Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.4 LAccepted-AOC 213 F BLOCK MEGA MARGANPATTE HADAPSAR PUNE 411013 | PUNE | MAHARASHTRA | 411013 | L1 | Accepted-AOC AOC | |
| 2 | L2₹43.0 L+₹5.9 L (15.9%)Rejected-Finance HO SR NO 73 TAPKIR MALA CHOWK TAPKIR NAGAR KALEWADI PIMPRI PUNE 411017 | PUNE | MAHARASHTRA | 411017 | L2 | Rejected-Finance Bidder not quoted L1 rates | |
| 3 | L3₹44.8 L+₹7.7 L (20.8%)Rejected-Finance | L3 | Rejected-Finance Bidder not quoted L1 rates |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
19 Feb 2024, 6:00 pmClosed
COMMANDER WORKS ENGINEER PUNE
HEADQUARTERS COMMANDER WORKS ENGINEERS GEN CARIAPPA MARG, PUNE-411 001
85880 PREVENTIVE MAINT / REPAIRS TO STP, ETP, RECYCLED WATER SUPPLY AND CONNECTED WORKS AT NEW CHSC AND CONNECTED AREA OF AGE EM-II UNDER GE SOUTH PUNE
2024_MES_638463_1
85880 CWE PUNE
Open Tender
Civil Works
Item Rate
283 days
GE (SOUTH) PUNE
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE SOUTH PUNE
₹96,000
Yes
30 Mar 2024
20 Jan 2024
21 Feb 2024
20 Jan 2024
19 Feb 2024
7 Feb 2024
Amount
M&L for Taking shut down of electric supply for Main Sewage intake Tank of 70 thousand liters, removing coarse bar screen for cleaning and painting, taking out five nos submersible sewarage pump set with cable and dewatering the water /sludge from tank at 670 KLD STP and clean the interior portion of tank (bottom and side of tank) by means of coir/wire brush etc and wash the interior portion by using bleaching powder removal of sludge, vegetation, muds etc., to an appropriate distance as directed/ shown by Engr-in-Charge and preparation of internal plastered/ concrete surfaces of tank and applying two coats nontoxic water proof coating inside the tank including cleaning of drainage pipes and chambers complete all as specified and directed. Note for item no 1 to 41: - a) Surface preparation and application procedure shall be as per manufacturer’s guidelines and directions of Engineer-in-Charge. b) The paint used should not contain any harmful chemical . A manufacturer certificate for the same is mandatory and contractor must produce the certificate as mentioned above before application to Engineer-in-Charge
(c) The rate quoated by the tenderer is deemed to be included in the unit rate of the following : (i) Diesel/ electric Driven Pump Set of appropriate capacity with operators including necessary POL required at site for De- Watering of Sewage septic water including PVC heavy duty flexible hose pipe for suction and delivery purposes. (ii) Lorry/Tractor mounted septic storage tank of appropriate capacity not less than 3 KL should be used for disposing off the same to the location where approved (iii) Necessary Oxygen Mask, Gloves, Gum Boot and all other safety aspects to be observed including necessary Phawda, Steel Bucket, Manila rope etc. required at site and all as directed by the Engineer-in-Charge.
M&L for Taking shut down of electric supply for Oil and Grease chamber and Grit Chamber and removing fine bar screen for cleaning and painting which has inlet from main sewarage Tank and dewatering the water /sludge from oil and grit chamber at 670 KLD STP by any means and clean the interior portion of tank (bottom and side of tank) by means of coir/wire brush etc and wash the interior portion by using bleaching powder removal of sludge, vegetation, muds etc., to an appropriate distance as directed / shown by Engr-in-Charge and preparation of internal plastered/ concrete surfaces of tank and applying two coats nontoxic water proof coating inside the tank complete all as specified and directed.
All as per Ser. Item No. 2 above but for STP of capacity 150 KLD complete all as specified and directed.
All as per Ser. Item No. 2 above but for ETP of capacity 55 KLD complete all as specified and directed.
All as per Ser. Item No. 2 above but for ETP of capacity 47 KLD complete all as specified and directed.
M&L for Taking shut down of electric supply for Equilization tank for cleaning and painting and dewatering the water /sludge at 670 KLD STP by any means and clean the interior portion of tank (bottom and side of tank) by means of coir/wire brush etc and wash the interior portion by using bleaching powder removal of sludge, vegetation, muds etc., to an appropriate distance as directed / shown by Engr-in-Charge and preparation of internal plastered/ concrete surfaces of tank and applying two coats nontoxic water proof coating inside the tank complete all as specified and directed.
All as per Ser. Item No. 6 above but for STP of capacity 150 KLD complete all as specified and directed.
All as per Ser. Item No. 6 above but for ETP of capacity 55 KLD complete all as specified and directed.
All as per Ser. Item No. 6 above but for ETP of capacity 36 KLD complete all as specified and directed.
M&L for taking shut down of electrical supply for Anoxic Tank of size 1.8 m dia x 5.0 m SWD + 0.5 m FB of MS FRP construction and replacing unserviceable internals comprising of media, SS Air grid, SS rising pipe, mixer of existing size, media retaing sieves etc completely from MS FRP construction tank and dewatering the water /sludge from Anoxic tank at 670 KLD STP by any means and clean the interior portion of tank (bottom and side of tank) by means of coir/wire brush etc and wash the interior portion by using bleaching powder removal of sludge, vegetation, muds etc., to an appropriate distance as directed / shown by Engr-in-Chage and apply one coat of epoxy paint on all steel surface such as ladder railing etc., and writing letters with white paint (date of cleaning) on black painted surface with synthetic enamel paint all as specified and directed. (Note- Material used in replacement will be measured and paid seprately)
All as per Ser. Item No. 10 above but Anoxic tank of size 1.6m x 1.3m x 3m swd +0.5FB for STP of capacity 150 KLD complete all as specified and directed.
M&L for Taking shut down of electrical supply for MBBR Tank of size 2.6 m dia x 5.0 m SWD + 0.6 m FB of MS FRP construction and replacing unserviceable internals comprising of media, SS Air grid, SS rising pipe, Air rotameter, media retaining sieves etc completely from MS FRP construction tank and dewatering the water /sludge from MBBR tank at 670 KLD STP by any means and clean the interior portion of tank (bottom and side of tank) by means of coir/wire brush etc and wash the interior portion by using bleaching powder removal of sludge, vegetation, muds etc., to an appropriate distance as directed / shown by Engr-in-Chageand apply one coat of epoxy paint on all steel surface such as ladder railing etc., and writing letters with white paint (date of cleaning) on black painted surface with synthetic enamel paint all as specified and as directed. (Note- Material used in replacement will be measured and paid seprately)
All as per Ser. Item No. 12 above but MBBR tank of size 1.6m x 1.6m x 5m swd +0.6FB for STP of capacity 150 KLD complete all as specified and directed.
M&L for Taking shut down of electric supply for Tube Settler Tank of size 3.1 m dia x 2.7 m SWD + 0.3 m FB of MS FRP construction and replacing unserviceable internals etc completely from MS FRP construction tank and dewatering the water /sludge from Tube Settler tank at 670 KLD STP by any means and clean the interior portion of tank (bottom and side of tank) by means of coir/wire brush etc and wash the interior portion by using bleaching powder removal of sludge, vegetation, muds etc., to an appropriate distance as directed / shown by Engr-in-Chage and apply one coat of epoxy paint on all steel surface such as ladder railing etc., and writing letters with white paint (date of cleaning) on black painted surface with synthetic enamel paint all as specified and as directed. (Note- Material used in replacement will be measured and paid seprately under relevant item)
All as per Ser. Item No. 14 above but tube settler tank of size 3.2m x 1.3m x 2.7m swd +0.3FB for STP of capacity 150 KLD complete all as specified and directed.
All as per Ser. Item No. 14 above but tube settler tank of size 1.9m x 1.9m x 2.5m swd +0.3FB for ETP of capacity 55 KLD complete all as specified and directed.
All as per Ser. Item No. 14 above but tube settler tank of size 1.0m x 1.0m x 2.5m swd +0.3FB for ETP of capacity 36 KLD complete all as specified and directed.
All as per Ser. Item No. 14 above but tube settler tank of size 1.2m x 1.2m x 2.5m swd +0.3FB for ETP of capacity 47 KLD complete all as specified and directed.
M&L for Taking shut down of electric supply for Chlorine Contact cum Filter feed Tank (Chlorination Tank) of size 5.4 x 2.4x 2.2 m SWD + 0.3 m FB of MS FRP construction and replacing unserviceable internals etc completely from MS FRP construction tank and dewatering the water /sludge from Chlorine Contact cum Filter deed Tank (Clorination Tank) at 670 KLD STP by any means and clean the interior portion of tank (bottom and side of tank) by means of coir/wire brush etc and wash the interior portion by using bleaching powder removal of sludge, vegetation, muds etc., to an appropriate distance as directed / shown by Engr-in-Chageand apply one coat of epoxy paint on all steel surface such as ladder railing etc., and writing letters with white paint (date of cleaning) on black painted surface with synthetic enamel paint all as specified and as directed. (Note- Material used in replacement will be measured and paid seprately in schedule)
All as per Ser. Item No. 19 above but Chlorine Contact cum Filter feed Tank (Chlorination Tank) of size 3.2m x 1.3m x 1.5m swd +0.3 FB for STP of capacity 150 KLD complete all as specified and directed.
All as per Ser. Item No. 19 above but Chlorine Contact cum Filter feed Tank (Chlorination Tank) of size 2.5m x 1.0m x 1.2m swd +0.3 FB for ETP of capacity 47 KLD complete all as specified and directed.
M&L for Taking shut down of electric supply for Sludge Collection Tank of size 4.7 x 2.5x 2.2 m SWD + 0.5 m FB of MS FRP construction and replacing unserviceable internals etc completely from MS FRP construction tank and dewatering the water /sludge from Sludge Colletion Tank at 670 KLD STP by any means and clean the interior portion of tank (bottom and side of tank) by means of coir/wire brush etc and wash the interior portion by using bleaching powder removal of sludge, vegetation, muds etc., to an appropriate distance as directed / shown by Engr-in-Chageand apply one coat of epoxy paint on all steel surface such as ladder railing etc., and writing letters with white paint (date of cleaning) on black painted surface with synthetic enamel paint all as specified and directed. (Note- Material used in replacement will be measured and paid seprately)
All as per Ser. Item No. 22 above but Sludge Collection Tank of size 2.0m x 2.0m x 1.5m swd +0.5FB for STP of capacity 150 KLD complete all as specified and directed.
All as per Ser. Item No. 22 above but Sludge Collection Tank of size 1.7 x 1.7x 1.0 m SWD + 0.3 m FB for ETP of capacity 36 KLD complete all as specified and directed.
All as per Ser. Item No. 22 above but Sludge Collection Tank of size 1.9 x 1.9x 1.0 m SWD + 0.3 m FB for ETP of capacity 55 KLD complete all as specified and directed.
All as per Ser. Item No. 22 above but Sludge Collection Tank of size 2 x2x 1.0 m SWD + 0.5 m FB for ETP of capacity 47 KLD complete all as specified and directed.
Supply, filling, testing and regulating Dual Media STP filter in mild steel construction of 1.7 m dia and 1.8 m HOS complete at 670 KLD STP for proper filtering of water using as per existing material, superior grade and quality and silica content should not be less than 90% in the existing filter complete all as specified and directed.
All as per Ser. Item No. 27 above but for STP of capacity 150 KLD complete all as specified and directed.
Supply, filling, testing and regulating Activated Carbon STP filter in mild steel construction of 1.8 m dia and 1.8 m HOS at 670 KLD STP for proper filtering of water using as per existing material, superior grade and quality and carbon content should not be less than 90% in the existing filter complete all as specified and directed.
All as per Ser. Item No. 29 above but of 0.9 m dia and 1.8 m height for STP of capacity 150 KLD complete all as specified and directed.
All as per Ser. Item No. 29 above but of 0.6 m dia and 1.8 m height for ETP of capacity 47 KLD complete all as specified and directed.
M&L for Taking shut down of electric supply for Treated Water Tank of 670 KLD STP, dewatering the water /sludge from tank by any means and clean the interior portion of tank (bottom and side of tank) by means of coir/wire brush etc and wash the interior portion by using bleaching powder removal of sludge, vegetation, muds etc., to an appropriate distance as directed / shown by Engr-in-Chage and preparation of internal plastered/ concrete surfaces of tank and applying two coats nontoxic water proof coating inside the tank complete all as specified and directed.
All as per Ser. Item No. 32 above but for STP of capacity 150 KLD complete all as specified and directed.
All as per Ser. item no 32 above but for ETP of capacity 47 KLD complete all as specified and directed.
M&L for Dewatering the water /sludge from the flash mixing tank of 55 KLD effluent treatment tank in MS FRP construction fitted with agitator and 700 ltr tank by any means and clean the interior portion of tank (bottom and side of tank) by means of coir/wire brush etc and wash the interior portion by using bleaching powder removal of sludge, vegetation, muds etc., to an appropriate distance complete all as specified and directed.
All as per Ser. Item No. 35 above but flash mixing tank of capacity 300 ltr for ETP of capacity 47 KLD complete all as specified and directed.
All as per Ser. Item No. 35 above but flash mixing tank of capacity 200 ltr for ETP of capacity 36 KLD complete all as specified and directed.
M&L for Dewatering the water /sludge from the Flocculation tank of 55 KLD effluent treatment tank in MS FRP construction fitted with agitator and 2000 ltr tank by any means and clean the interior portion of tank (bottom and side of tank) by means of coir/wire brush etc and wash the interior portion by using bleaching powder removal of sludge, vegetation, muds etc., to an appropriate distance as directed / shown by Engr-in-Chage complete all as specified and directed.
All as per Ser. Item No. 38 above but Flocculation tank of capacity 1000 ltr for ETP of capacity 47 KLD complete all as specified and directed.
All as per Ser. Item No. 38 above but Flocculation tank of capacity 600 ltr for ETP of capacity 36 KLD complete all as specified and directed.
M&L for Dewatering the water /sludge from the Aeration Tank and MBR tank of 47 KLD effluent treatment tank in MS FRP construction clean the interior portion of tank (bottom and side of tank) by means of coir/wire brush etc and wash the interior portion by using bleaching powder removal of sludge, vegetation, muds etc., to an appropriate distance as directed / shown by Engr-in-Chage complete all as specified and directed.
M&L for servicing of continuous feed sludge multi Screw Press Machine by OEM only of 2.5 Cum/hr capacity with DWPE dosing system comprising of one no HDPE 500 Lt tank with agitator , dosing pump 30 lph capacity by dismantling of existing unserviceable motor, all parts of the the screw press completely for complete servicing and cleaning with recommended chemicals by OEM only for smooth functioning of screw press machine at 670 KLD STP, assembling complete motor, oiling, greasing, reinstalling and testing complete at site on full load complete all as specified and directed by Engr-in-Charge.
M&L for servicing of continuous feed sludge multi Screw Press Machine by OEM only of 0.75 Cum/hr capacity with DWPE dosing system comprising of one no 200 Lt tank with agitator , dosing pump 8 lph capacity by dismantling of existing unserviceable motor, all parts of the the screw press completely for complete servicing and cleaning with recommended chemicals by OEM only for smooth functioning of screw press machine at 150 KLD STP, assembling complete motor, oiling, greasing,reinstalling and testing complete at site on full load all as directed by Engr-in-Charge.
S & F for Moving bed bio reactor media as per existing moving bed bio reactor, type- cylindrical / circular shaped media- wagon wheel design having external fins, surface area-400 Sqm, non toxic, material of construction- Virgin PP , milky white including taking out and disposal of existing media at 670 KLD STP complete all as specified and directed.
All as per Ser. Item No. 44 above but for 150 KLD STP complete all as specified and directed.
S & F for Anoxic media as per existing and existing surface area , type- PP shaped media, size of reactor tank-1.8 m dia x 5.0 m SWD + 0.5 m FB including taking out and disposal of existing media at 670 KLD STP complete all as specified and directed.
All as per Ser. Item No. 46 above but Anoxic tank of size 1.6m x 1.3m x 3m swd +0.5FB for STP of capacity 150 KLD complete all as specified and directed.
S & F for Tube settler tank media as per existing , Shape of media - Hexagonal (Chevron) shaped media- MOC of Media- UV Stablized Virgin PVC Base, size of reactor tank-3.1 m dia x2.7 m SWD + 0.3 m FB including taking out and disposal of existing media at 670 KLD STP complete all as specified and directed.
All as per Ser. Item No. 48 above but tube settler tank of size 3.2m x 1.3m x 2.7m swd +0.3FB for STP of capacity 150 KLD complete all as specified and directed.
All as per Ser. Item No. 48 above but tube settler tank of size 1.9m x 1.9m x 2.5m swd +0.3FB for ETP of capacity 55 KLD complete all as specified and directed.
All as per Ser. Item No. 48 above but tube settler tank of size 1.0m x 1.0m x 2.5m swd +0.3FB for ETP of capacity 36 KLD complete all as specified and directed.
All as per Ser. Item No. 48 above but tube settler tank of size 1.2m x 1.2m x 2.5m swd +0.3FB for ETP of capacity 47 KLD complete all as specified and directed.
S & F One lot of air grid for equalization tank as per existing of uPVC construction for providing aeration in the tank suitable to provide the 115 Cum/hr air to the tank covering complete bottom surface of the tank at 670 KLD STP including taking out and disposal of existing unsv air grid complete all as specified and directed.
All as per Ser. Item No. 53 above but 30 Cum/hr for 150KLD STP complete all as specified and directed.
All as per Ser. Item No. 53 above but 10 Cum/hr for 36KLD ETP complete all as specified and directed.
M&L for Disconnection of electric connection taking out of Non clog submersible pump set with motor of any capacity from raw sewage sump of 670 KLD STP and cleaning with water, cleaning the slots and replacing nylon rope etc., lowering to existing position and reconnected all electrical connections complete all as specified and directed.
M&L for Disconnection of electric connection taking out of Non clog submersible pump set with motor of capacity 7.5 HP complete from raw sewage sump of 670 KLD STP and disconecting of motor opening of motor removing sludges, cleaning of slots including replacement of burnt copper winding with existiing size/ gauge, existing size of ball bearing drive end side, non drive end side and other spare parts such as oil seal, glands etc and after repairing, testing of Pump Set, lowering in existing position and reconnected the all electrical connections complete all as specified and directed. [Note : i) Transportation charges for the motor to wksp & back are deemed to be included in rates quoted, no extra payment will be made on this account. ii) Pump set issued for repair must be returned & installed duly repaired within seven days otherwise Rs 500 per day per pump will deducted from the bill as penalty. iii) Minor items like nut/bolts, bearing grease, packing gaskets of required size to be taken in consideration while quoting the rates. No extra payment will be made on this account.]
All as per Ser. Item No. 57 above but motor of capacity 3 HP complete all as specified and directed.
All as per Ser. Item No. 57 above but motor of capacity 2 HP complete all as specified and directed.
M&L for Disconnection of electric connection taking out of submersible pump set with motor of capacity 20HP complete from Treated water tank of 670 KLD STP and disconecting of motor, opening of motor, cleaning of slots including replacement of burnt copper winding with existiing size/ gauge, existing size of ball bearing drive end side, non drive end side and other spare parts such as oil seal, glands etc and after repairing, testing of Pump Set, lowering in existing position and reconnected the all electrical connections complete all as specified and directed.
All as per Ser. Item No. 60 above but jockey pump from Treated water tank at 670 KLD STP complete all as specified and directed.
Dismantling of existing unserviceable motor of capacity 0.5 HP to 2 HP in centrifugal pump set from foundation, split opening into the parts at work shop and repair the motor by rewinding of motor with supper enamelled copper winding wire of suitable gauge/size as exists by replacing paper insulation of class F and fire proof sleeves and varnishing by cleaning of stator slots, assembling complete motor, oiling, greasing,reinstalling and testing complete at site on full load all as directed by Engr-in-Charge.
All as per Ser. Item No. 62 above but 5 HP motor complete all as specified and directed.
S&F in repair Lubricated and graphited general purpose asbestos packing on glands of pumpsets of diameter upto 12.5 mm complete all as directed by Engr-in-Charge.
Dismantling of existing unserviceable 0.5 to 2 HP motor of centrifugal pump set from foundation painting by synthetic enamel paint two coat after cleaning and preparing surface for painting, reinstalling and testing complete at site on full load all as directed by Engr-in-Charge.
All as per Ser. Item No. 65 above but 5 HP motor complete all as specified and directed.
S&F in repair complete set of pump gasket fitting of suitable size complete all as specified and directed.
Supply and fix in repairs front ends bearing of same size as existing suitable for pump & motor of capacity 0.5 HP to 2 HP motor complete all as spd and directed.
All as per Ser. Item No. 68 above but 5 HP motor complete all as specified and directed.
Supply and fix in repairs rear ends bearing of same size as existing suitable for 0.5 HP to 2 HP motor complete all as spd and directed.
All as per Ser. Item No. 70 above but 5 HP motor complete all as specified and directed.
S&F in repair CI impeller along with lock key for centrifugal monoblock / split casing pumps as per existing suitable for 0.5 HP to 2 HP motor complete all as spd and directed.
All as per Ser. Item No. 72 above but 5 HP motor complete all as specified and directed.
M&L for servicing of twin lobe air cooled compressor /air blower having flow rate of 375 Cum/hr at 6 mtr head with 20 HP motor unit along with replacement of recommended spares as per manufacturers instruction / kit and replacement of compressor oil, air filter, oil filter, etc and testing complete all as directed by Engr-in-charge. (Note : Cost of Spares required will be measured and paid separately)
All as per Ser. Item No. 74 above but flow rate of 155 Cum/hr at 5.5 mtr head with 10 HP motor complete all as specified and directed.
All as per Ser. Item No. 74 above but flow rate of 10 Cum/hr at 3 mtr head with 0.74 HP motor complete all as specified and directed.
All as per Ser. Item No. 74 above but flow rate of 110 Cum/hr at 4 mtr head with 5 HP motor complete all as specified and directed.
M & L for Advanced vacuum pump fluid specifically designed for use in mechanically operated vacuum pumps grade in blower during the servicing complete as directed by Engr-in-charge.
M & L for set of gears with hub (complete hardware) In blower complete as directed by Engr-in-charge.
S & f in repairs air filter as spare parts to be used in blower during the servicing complete as directed by Engr-in-charge.
S & F for fan belt for compressor of size B-52, including removal of old unserviceable one complete all as specified and directed.
S & F in replacement ball bearing as required in servicing of blower during the servicing complete as directed by Engr-in-charge.
S & F for Pressure gauge with pressure range 0-7 Kg/sq cm and control valve including removal of old unserveceable one complete all as specified and directed.
S & F customised GI sheet having thicknes of sheet 2 mm for canopy of centrifugal pumps and motors installed outdoor including necessary nut bolts washers etc complete all as specified and directed.
M&L for running welding of thickness not exc 6mm in repairs complete all as specified and directed.
M & L for Servicing of gear box with ratio 70:1 of secondary clarifier including replacement of unseviceable gear oil , removing and replacement of worn out small and big gear wheel of gear box with pully of same size and model complete all as specified and directed
M&L for servicing of Ozonator by opening with required tools, removing dust particals and servicing completely for its serviceablity and assembling complete and testing complete at site on full load all as directed by Engr-in-Charge.
M&L for servicing of inline full bore type electromagnetic flow meter by opening with required tools, removing dust particals and servicing completely for its serviceablity and assembling complete and testing complete at site on full load all as directed by Engr-in-Charge.
M&L for servicing of online chlorine analyser for measurement of residual chlorine in the treated sewage by opening with required tools, removing dust particals and servicing completely for its serviceablity and assembling complete and testing complete at site on full load all as directed by Engr-in-Charge.
Testing of treated sewage water for BOD, COD and TSS as per norms /standard Raw Sewage Characteristics from Govt approved laboratory complete all as directed by Engr-in-charge. (Note: Contractor shall collect water sample from chlorine contact tank of STP once in a month for testing of treated water from Govt approved agency and report shall be submitted to Engr in charge)
M & L for cleaning of surrounding area of STP (not exceeding 10000 Sqm) by surface dressing or trimming of natural ground to remove small unequalities not exceeding 15 cm deep including removing vegetation / shrubs / brush wood / under-growth etc cleaning of drains & carrying away the rubbish and dewatered sludge/cake to an apporpiate distance at an interval of every 30 days all as directed by Engr-in-charge.
Supply only Calcium Hypochlorite granual having chlorine concentration level 60 to 70 % for water treatment which is a white to off white free flowing granular as traditional product in 45 Kg packing complete all as specified. (Make : As per E-in-C's Branch approved manufacturer.)
Supply only for microbial bio culture ( in requisite doses) used for decomposition of sewage , the bioculture must grow over temperature range of 5°C to 55°C and PH range 5.5 to 9.5 all as specified and directed by Engineer in charge (Note : In addition to above contractor will have to add requisite amount of jaggery for bacterial growth from dose to dose.The quoted rate deemed included the cost of jaggery.)
Supply only sodium hypochlorite solution of 6 % strength in sealed container all as specified and directed. (Make : As per E-in-C's Branch approved manufacturer)
Supply only poly aluminium chloride solution having clear transparent appearance having ph 3.0 to 4.0 and specific gravity 1.18 to 1.40 in sealed container all as specified and directed. (Make : As per E-in-C's Branch approved manufacturer.)
Supply only Engine oil 15W40 for blowers in sealed container all as specified and directed. (Make: HP/Castrol/Servo)
S & F CI butterfly valve with both side flanged ends PN 1.6 ISI marked 125 mm dia including jointing material such as gasket, nut, bolts etc including removal of old unsv one complete all as specified and directed by Engineer-in-Charge.
S & F GI butterfly valve with both side flanged ends PN 1.6 ISI marked 125 mm dia including jointing material such as gasket, nut, bolts etc including removal of old unsv one complete all as specified and directed by Engineer-in-Charge.
All as per Ser. Item No. 98 above but 80 mm dia complete all as specified and directed.
All as per Ser. Item No. 98 above but 65 mm dia complete all as specified and directed.
All as per Ser. Item No. 98 above but 50 mm dia complete all as specified and directed.
All as per Ser. Item No. 98 above but 40 mm dia complete all as specified and directed.
Supply and fix 50 mm dia green/ white PVC Hose pipe flexible on suction pump complete including removal of unservicable PVC Hose pipe from suction pump complete all as specified and as directed by Engineer-in-Charge.
Supply and fix 40 mm dia green/ white PVC Hose pipe flexible on suction pump complete including removal of unservicable PVC Hose pipe from suction pump complete all as specified and directed by Engineer-in-Charge.
S&F 15 mm Ball brass valves screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed by Engineer-in-Charge.
All as per Ser. Item No. 105 above 25 mm dia complete all as specified and directed.
All as per Ser. Item No. 105 above 40 mm dia complete all as specified and directed.
S&F in replacement Non-return valve dia 80 mm PN 1.6 & jointing complete including all necessary nuts bolts, washer etc. complete all as specified and directed.
S&F in replacement Sluice Valve of 150mm, flanged dia PN 1.6 complete with brass spindle with M&L for fixing/jointing on DI pipe complete all as specified and directed.
S&F in replacement Sluice Valve of 80 mm, flanged size PN 1.6 complete with brass spindle with M&L for fixing /jointing on GI pipe complete all as specified and directed.
Supply, installation, testing and commissioning of heavy duty adjustable type sprinkler having water lubricating drive flow rate 0.13 to 1.23 Cum/hr, 2.2 to 20.5 ltr/min. Recommended pressure range 1.7 to 3.8 bar, 170 to 380 kPa. Operation pressure range 1.4 to 7.0 bar, 140 to 700 kPa , angle 50 degree to 360 degree arc adjustment type ,all as specified and directed. (Make : Hunter, Model: PGP Ultra Sprinkler or equivalent in Rain Bird, or Sky Agro)
Supply, laying and testing of PVC Droplet pipe 16 mm dia for droplet systems complete all as specified and directed. (Make: Hunter, or equivalent in Rain Bird, or Sky Agro)
M&L for Cutting/making connection/fixing of distribution branch PVC pipe in 16mm to 40mm bore for water sprinklers and nozzles etc. complete all as specified and directed.
Supply, laying and testing of UPVC pipe 25 mm bore for sprinkler system complete all as specified and directed.
Supply, laying , testing and commissioning PVC insulated and sheathed flat with stranded copper conductor of 1100 volts grade control cable cross sectional area of 16 sqmm 3 core complete all as specified and directed.
Supply, laying , testing and commissioning PVC insulated and sheathed flat with stranded copper conductor of 1100 volts grade control cable cross sectional area of 6 sqmm 3 core complete all as specified and directed.
Supply, laying , testing and commissioning PVC insulated and sheathed flat with stranded copper conductor of 1100 volts grade control cable cross sectional area of 4 sqmm 3 core complete all as specified and directed.
S&F armoured copper cable 2 core 1.5 Sqmm with stranded copper conductor 1100V grade complete all as specified and as directed
S&F armoured copper cable 3 core 4 Sqmm with stranded aluminium conductor 1100V grade complete all as specified and as directed
S&F armoured copper cable 3 core 10 Sqmm with stranded aluminium conductor 1100V grade complete all as specified and as directed
Labour only for inspection of fault in panel, starter, motors and replacement of unserviceable electronic parts including taking down and testing all as directed by Engr-in -Charge. [Note : 1. Spare parts of panel, starter etc. will be measured and paid separately 2. All T& P and transport used is deemed to be included in quoted item rate]
Supply only Front Mounting Add-on aux Contact Block 2 NO + 2 NC complete all as specified and directed.
Supply only Power contactor 70 Amps 3 pole 415 volts AC 3 heavy duty complete all as specified and directed.
Supply only Power contactor 40 Amps 3 pole 415 volts AC 3 heavy duty complete all as specified and directed.
Supply only Power contactor 32 Amps 3 pole 415 volts AC 3 heavy duty complete all as specified and directed.
Supply only Power contactor 20 Amps 3 pole 415 volts AC 3 heavy duty complete all as specified and directed.
Supply only Single phase preventer suitable for existing make and capacity complete all as specified and directed.
Supply only Digital panel volt Meter 3 phase Flush Mounting 96x96mm, Accuracy Class-I, input voltage measurement range 17-520V AC (P-P) complete all as specified and directed.
Supply only Digital panel ammeter, 3 phase 5A, Flush Mounting 96x96mm, Accuracy Class-I, CT/PT Site programmable complete all as specified and directed.
Supply only Electronic Timer 160-500V ,for 12-120sec complete all as specified and directed.
Supply only Thermal Over load relay suitable for existing make and capacity complete all as specified and directed.
Supply only dry run protection relay complete all as specified and directed.
Supply only Indicator lamp 3 phase complete all as specified and directed.
Supply only ON/OFF push button complete all as specified and directed.
Supply only Motor Protection Circuit Breakers 1/1.6 amp complete all as specified and directed.
Supply only Motor Protection Circuit Breakers 10 amp complete all as specified and directed.
Supply only Motor Protection Circuit Breakers 13/16 amp complete all as specified and as directed
S&F in repair DOL starter in existing panel suitable for 0.5 HP to 2 HP 415 volts as per existing including wiring from motor to DOL starter with suitable size copper conductor cable complete all as spd and directed. (Make - \L&T/Siemens/BCH/Havells)
S&F in repair DOL starter in existing panel suitable for 5 to 20 HP , 415 volts as per existing including wiring from motor to DOL starter with suitable size copper conductor cable complete all as spd and directed. (Make - L&T/Siemens/BCH/Havells)
S&F in replacement in existing panel automatic star delta starter suitable for 10 to 20 HP 415 Volts complete all as spd and directed. (Make-L&T/Siemens/BCH/Havells)
Supply and fix MCB SP 6 to 40 Amps, C curve 415 volts complete all as specified and as directed
S&F in replacement MCB FP 16 to 40 Amps, 415 volts complete all as specified and as directed
S&F in replacement MCB DP 6 to 32 Amps, 240 volts complete all as specified and as directed
S&F MCCB with rating of 160 Amps, 415 Volts 3 pole with 16kA breaking capacity, thermal magnetic adjustable of overload & short circuit release as per IS-13947 & IEC 60947-2 & the service short circuit breaking capacity (Ics) should be equal to ultimate breaking capcity(Icu). MCCB should be with suitable spreaders and phase barriers for each terminals complete all as specified and as directed.
S&F MCCB with rating of 25 to 100 Amps, 415 Volts 3 pole with 16kA breaking capacity, thermal magnetic adjustable of overload & short circuit release as per IS-13947 & IEC 60947-2 & the service short circuit breaking capacity (Ics) should be equal to ultimate breaking capcity(Icu). MCCB should be with suitable spreaders and phase barriers for each terminals complete all as specified and as directed.
S&F corrugated DWC/HDPE pipe green coloured 75 mm in bore including all acessories as per site requirement complete all as specified and directed.
S&F corrugated DWC/HDPE pipe green coloured 50 mm in bore including all acessories as per site requirement complete all as specified and directed.
M&L for Painting on pipes by scrapping the old surface, primimg with red oxide primer and applying two coats of synthetic enamel paint on the surface as per existing colour and making good any disturbed surface complete all as specified and directed.
Construction of valve chamber of size 1200 x 1200 x 1200 mm (internal dimensions) with the following specifications :- (i) 15cm thick PCC 1:4:8 type D-2 (using stone aggregate) as in foundation concrete. (ii) PCC solid block masonry 200 mm thick using grade C-5 block in CM 1:6 (iii) Rendering 15mm thick in CM 1:4 finished even and fair. (iv) PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in coping. (v) 3 mm thick MS sheet cover alongwith MS angle iron frame 40 x 40 x 6mm duly embedded in coping concrete with necessary locking arrangement. (vi) Painting MS sheet cover and frame with two coats of synthetic enamel paint over a coat of red oxide primer. (Note : Quoted rate shall be deemed to be inclusive of excavation in any type of soil and earthwork required as per site requirement.)
Goodluck Enterprises
Santosh Pandurang Pise
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .