Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.1 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹19.8 L+₹2.3 L (12.9%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹21.5 L+₹4.0 L (23.1%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹24.1 L+₹6.6 L (37.6%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹26.8 L+₹9.3 L (53.0%)Rejected-Finance 365 B 10 HENRY COMPLEX MATHIYAS NAGAR KP ROAD NAGERCOIL KANNIYAKUMARI DISTRICT 629001 | KANNIYAKUMARI | TAMIL NADU | 629001 | L5 | Rejected-Finance NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
1 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Minniebay
GE, Minniebay, Junglighat (PO), Port Blair -744103
REPAIR/MAINT OF LT DISTRIBUTION SYSTEM, OVER HEAD LINES, CABLES, CHANGE OVER PANEL CONTROL SWITCHES AND CONNECTED ITEMS AT INS UTKROSH UNDER AGE E/M NO II AT GE MINNIEBAY, PORT BLAIR
2020_MES_374129_1
8877/E8
Open Tender
Civil Works
Item Rate
365 days
GE, Minniebay, Junglighat (PO), Port Blair
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE, Minniebay, Junglighat (PO), Port Blair
₹60,000
Yes
9 Nov 2020
3 Sept 2020
6 Oct 2020
3 Sept 2020
1 Oct 2020
17 Sept 2020
60 days
Amount
Excavation in soft / loose soil not exceeding 1.5 mtr wide and n exc 1.5 mtr depth and getting out incl forming of bottom for laying cable all as specified and directed
Excavation in soft / loose soil not exceeding 1.5 mtr wide and exc 1.5 mtr depth and not exc 3.0 Mtr and getting out all as specified and directed
Excavation in hard / dense soil Iincluding road cutting etc not exceeding 1.5 mtr wide and n exc 1.5 mtr depth and getting out incl forming of bottom for laying cable all as specified and directed
Returning filling using excavated soil including spreading levelling, watering and well ramming in layers n exc 25 cms all as specified and directed
Removal of surplus excavated material n.exc 50 mtrs and depositing where directed at a level n.exc 1.5 mtrs above the starting point all as specified and directed
S & F in replacement on load change over switch 415 V, 4 pole, 100 A as per existing make and model suitable equivalent make as per list of make at PS complete all as specified and directed.
S&F in replacement on load change over switch 415 V, 4 pole, 125 A as per existing make and model suitable equivalent make as per list of make at PS complete all as specified and directed.
S&F in replacement on load change over switch 415 V, 4 pole, 160 A as per existing make and model suitable equivalent make as per list of make at PS complete all as specified and directed.
S&F in replacement on load change over switch 415 V, 4 pole,200 A open execution as per existing make and model suitable equivalent make as per list of make at PS complete all as specified and directed.
S&F in replacement on load change over switch 415 V, 4 pole, 250 A open execution as per existing make and model suitable equivalent make as per list of make at PScomplete all as specified and directed.
S&F in replacement on load changeover switch 415 V, 4 pole, 320A open execution as per existing make and model suitable equivalent make as per list of make at PScomplete all as specified and directed.
S&F in replacement on load changeover switch 415 V, 4 pole, 400A open execution as per existing make and model or suitable equivalent make as per list of make at PS complete all as specified and directed.
S&F in replacement MCCB, 415 volts, 4 pole adjustable thermal setting type 25 KA, 63 A as per existing make and model or suitable equivalent make as per list of make at PS complete all as specified and directed.
S&F in replacement MCCB, 415 volts, 4 pole adjustable thermal setting type 25 KA, 100 A as per existing make and model or suitable equivalent make as per list of make at PS complete all as specified and directed.
S&F in replacement MCCB, 415 volts, 4 pole adjustable thermal setting type 25 KA, 125A as per existing make and model suitable or equivalent make as per list of make at PS complete all as specified and directed.
S&F in replacement MCCB, 415 volts, 4 pole adjustable thermal setting type 25 KA, 160A as per existing make and model or suitable equivalent make as per list of make at PS complete all as specified and directed.
S&F in replacement MCCB, 415 volts, 4 pole adjustable thermal setting type 25 KA, 200A as per existing make and model or suitable equivalent make as per list of make at PS complete all as specified and directed.
S&F in replacement MCCB, 415 volts, 4 pole adjustable thermal setting type 25 KA, 250A as per existing make and model or suitable equivalent make as per list of make at PS complete all as specified and directed.
S&F in replacement MCCB, 415 volts, 4 pole adjustable thermal setting type 25 KA, 320A as per existing make and model or suitable equivalent make as per list of make at PS complete all as specified and directed.
S&F in replacement MCCB, 415 volts, 4 pole adjustable thermal setting type 25 KA, 400A as per existing make and model suitable or equivalent make as per list of make at PS complete all as specified and directed.
M&L for straight through jointing kits heat shrinkable type LT UG XLPE cable heavy duty armoured sheathed and making the disturbed surface after relaying the cable and making joints suitalbe for aluminium conductor of following size :- Note : Taking down the fult cable, excavation, returning filling, removal of surplus soil shall be measured and paid under relevant of this sch.
16 to 25 Sqmm 3.5 core
35 to 70 Sqmm 3.5 core
95 to 150 Sqmm 3.5 core
185 to 240 Sqmm 3.5 core
300 to 40 Sqmm 3.5 core
Supplying and laying in replacement of GI tubing medium grade for cable protection in trenches/duct/fixing to pole/wall or in such similar position of following size all as specified and directed:-
80 mm dia
50 mm dia
40 mm dia
S&F in replacement aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground all as specified and directed.
S&F in replacement galvanised iron strip 32 x 6 mm burried in ground all as specified and directed.
S&F in replacement air termination single pointed aluminium rod 12mm dia and 300mm long all as specified and directed.
S&F in replacement test point terminal block made of gun metal or phosphorous bronze size 75x75x25mm drilled and screwed includind 3 Nos 8mm dia, 25mm long hexagonal head screw all as specified and directed.
Taking up old unserviciable LT UG cables from trench/poles/wall etc of following size all as specified and directed:-
10 Sqmm 2 core
10 Sqmm 4 core
16 Sqmm 4 core
25 Sqmm 3.5 core
35 Sqmm 3.5 core
50 Sqmm 3.5 core
95 Sqmm 3.5 core
120 Sqmm 3.5 core
185 Sqmm 3.5 core
240 Sqmm 3.5 core
300 Sqmm 3.5 core
Supply and laying LT UG cable XLPE insulated armoured and PVC sheathed 1100 volts grade with aluminium conductor stranded of following sizes all as specified and directed :-
10 Sqmm 2 core
10 Sqmm 4 core
16 Sqmm 4 core
25 Sqmm 3.5 core
35 Sqmm 3.5 core
50 Sqmm 3.5 core
95 Sqmm 3.5 core
120 Sqmm 3.5 core
185 Sqmm 3.5 core
240 Sqmm 3.5 core
300 Sqmm 3.5 core
Supply & laying in replacement Telerex DWC (Double Wall Corrugated) HDPE pipe ISI marked of outer dia of 50 mm and inner dia 38 mm polethylene including couplers, bends, cap etc., with smooth internal and profiled external surface for non pressure under ground cable complete all as secified and directed
All as per item No 29 above but outer dia of 63 mm and inner dia 50 mm.
All as per item No 29 above but outer dia of 77 mm and inner dia 63 mm.
All as per item No 29 above but outer dia of 90 mm and inner dia 76 mm .
All as per item No 29 above but outer dia of 110 mm and inner dia 95 mm.
All as per item No 29 above here in before but outer dia of 120 mm and inner dia 103.5 mm.
All as per item No 29 above but outer dia of 160mm and inner dia 126 mm.
Earthing complete with GI earth electride of size 60cmx60cmx6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level wuith top edge of earth plate at a depth not less than 1.5 metre below normal ground surrounded from all sides by 15cm thick and packed layer of charcoal dust and conmmon salt filling in alternate layers cleaned connected to and including GI earth strip 32 x 6mm size upto 7.5 mtr by means of bolts, nuts, check nuts and washers made of galvanised iron and protected light grade 50mm dia 5 mtr long GI pipe connected to main control board and GI pipe light grade 20mm bore for watering and including funnel wire mesh, RCC pit cover 50mm thick with 10mm dia reinforcement 100mm c/c and PCC chamber pit with pcc 1:2:4 Type C2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 3 of SSR Part -I 2009
S & F in replacement of digital soft starter suaitable for 15 HP submersible pump removing existing un serviceable starter and fixing new with propper electrical connection including additional wiring etc complete all as specified and directed. Make: L & T , cat part No : CSXI-015-41 or equivalent make as per list of make at PS.
S & F in replacement of star delta starter suaitable for 10 to 12.5 HP submersible pump with propper electrical connection including additional wiring etc complete all as specified and directed. Make: L & T , Cat part No : MK 1 SASD,SS96255 or equivalent make as per list of make at PS.
M & L for grass cutting with Petrol Grass Cutting machine all around the E/M installations at INS Utkrosh area.
S&F in repairs aluminium cables lugs for cables of size upto 10 Sqmm including necessary crimping with crimping tool complete all as specified and directed
S&F in repairs aluminium cables lugs for cables of size upto 16 Sqmm including necessary crimping with crimping tool complete all as specified and directed
S&F in repairs aluminium cables lugs for cables of size upto 25 Sqmm including necessary crimping with crimping tool complete all as specified and directed
S&F in repairs aluminium cables lugs for cables of size upto 35 Sqmm including necessary crimping with crimping tool complete all as specified and directed
S&F in repairs aluminium cables lugs for cables of size upto 50 Sqmmm including necessary crimping with crimping tool complete all as specified and directed
S&F in repairs aluminium cables lugs for cables of size upto 70 Sqmmm including necessary crimping with crimping tool complete all as specified and directed
S&F in repairs aluminium cables lugs for cables of size upto 95 Sqmmm including necessary crimping with crimping tool complete all as specified and directed
S&F in repairs aluminium cables lugs for cables of size upto 125 Sqmmm including necessary crimping with crimping tool complete all as specified and directed
S&F in repairs aluminium cables lugs for cables of size upto 185 Sqmmm including necessary crimping with crimping tool complete all as specified and directed
S&F in repairs aluminium cables lugs for cables of size upto 240 Sqmmm including necessary crimping with crimping tool complete all as specified and directed
S&F in repairs aluminium cables lugs for cables of size upto 300 Sqmmm including necessary crimping with crimping tool complete all as specified and directed
S&F in repairs copper cables lugs for cables of size upto 25 Sqmm including necessary crimping with crimping tool complete all as specified and directed
S&F in repairs copper cables lugs for cables of size upto 35 Sqmm including necessary crimping with crimping tool complete all as specified and directed
S&F in repairs copper cables lugs for cables of size upto 50 Sqmm including necessary crimping with crimping tool complete all as specified and directed
S&F in repairs copper cables lugs for cables of size upto 70 Sqmm including necessary crimping with crimping tool complete all as specified and directed
M & L for repair of LT Panel board outdoor type repair/replace damged door hinges set of three nos front and back side and legs 40x40x6mm MS angle and necessary cutting,welding driling hole etc.works required at site complete all as specified and directed
M&L for providing cement concrete Type B1 1:2:4 (using 20mm graded stone aggregate ) as in hard standing after laying cable under road etc all as specified and directed.
Provn of services for finding out cable fault location for LT UG cable, XLPE insulated 1100 Volts, of any size with fault detector machine complete all as specified and as directed.
S&F in replacemnt of heavy duty resin filled capacitor 440 volt, 3 Ph of capacity upto 30 KVAR including connections and testing for proper functioning complete all as specified and directed.
S&F in replacement of APFC Controler upto 5 Step including connections and testing for proper functioning complete all as specified and directed.
S&F in replacement of digital Volt meter (0-500) including connections and testing for proper functioning complete all as specified and directed.
S&F in replacement of digital ammeter including connections and testing for proper functioning complete all as specified and directed.
S&F in replacement of Indicating Lamp R. Y. B (LED) Type including connections and testing for proper functioning complete all as specified and directed.
S&F in replacement of CTs of required rating including connections and testing for proper functioning complete all as specified and directed.
Supply, Install, Test and Commissioning of LT feeder pillar box outdoor type fabricated out of 3.0 mm thick CRCA sheet double door, CPRI approved complete with powder coating with seven tank process mounted on M.S angle Iron frame of size 40x40x6mm, duly grouted with PCC reqd with the following:- (a) S & F copper bus bar 300 Amp with cloured heat shrinkable insulated sleeve 415 Volts as per IS of suitable size mounted on DMC/epoxy insulator (not less than 50mmx50mm conicle type at a maximum interval of 500 mm- 01 Set. (b) S&F MCCB FP 200 Amps 25 KA - 01 No for main in coming
Supply, Install, Test and Commissioning of LT feeder pillar box outdoor type fabricated out of 3.0 mm thick CRCA sheet double door, CPRI approved complete with powder coating with seven tank process mounted on M.S angle Iron frame of size 40x40x6mm, duly grouted with PCC reqd. with the following:- (a) S & F copper bus bar 400 Amp with cloured heat shrinkable insulated sleeve 415 Volts as per IS of suitable size mounted on DMC/epoxy insulator (not less than 50mmx50mm conicle type at a maximum interval of 500 mm- 01 Set. (b) S&F MCCB FP 250 Amps 35 KA - 01 No For Main incoming
S&F pole cap made out of MS including one coat of aluminium paint over two coat of red oxide paint suitable for 8.5 / 9.0/ 11.0 mtr long tubular pole including threaded hole 3 Nos and suitable size of nut and bolts complete all as specified and directed.
M &L for painting to existing steel tubular poles 9 mtr long including cross arms etc. with one coat of aluminium paint including preparation of surfaces and feeder name and pole number complete all as directed.
Material & Labour for painting to feeder pillar box / LT panel & duct cover etc, including angle iron frame with two coats of grey or colour as approved by GE / Engr in -Charge as per site suitability synthetic enamel paint including door welding with hinges complete as specified and directed
ICON AGENCIES
SHUSHANT ASSOCIATES
SRI HARSHITA ELECTRICALS
M/s Power Engineering Co
Hindustan Traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .