Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.7 LAccepted-AOC | ₹21.7 L Quoted ₹21.9 L | L1 | Accepted-AOC Lowest |
| 2 | L2₹26.1 L+₹4.2 L (19.4%)Rejected-Finance | ₹26.1 L+₹4.2 L (19.4%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹27.1 L+₹5.2 L (23.8%)Rejected-Finance | ₹27.1 L+₹5.2 L (23.8%) | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹28.0 L+₹6.1 L (27.9%)Rejected-Finance | ₹28.0 L+₹6.1 L (27.9%) | L4 | Rejected-Finance Other than lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
16 Sept 2023, 6:00 pmClosed
GE Gurdaspur
Garrison Engineer, Gurdaspur (Tibri)
Repair to sewage line, septic tanks, soakage wells, drains, culverts in Md accn under AGE B/R-II at Tibri Mil Stn, GE Gurdaspur.
2023_MES_614590_1
GE GSR-44/2023-2024
Open Tender
Civil Works
Item Rate
300 days
GE Gurdaspur
As per Tender Documents
8 documents required · 8 mandatory
₹500
GE Gurdaspur
₹80,000
17 Oct 2023
19 Aug 2023
23 Sept 2023
19 Aug 2023
16 Sept 2023
4 Sept 2023
Amount
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in soft/loose soil.
Excavating in trenches, n exc 1.5 m wide, exc 1.5 m and n exc 3.00m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 3.00 m in depth and getting out in soft/loose soil.
Returning filling in the soil including spreading, levelling, watering and well ramming in layer n.exc 25cm thick each layer complete all as specified and directed.
Removing excavated soil to a distance not exc 50m away and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed.
Demolition and breaking up 150 mm drain pipes (SGSW/AC/reinforced concrete) set in cement mortar and taking out from trenches.
Demolition and breaking up 200 mm drain pipes (SGSW/AC/reinforced concrete) set in cement mortar and taking out from trenches.
M&L SGSW pipes 150mm bore grade 'A' including laying pipes to level or to falls in trenches, on concrete bed and all necessary extra joints, waste and cutting complete all as specified and directed by EIC.
M&L reinforced concrete drain pipes NP3 150mm bore including laying pipes to level or to falls in trenches, on concrete bed and all necessary extra joints, waste and cutting as jointed complete with collars as specified and directed.
M&L reinforced concrete drain pipes NP3 200mm bore including laying pipes to level or to falls in trenches, on concrete bed and all necessary extra joints, waste and cutting as jointed complete with collars as specified and directed.
M&L for 10 cm PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as concrete bed, width of concrete bedding shall extend laterally 15 cm beyond either side of the outer dia of pipe laid to falls in trenches in any depth including packing under, and haunching against the sides of SGSW/ reinforced concrete drain pipes NP3 150mm bore, after the pipes have been laid and tested including any necessary shuttering and supports to concrete and for laying beds to falls complete all as specified and directed.
M&L for 15 cm PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as concrete bed, width of concrete bedding shall extend laterally 15 cm beyond either side of the outer dia of pipe laid to falls in trenches in any depth including packing under and haunching against the sides of SGSW/ reinforced concrete drain pipes NP3 200mm bore, after the pipes have been laid and tested including any necessary shuttering and supports to concrete and for laying beds to falls complete all as specified and directed.
Dismantling of brick masonry work built in cement mortar including all quions, arches, pillars etc of any description and in any position complete all as specified and directed.
M&L Brick work with sub class 'B' old size brick straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified and directed.
All as per Srl item No. 13 above but except bricks.
M&L for brick work with sub class "B" bricks (old size) straight or curved on plan to any radius in half brick thick wall, built in CM 1:4 complete all as specified and directed.
All as per Srl item No 15 above but except bricks. (old serviceable bricks obtained from item No.12 shall be used)
M&L for flush pointing in CM 1:3 to bricks laid flat (new) and to old with raking out existing joints, complete all as specified and directed.
Taking down cement plaster, any description on brick or concrete surface or stone walls etc including raking out joint, hacking for key, scrubbing down with water etc removing the rubbish off the premises complete all as specified and directed.
M&L rendering 15mm thick on fair face of brick or concrete surface in CM 1:4 to be finished even and fair complete all as specified.
M&L for prepration of newly plastered/un plastered surfaces of wall and applying two coats of white wash complete all as specified and directed.
Demolition reinforced cement concrete of any description and in any position not otherwise specically provided (reinfocement cut as required to facilitate demolition) and removing the demolished material to low lying areas complete all as specified and directed.
M&L for pre cast RCC 1:2:4 type B-1 using 20mm graded stone aggregate as cover slab for manhole and similar work etc including form work complete all as specified and directed.
M&L TMT bars 6 to 8mm dia and over cut to length bent to shape required including crancking spirally for hooking ends and binding with and including MS wire annealed n.less than 0.9mm dia complete all as specified.
M&L for PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) as in mass concrete foundation of manhole complete all as specified and directed.
M&L PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in surface channel and drain including forming fair finished drain or channel in cement concrete using extra cement including forms, moulds, mitred/stopper ends etc complete all as specified.
M&L for removal of blockage between manholes to manhole lines of various sizes & at any depth for sewage by means of (rodding, manually or any other sources) including removing rugs of any type, dirt etc complete all as specified and directed.
M&L cleaning of blockage of WC Indian or European type by removing of all the mud/sludge and getting out including cleaning of SGSW or CI pipe upto First manhole and depositing the sludge in a pit of suitable size at a distance not exceeding 50 meters from the WC and covering the same with the soil obtained from excavation of pit including all excavation and earth work complete all as specified and directed by Engr-in-Charge
M&L cleaning the blockage of bathroom/kitchen by cleaning the nahni traps/gulley traps of all the mud/sludge and getting out, washing thoroughly grating of tarp, CI waste pipes by opening the clearing eyes and depositing the sludge in a pit of suitable size at a distance not exceeding 50 meters from the gully trap and covering the same with the soil obtained from excavation of pit including all excavations and earthwork complete all as specified and directed by Engr-in-Charge
M&L cleaning of existing sewage pipe lines 150mm/200mm internal dia upto 1.50mtr including manholes by removing the manhole covers of any type/size and cleaning by means of hydraulic jet pressure machine as required at site from manholes and well flushing with water after cleaning including getting out sludge if any and liquid materials from connecting manholes deposited in sewer line removing the solids and sludge to any distance and reinstating the manholes cover to its original position as directed by Engr-in-Charge Note: -(i) Earth and excavation included in quoted rates. (ii) Cleaning of Existing sewage pipe lines/manholes by suitable suction pump loaded vehicles/trailers available in the market and dispose effluent out side the defence land. The rate for the same shall be included in the quoted rates.
All as per above item No. 29.00 but exceeding 1.50m and not exceeding 3m depth.
Bailing out sludge from manholes of any size manually or with the help of pump as per site condition and disposal of sludge, solids foul material obtained to any distance exc 500m in low lying area, including removing and refixing manhole covers and flushing with adequate water, the depth of manhole not exc 1.0 m all as directed by Engineer-in Charge.
All as per above item No. 31.00 but depth of manhole exc 1.0m and not exc 3.0 m
Cleaning of existing septic tank of 50 users by taking out sludge/ liquid and removal of the same outside defence land all as specified and directed.
All as per above item no. 33.00 but 100 users
All as per above item no. 33.00 but 150 users
Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level), manholes and drain complete all as specified and directed.
M&L PCC (1:4:8), type D-2 (using 40 mm graded stone aggregate), as in sub base under floor (to raise level only) complete all as specified.
M&L for 50 mm thick cement cocnrete type B-1 (1:2:4) (20mm graded aggregate) as in plinth protection finishing the surface even and fair without using extra cement complete all as specified.
M&L for 60 mm thick PCC (M-35) factory made with gray cement and no pigment interlocking tiles/ paver block of shape/ size as conforming to IS 15658, joints will be filled with fine sand, including dismantling existing tiles complete all as specified and as directed by Engr-in-Charge.
Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Engineer-in-Charge.
Dismantling of cast iron , PVC or drain pipes, jointed in cement mortar and taking out of trenches & wall, complete all as specified and directed.
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall/floors upto 12m height all as specified & directed.
S&F 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall/floors upto 12m height all as specified & directed.
S&F in repair PVC(SWR) 110mm bore bends any radius complete all as specified and directed.
S&F in repair PVC(SWR) 75mm bore bends any radius complete all as specified and directed.
S&F in repair PVC (SWR) 110 mm dia junction single, (Single T) equal or unequal complete all as specified and directed.
S & F in reapir Stack clamps for 110 mm pipe out of 20 mm by 1.5mm galvanised mild steel flat and iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed.
S & F in repair Stack clamps for 75 mm pipe out of 20 mm by 1.5 mm galvanised mild steel flat and iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed.
S&F in repairs urinal waste pipe fixed complete all as specified & directed
S&F in repair PVC waste pipe 32mm dia 800 to 1000mm long fixed to waste fitting of wash basin all as specified and directed.
M&L coloured chequered cement concrete tiles with grey cement and pigment, 30cmx30cmx25mm thick, set, jointed and pointed in neat cement slurry in floors over and including 15mm thick screed bed in cement mortar 1:6 including dismantling existing tiles and screed complete all as specified and directed
A Schedule of Credit for old/unserviceable demolished/dismantled items has been catered for in the tender. The Schedule of Credit is pre-priced by MES. The final amount of the tender shall be arrived at after deducting the total amount of Schedule of Credit from the total amount of BoQ as per General Summary sheet catered for after Schedule of Credit.
KAILASH CONSTRUCTION CO
GORAYA AND CO
M/s. Nirmal Singh
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .