Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.9 LAccepted-AOC AT PO DANARA PS COLLIERY DIST ANGUL ODISHA 759103 | DANARA | ANGUL | ODISHA | 759103 | ₹8.9 L Quoted ₹7.5 L | L1 | Accepted-AOC AWARDED FOR BEING L1 BIDDER |
| 2 | L2₹7.6 LRejected-Finance AT PO KARNAPUR VIA DERA TALCHER DIST ANGUL ODISHA PIN 759103 | ANUGUL | ODISHA | 759103 | ₹7.6 L | L2 | Rejected-Finance REJECTED FOR NOT BEING L1 BIDDER |
| 3 | L3₹9.4 LRejected-Finance AT PO DANARA PS COLLIERY TALCHER DIST ANGUL ODISHA 759103 | TALCHER | ANGUL | ODISHA | 759103 | ₹9.4 L | L3 | Rejected-Finance REJECTED FOR NOT BEING L1 BIDDER |
Tender Value
₹15.2 L
EMD Value
₹19,000
Closing Date
17 Feb 2026, 5:00 pmClosed
STAFF OFFICER (CIVIL), HINGULA AREA
SO (CIVIL), OFFICE OF THE GM, HINGULA AREA, P.O._N.S.NAGAR, TALCHER, ANGUL_759148, ODISHA, INDIA
Making motor foundation with shed for sampling room No.1 and roof sheeting of sampling room 2,3 at RLY. Siding no 9 at Balram OCP under Hingula Area.
2026_MCL_352614_1
MCL/GM(HA)/Civil/e-Tender/ 25-26/130 Dt.06.02.2026
Open Tender
Civil Works - Others
45 days
HINGULA AREA
AS PER NIT
3 documents required · 3 mandatory
₹19,000
22 Apr 2026
7 Feb 2026
19 Feb 2026
7 Feb 2026
17 Feb 2026
7 Feb 2026
7 Feb 2026 - 10 Feb 2026
Item Description
Demolishing lime concrete manually/ by mechanical means and disposal of material within 50 metres lead as per direction of Engineer- in-charge.Nominal concrete 1:4:8 or leaner mix (including equivalent design mix)
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil.
Providing and laying in position excluding cement concrete of level: specified grade the cost of centering and shuttering - All work up to plinth 1:3:6 (1 Cement : 3 coarse sand (zone-Ill) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources)
Providing and laying in position excluding cement concrete of level: specified grade the cost of centering and shuttering - All work up to plinth 1:1.5:3 (1 Cement: 1.5 coarse sand (zone-Ill) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Brick work with Fly Ash Brick (230x115x75 mm size) bricks of class designation 10 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with Fly Ash Brick (230x115x75 mm size) bricks of class designation 10 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but excluding cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Thermo-Mechanically Treated bars of grade Fe-500D or more.Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture of SOMANY or other approved makeapproved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.(300x600mm wall tiles)
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Providing and fixing to existing door frames.30 mm thick factory made Polyvinyl Chloride (PVC) door shutter made of styles and rails of a uPVC hollow section of size 60x30 mm and wall thickness 2 mm (± 0.2 mm), with inbuilt decorative moulding edging on one side. The styles and rails mitred and joint at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 25x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x30 mm and 2 mm (± 0.2 mm) wall thickness fixed to the shutter styles by means of plastic/ galvanised M.S. `U' cleats. The shutter frame filled with a uPVC multi- chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness . The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in- charge.
Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1 mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer's specification and direction of Engineer- in-charge. Extruded section profile size 42x50 mm
Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour. Old work (one or more coats)
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture.
12 mm cement plaster of mix: 1:6(1 cement: 6 fine sand)
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour: New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 Itr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)
Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120 gram per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Ridges plain (500- 600mm)
Wiring for light point/fan point/exhaust fan point/callbell point with1.5sq.mm FRLSPVC insulated copper conductor single corecable insurface/recessed medium class PVC conduit, with piano typeswitch,phenolic laminatedsheet,suitable size M.S.box and earthing the point with1.5sq.mm.FRLSPVC insulated copper conductor single core cable etc.as required.GroupA
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2X2.5 sq.mm+1X2.5 sq.mm earth wire
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor,single core cable insurface/recessed medium class PVC conduit as required. 2X4 sq.mm+1X4 sq.mm earth wire
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor,single core cable insurface/recessed medium class PVC conduit as required. 4X10sq.mm+2X6 sq.mm earth wire
Supplying and fixing metal box of 150mmX75nnmX60mm deep (nominalsize) on surface or inrecess with suitable size of phenolic laminated sheet cover infront including providing and fixing 3 pin 5/6A socket outlet and 5/6A piano type switch,connections,painting etc.as required.
Supplying and fixing metal box of 180mmX100mmX60mm deep(nominal size) on surface or inrecess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6pin 5/6&15/16A socket outlet and 15/16A piano type switch, connections,painting etc.as required.
Supplying and fixing metal box of following sizes(nominal size) on surface or inrecess with suitable size of phenolic laminated sheet cover infront including painting etc. as required. 75mmX75mmX60mm deep
Supplying and fixing metal box of following sizes(nominal size) on surface or inrecess with suitable size of phenolic laminated sheet cover infront including painting etc. as required. 100mmX100mmX60mm deep
Supplying and fixing metal box of following sizes(nominal size) on surface or inrecess with suitable size of phenolic laminated sheet cover infront including painting etc. as required. 150mmX75mmX60mm deep
Supplying and fixing 3 pin,5A ceiling rose on the existing junction box/wooden block including connection setc. As required.
Supplying and fixing brass batten/angle holder including connection etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240V, on surface/recess,complete with tinned copper busbar, neutral busbar, earthbar,din bar, inter connections, powder painted including earthing etc.as required. (But without MCB/RCCB/ Isolator) 6 way, Doubledoor
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240V, on surface/recess,complete with tinned copper busbar, neutral busbar, earthbar,din bar, inter connections, powder painted including earthing etc.as required. (But without MCB/RCCB/ Isolator) 8way, Doubledoor
Providing and fixing 200Amp capacity TP&N disconnector fuses with unit inside the existing panel board with ISI marked HRC fuses including drilling holes include panel,making connections,etc.as required.
Supplying and fixing 5A to 32A rating, 240/415V,10kA,"C"curve,miniature circuit breaker suitable for inductive load of following poles in the existing MOB DB complete with connections,testing and commissioning etc.as required. Single pole
Supplying and fixing 5A to 32A rating, 240/415V,10kA,"C"curve,miniature circuit breaker suitable for inductive load of following poles in the existing MOB DB complete with connections,testing and commissioning etc.as required.Double pole
Supplying and fixing 20A,240V, SPN Industrial type socket outlet,with 2 pole and earth,metal enclosed plug top along with 20 A"C"curve, SP,MCB,in sheet steel enclosure,on surface or inrecess, with chained metal cover for the socket outlet and complete with connections,testing and commissioning etc.as required.
Earthing with G.I. earth plate 600mmX600mmX6mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7metre long etc. with charcoal/coke and salt as required.
Supplying and laying 25mmX5mm G.I strip at 0.50 metre below ground as strip earth electrode,including connection/terminating with G.I.nut,bolt,spring,washer etc.as required.(Jointing shall be done by overlapping and with 2sets of G.I.nut bolt&spring washer spaced at 50mm)
Supplying and fixing following piano type switch/socket on the existing switch box/cover including connection setc.as required. 5/6 amps switch
Supplying and fixing following piano type switch/socket on the existing switch box/cover including connections etc. as required. 15/16A switch
Supplying and fixing following piano type switch/socket on the existing switch box/cover including connections etc. as required. 3 pin5/6A socket outlet
Supplying and fixing following piano type switch/socket on the existing switch box/cover including connections etc.as required. 6pin15/16A socket outlet
Supplying and fixing of wall fan 400mm sweep, 230volts, with double ball bearing copper wound with energy efficent /saving decorative type, smooth sound complete set as required.
Supplying and fixing of Heavy Duty 24 inch 600 mm industrial Ventilating Fan, 230V Created from high-quality engineering plastic, including wall cutting & finising if required. complete set as required.
Supplying and fixing of 36 watt LED Tube Light.
Providing of 2Cx6 Sqmm Aluminium flat Cable 1.1kv grade
Supply and fixing of 250 W Smartbright Slim Led Flood Light with testing certificate of proper brand
Supply of Polycab 25 Sqmm 2 Core Aluminum Armoured Cable
Supply of 50 sqmm 4 core aluminium Armoured Cable
Providing and fixing 200A,16KA,TP MCCB rating and breaking capacity and pole MCCB with the rmomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections,etc.as required.
Supplying and fixing 63A rating, double pole ,240V, isolator in the existing MOB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating ,four pole, 415V, isolator in the existing MOB DB complete with connections ,testing and commissioning etc.as required.
Total impact of GST plus Labour Cess [@ 1 % (BOCW Cess to be deducted from the RA bill as per the value of the work progress)] for the purpose of CTC
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.33 MB
Tendernotice_2.pdf
PDF • 2.37 MB
BOQ_365404.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid