Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.9 LAccepted-AOC 225 NAROT COLONY MODEL TOWN PATHANKOT PB 145001 | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Lowest bid | |
| 2 | L2₹24.0 L+₹2.5 L (11.6%)Rejected-Finance H NO B III 95 MOHALLA GHARTHOLI MISSION ROAD PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance Rejected | |
| 3 | L3₹24.7 L+₹3.3 L (15.2%)Rejected-Finance | L3 | Rejected-Finance Rejected | |
| 4 | L4₹33.5 L+₹12.0 L (56.0%)Rejected-Finance | L4 | Rejected-Finance Rejected |
Tender Value
₹24 L
EMD Value
₹48,000
Closing Date
1 Nov 2021, 6:00 pmClosed
GE SOUTH MAMUN
GE SOUTH MAMUN PATHANKOT
REPAIR/REPLACEMENT OF SECURITY LIGHT, LED FLOOD LIGHT ALONGWITH DAMAGED LT CABLES AND ITS CONNECTED ITEMS AT D-II ZONE AND CBS GHAROTA AREA UNDER GE (S) MAMUN
2021_MES_479423_1
GE(S)/M-51/2021-22
Open Tender
Civil Works
Item Rate
270 days
GE SOUTH MAMUN
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE SOUTH MAMUN
₹48,000
Yes
14 Dec 2021
4 Oct 2021
9 Nov 2021
4 Oct 2021
1 Nov 2021
19 Oct 2021
Amount
Taking down street light fitting or flood light fitting any type and rating from poles, walls or any other indicated situation/location after disconnecting electrically, and refixing after repair at same location or any other and removing unserviceable fittings from site complete all as specified and directed.
Maintenance of street light fitting on pole / wall at any height, cleaning of complete fitting / fixture, removing carbon from connection, tighting of bulb etc without replacing any part and making street light functional complete all as specified and directed.
Supply and fixing as in repair / replacement of HPSV lamp 70W tubular clear lamp on location including disconnecting and taking out of old unsv lamp any type any make from light fitting and replacement of defective lamp complete all as specified and directed.
Supply and fixing as in repair / replacement of HPSV lamp 150 W tubular clear lamp on location including disconnecting and taking out of old unsv lamp any type any make from light fitting and replacement of defective lamp complete all as specified and directed.
Supply and fixing as in repair / replacement of HPSV lamp 250 W tubular clear lamp on location including disconnecting and taking out of old unsv lamp any type any make from light fitting and replacement of defective lamp complete all as specified and directed.
Supply and fixing as in repair / replacement of HPSV lamp 400 W tubular clear lamp on location including disconnecting and taking out of old unsv lamp any type any make from light fitting and replacement of defective lamp complete all as specified and directed.
S&F "as in repair" of street light fitting in replacement of energy efficient tube rod T-5, 24 watt 230V to street light fittings at location after taking out old one complete all as specified and directed.
S&F "as in repair" of street light fitting in replacement of energy efficient tube rod T-5, 14 watt 230V to street light fittings at location after taking out old one complete all as specified and directed.
S&F "as in repair" of street light fitting in replacement of electronic ballast 2x24 Watt suitable for T-5 fitting having pf above 0.9 to street light fittings at location including taking out old one and making connection and testing complete all as specified and directed.
S&F "as in repair" of street light fitting in replacement of electronic ballast 2x14 Watt suitable for T-5 fitting having pf above 0.9 to street light fittings at location including taking out old one and making connection and testing complete all as specified and directed.
Supply and fixing as in repair / replacement heavy duty VPIT open construction copper ballast 400W HPSV/ MH for street light or flood light fitting including disconnecting and taking out of old unsv ballast any type any make from light fitting and making connection and testing complete all as specified and directed.
Supply and fixing as in repair / replacement heavy duty VPIT open construction copper ballast 250W HPSV/ MH for street light or flood light fitting including disconnecting and taking out of old unsv ballast any type any make from light fitting and making connection and testing complete all as specified and directed.
Supply and fixing as in repair / replacement heavy duty VPIT open construction copper ballast 150W HPSV/ MH for street light or flood light fitting including disconnecting and taking out of old unsv ballast any type any make from light fitting and making connection and testing complete all as specified and directed.
Supply and fixing as in repair / replacement heavy duty VPIT open construction copper ballast 70W HPSV/ MH for street light or flood light fitting including disconnecting and taking out of old unsv ballast any type any make from light fitting and making connection and testing complete all as specified and directed.
Supply and fixing as in repair / replacement resin/Powder filled dry type ignitor elctronic 230V suitable 70 watt HPSV/MH lamp fittings for street light or flood light fitting including disconnecting and taking out of old unsv Ignitor any type any make from light fitting and making connection and testing complete all as specified and directed.
Supply and fixing as in repair / replacement resin/Powder filled dry type ignitor elctronic 230V suitable 150 /250/400 watt HPSV/MH lamp fittings for street light or flood light fitting including disconnecting and taking out of old unsv Ignitor any type any make from light fitting and making connection and testing complete all as specified and directed.
Supply and fixing as in repair / replacement porcelain Lamp holder suitable for 400/250/150 watt HPSV/MH lamp with base E40, including disconnecting and taking out of old unsv holder any type any make from light fitting and making connection and testing complete all as specified and directed.
Supply and fixing as in repair / replacement porcelain Lamp holder suitable for 70 watt HPSV/MH lamp with base E27, including disconnecting and taking out of old unsv holder any type any make from light fitting and making connection and testing complete all as specified and directed.
Supply and fixing "as in repair" GI bracket for street light fitting made out of 40mm dia GI pipe light grade 1.2 mtr long each bent to required shape & size as directed by EIC & fixed to pole with and including flat iron clamps 02 Nos made out of 32X 6mm flat iron including GI nuts, bolts &washer and painting of clamps and street light firtting bracket with one coat of red oxide primer, one under coat and one finishing coat with aluminium paint complete all as specified and directed.
Supply and fixing as in repair of 60W LED Street Light luminaire. LED Street Light shall be made up of Pressure Die Cast aluminum housing with black epoxy polyester powder coating for long life. The luminaire shall be complete IP66 for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety.The LED Street light should be top maintainable for easy maintenance.LED Street Light shall use multiple LEDs to get sufficient light output from the luminaire. The LED Street Light shall be of Integral type. The Input voltage range shall be 150V to 270V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED Street Light shall have power factor more than 0.95 complete all as specified and directed.
Supply and fixing as in repair of 72W LED Street Light luminaire. LED Street Light shall be made up of Pressure Die Cast aluminum housing with black epoxy polyester powder coating for long life. The luminaire shall be complete IP66 for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety.The LED Street light should be top maintainable for easy maintenance.LED Street Light shall use multiple LEDs to get sufficient light output from the luminaire. The LED Street Light shall be of Integral type. The Input voltage range shall be 150V to 270V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED Street Light shall have power factor more than 0.95 complete all as specified and directed.
Supply and fixing as in repair of 90W LED Street Light luminaire. LED Street Light shall be made up of Pressure Die Cast aluminum housing with black epoxy polyester powder coating for long life. The luminaire shall be complete IP66 for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety.The LED Street light should be top maintainable for easy maintenance.LED Street Light shall use multiple LEDs to get sufficient light output from the luminaire. The LED Street Light shall be of Integral type. The Input voltage range shall be 150V to 270V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED Street Light shall have power factor more than 0.95 complete all as specified and directed.
Note for srl item No 20 to 22 above 1. Driver shall be potted anti-vibration types. 2. LM-79 and LM-80 test report with 1 Lakh burning hours LED life from NABL lab shall be provided. 3. CRI (Colour Rendering Index) of fixture shall be > 70. 4. CCT (Colour Co-related Temperature of fixture shall be 5700K + 300 K. 5. System Lumen Efficacy shall be > 100 Lm/W. 6. 10 KV separate Surge Protection shall be provided as a part of fitting. 7. 5 years guarantee shall be provided by contractor supported by OEM covering all parts of luminaire. 8. Lenses shall be Modular Type. 9. PCB used shall be MC PCB type. 10. The defect liability period of LED light shall be 05 years from the certified date of completion & the contractor shall replace/repair the defective fitting within 07 days after handing over to contractor for replacement/repair. 11. CA No. shall be written on each fitting before installation. 12. The name of manufacturer to be embossed on the fitting. 13. The fittings shall have arrangement so that maintenance required, if any can be carried out from top cover.
Supply and fixing in replacement of old unserviceable aluminium conductor cable single core PVC insulated and sheathed aluminium conductor cable of size 2.5 sqmm down through the existing pole/GI pipe bracket complete all as specified and directed.
Supply and fixing in replacement toughened clear glass cover rectangular/ circular suitable for flood light fittings/ Street light fitting any type 70 to 150 watts as per sample all as required complete all as specified and directed.
Supply and fixing in replacement PVC conduit heavy duty 25 mm bore cut to size and fixed along the pole for cable protection all as required at site complete all as specified and directed.
S&F in replacement cable of size 10 sqmm, twin core multistranded 1100 volts grade heavy duty cable PVC insulated aluminiun conductor, served with inner sheathed of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1m apart including 4mm suspended with galavnised steel wire, complete all as specified and directed.
S&F in replacement cable of size 6 sqmm, twin core multistranded 1100 volts grade heavy duty cable PVC insulated aluminiun conductor, served with inner sheathed of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1m apart including 4mm suspended with galavnised steel wire, complete all as specified and directed.
M&L for scraping of old paint from the steel tubular pole 9 Mtr height with out removing accessories, preparation of surfaces repainting the pole with one coat of alternative green and white strips of 30cm each upto 1.5 Mtr height using synthetic enamel paint. Marking the pole number with black enamel paint over yellow circle of dia 100mm. Repainting the remaining pole and iron parts i.e 'U' clamps, channels etc above 1.5 mtr height by applying one coat of alumn paint, complete all as specified and directed.
Supply and fixing as in reapir / replacement of pole mounted street light factory fabricated junction box of size 300mmx160mmx250mm of approved make and of appropriate size made out of 2 mm thick CRCA powder coated sheet , including 63A ,Three Phase four wire having four no.AL Bus Bar including 6A SP MCB. The box should have auto Door Lock facility with magnetic Lock having Sizehaving Size box fixed on pole using necerssary fixing arrangement such as clamps,nut,bolts and washer including taking down existing junction box of any description/type etc complete all as specified and directed.
Supply and laying in trenches or fixed to wall/pole or passing through ducts or pipe, cable LT 1100 volts grade heavy duty, XLPE insulated PVC sheathed, armoured heavy duty electric cable , with aluminium conductor of size 16 Sqmm x 2 core complete all as specified and directed. Note:- Excavation and earth work, sand cushioning, brick cover and protection pipe etc. shall be measured and paid for separately.
Description all as per srl item No 30 here-in-before, but cable of size 25 Sqmm x 3.5 core complete all as specified and directed.
Description all as per srl item No 30 here-in-before, but cable of size 50 Sqmm x 3.5 core complete all as specified and directed.
Description all as per srl item No 30 here-in-before, but cable of size 120 Sqmm x 3.5 core complete all as specified and directed.
Description all as per srl item No 30 here-in-before, but cable of size 185 Sqmm x 3.5 core complete all as specified and directed.
Description all as per srl item No 30 here-in-before, but cable of size 240 Sqmm x 3.5 core complete all as specified and directed.
Excavating in trenches in any type of soil, n. exc. 1.5 m wide and n. exc. 1.5 m in depth, for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc n. exc. 10 sqm on plan and n.exc 1.5 m in depth and getting out complete all as specified and directed.
Excavating in trenches in any type of soil, n. exc. 1.5 m wide and exc. 1.5 m but n. exc. 3 m in depth, for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc n. exc. 10 sqm on plan and n.exc 1.5 m in depth and getting out complete all as specified and directed.
Removing excavated material (soil) n.exc. 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed.
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25 cm complete all as specified and directed.
M&L for dry clean fine river sand as in sand cushioning to underground cable 8cm below and 15cm above the cable including punning down of sand layer complete all as specified and directed. Note :- Punned thickness shall only be measured and paid.
M&L for brick protection with sub class 'B' old size brick well burnt laid flat for cable protection abutting each other laid dry with width equal to length of brick complete all as specified and directed.
Supply and fixing in replacement GI tubing light grade 40 mm bore cut to size and fixed along the pole for cable protection including clamp 02 Nos of size 25x4 mm, nut bolts , washers etc complete all as specified and directed.
Supply and fixing in replacement GI tubing light grade 100 mm bore cut to size and fixed along the pole for cable protection including clamp 02 Nos of size 25x4 mm, nut bolts , washers etc complete all as specified and directed.
Supply, installation, connecting electrically and testing in replacement of street light panel box complete with Astroonomical timer ,contactor rating 65 Amp, MCB 63 A TPN complete for mounted made out of CRCA sheet 1.6 mm thick, powder coated, having provision for Astronomical Timer, Contactor, Toggle switch, SP MCBs and MCCBs etc. having self closing door lock complete with fixing clamps or mounting arrangement all as required at site, specified or directed including taking out existing U/S street light switch any type and size complete all as specified and directed.
Supply and fixing in replacement MCB single pole 240 volts, C series, any rating from 6 to 32 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
Supply and fixing in replacement MCB single pole 240 volts, C series , any rating from 63 amps, with rupturing capacity 10 KA,including providing thimble for out going cables complete all as specified and directed.
M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint, including dismantling and taking down carefully old cross arms of any size from pole complete all as specified and directed.
Restretching aluminium conductor or GI wire on existing over head lines (running on 11 Mtrs pole) without removing conductors, unbinding from insulator and rebinding to insulator using aluninium binding wire, connections of incoming and out going cables, binding with spacers where required, (binding wire & spacers included in quoted rate) complete all as specified and directed. (Note:- For measurement length of set of 3 conductors incl GI wire / Cradle or guarding wire shall be taken as one sapn)
M&L for ACSR conductor (Weasel conductor 6 x 2.59 + 1 x 2.59 Al + Steel), of any size drawn straight horizontal on over head lines on poles including binding with insulators using aluminium binding wire, jointing jumpers etc including connections of incoming and out going cables, including dismantling and taking down carefully old ACSR conductor/GI wire of any size from HT/LT overhead line complete all as specified and directed. Note:- 3% for sag shall be added.
S&F in repalcement of pin type, porcelain, vitreous, white,brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade including taking out old one complete all as specified and directed.
S&F in replacement shackle insulators porcelain, vitreous, white,brown or green insulator including one set of galvanised mild steel section of straps 31 x3 mm, dia of bolt 12mm alongwith iron washers and one galvanised iron nut, 75mm height, 95mm dia for 1100 volts grade including taking out old one complete all as specified and directed.
Supplying, jointing and connecting "as in repairs" cable end termination joint kit, out door, heat shrinkable type for underground cable including jointing kits and labour complete for making joints suitable for aluminium conductor cable of size 25 sqmm to 50 Sqmm 3.5 core, 1100 volts grade cable including excavation and earth work complete all as specified and directed.
Supplying, jointing and connecting "as in repairs" cable straight through joint kit, out door, heat shrinkable type for underground cable including jointing kits and labour complete for making joints suitable for aluminium conductor cable of size 25 sqmm to 50 Sqmm 3.5 core, 1100 volts grade cable including excavation and earth work complete all as specified and directed.
S&F in replacement optimum adjustable range MCCB FP 415 volts, 250 Amps rating with rupturing capacity 36 KA including providing thimble for out going cables and taking out unserviceable MCCB FP of any deccription / type etc. complete from LT Panel, complete all as specified and directed.
S&F in replacement optimum adjustable range MCCB FP 415 volts, 350 Amps rating with rupturing capacity 36 KA including providing thimble for out going cables and taking out unserviceable MCCB FP of any deccription / type etc. complete from LT Panel, complete all as specified and directed.
S&F in replacement optimum adjustable range MCCB FP 415 volts, 400 Amps rating with rupturing capacity 36 KA including providing thimble for out going cables and taking out unserviceable MCCB FP of any deccription / type etc. complete from LT Panel, complete all as specified and directed.
S&F in replacement electronic LED security light driver ISI approved company made as suitable for LED fittings of cap upto 45 watts any type and make, complete all as specified and directed.
S&F in replacement electronic LED security light driver ISI approved company made as suitable for LED fittings of cap upto 60 to 120 watts any type and make, complete all as specified and directed.
M&L for scraping of old paint from the steel tubular pole 9 Mtr height with out removing accessories and preparation of surfaces, repainting the pole with one coat of alternative green and white strips of 30cm each upto 1.5 Mtr height using synthetic enamel paint. Marking the pole number with black enamel paint over yellow circle of dia 100mm. Repainting the remaining pole and iron parts i.e 'U' clamps, channels etc above 1.5 mtr height by applying two coat of alumn paint, incl. writting letters or figures (Block, Roman, Italic or Indian) S/L Pole No and location code n. exc. 30cm high, sto, commas, short lines, dashes, hypens, brackets etc complete all as specified and directed.
M&L for painting of PCC pole 11 mtr height without removing accessories with one coat of alternative green and white strips of 30cm each upto 1.5 Mtr height using synthetic enamell paint . marking the pole number with black synthetic enamel paint over yellow circle of dia 100mm. Painting the steel parts i.e clamps, channels etc by applying one coat of alumn paint all as required at site, complete all as specified and directed.
Supply and erecting "as in replacement" in true vertical position steel tubular swaged poles of 9.50 metres long, type 410 SP-31 complete with cast iron base plate, goose neck bracket, finial taper plug , bolt, nuts & screws as specified and painting internal surface with anti-corrosive paint and external surface painting up to 1.5 m height from base of poles with two coats of synthetic enamel paint Ist quality black & yellow colour alternate strip 30 cm wide over a coat of red oxide primer and remaing portion with two coats of aluminum paint over a coat of red oxide primer, including demolition of PCC, complete all as specified and directed. Note:-Excavation and earth work and concrete in foundation and pedestal shall be measured and paid for separately.
M&L for PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and directed. Note:- Volume of pole/strut shall be deducted for the purpose of payment.
M&L for PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) as in pedestal/coping including necessary weathering and form work etc complete all as specified and directed. Note:- Volume of pole/strut shall be deducted for the purpose of payment.
M&L in replacement for stay assembly comprising stay 14 mm dia and 40 cm long stay rod 20 mm dia and 1.8 m long threaded ends with nuts, mild steel plate 30 cm X 30 cm X 6 mm thick and two number of thimble etc. complete with accessories as shown in electrical plate No. 1 of SSR Part-I of 2009 including taking down existing stay assembly complete all as specified and directed. Note:- Loop type insulator, stay clamps, excavation & earh work and concrete shall be measured and paid separately.
M&L for galvanized steel stay wire size 7/ 4.0 mm for stay of poles complete all as specified and directed.
M&L for loop type insulator vitreous, poecelain, white/brown/green, large size, with overall dimensions 90 x140 mm, clearance of hole 25.5 mm complete all as specified and directed.
M/S HIMANSHU BUILDERS
KULBHUSHAN AGGARWAL
M/s. Aggarwal Engineers
Bidder Name
KULBHUSHAN AGGARWAL
M/S SHRI RAM BUILDERS
M/s. Aggarwal Engineers
M/S HIMANSHU BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .