| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.7 CrAccepted-Finance 26 2 SHAKTI NAGAR PAOTA C ROAD JODHPUR | JODHPUR | JODHPUR | RAJASTHAN | ₹9.7 Cr | L1 | Accepted-Finance ACCEPT |
| 2 | L2₹9.7 Cr+₹4.5 L (0.47%)Accepted-Finance | ₹9.7 Cr+₹4.5 L (0.47%) | L2 | Accepted-Finance ACCEPT |
| 3 | L3₹9.8 Cr+₹9.8 L (1.02%)Accepted-Finance | ₹9.8 Cr+₹9.8 L (1.02%) | L3 | Accepted-Finance ACCEPT |
| 4 | L4₹10.1 Cr+₹39.6 L (4.10%)Accepted-Finance | ₹10.1 Cr+₹39.6 L (4.10%) | L4 | Accepted-Finance ACCEPT |
| 5 | L5₹10.2 Cr+₹56.6 L (5.86%)Accepted-Finance | ₹10.2 Cr+₹56.6 L (5.86%) | L5 | Accepted-Finance ACCEPT |
Tender Value
₹12.5 Cr
EMD Value
₹25.0 L
Closing Date
20 Jul 2020, 12:00 pmClosed
Additional Chief Engineer, P.W.D. Zone - Tonk
Additional Chief Engineer, P.W.D. Zone - Tonk
Upgradation of Rural Road of T04 - Gunsi to Raholi Road upto District Border Road in District Tonk in Package No. RJ31/P3/2019/04 under PMGSY-III (Batch-I), WB RRP-II year 2019-20
2020_CERJ_94509_42
02/PMGSY/2020-21 ACE PWD ZONE TONK
Open Tender
CIVIL
Item Rate
300 days
Tonk
Please refer Tender documents.
7 documents required · 7 mandatory
₹5,000
Additional Chief Engineer, P.W.D. Zone - Tonk
₹25.0 L
12 Aug 2020
8 Jul 2020
20 Jul 2020
8 Jul 2020
20 Jul 2020
8 Jul 2020
Amount
Construction of reference bench mark (1 No.), working bench mark (4 Nos.) and near all drainage structures and bridges (as per direction of Engineer-in-charge), reference pillar/ burgees @ 50m interval on both side of formation width including marking of centre line, setting out curves, recording of levels, white washing and lettering etc. complete as per MORD specifications cl. 108.
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per MoRD Specification Clause 201. By Mechanical Means In area of non-thorny jungle
Scarifying the existing bituminous road surface to a depth of 150 mm and disposal of scarified material with a lift upto 3 m and lead upto 1000 m as per MoRD Specification Clause 301.4.
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per MoRD Specification Clause 301.5
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 50 m as per MoRD Specification Clause 301.5
Construction of granular sub-base by providing well graded crusher borken material, mixing in a mechanical mix plant at OMC , carriage of mixed material to work site upto lead of 1000m spreading in uniform layers with Tractor Mount Grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per MoRD Specification Clause 401.For Grading I Material
Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and MoRD Specification Clause 406. By Mechanical Means with all lead
Construction of granular sub-base by providing well graded crusher borken material, mixing in a mechanical mix plant at OMC , carriage of mixed material to work site upto lead of 1000m spreading in uniform layers with Tractor Mount Grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per MoRD Specification Clause 401.For Grading III Material
Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per MoRD Specification Clause 502
Providing and applying tack coat with Bitumen VG-10 using bitumen pressure distributor at the rate of 0.30 to 0.40 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom as per MoRD Specification Clause 503 and IRC-16-2008
Providing and laying bituminous macadam with hot mix plant using crushed aggregates of grading as per Table 500.4 premixed with bituminous binder, transported to site with all leads laid over a previously prepared surface with paver finisher to the required grade, level and alignment and rolled to achieve the desired compaction as per MoRD Specification Clause 504.Add extra for adding Shreaded Plastic Waste as per Guidelines envisaged in IRC:SP:98-2013 over Item No. 5.3 @ 8% of the quantity of Bitumen by weight including mixing of aggregate and plastic waste in Hot Mix Plant( The Bitumen content will be as per respective Clause of MoRD Specifications) Bitumen (VG-30)
Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing of aggregate and plastic waste cutting in a hotmix plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per MoRD Specification Clause 508. Waste Plastic @ 8% of bitumen. Case -II By mechnical means Bitumen VG-30
Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per MoRD Specification Clause 510 By Mechanical Means Case - II : Type B Bitumen (VG-30)
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. 300 mm dia
Construction of Foundation / Inaugration Pedastal in 23 cm thick Brick masonry in CM 1:4 of size 1.20m x 1.80m above ground level with adequate foundation including providing and fixing of Granite stone of size 0.75m x0.60m with engraving letters and figures,cement plaster,white washing etc. complete as per direction of Engineer in charge.
Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with a lift upto 1.5 m and lead upto 1000 m as per MoRD Specification Clause 302.3
Construction of un-reinforced, without dowel bar, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, near approaches to bridge/culvert and construction joints, admixtures as approved, curing of concrete slabs for 14-days, using curing compound and water finishing to lines and grade as per drawing and MoRD Specification Clause 1501 including vaccum dewatering process with all required equipments
Add extra for dowel Bar for Cement Concrete Pavement as per drawing and MoRD Specification Clause 1501
Providing, fabricating and lying form work of plastic cells made from reclaimed High Density Polythelene (HDPE) sheets of thickness 0.20mm to about 0.25mm or LDPE sheets of thickness 0.30mm to 0.35mm thickness, 100mm wide heat welded or stitched to form cell at 300mm interval and fixed with iron spikes of about 200mm long to keep the cell walls taut and with nylon threads to prevent collapse of the cell walls during placement of concrete, form work of cells should be so stiched to form a roll of cells of a pavement width 3.75m and has a length of 10m to 20m and successive rolls of cell to be stapled.
Construction of plastic cell filled cement concrete pavement, with M30 grade concrete, thickness as per design, over a prepared sub base, with 53 grade Ordinary Portland Cement (OPC) or any other type as per Clause 1501.2.4 M30 (Grade). Coarse and fine aggregates conforming to IS : 2386, maximum in a concrete mixer of not less then 0.2 cum capacity and appropriate weigh batcher using approved mix design(As per IRC 44-2088, laid in approved fixed side formwork (steel channel, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using screed and plate vibrators and finished in continuous operation, Concrete should have a slump of 30-50MM with use of approved plasticizer if required Formwork of plastic cells should be made of High Density Polyethylene (HDPE), sheets having thickness ranging from 0.19-0.22MM with sides 150MMx150MM and height as fixed by engineer in charge. To be laid in full width of the carriageway. Iron spikes of about 200MM long are to be used to keep the cell walls taut. Nylon thread or rope may be used to prevent collapse of cells during placement of concrete. Iron spikes to be taken out for use in other place as soon as the concrete is in place. The sub base should be provided with concrete/stone block or brick on edge on either side of the carriageway protecting the sub base with full thickness of the concrete pavement for its confinement and protection. curing of concrete slabs for 14 - days, curing compound ( where specified) and water finishing to lines and grade as per drawing and MoRD Specification of cell filled Concrete Pavement.
Earthwork in excavation for structures as per drawing and MoRD specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil Upto 3 m depth
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and MoRD specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 10 Nominal mix 1:3:6
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and MoRD specifications Clause 802, 803, 1202 & 1203 P.C.C. grade M 20 Nominal mix (1:2:4)
Providing and fixing of Reinforced Ferro cement Drain cover designed for class "AA" loading duly marked on cover with adequate steel reinforcement having thickness 75 mm to 150 mm anti- corrosive bitumen painted M.S. plate Rim and on M.S. lifting hooks admixture like plasticizer bond improving compound shrinkage resistance compound abrasion resistant complete as per approved design etc. for drain Opeining Size 451 to 700 mm Standard Drain Cover Size 1000mm x 800mm x 100mm
Stone masonry work in cement mortar in foundation complete as per drawing and MoRD specifications Clauses 702, 704, 1202 & 1203. Coursed rubble masonry (2nd sort) In 1:4 cement mortar
Providing PCC M-20 architectural coping on the top of wing wall, return wall etc. complete as per drawing and MoRD specification Clauses 615, 710 and 1204.3.11 50 mm thick
Plastering with cement mortar (1:4), 20 mm thick on Stone work.
Providing pressure relief pipes 100 mm dia in bottom slab of box cell on a filter media base of 500 mm x 500 mm as per drawing and MoRD specification Clause 1205.5.7
Providing and laying pitching on slopes laid over prepared filter media as per drawing and MoRD specifications Clause 1302 Stone/Boulder
Providing and laying boulder apron for bed protection with stone boulders of minimum size and weight as per Table 1300.1, no fragment weighing less than 25 kg laid dry complete as per drawing and MoRD specifications Clause 1301
Providing and laying reinforced cement concrete pipe NP4 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. 1000 mm dia
Supply & Planting of shady plants ( Neem, Peepal, Goolar, Jamun, Imli or other specified ) along road side including the following activities:- 1. Preparation of soil including cleaning & removing of unwanted shrubs removal of stones & garbage. 2. Supply of plant at site of two years of age & height more than 1.50 Mtr 3. Supply of dry manure ( Farm yard manure organic ) 4. Supply of Insecticides 5. Digging of pits size 60x60x60 cms. Including removal of stones. Manuring application of insecticides & watering at least 15 liter per plant after planting. 6. Half brick Circular tree guard in second class bricks, internal dia 1.25 meter and height 1.20 meter above ground and 0.20 meter below ground, bottom two courses laid dry and top three courses in cement mortar 1:6 (1Cement : 6 Sand) and the intermediate courses being in dry honey comb masonry, as per design complete.
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and MoRD Specification Clause 801 900 mm equilateral triangle
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and MoRD Specification Clause 801 600 mm equilateral triangle
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and MoRD Specification Clause 801 600 mm circular
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and MoRD Specification Clause 801 600 mm x 450 mm rectangular
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and MoRD Specification Clause 801 900 mm side octagon
Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three plates of Aluminium Composite Materials (ACM), material specifications as per Clause 1701.3.7. The top most plate will be in diamond shape of 600mm x 600 mm size, riveted over welded M.S. angle iron frame of 25 mm x 25mm x 5 mm size on back on edges. The middle plate will be 1200 mm x 150 mm size riveted over welded M.S. angle iron frame of 25mm x 25mm x 5 mm size on back on edges. The main lower most plate will be 1500 mm x 600 mm size, riveted over welded M.S. angle iron frame of 25 mm x 25 mm x 5 mm size. Welding of all the sheets over angle iron frame will be done neatly to have plain surface on one side. The angle iron frames of the lower most plate and the middle plate will be welded to two nos. 75 mm x 75 mm (12 SWG) sheet tubes posts placed at 1125 mm apart centre to centre. The top of the middle plate will be flushed with the top of 75 mm dia medium steel tube posts and these posts will be embedded in cement concrete M15 grade blocks of 450 mm x 450 mm x 600 mm below ground level. The height of bottom of the lower most plate will be 1200 mm from normal ground level and the bottom of middle plate will be 100 mm above the top level of the lower most plate. The lettering and borders, etc. of middle and bottom plate, PMGSY logo on top plate shall be as per clause 1701.4.6 Messages/Borders. All the sections of frame and posts will be painted with primer and two coats of Epoxy paint. The steel tube below ground level will be painted with three coats of Epoxy paint. The design, painting and lettering shall be done as per approved drawing. For warranty and durability the clause 1701.5 and for maintenance the clause 1911 shall be applicable. A reference number along with the month and year of installation should be placed on the back of a sign in a contrasting colour or by stamping in characters not exceeding 50 mm in height as per approved drawing and MoRD Specification Clause 1700
Providing and fixing of PMGSY logo with definition plate (as per MORD design/drawing) 3mm thick plate of Aluminium Composite Materials (ACM), material specifications as per Clause 1701.3.7. The top most plate will be in diamond shape of 600mm x 600 mm size, riveted over welded M.S. angle iron frame of 25 mm x 25mm x 5 mm size on back on edges including orange luminous colour epoxy paint on logo, size of definition plate 900x300mm supported on MS post of square hollow section 75x75x6mm, 3m long .The lettering and borders, etc. of definition plate and PMGSY logo on top plate shall be as per clause 1701.4.6 Messages/Borders. All the sections of frame and posts will be painted with primer and two coats of Epoxy paint. The steel tube below ground level will be painted with three coats of Epoxy paint. The design, painting and lettering shall be done as per approved drawing.Posts will be fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 x 450 x 600 mm, 600 mm below ground level as per approved drawing and MoRD Specification Clause 1700
Providing and Erecting typical Citizen's information Board as per approved drawing & specification of MORD made of Two plates of Aluminium Composite Materials (ACM), material specifications as per Clause 1701.3.7 of size 900 mm x 750 mm size riveted over welded M.S. angle iron frame of 25mm x 25mm x 5 mm size on back on edges. Frame will be welded to two nos. 75 mm x 75 mm (12 SWG) sheet tubes posts placed at 1000 mm apart centre to centre these posts will be embedded in cement concrete M15 grade blocks of 450 mm x 450 mm x 600 mm below ground level. The lettering and borders, etc. of plates shall be as per clause 1701.4.6 Messages/Borders. All the sections of frame and posts will be painted with primer and two coats of Epoxy paint. The steel tube below ground level will be painted with three coats of Epoxy paint. The design, painting and lettering shall be done as per approved drawing and MoRD Specification Clause 1700
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and MoRD Specification Clause 1703 5th Kilometre Stone (precast)
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and MoRD Specification Clause 1703 Ordinary Kilometer Stone (Precast)
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and MoRD Specification Clause 1703 200 m stone (precast)
Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and MoRD Specification Clause 1704
Providing and laying rounded hump type speed breakers for crossing speed 25 km/h as per IRC design including providing and applying bitumen emulsion tack coat, making speed breaker in designed profile with bituminous macadam, providing seal coat type B for sealing the voids and marking chequered pattern with thermoplastic paint complete as per IRC : 99-1988 5.0 meter wide and 10 cm high for heavy truck and bus traffic
Marking Centre Line and stop lines etc. on road as per IRC pattern with thermoplastic paint of approved quality and make with 8% glass beads laid on the road surface at temperature 160" C with a special applicator machine complete with a special applicator machine complete with labour material and traffic diversion arrangements.
Supplying of Cat’s Eye made of aluminium alloy size 75x100x22 mm having 21 biconvex lenses embedded in circular disk of ABS plastic on each side.
Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on RCC Post 100 mm x 100 mm firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 x 450 x 600 mm, 600 mm below ground level as per approved drawing and MoRD Specification Clause 1701 upto 0.9 sqm size board
Providing and Erecting typical Maintenance information Board as per approved drawing & specification of MORD made of Aluminium Composite Materials (ACM), material specifications as per Clause 1701.3.7 of size 900mm x 1500mm stiffend by angle iron 25mmx25mm x 3mm all around the plate & plates fixed on frame of two nos. 75 mm x 75 mm (12 SWG) sheet tubes posts placed at 1000 mm apart centre to centre (vertical post 3050 mm with angle holdfasts and horizontal member 900mm) to be joined by embedded in cement concrete M15 grade blocks of 450 mm x 450 mm x 600 mm below ground level. The lettering and borders, etc. of plates shall be as per clause 1701.4.6 Messages/Borders. All the sections of frame and posts will be painted with primer and two coats of Epoxy paint. The steel tube below ground level will be painted with three coats of Epoxy paint. The design, painting and lettering shall be done as per approved drawing and MoRD Specification Clause 1700
Supply of Hazard Marker made out of 2 mm thick M.S. sheet size 300x300x3 mm framed with angle iron 25x25x3 mm and fixed on channel posts 75x40x6 mm and hold fast at bottom whole body is painted in white stoving enamel and 6 Nos., 5 cm dia reflective sheet on white reflective background with additional border of 1.25 cm all arount it.
Supply of Chevron sign of size 75x60 cm made out of aluminum sheet 2 mm thick with fixing provision on M.S. angle iron post 50x50x6 mm 3 M long screwed with stainless steel nut bolts of 8 M dia, plate is covered by high intensity grade yellow retro-reflective sheeting and black screen printed arrow on Retro Reflective Sheet, complete in all respect. Comp. in all respect duly post painted in alternate band of Black/White synthetic enamel paint & hold fast at bottom
Fixing of sign board having two posts including excavation cement concrete 1:5:10(30X30X60 cms.) and transportation complete of size. : 60x75 cm, 90x60 cm, 75x45 cm, & 60x45 cm.
Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with M-20 grade concrete with HYSD reinforcement conforming to IRC:21 and dowel bars 25 mm dia, 450 mm long at expansion joints filled with pre-moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclosure to MOST circular No. RW/NH - 33022/1/94-DO III dated 24 June 1994 as per dimensions in the approved drawing and at locations directed by the Engineer, all as specified
Annual maintenance charges on prorata basis as per fixed Percentage basis
1st year - 0.68%
2nd year - 0.87%
3rd year - 1.12%
4th year - 1.31%
5th year - 1.52%
M/S DWARKA DAS AGARWAL
shri rishabh construction
M/s HARDAYAL CONSTRUCTIONS AND PROJECTS LLP
M/s Laxmi Nath Infrastructure Pvt Ltd
RAJENDRA SINGH BHAMBOO INFRA PRIVATE LIMITED
M/s Lal Chand Tiwari
M/s Ramesh Kumar Bansal
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .