltage level.
HF Armoured Coaxial cable having 75 Ohms unbalanced impendance.
Microprocessor based 32/16 line Electronic Private Automatic Exchange (EPAX) with PLCC interphasing facility
Telephone Sets (Push Button Type)
5 Pair jelly filled armoured telephone cable having copper conductor of Dia. 0.5 mm
5 Pair jelly filled un armoured telephone cable having copper conductor of Dia. 0.5 mm
TESTING & MEASURING INSTRUMENTS, TOOLS & TACKLES AND MISCELLANEOUS ITEMS
(A) TESTING EQUIPMENT/ INSTRUMENTS [This shall consist of all the standard accessories, cables, software etc. required for satisfactory operation of equipment meeting functional requirements]
Insulation Tester (5000 Volts, Digital)
SF6 Leakage Detector
Digital Multimeter
Digital Clamp Meter
PLCC Maintenance/Testing Equipments:
Level generator with a range at 50Hz to 620kHz including facility for synchronization with SLM
8 digit time interval & frequency counter with the frequency range of 10 Hz to 10MHz & timer range of 1 microsec to 1 sec in decade steps.
Dual range 15 MHz oscilloscope with a display screen 8x10 sq.cm and the input impedance of 1 M ohm/25 pF with a deflection coefficient of 5Mv/div to 20 V/div.
4-1/2 digit LCD Multimeter with input impedance of 10Mohm & with a range of 0.1 mV to 1000 V DC, 0.1mV to 600v AC, 0-10 AMP AC,(40hz to 10KHz) & 0-20 Mohm With builtin power –supply.
Print testing Kit for PLCC terminal, protection coupler, EPAX , As per specifications appended at Annexure- V2-P3-S19-2, Volume-II, Part 3, Section-XIX
(B) Maintenance Tools& Tackles
Oil Sampling Bottle (1 Liter Capacity)
Vaccum Cleaner
Telescopic ladder aluminium 6 meter height
Ring spanner set
Tube spanner set
Pipe wrench 24 inch
Pipe wrench 18 inch
Hydraulic crimping tools up to 630 sq.mm
Threading die set for pipe threading
Welding machine (arc welding) 10kVA
Heavy duty drilling machine
Bench Vice
Insulated cuttingplier 12 inch
Insulated cuttingplier 8 inch
Screw driver 18 inch
Screw driver 12 inch
Hammer 8 lbs
Hammer 2 lbs
Chain pulley block 5 ton
Pipe derrick
Allen Keys
Box Spanners
(C )Office and Miscellaneous Equipments/ Items
Insulation Rubber mat (1mX2mX 12 mm)
Isulation Rubber Gloves (15 kV Tested)
Furniture for Control Room Building:
SCADA Room Furniture (Control Desk for specified consoles and Revolving Chair) matching with the overall interiors as per specification
Executive Desk bulit in wood and steel with lockable drawings on both side (6 feetX2 ½ feetx 2 ½ feet)
Junior executive table with three drawings on right side One Cup board left side with prelaminated decolam top 20mm thick over painted M.S. Frame ( 4 ½ feet x 2 ½ feetx 2 ½ feet).
Library Shelf with Glass Door (min 4 Shelf)
Steel tubular “S” type with continuous and one feet dia 14guage pipe, cane seat backing, teak wood with quality cane.
Archival Storage 4 Drive Type
Lateral Filing Cabinets
3 Drawer Unit
4 Drawer Unit
Steel Almirah of size 6 ½ feetx 3 feet x 19 inch with four shelves making five compartments in 22 guage or better with two way locking system.
Steel Almirah (with Glass doors) of size 6 ½ feetx 3 feet x 19 inch with four shelves making five compartments in 22 guage or better with two way locking system.
Minor Almirah of size 4 ½ feet x30 inch x 17 inch with three shelves making four compartments in 22 guage or better with two waylocking system.
Steel rack of size 5 feet x 3 feet x 16 inches with six shelves making five compartments (22 guage).
Steel file trays of size 16 inches x11 inches x 3 inches of guage 14 SWG.
Steel stools of size 15 inch x15 inch x 18 inch square pipe 16 guage
Steel waste paper baskets of size 12 inch (H) and Approx. 10 inch Dia Round.
Key board (wooden) with Glass door
First Aid Box
Shock Treatment Chart [Laminated with Frame]
Safety Instruction Boards [ Laminated with Frame]
(D) Drinking Water Arrangement
Water Cooler (Storage type, Storage Capacity 40 Ltr, Cooling Capcity 20 Ltr./hr)
RO/ Water Purifier
Refrigirator (380 Lt.)
Substation Name Board [1 No. Glow Type & 1 No. Painted Type] [Size and Color etc. be got approved from owner]
Danger Plate [Size and Color etc. be got approved from owner]
Add: Any other supply item, if any, bidder may require completing the substation as per specification requirements.
Description of Work / Item(s)
Amount
Auto Transformer:
220/132 kV, 160 MVA Auto Transformer with all accessories (excluding transformer Oil) as per technical specification
Insulating Oil for 160 MVA 220/132 kV Auto Transformer as per S-I , (1) above
Digital RTCC Panel consisting of Digital RTCC relay as per technical Specification for transformers at S-I (1) above
Circuit Breakers
220 kV Circuit Breakers
220kV circuit breakers (3 Ph.) Along with support Structure
132 kV Circuit Breakers
132 kV circuit breakers (3 Ph.) Along with support Structure
33 kV Circuit Breakers
33 kV circuit breakers (3 Ph.) Along with support Structure
Instrument Transformers
Capacitor Voltage Transformer
Single-Phase, 220 kV, 4400 pf CVT
Single Phase 132 kV , 4400 pf CVT
33 kV Potential Transformer
Current Transformer (1-Phase)
C&R Panels & SAS system (Complete in all respect, refer Section-V A, B, Part-III, Volume-II)
New Substation
Control Panel for 220 kV Transformer (220 kV Side) Type: SAS-THCB
Relay Panel for 220 kV Transformer (for both HV & MV) Type: SAS-THRB
Control Panel for 220 kV Feeder Type: SAS-FCB
Relay Panel for 220 kV Feeder Type: SAS-FRB
Control Panel for 220 kV Bus Coupler Type: SAS-BCCB
Relay Panel for 220 kV Bus Coupler Type: SAS-BCRB
220 kV Busbar Protection Relay Panel Type: SAS-BBRB
Control Panel for 220 kV Transformer (132 kV Side) Type: SAS-TLCB
Relay Panel for 220 kV Transformer (132 kV Side) Type: SAS-TLRB
Control and Relay Panel for 1x 50/31.5/25 MVA, 132/33 kV Power Transformer Type SAS-TCRA
Control Panel for 132 kV Feeder Type SAS-FCA
Relay Panel for 132 kV Feeder Type SAS-FRA
Control and Relay Panel for 132 kV Bus-Coupler Type SAS-BCRA
Control and Protection Panel for 33 kV Feeder (I/C, O/G)/Bus-coupler/ Capacitor Bank [For TWIN FEEDER/BAY] Type-FCRD
Station HMI [Industrial grade Computer with 21"TFT monitor as per specification requirements]
Station HMI (Hot Standby)[Industrial grade Computer with 21"TFT monitor as per specification requirements]
HMI View Node[Industrial grad Computer with 21"TFT monitor as per specification requirements]
A3 Size B&W Laser Printer
Substation Automation System Network Panel Type SAS-NW
Modems (both sending and Receiving End) for communication to RCC & Sub SLDC for PLCC]
Data Concentrator Unit (DCU) at Substation for RAS mounted in suitable enclosure & fully wired
Software: Application as well as System Software as per specification requirements for various hardware elements for meeting of functional requirement of the specification.
Substation Auxiliary Monitoring Panel Type SAS-SAMP
Other Items:
Fiber optic cables, connectors, ethernet cables, jack panels connectors, patch cords etc. for completing the Substation LAN as per specification requirements.
Transducers, Sensors etc. (if not considered in the respective equipment/ items) for accumulating monitoring data as per the specification requirements for switchyards.
Surge Arresters
Substation LT Transformer
33/ 0.433 kV, 250 kVA LT transformer complete with all accessories, fittings, terminal connectors etc as specified filled with transformer oil
Batteries & Battery Charger
Batteries (Sizing shall be as per requirement of technical specification)
220 V [Min. 600 AH]
48 V [Min. 600 AH]
Battery Charger System
220 V Float and Boost
50 V Float and Boost
Lighting System
Outdoor Lighting & other Works
Lighting Fixture Type FL-1
Lighting Fixture Type FL-2
Outdoor Receptacle
Type-RP
Type-RO
Substation Premises Lighting
Lighting poles
Type-L1
Type-D1
Street Lighting Type-SL-L1 for mounting on poles
Street Lighting Type-SL-D1 for mounting on Poles
Sub-Lighting Boxes/Panels Type -SLP at Lighting Mast and Other Loaction as designated complete with all controgears and accessories, items etc.
Lighting Panel Type ACP-2 as per technical specification
Lighting Panel Type ACP-3 as per technical specification
Indoor Lighting & Other Works
Electrification
Electric Fitting (if not covered under Civil Works) with G.I. Conduit, Junction Boxes, pull out boxes, copper wiring, Modular Switchboards, Modular Switches, GI Wire (16SWG) etc. for control room, Hall and administrative office building as per the requirements of the specifications
Illumiation
Lighting fixtures and Receptacles (including accessories/ materials etc. as per requirement alongwith complete accessories and mounting arrangements)
Indoor Lignting Panels
Lighting Panel (Indoor) Type ACP-1 as per technical specification
Lighting Panel (Indoor) Type DCP as per technical specification
Wall mounted fans Approx. 400 mm sweep
Ceiling Fan - Approx. 1400mm sweep with electronic Step regulator
Exhaust Fans
Fire Fighting System
Nitrogen Injection Fire Protection System for Auto Transformer (160 MVA ) complete in all respects.
DCP Type
Carbon di oxide type – 6 Liters.
Foam Type- 9 Liters
Sand type
i) GI Buckets 9 liters capacity
ii) Steel Stands for four buckets
Air Conditioning System
Air Conditioning for the Rooms specified in the specifications
1.1kV Grade PVC insulated Al. conductor FRLS power cables and copper conductor armoured FRLS control cables [Excluding the wiring required for electrical & Lighting fittings/fixtures installation in control room and other building]
Power Cables(XLPE)
1Cx630 sq.mm
3.5Cx300 sq.mm
Power Cable(PVC)
1Cx150 sq.mm
3.5Cx70 sq.mm
3.5Cx35 sq.mm
4Cx16 sq.mm
4C x 6 Sq. mm
2C x 6 Sq. mm
Control Cable (PVC)
4 CX4 Sq. mm
3Cx2.5 sq.mm
5Cx2.5 sq.mm
7Cx2.5 sq.mm
10Cx2.5 sq.mm
14Cx2.5 sq.mm
19Cx2.5 sq.mm
Substation Structures
Standard Lattice Structure [Design, engineering, procurement of materials, fabrication galvaising, proto-assembly, FOR destination delivery & erection including nuts, bolts, gusset plates, base plates, foundation bolts, fixing arrangement for control cabinets/MB of equipments and other accessories for lattice steel structure as per specification requirements]:
Non-Standard type Pipe Support Structure [Design, engineering, procurement of materials, fabrication galvaising, proto-assembly, FOR destination delivery & erection including nuts, bolts, gusset plates, base plates, foundation bolts, fixing arrangement for control cabinets/MB of equipments and other accessories for Pipe Support structure as per specification requirements]
Isolators
220 kV (3-Phase) (Horizontal DOUBLE BREAK)
1600A, 50KA, isolator with one E/S
Post insulators for above Isolator
1600A, 50KA, isolator without E/S
Post insulators for above Isolator
1600A, 50KA, isolator without E/S (TANDEM Type)
Post insulators for above Isolator
132 kV (3-Phase) (Horizontal DOUBLE BREAK)
1250A, isolator with one E/S
Post insulators for above Isolator
1250A isolator without E/S
Post insulators for above Isolator
33 kV (3-Phase) (Horizontal DOUBLE BREAK)
1250A, isolator without E/S
Post insulators for above Isolator
800 A isolator without E/S
Post insulators for above Isolator
800A isolator withE/S
Post insulators for above Isolator
Switchyard Erection
Busbar & Interconnections
New Substation/ Switchyard
220 kV Switchyard Works:
Main-I Bus: 220 kV Twin ACSR Zebra Bus with conductor, busbar material, insulator string (DT/SS), AF Type Disc Insulators/Porcelain Long Rod Insulators, hardware, Clamps, Connectors, spacers, corona shields etc. as per Layout arrangment of the subsation and specification requirements [for 3 bays]
Main-II Bus: 220 kV Twin ACSR Zebra Bus with conductor, busbar material, insulator string (DT/SS), AF Type Disc Insulators/ Pocelain Long Rod Insulators, hardware, Clamps, Connectors, spacers, corona shields etc. as per Layout arrangment of the subsation and specification requirements [for 3 bays]
Aux Bus: 220 kV Twin ACSR Zebra Bus with conductor, busbar material, insulator string(DT/SS), AF Type Disc Insulators/ Porcelain Longrod Insulators, hardware, Clamps, Connectors, spacers, corona shields etc. as per Layout arrangment of the subsation and specification requirements [for 3 bays]
220 kV Overhead Jack Bus (for DMT Layout) on Twin ACSR Zebra(Bus-Coupler Bay)/ Single ACSR Zebra (Transformer/ Line on ACSR Zebra) with conductor, busbar material, insulator string (DT/SS), AF Type Disc Insulators/ Porcelain Longrod Insulators, clamps, connectors, spacers etc. as per Substation Layout arrangement and specification requirements [ for 1 Bay]
Twin ACSR Zebra
Single ACSR Zebra
Equipment Interconnections to Main Bus, Overhead Bus including Single ACSR Zebra (for Line), Twin ACSR Zebra (forTransformer bay & B/C Bay), bus-bar materials, clamps, connectors, spacers, corona shields, including equipment connectors, Junction box including of all accessories etc. for the following:
220 kV DMT-type layout
Line bay
Transformer bay
Bus-Coupler
Bus CVT Interconnections to Main Buses including Single ACSR Zebra, clamps, connectors, junction box including of all accessories etc.
132 kV Switchyard Works:
Main Bus: 132 kV Twin ACSR Zebra Bus with conductor, busbar material, insulator string (DT/DS), AF Disc Insulators/ Porcelain Longrod Insulator, hardware, Clamps, Connectors, spacers etc. as per Layout arrangment of the subsation and specification requirements [for 4 bays]
Aux Bus: 132 kV Single ACSR Zebra Bus with conductor, busbar material, insulator string (DT/DS), AF Disc Insulators/ Porcelain Longrod Insulators, hardware, Clamps, Connectors, spacers etc. as per Layout arrangment of the subsation and specification requirements [for 4 bays]
132 kV Overhead Jack Bus (for Main & Aux Layout) on Twin ACSR Zebra(220 kV Transformer/Bus-Coupler Bay), Single ACSR Zebra(132 kV Transformer/Bus-Coupler Bay) Single ACSR Panther (Line on ACSR Panther) on Single Panther ( with conductor, busbar material, insulator string, Disc Insulators, hardware, clamps, connectors, spacers etc. as per Substation Layout arrangement and specification requirements [ for 1 Bay]
Twin ACSR Zebra
Single ACSR Zebra
Single Panther
Equipment Interconnections to Main Bus, Overhead Bus including Twin ACSR Zebra (Bus Sectionalizer/ 220 kV Transformer /Bus-Coupler Bay)/ Single ACSR Zebra (132 kV Transformer Bay) Single ACSR Panther ( Line on ACSR Panther), bus-bar materials, clamps, connectors, spacers including equipment connectors, Junction box including of all accessories etc. for the following:
132 kV Main & Aux-type layout
Line bay
Transformer bay
Bus-Coupler
Bus CVT Interconnections to Main Bus including Single ACSR Zebra, clamps, connectors, junction box including of all accessories etc.
33 kV Switchyard Works:
Aux Bus: 33 kV Single ACSR Zebra Bus with conductor, busbar material, insulator string, Disc Insulators, hardware, Clamps, Connectors, spacers etc. as per Layout arrangment of the subsation and specification requirements [for 5 bays+ Bus Coupler]]
33 kV Overhead Jack Bus for Transformer Incomer (for Main & Aux Layout) on Twin Zebra ( with conductor, busbar material, insulator string, Disc Insulators, hardware, clamps, connectors, spacers etc. as per Substation Layout arrangement and specification requirements [ for 1 Bay]
Equipment Interconnections to Main Bus, Overhead Bus including Twin ACSR Panther ( Transformer /Bus-Coupler Bay)/ Single ACSR Panther ( Line bays), bus-bar materials, clamps, connectors, spacers including equipment connectors, Junction box including of all accessories etc. for the following:
33 kV Main & Aux-type layout
Line bay
Transformer bay
Bus-Coupler
LT Transformer connection with ACSR Panther conductor, 33 kV DO Fuse Set alongwith required Clamp/connectors
Bus PT Interconnections to Main Bus including Single ACSR Panther , clamps, connectors, junction box including of all accessories etc.
Bus Post Insulators (BPI)
Earthing & Lightning Protection System
Main, Auxilary Earthmats, Risers etc. for complete earthing in the Switchyard Area
40 mm Dia MS Rod
40mm Dia, 3.2 M Long MS Rod Earth Electrodes Directly Driven.
40mm Dia, 8 M Long MS Rod Earth Electrodes Directly Driven.
40 mm dia, 3000 mm long GS pipe electrodes with test links and treated earth pits with C.I. cover hinged to C.I. frame alongwith all associated civil works
75X12 mm GS Flat
50X6 mm GS Flat
Earth Enhancing Compound for treated pits as above and other requirement as per specification
Cleat type clamps(8mm thick) for earthing down conductor (10.98 mm dia), 75x12 mm GS Flat and 50x6 mm GS flat
Cu/Al Flexible braids Grounding Conductor connection to MS/GS Flats
Earth Wire for Shielding Protection of Switchyard
7/3.15 Galvenized Steel Wire
Earthwire tension clamps with D Shackle assembly
PG calmp to suit 7/3.15 mm GS earth wire
Cleat clamp on structure to suit 7/3.15 mm GS earth wire/ 75 X 12 mm GS Flat
Pad clamp on structure to suit 7/3.15 mm earth wire and 75 x 12 GS flat
Lug to suit 7/3.15 mm earth wire
Other Clamps, Copper Earth Bond etc. as per layout diagram for erection of Earth Wire
Bay Marshalling KIOSK
200 way (Stud Type Connectors)
AC Distribution Boxes (Outdoor Type)
Outdoor AC Distbibution Box (Double Front type)
Outdoor AC Distbibution Box (Single Front type)
Conduits, Cable Trays [Perforated and Ladder Type], Cable Tags, Cable Clamps, Cable Lugs,Cable sealing system, Gland Plates, Junction Boxes, PVC pipes, hume Pipes, Nylon type Trefoil Clamps etc.[Excluding the conduits, junction boxes etc. required for electrical & Lighting fittings/fixtures installation in control room and other building]
Other Steel Structures/ members [items such as Galvenized/ Mild Steel Channels, Angles, Plates, round, joist, Hot dip galvenized Nut-Bolts, Electro Galvenized Spring Washers etc. considered for this component of price schedule] to be designed/ provided by the bidder for the completion of project [This shall not include the steel to be used in the civil works]
LT Switchgear
LT AC Main Panel
LT AC Distribution Board
Main Lighting Distribution Board
Emergency Lighting Distribution Board
220V DCDB
48V DCDB
PLCC EQUIPMENTS
220 kV Wave trap (2000A, 0.5 mH, 40 kA)
132 kV wave trap (1250A, 0.5 mH, 40 kA)
VFT equipment (Modem) suitable for transmission of Data through PLCC links based on frequency shift keying modulation techniques programmable for both baud rate from 50 Baud to 2400 Baud and center frequency through switches or jumpers (A.F. Shift Channel)
SSB four Channel Carrier Set (40 W) suitable for transmitting Data and super imposed channels along with Remote subscriber facility and emergency calling set.
A.F. Protection coupler microprocessor based suitable for Four commands.
Coupling Devices for Phase to Phase coupling having Band width programmable at site with protective Device & balancing transformer matching with line impedance of respective voltage level.
Coupling Devices for Phase to Ground coupling having Band width programmable at site with protective Device & balancing transformer matching with line impedance of respective voltage level.
HF Armoured Coaxial cable having 75 Ohms unbalanced impendance.
Microprocessor based 32/16 line Electronic Private Automatic Exchange (EPAX) with PLCC interphasing facility
Telephone Sets (Push Button Type)
5 Pair jelly filled armoured telephone cable having copper conductor of Dia. 0.5 mm
5 Pair jelly filled un armoured telephone cable having copper conductor of Dia. 0.5 mm
CIVIL WORKS
TOWER/ EQUIPMENT FOUNDATIONS :
LATTICE / PIPE STRUCTURE
220 kV tower type AT1
220 kV tower type AT3
220 kV tower type AT4
220 kV tower type AT6
220 kV tower type AT8
220 kV ,LA support structures
220 kV CT, support structures
220 kV CVT support structures
220 kV Tendom Isolator (including associated PIs)
220 kV Isolator
220 kV PI Structure
220 kV Circuit Breaker
132 kV PI Structure
132 kV tower type PQ/Q
132 kV tower type PQR/R
132 kV CT, support structures
132 kV LA support structures
132 kV CVT support structures
132 kV Isolator
33 KV PI Structure
33 kV CT/PT structure
33 kV isolator
145 kV SF6 Circuit Breaker
36 kV Vacuum Circuit Breaker
Marshalling Kiosk
Lighting Mast
FOUNDATION FOR160 MVA, 220/132 kV TRANSFORMER:-
Civil works for MS Tank including Excavation, Laying of 75 mm PCC, Constructing brick wall jacket around the tank, laying of 200 mm RCC raft, leveling and alignment of MS Tank, backfilling with excavated sand, Top leveling by laying of PCC, as per site requirement and Technical specifications (complete job).As per specification for 160 MVA Transformer
CABLE TRENCH
Type A Cable trench
Type C Cable trench
Type D Cable trench -Providing, Laying & Jointing R.C.C. class NP-2 Non-Pressure pipes (IS : 458 mark) of approved make with collars, jointed with C.M. 1:2 or having Spigot and socket ends with flexible rubber rings joints including testing of joints etc. complete for 300 mm dia internal dia pipe including Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto haunches of S.W. pipes including bed concrete as per standard design and Excavating trenches of required width for pipes cables etc. including excavation for sockets, depth up to required depth including taking out the excavated materials, refilling the soil as required in layers not exceeding 20 cm in depth including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, with all lead and lifts in all types of soil, rocks etc complete in all respect.
Construction of RCC sump having capacity 10000 Liters with provision of automatic dewatering mud pump with disposal arrangement upto outside RVPN premises as directed by Engineeer In-charge with provision of a stand by pump.
CABLE TRENCH CROSSING
Road crossing for 'A' type cable trenches
Road crossing for 'C' type cable trenches
RAIN WATER HARVESTING:Designing and providing storm water drainage along with Rainwater harvesting by providing two numbers recharge structures with bore wells as per technical specifications.
ANTI WEED TREATMENT AND BASE LAYER OF INTERLOCKING TILES
Providing and fixing of precast concrete interlocking blocks of M 30 grade 60mm thick manufactured from fully computerised automatic stationery hydraullic vibropressed machine and fully computerised automatic batching plant of class A1/A2 as per BS 6717:2001. The CC interlocking paving blocks be laid on average 50mm. thick bed of coarse sand and the joint is to be filled with fine sand. Laying procedure on compacted sub-base as defined. Complete job is to be executed as per the instruction of Engineer incharge. The rates to be inclusive of all lead, Lifts and taxes. General specification of blocks: 1) Shape as defined by Engineer incharge 2) Tensile splitting strength and braking load as per BS 6717:2001 3) Color: Grey cement natural colour 4) Variation in dimension: Less than 1.6mm. 5) Variation in thickness: Less than 3.2mm 6) Abrasion: As per BS: 6717:2001
JELLY SPREADING (Gravelling)
Providing and laying 100mm thick layer of granite/basalt/trap jelly(gravel) of 40mm single size shall be spread over the entire switchyard area as per drawing and directions of engineer incharge of the work. The whole switchyard area (excluding buildings pathway road, drainages, cable trenches, equipments/ structures/ plinths etc.) shall be covered with jelly spreading. The jelly used shall be free from dirt, organic materials and flakes.
ROAD WORK
Construction of unreinforced, dowel jointed plain cement cocrete pavement in 150 mm thickness over and including sub-base of 150 mm thick quarry rubbish and 100 thick PCC 1:4:8 with M 30 grade cement concrete laid in approved side form work(steel channels , laying and fixing 125 micron thick polythene film wedged, steel plates including leveling the form work as per drawing, spreading using shovels, rakes, compacted using needdle, plate and screed vibrator finished in continuous operation including provision of expansion and contraction and construction joints, applying debonding strips, primer, sealant, dowel bars at expansion & construction joints only, curing etc complete including dewatering process with all equipments. work also includes providing and fixing precast cement concrete solid blocks on outer edges of both sides shoulder of size 60x(20+25)/2x30 cms (l, b, h) jointed with CM 1:4, made from precast M-20 concrete and laid over 100 mm thick base of PCC 1:4:8 including necessary curing etc. complete. The concrete block top shall be 100 mm above road top, with provision of suitable openings for drainage of rain water. The exposed surface of concrete blocks shall be applied with two coat of enamel paint, painted black and yellow alternately, and Providing and laying 80 mm thick M 30 interlocking tiles Category A Denated units to key into each other on four faces zig zag shape over 100 mm PCC 1:4:8, complete as per IRC SP 63:2004 specification on shoulders as per approved drawing, specification and direction of engineer incharge(payment shall be made as per actual length).
4.0 Mtr. Wide Road with shoulders of 1 m on both side of CC road
3.0 Mtr. Wide Road. with shoulders of 0.50 m on both side of CC road
CONTROL ROOM BUILDING
Construction of control room building as per drawing and specification including internal electricafication with Energy Efficient Lights , Tube light fixtures etc, 15 lit storage geyser, earthing, sanitary system including septic tanks, soakage pits and rain water harvesting system as per drawing approved by owner/GWD etc., water supply system including making connection with distribution system, false ceiling (In Hall, PLCC room and XEN chamber), fans,water cooler of cooling capacity 80 lits/hour and storage capacity of 120 lits, RO system withpurification capacity of 25 lits/hour and duty cycle of 170-250 lits/day with PVC tank of 200 lits capacity, internal cable trenches covered with 6 mm thick MS chequred plates, plinth protection works with chequred tiles etc (plinth area approximately 600 sqm, with out roof projections, plinth protection and porch)
WATER SUPPLY :-Supply and installation of water supply system with construction of GLR, submersible cables, pump room with pump and one stand- by pump for the sub-station, required electrifcation cables from control room and panels, providing and laying GI pipe line from GLR to control room, yard, guard room,store, for plantation etc including making connection , landscaping,construction and development of park as per the drawing & plantation as per specification & approved drawings and directions of engineer incharge.
Add: Any other item bidder may require to complete the Civil works as per specification requirements
Kanohar Electricals Limited (BID ID -3004150)
J K Electric Contractor LLP (BID ID -3006360)
Ashoka Buildcon Ltd (BID ID -3004632)
Suncity Urja Private Limited (BID ID -3004120)
Lumino Industries Limited (BID ID -3004005)
Ashoka Buildcon Ltd (BID ID -3004632)
J K Electric Contractor LLP (BID ID -3006360)
Kanohar Electricals Limited (BID ID -3004150)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.08 MB
Commercial_Vol_I_9018002417.pdf
Tender Documents • 9.64 MB
Technical_Vol_II_Part_I_Project_Section.pdf
Tender Documents • 1.07 MB
Drawings.pdf
Additional Documents • 8.75 MB
Technical_Spec_Vol_II.pdf
Tender Documents • 12.34 MB
BOQ_773130.xls
BOQ • 1.18 MB
Download all tender documents and submit your bid