Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 LAccepted-AOC 00 VILL RATI KA NAGLA SIKANDRA RAO ROAD INDUSTRIAL HATHRAS UTTAR PRADESH 204212 | HATHRAS | UTTAR PRADESH | 204212 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹9.3 L+₹87,437 (10.4%)Rejected-Finance 02 JAMEEWAR COMPLEX RING ROAD HANUMAN NAGAR GONDIA MAHARASHTRA 441614 | GONDIA | MAHARASHTRA | 441614 | L2 | Rejected-Finance Being not lowest |
Tender Value
₹8.5 L
EMD Value
₹17,000
Closing Date
3 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Pranav, AGE (I)
AGE (I) Manauri Prayagraj-212212
REPAIR / MAINT OF LT EXTERNAL ELECTRIC SUPPLY NETWORK SYSTEM, VARIOUS CABLES, PANELS AND CONNECTED ITEMS AT NEW PROJECT AREA UNDER AGE (I) AF MANAURI
2023_MES_599751_1
9074/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Manauri
As per tender docs
7 documents required · 7 mandatory
₹500
AGE (I) AF Manauri
₹17,000
Yes
5 Aug 2023
31 May 2023
5 Jul 2023
31 May 2023
3 Jul 2023
14 Jun 2023
Amount
Excavation in trenches not exc 1.5 M wide and not exc 1.5 M in depth for pipe line, etc getting out in soft/ loose soil and levelling of bottom surface to required level complete all as specified & directed.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 CM complete and as directed.
Removal of surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified & directed.
Supply, laying and spreading of dry (Ganga) sand, free from organic impurities for cushioning as in trenches 8cm depth below cable and 15cm above cable and punned to 10cm depth complete all as specified & directed. Note :- Punned thickness shall be considered for measurement purpose.
M&L brick, sub class 'B' bricks laid dry, flat, length equal to width of brick over sand cusioning in trenches for cable protection complete all as specified and directed
Labour only for reuse of serviceable bricks obtained from item No 1.00 complete all as specified & directed.
Material & labour for cutting /boring to plinth protection/ hard standing / road etc in suitable depth to across the GI pipe size upto 80 mm dia of bore for drawn through XLPE under ground cable for giving mechanical protection to cable complete all as directed. (Note : Quoted rate shall be included the cost of required material for repairing to disturbed surface complete all as per existing site complete all as specified & directed.
M&L in replacement to GI tubing light grade 80 mm dia of bore with all fitting laid in trenches across the road or fixed with pole/ surface of wall etc as site with required fixing accessories complete all as specified and directed. (Make : Tata or Jindal or Swastic)
S&F galvainesd water tubing light grade 50 mm dai of bore with fix with pole/ surface of wall / laid in trench etc as site using 02 Nos clamp made out by GI strip in size 25x4 mm with nut bolt and washer etc complete all as specified & directed.
Supply, laid in trench /fixed in replacement with surface of wall/roof etc jointing, thimbling and glanding in suitable size testing to cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric LT cable with alumunium conductor 1100 volts, grade cross section area 3.5 core x 25 Sqmm (earthed) complete all as specified and directed. Make- Havells/ Finolex/ RPG/ Polycab/ Paragon/ Fort Gloster
Supply, laid in trench /fixed in replacement with surface of wall/roof etc jointing, thimbling and glanding in suitable size testing to cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric LT cable with alumunium conductor 1100 volts, grade cross section area 3.5 core x 35 Sqmm (earthed) complete all as specified and directed. Make- Havells/ Finolex/ RPG/ Polycab/ Paragon/ Fort Gloster
Supply, laid in trench /fixed in replacement with surface of wall/roof etc jointing, thimbling and glanding in suitable size testing to cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric LT cable with alumunium conductor 1100 volts, grade cross section area 3.5 core x 50 Sqmm (earthed) complete all as specified and directed. Make- Havells/ Finolex/ RPG/ Polycab/ Paragon/ Fort Gloster
Supply, laid in trench /fixed in replacement with surface of wall/roof etc jointing, thimbling and glanding in suitable size testing to cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric LT cable with alumunium conductor 1100 volts, grade cross section area 3.5 core x 150 Sqmm (earthed) complete all as specified and directed. Make- Havells/ Finolex/ RPG/ Polycab/ Paragon/ Fort Gloster
Supply, laid in trench /fixed in replacement with surface of wall/roof etc jointing, thimbling and glanding in suitable size testing to cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric LT cable with alumunium conductor 1100 volts, grade cross section area 3.5 core x 16 Sqmm (earthed) complete all as specified and directed. Make- Havells/ Finolex/ RPG/ Polycab/ Paragon/ Fort Gloster
Supply, laid in trench /fixed in replacement with surface of wall/roof etc jointing, thimbling and glanding in suitable size testing to cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric LT cable with alumunium conductor 1100 volts, grade cross section area 2.00 core x 10 Sqmm (earthed) complete all as specified and directed. Make- Havells/ Finolex/ RPG/ Polycab/ Paragon/ Fort Gloster.
Labour for re-laying, connecting, jointing, thembling using in suitable size and cramping etc to serviceable XLPE insulate LT cable in all specification incl brick (re-use) and sand (Provided fresh) etc all as per existing complete with other site required works complete all as specified and directed. Note: Sand cushioning punned dept shall be measured and paid separately under respective items.
Supply, install, testing and commissioning of LT panel size 90 cm x 80 cm x 40 cm enclosures cubical weather and vermin proof totally enclosed made out of 3.15 mm thick CRCA sheet machine pressed of suitable size to operate on 3 phase 4 wire system 415 Volts, 50HZ double door with front and rear openable with locking arrangement incl inner shutters for mounting switch gear etc, bottom gland plate with sufficient numbers of circular cable entry holes, including PCC work, prewired complete duly powder coated with comprising of the following :-
Supply, install, testing and commissioning of LT panel size 80 cm x 80 cm x 30 cm enclosures cubical weather and vermin proof totally enclosed made out of 3.15 mm thick CRCA sheet machine pressed of suitable size to operate on 3 phase 4 wire system 415 Volts, 50HZ double door with front and rear openable with locking arrangement incl inner shutters for mounting switch gear etc, bottom gland plate with sufficient numbers of circular cable entry holes, including PCC work, prewired complete duly powder coated with comprising of the following :-
Taking down old unsv DB and supply and fixing Busbar chamber TPN current capacity 63 Amp 04 way horizental type, total enclosed with porcelain Insulator and colour coated tinned copper bus bar with suitable size of legs including PCC work fixing on ground or on wall/pole with suitable size of clamp, Nut, bolts, suitable size of thimbles for connection etc. complete all as specified & directed. Make: Havells Cat part No IHBC006304 or equivalent in L&T/Standard/ABB/Indoasian
S&F LT cable junction box dust and water proof made out of PVC non metallic sheet FRP type, factory made out of PVC non metalic sheet FRP type, factory made, size of box 250mm x 200 mm x 100 mm deep with swivelling cover and locking clamp, MS clamps and nuts, bolts, for fixing the box on steel tubular pole, consisting of aluminium bus bar strip 150mm x 30 mm x 3 mm - 04 nos mounted on pole complete all as specified and directed. Make: Sintex CAT part No GS-JB2520 or equivalent CAT part of make Henson.
M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick surrounded with charcoal and salt, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead using GI earth strip in size 32 x6 mm means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as specified & directed.
(i) The concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I. (ii) Item includes the cost of 7.50m GI pipe for protection of earth wire/strip Any variation in length shall be adjusted through deviation order. (iii) Item includes cost of 7.50m earth lead wire/strip. Any variation in length shall be adjusted through deviation order. (iv) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate.
Supply, jointing, commissioning and testing in replacement heat shrinkable end termination /straight through jointing kit suitable for 1100 volt grade (Earthed) cable for outdoor type complete with jointing material and required accessories suitable for underground XLPE cable of size 4 Core x 50 Sqmm (earthed) complete all as specified and directed. Make: Dension/3M/Rahycam or make as mentioned in Appx 'B' of PS.
Supply, jointing, commissioning and testing in replacement heat shrinkable end termination /straight through jointing kit suitable for 1100 volt grade (Earthed) cable for outdoor type complete with jointing material and required accessories suitable for underground XLPE cable of size 4 Core x 150 Sqmm (earthed) complete all as specified and directed. Make: Dension/3M/Rahycam or make as mentioned in Appx 'B' of PS.
Note :- (i) Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. The contract amount shall be arrived at after deduction of Schedule of Credit from the total quoted amount in BOQ. (ii) Make of material shall be as per mentioned in Particular specifications or Appendix 'B' to Particular specifications as approved by AGE (I) AF manauri
M/S R S Traders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .