Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.6 LAccepted-AOC SHOP NO 6 BENGALI CLUB MIDDLE POINT SRI VIJAYA PURAM 744101 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹31.5 L+₹3.9 L (14.1%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹32.4 L+₹4.8 L (17.4%)Rejected-Finance NEAR PLAY GROUND BIRDLINE CALICUT POST PORT BLAIR 744105 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | L3 | Rejected-Finance Other than Lowest | |
| 4 | L4₹32.7 L+₹5.0 L (18.2%)Rejected-Finance 018 GROUND FLOOR LEKHRAJ ENCLAVE LEKHRAJ PANNA SECTOR 2 VIKAS NAGAR LUCKNOW UTTAR PRADESH 226022 | LUCKNOW | UTTAR PRADESH | 226022 | L4 | Rejected-Finance Other than Lowest | |
| 5 | L5₹33.0 L+₹5.4 L (19.4%)Rejected-Finance 1ST FLOOR PRABHA SHOPPING COMPLEX OLD PAHARGAON DOLLYGUNJ PORT BLAIR SOUTH ANDAMAN ANDAMAN NICOBAR 744103 UDYAM AN 01 0000143 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L5 | Rejected-Finance Other than Lowest |
Tender Value
₹24 L
EMD Value
₹48,000
Closing Date
16 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE BRICHGUNJ
GE BRICHGUNJ PORT BLAIR - 744 103
CERTAIN SPL REPAIRS AND MINOR WORKS UNDER AGE BR II GE BRICHGUNJ
2023_MES_624462_1
8406
Open Tender
Civil Works
Item Rate
180 days
Brichgunj
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE Brichgunj
₹48,000
Yes
27 Feb 2024
21 Oct 2023
21 Nov 2023
21 Oct 2023
16 Nov 2023
4 Nov 2023
Amount
Dismantling plain or corrugated steel sheeting any gauge, thickness, including Nainital or similar pattern roof coverings.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5 mm thick of any colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
M&L for painting one coat of synthetic enamel paint including preparation to previously treated old steel surfaces of any description, not otherwise described, over 10cm width or grith all as specified and directed.
M&L for taking down existing roof treatment of any description and cleaning the ( surface by scrubbing and cleaning with water and disposing off the rubbish out side the premises.
M&L for screed bedding 10mm thick in CM 1:4 using water proof compound on roof finished even and smooth (WPC will be measured and paid separately)
M & L for water proofing treatment with the following specifications as per manufacturers instructions:- (i) Apply a coat of hot blown bitumen 85/25 @ 1.20 kg/sqm over a coat of bituminous primed surface using glass fibre base bitumen felt, grade 2. (ii) Laying APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyester non woven fabric (wt not less than 150 gms/sqm) laid on primed surface by forced application, with 100mm over laps both longitudinally and transversally and overlaps shall be sealed by torch, membrane shall be taken to the parapet through fillet and shall be tucked in inside after a height of 300 mm. (iii) Apply one coat of hot blown bitumen 85/25 @ 1.2 kg/sqm over the membrane. (iv) Applying a coat of bituminous aluminium paint over a coat of primer over prepared surface all as per manufacturers’ instructions.
M&L for removing loose and broken concrete by chiselling /picking etc upto a depth of 80 to 100 mm from columns, beams and similar structural members cutting edges cleaning the dismantled portion with wire brushes etc to remove dust, dirt and other foreign particles etc and washing with clean water with pressure and removal of debries to a distance not exc 50 M all as specified and directed by Engr-in-Charge, including necessary scaffolding etc complete.
M&L for applying one coat of anti corrossive primer @ 0.25 Lit/Sqm for the steel area to exposed old and new reinforcement to the full circumfrance and length of bars to form unbroken 40 Micron thick film all as specified and directed by Engr-in-Charge.
M&L for applying one coat epoxy bonding agent @ 2.6 sqm/lit or as per manufactures instruction to old concrete surfaces all as specified and directed by Engr-in-Charge to surfaces of columns, beams and similar structural members all as specified
M&L for non shrink, cementitous micro concrete mixed with 12.5 graded stone aggregate using Renderoc RG or equivalent by weight (18 Kg Aggregate :25 Kg Renderoc RG) respectively (as per manufatures instruction) laid in average thickness 80 to 100 mm in surface complete all as specified and as directed by Engineer-in-Charge.
M&L for spraying curing compound as per manufactures instruction on freshly cast concrete surfaces all as specified. Make : Concure WB white of Fosroc.
M&L for removing loose and broken concrete by chiselling /picking etc upto a depth of 10 to 20 mm from floor/roof slab/chajjas and similar structural members cleaning the dismantled portion with wire brushes etc to remove dust, dirt and other foreign particles etc and washing with clean water with pressure and removal of debries to a distance not exc 50 M all as specified and directed by Engr-in-Charge, including necessary scaffolding etc complete.
M&L for application of high build polymer modified cement mortar (1:2.5) mixed with 3 kg SBR per bag of cement in ceiling surfaces 10 to 20mm thick in two layers surfaces over a coat of bonding agent Nito Bond SBR (1 Ltr SBR + 1 Ltr) water + 3 kg cement) (as per manufacturer's instructions) complete all as specified.
M&L for drilling holes in slabs/wall/column/beams for anchor steel reinforcement incl washing with water, inserting lock setP' in the holes and all as specified and directed by Eng-in- Charge.Make : Lock set "P" of Fosroc.
M&L mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips
M&L Mild steel TMT bars 6-8mm dia. And over upto & including 10mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips as in stirrups binders and spacers.
Brushing neat cement slurry with 3 kg of cement per Sqm
S & F coloured joint free non Skid ceramic tiles10 mm thick (square/rectangular) area of each tile exceeding 0.18 but not exceeding 0.38 sqm, in floors etc. set, jointed and pointed in white or coloured cement to match over screed bed in cement mortar 1:4, 15 mm thick, all as specified.
S & F coloured glazed ceramic tiles 300mm x 200mm x 7mm thick on vertical surfaces such as skirting & dados etc set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match with surfaces etc including backing coat of 10mm thick CM 1:3.
Taking down chowkats or frames with shutters area n.exc 1.5 Sqm each(without taking off shutters from the frame) all as specified and as directed
S & F 150 mm long Aluminium, anodised, barrel tower bolts of extruded section.
S&F Aluminium alloy, anodised, sliding door bolt 300mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed.
S&F Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin anodised and fixed type B-21 100mm Size
S & F 150 mm long Extruded Aluminium alloy handles, fabricated type, anodised.
Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge.
Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-Charge
Supply only 4mm thick sheet glass ordinary quality and glazing with rubber packing around the glass, in squares n. exc 0.5 Sqm in each pane complete all as specified and as directed by Engineer-in-charge.
Supply only aluminium alloy wire mesh 0.45 nominal dia of wire and average width of aperture 1.40mm fixed with aluminium wire staples complete all as directed by Engineer-in-Charge.
Taking down cement plaster of any description from wall/ceiling including raking out joints hacking for key, scrubbing down with water etc, complete all as specified and directed.
M&L rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished even and smooth without using extra cement.
M&L rendering 5mm thick in CM 1:4 with using water proofing compound over 10mm thick in CM 1:6 on external surfaces of block masontry even and fair without using extra cement.(WPC shall be added in only 5mm thick top layer of plaster @ 3% by weight of cement content or as per manufacturers instructions.)
Supply only integral water proofing compound
M&L for rendering 5 mm thick in CM 1:3 finished even and smooth without using extra cement on ceiling including cement slurry 3 kg/sqm.
M & L for two coats of OBD over a coat of primer on newly plastered surfaces of walls including nesessary preparation of surfaces all as specified and directed.
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including prepartion and applying priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces
M & L for three coats of white wash on newly plastered surfaces of ceiling including nesessary preparation of surfaces all as specified and directed.
M & L for preparing old decorated surfaces of ceiling and applying three coats of white wash all as specified and directed.
M & L for two coats of OBD over a coat of primer on old plastered surfaces of walls including nesessary preparation of surfaces all as specified and directed.
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including complete removal of existing treatment and applying priming coat of exterior primer applied @ 0.90 litre/ 10 sqm all as specified and as directed.
Demolition of PCC block masonry built in cement mortar all as specified and as directed.
M&L pre-cast cement concrete masonary in PCC 1:3:6 type C1 using 20mm graded aggregate with solid block, exceeding 10cm in width setting in CM 1:6 complete.
M&L pre-cast cement concrete masonary in PCC 1:3:6 type C1 using 20mm graded aggregate with solid block, not exceeding 10cm in width setting in CM 1:6 complete.
M&L rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished even and smooth without using extra cement.
Demolition of cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) all as specified and directed.
M&L for PCC 1:3:6, type C2, (Using 40 mm graded stone aggregate), 75mm thick as in plinth protection/Sub base flooring, finishing surface fair and even, in panels & filling joints with mortar, etc., complete all as specified and directed.
Material & labour for chequred cement concrete tiles of size 20 cm x 20 cm x 25 mm with size of chips up to 12 mm jointed and pointed in neat cement slurry with grey cement and pigment to match the shade including screed bed 20mm in CM (1:6) all as specified and directed.
M&L Hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 10cm thick, watered and rammed to a true surface
S&F Steel rolling shutters, with out ball bearing and hickness of laths 1mm as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out in hard/dense soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm all as specified.
M&L for PCC in foundation filling and mass concrete type C2 1:3:6 (40mm graded stone aggregate) all as specified.
S&F MS steel work in tubular, trusses incl purlins, special shaped washers etc complete using ERW or induction butt welded tubes confirming to IS-1161-1979 grade 240 all as specified.
M&L for plates of plain or chequered, square cut or notched of steel welded to steel structure for base plate etc.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/ dense soil all as specified.
M&L for PCC 1:4:8, type C2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete all as specified
M&L Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm
M&L Removing excavated soil to a distance n.exc 50 m and depositing as directed
M&L for two coats of weather coat(Exterior) all guard emulsion, any colour/tined to new wall surfaces over a coat of primer.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil
M&L for 100mm thick PCC 1:3:6 type C2 all as specified.
M&L for Chequered cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors finished with white cement and pigment including 20mm thick screed bed in CM 1:4 all as specified.
Taking down carefully aluminium point wiring (light, fan, socket or power) DBs complete offering credit, making good disturbed surfaces of walls, floors, etc, all as specified and as directed.
M&L Point wiring complete with 1.5 sqmm single core FRLS PVC insulated and unsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including PVC casing and caping and all accessories fixed to walls / roofs / floors / ceiling etc. and including provision of 1.5 sqmm copper cable green in colour as earth continuity conductor and connected to common earth dolly, including fabricated steel terminal box made out of 1.60mm thick MS sheet concealed in walls, with 3mm thick laminated sheet top cover for housing the switches, socket outlets,fan regulators etc., all as specified and as directed forthe following:-One light point controlled by one switch
All as per item No 63.00 here-in-before but for One fan point controlled by one switch and one regulator
All as per item No 63.00 here-in-before but for One 3 pin switch socket outlet point 5 amps on independent board
All as per item No 63.00 here-in-before but for 3 pin 15 Amps switch socket combination on independent board with 4 sq mm copper cable and provision of 4 sq mm FRLS PVC insulated stranded copper conductor cable for earth continuity conductor connected to common earth dolly connecting upto fittings complete all as specified and as directed.
Supply and fix switch piano flush button single pole oneway 5 amp complete all as specified and as directed.
Supply and fix switch socket combination 3 & 2 pin (multi pin) 5 amp flush type complete all as specified and as directed.
Supply and fix switch socket outlet multipurpose 3 pin 15 and 5 amp controlled by one switch, flush type complete all as specified and as directed.
Supply and fix ceiling rose surface bakelite 65x50mm 3 terminal complete all as specified and as directed.
Supply and fix fan speed regulator, electronic suitable socket type for single phase AC, 240 volts, 50 Hz,100 watts, complete all as specified and as directed by Engineer-in-Charge
Taking down old unserviceable ceiling fan 1200 mm sweep by disconnecting the electric power supply, unscrewing the bolts and nuts, removing the blades and bearing including scrapping of old paint and applying two coats of synthetic enamelled white paint over a coat of red oxide primer complete and refixing back at site with new clamps, nuts, washers, safety wire of size not less than 1.00mm & bolts including cotter pin for complete all as directed.
Supply and fix in repair metal enclosure distribution board SPN, 8 way 240 volts, with 200 amps rated bus bar, double door suitable for mounting MCBs including taking down old MCB/DB complete all as specified and directed. Note-: Incoming & outgoing connections from the DB shall be provided with proper lugs/ thimbles etc
Supply and fix in repair MCB single pole 240 volts, 6 to 32 amps "C" series complete all as specified and as directed by Engineer-in-Charge
Supply and fix single pole and netural 240 Volts 32 amps complete all as specified and as directed by Engineer-in-Charge
Supply and fixing energy efficient aluminium housing LED Smart bright batten 22 /20 Watt mounted batten fitting 4ft in length nano diffuser technology to ensure minimum loss in light transmitted, long life of over 30000 hours including lamp and connecting with twin core shethed cable from fitting to ceiling rose all as specified and as diected.
S&F 25 W New genration energy saving & envoirmental friendly long life versatile pressure dia cast aluminium IP65 road way luminaire with high power LEDs as light and electronic driver complete with necessary brackets (made out of 25 mm bore GI light grade pipe approx. 0.6 M long) nuts, bolts etc to be fixed as on walls complete as directed.
M & L in repairs for sub main wiring complete with two runs of 6 Sqmm FRLS single core PVC insulated unsheathed single core cable 1100 volts grade, multistranded with copper conductor (ISI Marked) drawn through and including PVC Casing and caping and all accessories fixed to wall/ roofs/ floors etc with one run of 6 sqmm FRLS single core multistranded copper conductor as earth continuity conductor, including dismantling unserviceable sub main wiring including accessories,complete all as specified and as directed by Engineer-in-Charge. Note : (1) Two runs of cable one run of casing caping & one run of earth continuity conductor shall be measured as one running metre.
M&L for earthing complete with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less thab 1.5 Meter below normal ground level connected to GI wire 4 mm dia by means of bolts, nuts , check nuts and washers of GI and GI tubing 20 mm bore light grade for earth lead protection up to main earth test point and including concrete pit in PCC (1:3:6) type C1 pre cast RCC (1:2:4) type B1 cover slab 54 x 54 x 5 cm with one handle for lifting made out of 8 mm dia MS bar, wire mesh, 20 mm bore GI tubing (LG) for watering, charcoal or coal and salt in alternate layers including excavation earth work complete all as specified and directed electrical plate No. 3 of SSR Part - I
supply & Lay XLPE insulated, heavy duty 1100 volt grade electric armoured LT UG cable with aluminium conductor of size 25 Sqmm 3.5 Core in trenches/along the wall/including making all connections, saddles, spacers including scaffolding if any required for saddling the cable in walls of building of height up to 25 meter, complete with aluminium lugs as required at site and as directed by Engr-in-Charge
Supply & lay cable protection pipe of HDPE double wall corrugated (DWC) incl couplers,bends etc of size 50 mm OD and ID 38mm confirming to IS 14930 -II and ISI Marked all specified and directed.
M/s Prem Enterprise
M/s Saina Enterprises
SK ENTERPRISES
Island Agency
DEEPAK AGENCIES
M/s Kamal Electrical
Nirman Construction Company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .