Loading…
Loading…
Tender Value
₹41.2 L
EMD Value
₹41,203
Closing Date
8 Sept 2026, 2:00 pm6d left
Addl CEO
Zilla Parishad Chh. Sambhajinagar
REPAIRS TO GIRLS Z.P. PSB AND OTHER ALLIED WORKS AT CHAWNI, TQ. AND DIST.CHHATRAPATI SAMBHAJINAGAR.
2026_AURAN_1331104_11
ZPCHSN/Works/SLR/2059/688/11
Open Tender
Civil Works
Percentage
180 days
Tq. and Dist. Chh. Sambhajinagar
Please refer Tender documents as per NIT
2 documents required · 2 mandatory
₹1,180
₹41,203
24 Aug 2026
24 Aug 2026
9 Sept 2026
24 Aug 2026
8 Sept 2026
24 Aug 2026
REMOVING THE EXISTING CEMENT PLASTER of any thickness without causing dust nuisance and stacking the debris upto a distance of 50 metres or spreading in the compound and cleaning the site etc. complete.
REMOVING CEMENT TILES, OR MARBLE OR POLISHED SHAHABAD FLOOR OR DADO without bed concrete including stacking the materials as directed with all leads, lifts etc. complete
REMOVING W.C. PANS including disconnecting the sanitary and water supply connections, removing and breaking flooring and bed con-crete around pan removing the same carefully and stacking the serviceable materials as adn where directed including throwing the unserviceable materiasls out side etc. carefully and throwing out the refusal outside etc. complete.
REMOVING DOORS AND WINDOWS WITH FRAMES and stacking the materials as directed with all leads, lifts etc. complete.
Dismantling flat wooden or A.C. Sheet ceiling with frame work including stacking the materials as directed with all leads, lifts etc. complete.
Dismantling stone masonry in lime or cement mortar including stacking the materils as directed with all leads, lifts etc.
REMOVING G.I. OR A.C. SHEET ROOFING including purlins, principal rafters etc. including sorting serviceable and unserviceable materials, stacking the same as and where directed in the compound including scaffolding etc. complete.
EXCAVATION FOR FOUNDATION IN EARTH, SOIL OF ALL TYPES, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (LIFT UPTO 1.5 M.) BY MECHANICAL Means
EXCAVATION FOR ROADWAY IN EARTH, SOIL OF ALL SORTS, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50m. and spreading for embankment or stacking as directed.
Providing SOLING USING 80 MM SIZE TRAP METAL IN 15 CM. LAYER including filling voids with Crushed sand/grit, ramming, watering etc. complete.
Providing and laying Cast in situ/Ready Mix CEMENT CONCRETE IN M-10 of trap/ granite/ quartzite/ gneiss metal FOR FOUNDATION AND BEDDING including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying in situ /Ready Mix CEMENT CONCRETE M-20 of trap / granite /quartzite/ gneiss metal FOR R.C.C. WORK IN FOUNDATIONS LIKE RAFT, STRIP FOUNDATIONS, GRILLAGE AND FOOTINGS of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix CEMENT CONCRETE M-20 of trap / granite /quartzite/ gneiss metal FOR R.C.C. COLUMNS as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix CEMENT CONCRETE M-20 of trap / granite/quartzite/ gneiss metal FOR R.C.C. BEAMS AND LINTELS as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and fixing in position TMT - FE - 500 BAR REINFORCEMENT OF VARIOUS DIAMETERS for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.
Providing and fabricating STRUCTURAL STEEL WORK IN ROLLED SECTIONS LIKE JOISTS, CHANNELS, ANGLES, TEES ETC. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete.
Providing and fixing CORRUGATED GALVANISED IRON SHEETS OF 0.63MM THICK (24 B.W.G.) FOR ROOFING without wind tiles including fastening with galvanised iron screws and bolts, lead and bitumen washers as per drawing etc. complete.(Weight of 5.5 Kilogram/sq.m.).
Providing second class BURNT BRICK MASONRY with conventional/ I.S. type bricks in cement mortar 1:6 IN SUPERSTRUCTURE including striking joints, raking out joints, watering and scaffolding etc. Complete
Providing and laying Cast in situ/Ready Mix CEMENT CONCRETE M-15 of trap/ granite/quartzite/gneiss metal FOR COPING TO PLINTH OR PARAPET, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Crushed sand VSI Grade)
Providing internal CEMENT PLASTER 6 mm thick in a single coat in cement mortar 1:4 without neeru finish to concrete surface in all positions including scaffolding and curing etc. complete.
Providing internal CEMENT PLASTER 20MM THICK in Single coats in cement mortar 1:4 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc.complete.
Providing and fixing heavy duty inter locking CONCRETE COLOURED PAVING BLOCKS OF 60 MM THICKNESS of having a strength of 300 Kilogram/Sq.cm. of approved quality and shape on a bed of crushed sand of 25 to 30 mm thick including skirting joints and cleaning etc. complete
Providing and laying Cast in situ/Ready Mix CEMENT CONCRETE IN M15 of trap/ granite/quartzite/gneiss metal FOR FOUNDATION AND BEDDING / STEPS including steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.),with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying VITRIFIED MATT FININSH TILES having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern FOR FLOORING in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete.
Providing and laying ANTISKID CERAMIC TILES of approved quality of size 30 cm x 30 cm and confirming to IS 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete.
Providing and laying CERAMIC TILES of having size 30 cm. x 30 cm. and confirming to corresponding I.S. FOR DADO AND SKIRTING in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete.
Providing and fixing M40 GRADE THICK VIBRATED PULL CAST OR SIMILAR TYPE CONCRETE FRAME with chamfer conforming to I.S. 65241983 having 6 mm dia. bars 3 Nos. And stirrups @250 mm c/c and fixing in wall with 6 Nos of hold fast of 12 mm dia bars 500 mm long including primer and oil painting etc, complete) FRAME SIZE 60 MM X 100 MM .
Providing and fixing FIBER GLASS REINFORCED POLYSTER DOOR SHUTTER 30 MM THICK as per IS 14856 (2000) (Reaffirmed 2006) without ventilator including chromium plated fixtures and fastening with chromium plated handles on both sides, etc complete
Providing and fixing SOLID CORE FLUSH DOOR SHUTTER IN SINGLE LEAF 32 MM THICK decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete.
Providing and fixing STEEL WINDOW C.R.C. SHEET as per I.S. 1513 : 1986. gauge sect. 65 x 40 x 25 mm shutter single sheet of 24 gauge single leaf joined by fusion welding at appropriate points with vertical grooves of 15 mm wide and 15 mm deep at a distance of 45 mm. The first and last rib should be 60 mm away from vertical edge of the shutter. the shutter shall be welded, with angle to from the periphery of the shutter. At the center of the frame there shall be angle welded to bifurcate the frame into segments with two leaf shutter square 12 mm square guard bars at 120 mm center with all accessories
Providing and fixing in position. (as per I.S.1868 / 1982) ALUMINIUM SLIDING WINDOW OF TWO TRACKS with rectangular pipe having overall dimension ?63.50 x 38.10 x 1.02 mm at weight 0.547 Kilogram/One Running Metre. and window frame bottom track section 61.85 x 31.75 x 1.20 mm at weight 0.695 Kilogram/One Running Metre. Top and side track section 61.85 x 31.75 x 1.30 mm at weight 0.659 Kilogram/One Running Metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/One Running Metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/One Running Metre. And handle section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/One Running Metre. and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass with all required screws and nuts etc, complete. WITH POWDER COATING WITHOUT BOX
Providing and fixing 50 MM. DIA. MEDIUM CLASS G.I.PIPE GATE with wicket gate of approved drawing with all fixtures and fittings in two leaves with strong hold fast embedded in c.c. block at top and bottom with locking arrangement including cutting, bending, making holes and with one coat of primer etc. complete.
REPLACEMENT OF DAMAGED ALLUMINIUM BUTT HINGES of 125 mm of approved quality and make to door shutter including removing existing the same in original position making proper adjustment for smooth operation etc. complete as per sample approved by Engineer incharge.
REPLACEMENT OF DAMAGED ALDROP 300 MM CHROMIUM PLATED of approved quality and make to door shutter including removing existing the same in original position making proper adjustment for smooth operation etc. complete as per sample approved by Engineer in-charge.
REPLACEMENT OF DAMAGED TOWER BOLT 300 mm Chromium plated of approved quality and make to door/window shutter including removing existing the same in original position making proper adjustment for smooth operation etc. complete as per sample approved by Engineer in-charge.
REPLACEMENT OF DAMAGED ALLUMINIUM HANDLE 125 mm of approved quality and make to door/window shutter including removing existing the same in original position making proper adjustment for smooth operation etc. complete as per sample approved by Engineer in-charge.
Providing and fixing H.D.P CONTAINER ONE PIECE MOULDED WATER TANK MADE OUT OF HIGH DENSITY POLYTHYLER and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet,outlet overflow pipe inclusive of all tanks CAPACITY BETWEEN 200 TO 1000 LITERS
Providing and fixing on WALLS/ CEILING/ FLOOR 15 MM DIA. UPVC PIPE with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and fixing on WALLS/ CEILING/ FLOOR 25 MM DIA. UPVC PIPE with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and fixing 15 MM DIAMETER PVC AQUA KRAFT TYPE OF APPROVED MAKE SUPER BIB TAP with flange including all accessories etc complete
Providing and constructing BRICK MASONRY INSPECTION CHAMBER 60CM X 45CM X 90CM including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140 Kilogramwith frame etc complete.
Providing and fixing COLOURED GLAZED EARTHENWARE WASH HAND BASIN OF 45 CM X 30 CM SIZE including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including P.V.C. waste pipe and trap up to the outside face of the wall. Making good the damaged surface, testing etc. complete.
Providing and fixing ORISSA TYPE WHITE GLAZED EARTHENWARE 575 MM WATER CLOSET PAN including S trap with earthenware foot rests, cast iron soil and vent pipe upto outside face of the wall 1:2:4 brick bat lime concrete bedding without flushing tank and its accessories etc. complete.
Providing and fixing 15 CM RIGID PVC NAHANI TRAP INCLUDING PVC GRATING ,bend,connectingpiece of UPVC pipe up to the outside face of wall ,making the good damaged surface and testing etc. complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use)
Providing and constructing 75 MM. THICK MODIFIED PENETRATION MACADAM (MPM) road surface including all materials, preparing the existing road surface, spreading 40 mm. stone metal layers 30% CRUSHER BROKEN METAL + 70% HAND BROKEN (by breaking rubble obtained by blasting) heating and spraying the bitumen of specified grade @ 2 Kg/sqm, spreading 12 mm.size chips compacting with three wheel static roller having weight 8 to 10 MT. to achive the desired degree of compaction as per Technical Specification Clause 506 etc. complete. INCLUDING PICKING OF EXISTING WBM SURFACE. (VG-30 bulk bitumen rates are considered to arrive at rates)
Providing and applying TACK COAT on the prepared surface heating by fames in Boiler and spraying bitumen with sprayer on Dry / Hungry B.T. surface 3 kg/10 sqm. (VG-30 bulk bitumen rates are considered to arrive at rates)
OPEN GRADED PREMIX SURFACING- Providing and Laying OGC 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates premixed with bituminous binder transported to site with VTS , laid over a previously prepared surface, finished to the required grade, level, alignment, and rolling to achieve the desired compaction but excluding prime / tack and Seal coat. For Bitumen of specified grade--USING drum mix type hot mix plant with SCADA, Paver and Vibratory roller ( OVER MPM SURFACE) (VG-30 bulk bitumen rates are considered to arrive at rates)
PROVIDING BITUMINOUS TYPE A LIQUID SEAL COAT ON BITUMINOUS SURFACE including supplying all materials and bitumen of specified grade preparing existing road surface, heating and applying bitumen @ 0.98 KgSqm. by mechanical means, spreading chips and rolling, by static roller having weight 8 to 10 MT. etc. complete. (VG-30 bulk bitumen rates are considered to arrive at rates)
Providing and fixing in position Gypsum board false ceiling with 12.5 mm thick Gypsum boards, screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete.
Providing WATER PROOFING TREATMENT as per IS : 1346-1966 to generally inaccessible sloping Reinforced Cement Concrete TERRACE SLAB WITH BITUMEN FELTS in all positions in five course, consisting of applying cold bitumen primer coat at the rate of 2.5 litre per 10 One Square Metre., hot bitumen layer at the rate of 14.50Kilogramper 10 One Square Metre. and over the same layer of bitumen felt of type III grade (I) as per IS: 1332-1965 across the slope with 10 cm overlap commencing at lowest level and again applying hot bitumen course at the rate of 14.50Kilogramper 10 Square Metre. and finally spreading over it grit at the rate of 14.50Kilogramper 10 Square Metre. including all lifts, leads and scaffolding whenever necessary complete as directed with four years' guarantee on requisite stamp paper etc. complete.
Providing and applying PLASTIC EMULSION PAINT of approved quality, colour and shade to old and new surfaces IN TWO COATS including scaffolding, preparing the surface. (excluding the primer coat)etc. complete.
Providing and applying TWO COATS OF EXTERIOR ACRAYLIC EMULSION PAINT confirming to corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface, applying primer coat ,scaffolding if necessary , and watering the surface for two days etc complete.
Providing and applying TWO COATS OF SYNTHETIC ENAMEL PAINT of approved colour to new /old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete.
SPECIFICATION OF WORKS
REMOVING THE EXISTING CEMENT PLASTER of any thickness without causing dust nuisance and stacking the debris upto a distance of 50 metres or spreading in the compound and cleaning the site etc. complete.
REMOVING CEMENT TILES, OR MARBLE OR POLISHED SHAHABAD FLOOR OR DADO without bed concrete including stacking the materials as directed with all leads, lifts etc. complete
REMOVING W.C. PANS including disconnecting the sanitary and water supply connections, removing and breaking flooring and bed con-crete around pan removing the same carefully and stacking the serviceable materials as adn where directed including throwing the unserviceable materiasls out side etc. carefully and throwing out the refusal outside etc. complete.
REMOVING DOORS AND WINDOWS WITH FRAMES and stacking the materials as directed with all leads, lifts etc. complete.
Dismantling flat wooden or A.C. Sheet ceiling with frame work including stacking the materials as directed with all leads, lifts etc. complete.
Dismantling stone masonry in lime or cement mortar including stacking the materils as directed with all leads, lifts etc.
REMOVING G.I. OR A.C. SHEET ROOFING including purlins, principal rafters etc. including sorting serviceable and unserviceable materials, stacking the same as and where directed in the compound including scaffolding etc. complete.
EXCAVATION FOR FOUNDATION IN EARTH, SOIL OF ALL TYPES, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (LIFT UPTO 1.5 M.) BY MECHANICAL Means
EXCAVATION FOR ROADWAY IN EARTH, SOIL OF ALL SORTS, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50m. and spreading for embankment or stacking as directed.
Providing SOLING USING 80 MM SIZE TRAP METAL IN 15 CM. LAYER including filling voids with Crushed sand/grit, ramming, watering etc. complete.
Providing and laying Cast in situ/Ready Mix CEMENT CONCRETE IN M-10 of trap/ granite/ quartzite/ gneiss metal FOR FOUNDATION AND BEDDING including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying in situ /Ready Mix CEMENT CONCRETE M-20 of trap / granite /quartzite/ gneiss metal FOR R.C.C. WORK IN FOUNDATIONS LIKE RAFT, STRIP FOUNDATIONS, GRILLAGE AND FOOTINGS of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix CEMENT CONCRETE M-20 of trap / granite /quartzite/ gneiss metal FOR R.C.C. COLUMNS as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix CEMENT CONCRETE M-20 of trap / granite/quartzite/ gneiss metal FOR R.C.C. BEAMS AND LINTELS as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and fixing in position TMT - FE - 500 BAR REINFORCEMENT OF VARIOUS DIAMETERS for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.
Providing and fabricating STRUCTURAL STEEL WORK IN ROLLED SECTIONS LIKE JOISTS, CHANNELS, ANGLES, TEES ETC. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete.
Providing and fixing CORRUGATED GALVANISED IRON SHEETS OF 0.63MM THICK (24 B.W.G.) FOR ROOFING without wind tiles including fastening with galvanised iron screws and bolts, lead and bitumen washers as per drawing etc. complete.(Weight of 5.5 Kilogram/sq.m.).
Providing second class BURNT BRICK MASONRY with conventional/ I.S. type bricks in cement mortar 1:6 IN SUPERSTRUCTURE including striking joints, raking out joints, watering and scaffolding etc. Complete
Providing and laying Cast in situ/Ready Mix CEMENT CONCRETE M-15 of trap/ granite/quartzite/gneiss metal FOR COPING TO PLINTH OR PARAPET, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Crushed sand VSI Grade)
Providing internal CEMENT PLASTER 6 mm thick in a single coat in cement mortar 1:4 without neeru finish to concrete surface in all positions including scaffolding and curing etc. complete.
Providing internal CEMENT PLASTER 20MM THICK in Single coats in cement mortar 1:4 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc.complete.
Providing and fixing heavy duty inter locking CONCRETE COLOURED PAVING BLOCKS OF 60 MM THICKNESS of having a strength of 300 Kilogram/Sq.cm. of approved quality and shape on a bed of crushed sand of 25 to 30 mm thick including skirting joints and cleaning etc. complete
Providing and laying Cast in situ/Ready Mix CEMENT CONCRETE IN M15 of trap/ granite/quartzite/gneiss metal FOR FOUNDATION AND BEDDING / STEPS including steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.),with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying VITRIFIED MATT FININSH TILES having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern FOR FLOORING in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete.
Providing and laying ANTISKID CERAMIC TILES of approved quality of size 30 cm x 30 cm and confirming to IS 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete.
Providing and laying CERAMIC TILES of having size 30 cm. x 30 cm. and confirming to corresponding I.S. FOR DADO AND SKIRTING in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete.
Providing and fixing M40 GRADE THICK VIBRATED PULL CAST OR SIMILAR TYPE CONCRETE FRAME with chamfer conforming to I.S. 65241983 having 6 mm dia. bars 3 Nos. And stirrups @250 mm c/c and fixing in wall with 6 Nos of hold fast of 12 mm dia bars 500 mm long including primer and oil painting etc, complete) FRAME SIZE 60 MM X 100 MM .
Providing and fixing FIBER GLASS REINFORCED POLYSTER DOOR SHUTTER 30 MM THICK as per IS 14856 (2000) (Reaffirmed 2006) without ventilator including chromium plated fixtures and fastening with chromium plated handles on both sides, etc complete
Providing and fixing SOLID CORE FLUSH DOOR SHUTTER IN SINGLE LEAF 32 MM THICK decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete.
Providing and fixing STEEL WINDOW C.R.C. SHEET as per I.S. 1513 : 1986. gauge sect. 65 x 40 x 25 mm shutter single sheet of 24 gauge single leaf joined by fusion welding at appropriate points with vertical grooves of 15 mm wide and 15 mm deep at a distance of 45 mm. The first and last rib should be 60 mm away from vertical edge of the shutter. the shutter shall be welded, with angle to from the periphery of the shutter. At the center of the frame there shall be angle welded to bifurcate the frame into segments with two leaf shutter square 12 mm square guard bars at 120 mm center with all accessories
Providing and fixing in position. (as per I.S.1868 / 1982) ALUMINIUM SLIDING WINDOW OF TWO TRACKS with rectangular pipe having overall dimension ?63.50 x 38.10 x 1.02 mm at weight 0.547 Kilogram/One Running Metre. and window frame bottom track section 61.85 x 31.75 x 1.20 mm at weight 0.695 Kilogram/One Running Metre. Top and side track section 61.85 x 31.75 x 1.30 mm at weight 0.659 Kilogram/One Running Metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/One Running Metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/One Running Metre. And handle section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/One Running Metre. and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass with all required screws and nuts etc, complete. WITH POWDER COATING WITHOUT BOX
Providing and fixing 50 MM. DIA. MEDIUM CLASS G.I.PIPE GATE with wicket gate of approved drawing with all fixtures and fittings in two leaves with strong hold fast embedded in c.c. block at top and bottom with locking arrangement including cutting, bending, making holes and with one coat of primer etc. complete.
REPLACEMENT OF DAMAGED ALLUMINIUM BUTT HINGES of 125 mm of approved quality and make to door shutter including removing existing the same in original position making proper adjustment for smooth operation etc. complete as per sample approved by Engineer incharge.
REPLACEMENT OF DAMAGED ALDROP 300 MM CHROMIUM PLATED of approved quality and make to door shutter including removing existing the same in original position making proper adjustment for smooth operation etc. complete as per sample approved by Engineer in-charge.
REPLACEMENT OF DAMAGED TOWER BOLT 300 mm Chromium plated of approved quality and make to door/window shutter including removing existing the same in original position making proper adjustment for smooth operation etc. complete as per sample approved by Engineer in-charge.
REPLACEMENT OF DAMAGED ALLUMINIUM HANDLE 125 mm of approved quality and make to door/window shutter including removing existing the same in original position making proper adjustment for smooth operation etc. complete as per sample approved by Engineer in-charge.
Providing and fixing H.D.P CONTAINER ONE PIECE MOULDED WATER TANK MADE OUT OF HIGH DENSITY POLYTHYLER and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet,outlet overflow pipe inclusive of all tanks CAPACITY BETWEEN 200 TO 1000 LITERS
Providing and fixing on WALLS/ CEILING/ FLOOR 15 MM DIA. UPVC PIPE with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and fixing on WALLS/ CEILING/ FLOOR 25 MM DIA. UPVC PIPE with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and fixing 15 MM DIAMETER PVC AQUA KRAFT TYPE OF APPROVED MAKE SUPER BIB TAP with flange including all accessories etc complete
Providing and constructing BRICK MASONRY INSPECTION CHAMBER 60CM X 45CM X 90CM including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140 Kilogramwith frame etc complete.
Providing and fixing COLOURED GLAZED EARTHENWARE WASH HAND BASIN OF 45 CM X 30 CM SIZE including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including P.V.C. waste pipe and trap up to the outside face of the wall. Making good the damaged surface, testing etc. complete.
Providing and fixing ORISSA TYPE WHITE GLAZED EARTHENWARE 575 MM WATER CLOSET PAN including S trap with earthenware foot rests, cast iron soil and vent pipe upto outside face of the wall 1:2:4 brick bat lime concrete bedding without flushing tank and its accessories etc. complete.
Providing and fixing 15 CM RIGID PVC NAHANI TRAP INCLUDING PVC GRATING ,bend,connectingpiece of UPVC pipe up to the outside face of wall ,making the good damaged surface and testing etc. complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use)
Providing and constructing 75 MM. THICK MODIFIED PENETRATION MACADAM (MPM) road surface including all materials, preparing the existing road surface, spreading 40 mm. stone metal layers 30% CRUSHER BROKEN METAL + 70% HAND BROKEN (by breaking rubble obtained by blasting) heating and spraying the bitumen of specified grade @ 2 Kg/sqm, spreading 12 mm.size chips compacting with three wheel static roller having weight 8 to 10 MT. to achive the desired degree of compaction as per Technical Specification Clause 506 etc. complete. INCLUDING PICKING OF EXISTING WBM SURFACE. (VG-30 bulk bitumen rates are considered to arrive at rates)
Providing and applying TACK COAT on the prepared surface heating by fames in Boiler and spraying bitumen with sprayer on Dry / Hungry B.T. surface 3 kg/10 sqm. (VG-30 bulk bitumen rates are considered to arrive at rates)
OPEN GRADED PREMIX SURFACING- Providing and Laying OGC 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates premixed with bituminous binder transported to site with VTS , laid over a previously prepared surface, finished to the required grade, level, alignment, and rolling to achieve the desired compaction but excluding prime / tack and Seal coat. For Bitumen of specified grade--USING drum mix type hot mix plant with SCADA, Paver and Vibratory roller ( OVER MPM SURFACE) (VG-30 bulk bitumen rates are considered to arrive at rates)
PROVIDING BITUMINOUS TYPE A LIQUID SEAL COAT ON BITUMINOUS SURFACE including supplying all materials and bitumen of specified grade preparing existing road surface, heating and applying bitumen @ 0.98 KgSqm. by mechanical means, spreading chips and rolling, by static roller having weight 8 to 10 MT. etc. complete. (VG-30 bulk bitumen rates are considered to arrive at rates)
Providing and fixing in position Gypsum board false ceiling with 12.5 mm thick Gypsum boards, screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete.
Providing WATER PROOFING TREATMENT as per IS : 1346-1966 to generally inaccessible sloping Reinforced Cement Concrete TERRACE SLAB WITH BITUMEN FELTS in all positions in five course, consisting of applying cold bitumen primer coat at the rate of 2.5 litre per 10 One Square Metre., hot bitumen layer at the rate of 14.50Kilogramper 10 One Square Metre. and over the same layer of bitumen felt of type III grade (I) as per IS: 1332-1965 across the slope with 10 cm overlap commencing at lowest level and again applying hot bitumen course at the rate of 14.50Kilogramper 10 Square Metre. and finally spreading over it grit at the rate of 14.50Kilogramper 10 Square Metre. including all lifts, leads and scaffolding whenever necessary complete as directed with four years' guarantee on requisite stamp paper etc. complete.
Providing and applying PLASTIC EMULSION PAINT of approved quality, colour and shade to old and new surfaces IN TWO COATS including scaffolding, preparing the surface. (excluding the primer coat)etc. complete.
Providing and applying TWO COATS OF EXTERIOR ACRAYLIC EMULSION PAINT confirming to corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface, applying primer coat ,scaffolding if necessary , and watering the surface for two days etc complete.
Providing and applying TWO COATS OF SYNTHETIC ENAMEL PAINT of approved colour to new /old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
NoBlackListedDeclaration.pdf
PDF • 0.54 MB
SelfDeclarationAffidavitFormat.pdf
PDF • 0.02 MB
DECLERATINFORMAT.pdf
PDF • 0.10 MB
Tendernotice_1.pdf
PDF • 10.28 MB
BOQ_2278342.xls
BOQ • 0.42 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].