Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.3 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹23.7 L+₹66,579 (2.89%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹24.3 L+₹1.2 L (5.15%)Rejected-AOC NEAR OLD INDIAN OIL DEPOT JALANDHAR JAMMU BYE PASS ROAD PATHANKOT 145001 PB | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹25.0 L+₹1.9 L (8.29%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹27.3 L+₹4.2 L (18.2%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
18 Sept 2024, 6:00 pmClosed
Garrison Engineer(N) Mamun
Garrison Engineer(N) Mamun Pin-145001
REPAIR / REPLACEMENT OF ELECTRICAL WIRING AND CONNECTED ACCESSORIES, FITTINGS AND FIXTURES UNDER AGE E/M-II OF GE (N) MAMUN
2024_MES_668349_1
GE(N)/M-33/2024-25
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer(N) Mamun
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer(N) Mamun
₹1 L
14 Dec 2024
31 Aug 2024
20 Sept 2024
31 Aug 2024
18 Sept 2024
13 Sept 2024
Amount
Taking down carefully unsv copper/aluminium point wiring (light/fan/Bell/socket or power) complete, including fixture and fittings such as switches, sockets, ceiling rose, lAmp holders, brackets, pendent, regulators, sockets, Bracket /sketch fitting etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floor with cement mortar and finishes to match existing surface complete all as specified and directed.
M & L for point wiring using 3×1.5 sqmm FRLS PVC insulated and unsheathed multistranded copper conductor cable(phase, neutral and earth wire) drawn through and including PVC rigid concealed conduit medium grade of dia not less than 20mm and connected to common earth dolly with 1.6mm thick cadmium plated CI/GI pressed steel sunken boxex and 3mm thick plastic laminated sheet cover fixed with brass screws complete including cutting grooves for concealed wiring for light/fan/exhaust fan point controlled by one 1 way switch complete all as specified and directed. Note:- Conduit shall be fixed on surface/ceiling with necessary saddles where concealed of conduit is not feasible.
All as per Ser item No 2 but for One light point controlled by two 2 way switch.
All as per Ser item No 2 but for One bell/ buzzer point.
All as per Ser item No 2 but for One 5 Amp socket outlet on same board.
All as per Ser item No 2 but for One 5 Amp socket outlet on independent board.
All as per Ser item No 2 but for One 15 Amp socket point with 3x2.5 Sqmm FRLS PVC insulated unsheathed multistranded copper conductor.
M&L for point wiring using 3x1.5 sqmm FRLS PVC insulated and unsheathed multistranded copper conductor cable(phase, neutral and earth wire) drawn through existing PVC conduit and connected to common earth dolly with 1.6mm thick cadmium plated CI/GI pressed steel sunken box and 3 mm thick plastic laminated sheet cover fixed with brass screws complete including cutting grooves for concealed wiring for light/ fan/ exhaust fan point controlled by one 1 way switch complete all as specified and directed.
All as per Ser item No 8 but for One light point controlled by 2 way switch.
All as per Ser item No 8 but for One bell/ buzzer point controlled by one bell push.
All as per Ser item No 8 but for One 5 Amp socket outlet on same board.
All as per Ser item No 8 but for One 5 Amp socket outlet on independent board.
All as per Ser item No 8 but for One 15 Amp socket point with 3x2.5 Sqmm FRLS PVC insulated unsheathed multistranded copper conductor
S&F switch piano flush button single, pole one way, 5 Amp complete all as specified and directed.
S & F switch socket combination 2 in 1, 5 Amp flush type, 240volts, complete all as specified and directed
S & F switch socket combination 5 in 1,3 pin, 15 Amp flush type, 240volts, complete all as specified and directed
S & F in Socket outlet 2 in 1, 3 pin 5Amp, flush type with shutters, 240volts complete all as specified and directed. .
S&F in replacement socket outlet 2-in-1, 3 pin, 15 Amp flush type,240volts complete all as specified and directed.
S&F in switch piano flush type with shutters,240 volts single pole one way 15 Amp complete all as specified and directed.
S&F switch piano flush button single, pole two way, 5 Amp complete all as specified and directed.
S & F in switch bell push, flush type, 5 Amp 230 volt complete all as specified and directed.
S & F ding dong door bell electric suitable for AC 230 volt, single pole complete all as specified and directed.
S&F ceiling rose PVC/ Polycarbonate, insulated body surface bakelite 65mm dia , three terminals complete all as specified and directed.
S & F step type electronic fan regulator flush type socket type on the phenolic laminated sheet etc not less than 100 W complete all as specified and directed
S&F LAmp holder, PVC/Polycarbonate type with back plate complete all as specified and directed.
S&F LED lAmp 15 watts, rated input voltage 220 V AC , 50Hz, rated lumens 1425 lm, CRI 80,lAmp life 15000 hours,rated efficacy 95 lm/w, surge protection 3.0 kV, 3 star rated, complete all as specified and directed.
Taking down carefully unsv copper/aluminium submain wiring of any size including broken steel/PVC conduit and removing materials to store for keeping in safe custody for taking credit complete all as specified and directed.
S&F Sub main wiring with two single core PVC insulated unsheathed multistranded flexible copper conductor cable of size 2X6 sqmm and one single core PVC insulated unsheathed multistranded flexible copper conductor cable of size 1x6 sqmm (green colour) copper cable as earthing lead connecting to main earthing dolly drawn in existing PVC concealed conduit, complete all as specified and directed.
All as per item No 28 here in before, but two run of single core 4 sqmm and one run of 4 sqmm cables as earth continuity conductor all as directed.
S & F in replacement SPN MCB DB 8 way sheet metal enclosures double door 230 V AC, 50 Hz AC with IP 54 and IK 09 rating having fully insulated copper bus bar of rating not less than 100Amps, insulated neutral bar, earth bar and cable ties for cable management including polyuthrene gasket making good the disturbed surface to match with existing wall, painting the plastered surface with same colour complete all as specified and directed.
S & F in replacement Triple pole and neutral DB 4 way sheet metal enclosures double door 415 V AC, 50 Hz AC with IP 54 and IK 09 rating having fully insulated copper bus bar of rating not less than 200Amps, insulated neutral bar, earth bar and cable ties for cable management including polyuthrene gasket making good the disturbed surface to match with existing wall, painting the plastered surface with same colour complete all as specified and directed.
S & F in replacement VTPN DB 4 way sheet metal enclosures double door 415 V AC, 50 Hz AC with IP 54 and IK 09 protection suitable for wall including MCCB 160 Amps, 4P, 16 kA with fixed magnetic and thermal setting of same make as DB and making connection suitable size of aluminium thimbles, making good the disturbed surface to match with existing wall, painting the plastered surface with same colour complete all as specified and directed.
S & F in replacement MCB TPN 40 to 100Amp, 415 volts C curve, 50Hz AC 10kA complete all as specified and directed.
S & F in replacement MCB TP 25 to 63 Amp, 415 volts C curve, 50Hz AC 10kA complete all as specified and directed.
S&F MCB SPN 240V, 50Hz, 10 kA of rating 32 Amp 'C' series all as specified and directed.
S&F MCB SP 240V, 50Hz, 10 kA,of rating 5 to 32 Amp 'C' series all as specified and directed.
S&F in replacement MCCB three pole 125 Amp 415 Volts fixed type with breaking capacity 25 kA complete all as specified and directed.
S&F MCB single pole 240 volts 40 Amps, 10kA (C-series) including taking out existing unserviceable MCB of any make/series etc complete all as specified and directed.
M&L for repair to existing switch board by taking out the old existing ser/unsv switches, sockets, regulators any type and refixing the serviceable switch/sockets after replacement of old unsv/broken Hylem sheet of thickness not less than 3mm of size upto 5"×5" complete all as specified and directed.
Same as per item No 39 above but size 8"×5"
Same as per item No 39 above but size 9"×11"
S&F in replacement concealed GI/CI sheet metal box (16 Guage) incl flush mounting in wall and taking out old rusted sunken box of size upto 7"×4" and making good the disturbed surface of wall/floor with cement mortar 1:4 and finish to match existing surface complete all as specified and directed.
All as per Srl item No 42 but for size 8"x10"
S & F in replacement surface mounted 10 Watt 2 feet box type LED batten as mirror light,with wall mounting arrangement including connecting up with three core twisted flexible copper conductor cable of suitable size in flexible conduit pipe of suitable size from ceiling rose to connector of LED fitting complete all as specified and directed.
S & F in replacement LED Bulk head 10 watt energy efficient wall mounted, pressure die cast aluminium housing & enclosed with poly carbonated cover with all accessories including lAmp complete including connecting up with three core twisted flexible copper conductor cable of suitable size complete all as specified and directed.
S&F in replacement PRIDE PLUS INVERTER BATTEN 20Watt Inverter LED batten with square profile and polycarbonate channel Lithium Ion battery with charging time 8-10 hours and backup time upto 4 hours with Battery capacity 2600mAh with benefits of following :- (i) Battery backup time upto 4 hrs with 3-4 W light output (ii) Better lumens and longer lAmp life (iii) High efficacy and lower power consumption (iv) Delivers high brightness & excellent illumination even in high ceiling areas (v) Extraordinary long life of LED's & high electronic driver (Over 25,000 burning hours) ensure zero maintenance (vi) Over charging protection (vii) Deep discharge protection (viii) battery short circuit protection (ix) Instant light with low running temperatures (x) Operating temperature range -10˚C to +35˚C integral electronic driver (SMPS based constant current supply) with output short circuit protection, Surge protection & other safety test as per IS: 15885 Part 2/Sec 13. all as directed by Engr-in-charge. Make - Havells cat part LHEXACP7FN1W020 equivalent to Crompton/ Bajaj
S & F in replacement of intenso LXS LED Batten 20 watt, of size 3'7" , 6500 K, 230 volts,PF-0.95, CRI-80, life 25000 burning hours, Aluminium housing, wall mounted complete with all accesssories internely pre wired and including connecting up with three core twisted flexible copper conductor cable of suitable size complete all as specified and directed.
S & F in repair recess mounting high lumen LED flat panel 1' X 4' , 36 watt , panel having white powder coated CRCA body high quality PMMA diffuser suitable for ceiling with high power LED white high transmission acrylic cover internally prewired 230V, complete with all accessories such as electronic driver LED strip connector block etc and neccessary fixing arrangement at any height & removing old unsv items complete all as specified and directed
S & F in replacement surface mounted scintilate LED round frameless capacity 18Watt square powder coated PDC aluminium body & high quality LGP & PMMA diffuser separate driver CRI>80, BEAM ANGLE 120 Degree complete all as specified and directed
S & F LED post top fitting 20watt, powder coated aluminium die cast and spun aluminium body with clear opal diffuser suitable for landscape lighting complete all as specified and directed
S & F in replacement recess mounting high lumen LED flat panel 2' X 2' , 36 watt , panel having white powder coated CRCA body with high power LED aluminium front frame with flat white high transmission acrylic cover internally prewired 230V, complete with all accessories such as electronic driver LED strip connector block etc and neccessary fixing arrangement at any height & removing old unsv items complete all as specified and directed
S&F in replacement of LED Building light 60 watt luminaire, made out of pressure die-cast aluminium housing,PC diffuser and integrated electronic driver with high efficiency, with polycarbonate cover, IP65 protection including 32mm bore light grade GI pipe bracket, mounted on wall or roof using clamps, nuts bolts, washers, fastners etc including connecting up with 3 core flexible copper conductor cable in flexible conduit pipe of suitable size complete all as specifed and directed .
Supply and fix electronic meters temper proof LCD display with polycarbonate cover 230 V, 10- 60Amp, accuracy class-I 50Hz, conforming to IS.13779, IP-54, with parameters to show data, time,current reading, load, PF, voltage and KWH complete all as specifed and directed. Make : HPL , L&T, ABB
M & L for earthing complete with G .l earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground ( earth pit not less than 2.25 m deep below GL ) with top edge of the plate not less than 1.5 m below the normal ground level connected galvanized earth lead wire 4.0 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel including necessary excavation & earth work in any type of soil, removing surplus soil to a distance not exc 50 M, including PCC chamber in PCC (1 : 3 : 6), type C-1, using (20 mm graded stone aggregate), with fair finish internal surface with 15mm thick plaster in cm 1:4, funnel, including charcoal dust & common salt & specified including provision of 4mm dia GI wire upto 7.5mtr long protected by 15mm bore light grade pipe and watering pipe shall be 20mm bore medium grade, including all excavation and earth work and connecting the earthing to earthing test point and to main switch board as specified & testing on completion, all as shown in electrical plate No 3 of MES SSR Part -1 (2009) , all as specified and directed. Note : RCC pit cover shall be precast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM weighting not less than 4 kg/Sqm in lieu of CI cover.
S&F in replacement of exhaust fan AC single phase 230V of size 380mm sweep steel body with louver and connecting up including provision of flexible copper wire 3 core of suitable size from ceiling/ PVC connector to exhaust fan all as specified and directed Note : Old exhaust fan shall be deposited in the store of Engineer in charge.
S & F in replacement of exhaust fan AC single phase 230V of size 450mm sweep heavy duty steel body with louver and connecting up including provision of flexible copper wire 3 core of suitable size from ceiling/ PVC connector to exhaust fan all as specified and directed. Note : Old exhaust fan shall be deposited in the store of Engineer in charge.
Taking down carefully serviceable single phase energy meters from meter box after carefully disconnecting the electrical connections and keeping aside for refixing and dismantling old/unsv meter box and removing to store for keeping in safe custody for taking credit and making good to disturbed surfaces of wall, floor, etc complete all as specified.
S&F in replacement in replacement sheet moulded compound (SMC) meter box, fire retardant type of size not less than 600×500×150mm to enclose 04 Nos single phase electric meters with hinged type front operated door having transparent acrylic sheet & proper locking arrangement and flush mounting in wall refixing the serviceable electric meters dismantled under item No 57, making electric connections including cleaning of disturbed area and making good the disturbed surface and matching with existing specification complete all as specified and directed
S&F in replacement in replacement sheet moulded compound (SMC) meter box fire retardant type of size not less than 700×480×150mm to enclose 06 Nos single phase electric meters with hinged type front operated door having transparent acrylic sheet & proper locking arrangement and flush mounting in wall incl refixing the serviceable electric meters dismantled under item No 57, making electric connections including cleaning of disturbed area and making good the disturbed surface and matching with existing specification complete all as specified and directed
S&F outdoor sunflower shape solar LED light, waterproof , IP 65, 30 LED 3 sunflower in one plant for garden, materials abs, stainless steel, automatic ON/OFF complete all as specified and directed
S&F outdoor type Jellyfish shape LED solar light,waterproof, Multicolour LED solar string light, automatic ON/OFF complete all as specified and directed
Deduct : Total amount of SCH 'A' SECTION-II (SCH OF CREDIT) Rs. 77,382.00 to be deducted from Schedule ‘A’ (BOQ) to arrive at the Contract Sum.
KONARK ENTERPRISES (BID ID -3099214)
M/S ANSHUL ENTERPRISES (BID ID -3099049)
SWAMI CONSTRUCTIONS (BID ID -3099336)
bhatia construction (BID ID -3098623)
dadwal engineers (BID ID -3098981)
kailu construction co (BID ID -3099046)
AGGARWAL ASSOCIATES (BID ID -3098439)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .