Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical No EMD or Fee received |
Tender Value
₹22 L
EMD Value
₹44,000
Closing Date
10 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CEO SSMM Mandfiya Chittorgarh
Office of the CEO SSMM Mandfiya Chittorgarh
Supply, Installation, Testing and Commissioning of Air Washer Units at Shree Sanwariya Ji Temple at Mandfiya Distt.- Chittorgarh (Raj.)
2022_SANWA_303082_1
E NIT 03/22-23 SSMM Mandfiya Chittorgarh
Open Tender
Electrical Works
Percentage
90 days
Chittorgarh
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
1000 CEO SSMM Mandfiya 500 MD RISL Jaipur
₹44,000
15 Nov 2022
28 Oct 2022
11 Nov 2022
28 Oct 2022
10 Nov 2022
28 Oct 2022
Amount
Providing & Fixing of factory fabricated Air-washer comprising of DIDW GI centrifugal forward curve fan (Make : Nicotra/Kruger/Humidin), complete with base frame, casing made out of 16G galvanised sheet duly powder coated having flanged and bolted panels , wet section & tank shall be made of 2 mm thick SS sheet. The Air-washer shall be complete with celdec pad of depth 200 mm & face velocity across the celdec pad shall be limited to 500 FPM. The complete Air-washer shall be complete with motor (Make : Bharat Bijlee/Havells/crompton), belt drive package, GI B Class interconnecting piping, AL wire mesh box type 90 % down to 10 micron filters, float valve, quickfill, overflow and drain connections, etc. & of the following capacities. Airwasher Make: Edgetech/Ravi Aircon(Revo)/Zeco
Providing and fixing pumps of Single Phase 1HP with 6m head for lifting water from tank of air washer to tray of pads for wetting the celdec pads. (Make: Kirloskar/Crompton)
Ball Valves
Providing & Fixing of Ball Valves 25mm dia (Make: Castle/Zoloto/LP/Kartar/Honeywell/RB)
Y Strainer Valves
Providing & Fixing of Y Strainer Valves 25mm dia(Make: Castle/Zoloto/LP/Kartar/Honeywell/RB)
Providing & Fixing of site fabricated ducting made from aluminium sheet and as per approved drawings & designs including the cost of hangers, supports , angle , fasteners , closed cell neoprene gasket T&P etc. as required of following thickness. All as per pre approved by Engineer in charge.
P & F of Fire retardant flexible canvass connection with Al frame ,Gasket Nut Bolts for air cooling Plants etc as required. All as per pre approved by Engineer in charge.
Supply & fixing of external thermal closed-cell Nitrile rubber Insulation material with low thermal conductivity in form of sheet on duct including cost of adhesive, tape complete as required. All as per pre approved by Engineer in charge. (Make: Accoflex/Armaflex / Superlon / Aflex / Kflex./Supreme)
13mm thick with 26 SWGAluminium Cladding
Providing & Fixing of Star Delta Starter for Air washers with self illuminated Push buttons for ON &OFF,Amperemeter, Voltmeter, MCB, contactors, timer, single phase preventor and O/L relays alongwith separate MCB, contacor& O/L Relay of required rating for pump. (The incoming supply to starter with double earthing to be provided by bidder)
Providing & Laying P.V.C. / XLPE insulated &P.V.C. sheathed Armored Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with electrolytic aluminium conductor confirming, round / flat strip armouring of cables including testing etc. as required of following size. (Make: Polycab/Worldcab/JMP/Havells/RR) (From Starter to Motor, The incoming supply to starter with double earthing to be provided by bidder)
Providing & Laying P.V.C. / XLPE insulated &P.V.C. sheathed Un-armoured Copper cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with electrolytic grade Copper made of copper rods confirming to IS 613-1964 including testing etc. as required of following size. (Make: Polycab/kei/Havells/RR)
Supplying and making one end termination with heavy duty brass single compression gland SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Compression Nut, heavy duty aluminium lugs duly crimped with crimping tool, PVC tape of following size of PVC insulated & PVC sheathed/ XLPEaluminium conductor cable of 1100 volt grade as required.
3.5 x 25.0 sq.mm
Supply, Fabricating & installing following sizes of perforated Hot dipped Galvanized iron cable tray including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with GI suspenders including GI bolts & nuts , fastners, supports etc. as required.
225mm x 50mm x 1.6mm
S &Laying of earth wire 8 SWG GI Wire from Airwasher Starter to Airwasher Motor making connection etc. as required.
Dismantling of existing Air Washers with removal of insulation and duct connection with canvas to be done at site and unloading the system alongwith shifting the dismantled parts at desired location within the mandir premises as per the instructions of Engineer in Charge.
Tests of specified items below must be done in Government approved OEM's authorised Labs / outsource from government approved any authorised Lab by agency & no extra payment shall be made for below mentioned tests & procedures at all :-↓(a)Thickness of CRCA sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting, pickling in acid bath, phosphatising& shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel. The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c) Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only. All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar / Flexible wire for Interconnection between Main busbar and Switchgear is to be Paid Extra )(d)Wiring between components within switchgear and Incoming / outgoing cable shall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram.
Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulator with standard short circuit withstand capacity , high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work ,
Electrolytic grade (Cu-ETP) Tin Coated annealed copper bus bars IACS 100% grade
Providing & Fixing of 110/220 V, unibody LED Indicating lamp IEC 60947 with integral circuit, IP 65 above panel & IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 29 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDC including connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work
Red/yellow/Green colour
SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent& heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 690 V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections etc. as required.OEM shall have submit NABL / CPRI / ERDAaccrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work4 pole MCCB With Microprocessor based release with adjustable O/L & S/C setting with Inbuilt Instantaneous and Ground fault Protection.
Upto 160 Amp , 50 kA
250 Amp , 50 kA
400 Amp , 50 kA
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .