| 1 | | It works on the principle of ELISA technique To detect IgM RF antibodies Result time less than 4 hours Storage temperature of reagents 2 to8 deg C Shelf life from the date of manufacture 12 months or more The product should have atleast 3 by 4 of the total shelf life at the time of delivery to the consignee | 2,400 | TEST | dr.anita.chaduvula | 20 |
| 2 | Anti Nuclear antibody profile test ANA | ANA Line immunoassay method to detect minimum of 17 or more autoantibodies Used for detection of autoantibodies for dsDNA Nucleosome Histone SmD1 PCNA P0 SS A Ro 60 SS A Ro 52 SS B La CENP B Scl70 U1 snRNP AMA M2 Jo1 PMScl100 Mi2 andKu 70 BY 80 Kits having DFS70 for exclusion of rheumatic diseases will be preferred Storage temperature of reagents 2 TO 8 deg C Shelf life from the date of manufacture 12 months or more The product should have atleast 3 BY 4 of the total shelf life at the time of delivery to the consignee | 960 | TEST | dr.anita.chaduvula | 20 |
| 3 | C Reactive Protein CRP Kit | Testing principle Semi quantitative Latex Agglutination Slide Method Sensitivity more than 0.6 mg per dl or higher for Agglutination Slide Method Result time Less than 2 to 3 minutes Sample Type Required Serum Sensitivity 98 PERCENT Specificity 98 PERCENT Relevant ISO CE IVD certifications Kit content reagents Positive and negative controls slides applictor stick adequate literature Storage temperature of reagents 2 to 8 deg C Shelf life from the date of manufacture 18 months or more The product should have atleast 3by 4 of the total shelf life at the time of delivery to the consignee | 5,000 | TEST | dr.anita.chaduvula | 20 |
| 4 | Widal Test Kit 2 antigen set S typhi O and S typhi H | Testing principle Semi quantitative Agglutination Slide Method Sensitivity more than 98 to 100 percent Specificity more than 98 to 100 percent Reagents smooth antigen suspensions of the bacilli S typhi O S typhi H S paratyphi AO Sparatyphi BO S paratyphi AH Sparatyphi BH S paratyphi CH Sparatyphi CO and or polyspecific positive control reactive with these antigens Storage temperature of reagents 2 to 8 deg C Shelf life from the date of manufacture 18 months or more The product should have atleast 3 by 4 of the total shelf life at the time of delivery to the consignee | 5,000 | TEST | dr.anita.chaduvula | 20 |
| 5 | Rapid Plasma Reagin RPR test kit | Testing principle Non treponemal flocculation test Qualitative test Result time 6 to 8 minutes Sensitivity more than 98 to 100 percent Specificity more than 98 to 100 percent Storage temperature of reagents 2 to 8 deg C Application For the detection of Anti-Lipoidal antibodies in serum and plasma during Syphilis Specificity Lipid complex reactive with Anti-Lipoidal antibodies Principle Slide flocculation Specimen Serum or plasma Result Type Qualitative Semi quantitative Relevant ISO CEIVD certifications Storage 2 TO 8 deg CKit content RPR antigen Positive and negative controls slides applicator sticks adequate literatureShelf life from the date of manufacture 18 months or more The product should have atleast 3 by 4 of the total shelf life at the time of delivery to the consignee | 3,500 | TEST | dr.anita.chaduvula | 20 |
| 6 | HIV Rapid Test Kit Detects HIV 1 Antibodies and HIV 2 Antibodies and HIV 1 p24 Ag HIV TRI DOT | Testing principle Immuno concentration Qualitative test Sensitivity more than 99 to100 percent Specificity more than 98 to100 percent Result time 5 to 10 minutesBased on immunoconcentration immunofilteration format HIV 1 & HIV 2 antibodies IgM IgG IgA in Human Serum or Plasma using HIV 1 AND HIV2 Antigens Kit content Tridot device Protein A conjugate buffer solution controls sample dropper Storage temperature of reagents 2 to 8 deg C Shelf life from the date of manufacture 18 months or more The product should have atleast 3 by 4 of the total shelf life at the time of delivery to the consignee | 500 | TEST | dr.anita.chaduvula | 20 |
| 7 | Qualitative Hepatitis C Virus HCV TRIDOT | Testing principle Immuno filtration Qualitative test Use of highly purified HCV antigens for Core NS3 NS4 NS5 immobilized on the device Sensitivity more than 99 to100 percent Specificity more than 99 to100 percent Result time 20 to 30 minutes Storage temperature of reagents 2 to 8 deg C Shelf life from the date of manufacture 18 months or more The product should have atleast 3 by 4 of the total shelf life at the time of delivery to the consignee Result time 3min TO 10min Storage 2 TO 8 deg C | 300 | TEST | dr.anita.chaduvula | 20 |
| 8 | Dengue Rapid Test Kit IgM and IgG Antibodies to Dengue Virus and NS1 Ag to Dengue Virus from Day 1 of fever for screening | IgM and IgG Antibodies to Dengue Virus NS1 Ag to Dengue Virus from Day 1 of fever Testing principle Lateral flow chromatographic immunoassay Qualitative test Sensitivity for NS1 more than 95 percent Specificity for NS more than 99 precentage Sensitivity for Dengue IgM and IgG Antibody more than 94 precent Specificity for Dengue IgM AND IgG Antibody more than 96percent Result time Less than 10 TO 15 minutes Kit should be able to detect all the 4 serotypes of dengue viruses DEN 1 DEN 2 DEN 3 and DEN 4 Storage temperature of reagents 2 TO 3 deg C Shelf life from the date of manufacture 18 months or more The product should have atleast 3 by 4 of the total shelf life at the time of delivery to the consignee | 3,000 | TEST | dr.anita.chaduvula | 20 |
| 9 | Quantitative Dengue NS1 Ag FOR CONFIRMATION ELISA | Testing principle Capture ELISA Quantitative test Kit should be able to detect all the 4 serotypes of dengue viruses DEN1 DEN2 DEN3 and DEN4 Sensitivity more than 95 to100 percent Specificity more than 95 to100 percent Result time less than 3 hours Storage temperature of reagents 2 to 8 deg C Shelf life from the date of manufacture 12 months or more The product should have atleast 3 by 4 of the total shelf life at the time of delivery to the consignee | 480 | TEST | dr.anita.chaduvula | 20 |
| 10 | Quantitative Dengue IgM FOR CONFIRMATION ELISA | Testing principle Capture ELISA Quantitative test Kit should be able to detect all the 4 serotypes of dengue viruses DEN1 DEN2 DEN3 and DEN4 Sensitivity more than 95 to100 percent Specificity more than 95 to100 percent Result time less than 3 hours Storage temperature of reagents 2 to 8 deg C Shelf life from the date of manufacture 12 months or more The product should have atleast 3 by 4 of the total shelf life at the time of delivery to the consignee | 480 | TEST | dr.anita.chaduvula | 20 |