Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.9 LAccepted-AOC 194A LUKER GANJ ALLAHABAD UP | ALLAHABAD | ALLAHABAD | UP | 211001 | L1 | Accepted-AOC Found lowest bidder | |
| 2 | L2₹24.9 L+₹2.4 L (10.5%)Rejected-Finance 114 SHASTRI NAGAR MEERUT | MEERUT | UTTAR PRADESH | 245206 | L2 | Rejected-Finance 2nd lowest | |
| 3 | L3₹27.9 L+₹5.4 L (24.1%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L3 | Rejected-Finance 3rd lowest | |
| 4 | L4₹33.5 L+₹11.0 L (48.8%)Rejected-Finance | L4 | Rejected-Finance 4th lowest | |
| 5 | L5₹39.8 L+₹17.3 L (76.8%)Rejected-Finance H NO 206 RAJAPUR DUJANIA MOHALLA DASNA DEHAT VILLAGE TOWN INDERGARHI CITY GHAZIABAD GHAZIABAD UTTAR PRADESH 201002 INDIA | GHAZIABAD | UTTAR PRADESH | 201002 | L5 | Rejected-Finance 5th lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
29 Apr 2024, 6:00 pmClosed
GE (North) Meerut Cantt
GE (North) Meerut Cantt
MAINT AND REPAIR TO INTERNAL ELECTRIFICATION AND CONNECTED WORKS IN MD ACCNS OF DOGRA FARM, ISHWAR NAGAR GURUBACHAN ENCLAVE, RAINA ENCLAVE, CEMENTRY LINE, ROORKEE ROAD, ROORKEE ROAD MES QTRS, UMRAO SINGH ENCLAVE, RA BAZAR AOT, JADUNATH ENCLAVE CHANDI
2024_MES_648688_1
8501/E8
Open Tender
Civil Works
Item Rate
240 days
Meerut
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (North) Meerut Cantt
₹90,000
Yes
19 Jun 2024
30 Mar 2024
1 May 2024
30 Mar 2024
29 Apr 2024
15 Apr 2024
Amount
Taking down copper/ aluminium point wiring (ligh, fan, bell, socket or power etc.) complete with all accessories like switches, sockets, regulators, ceiling roses, light fittings etc. for taking credit and making good disturbed surfaces, applying distemper / Emulsions matching to the existing colour / quality of walls / floors / ceiling etc complete all as specified and directed. NOTE-Industrial bldg height approx 30 feets and all T & P arrangements will be done at contractor end , no crane facility will be provied for any item in contract.
Taking down carefully all type of sub main wiring any core including batten / conduit and making good to disturbed surface as matching to existing complete all as specified and directed.
M&L for concealed point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi stranded, FRLSH, conforming to IS: 694-1990 PVC insulated, unsheathed copper conductor cable FRLSH in and including PVC conduit of 20 mm dia or higher, medium grade complete with and including all PVC conduit accessories / fittings, brass screws, washers etc, alongwith frame inner plate suitable for fixing moduler switches, sockets, regulator etc or with 3mm thick plastic laminated sheet top cover concealed in wall any height with and including continuous green earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated copper conductor cable, unsheathed and connected to common earth and earth dolly including cutting holes in or through the walls, making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match complete all as directed for One light/fan/bell point wiring controlled by one, one way switch/bell push button. The point wiring shall include the wiring of light/ outlets of any length from the distribution board via switch to the point.
-ditto- but one out let socket point 3pin 5 amps on independent board.
-ditto- but on the same board with other switches
All as per Srl item No 3 as per above here-in-before but using 2.5 sqmm copper conductor for with 2.5 sqmm earth wire for one 15 amps socket outlet on independent board complete all as specified and directed.
All as per Srl item No 3 as per above here-in-before but on the same board with other switches
All as per Srl item No 3 as per above here-in-before but using 4 sqmm copper conductor for with 4 sqmm earth wire for one 20 amps socket outlet on independent board all as directed.
All as per Srl item No 8 as per above here-in-before but on the same board with other switches
All as per Srl item No 3 as per above here-in-before but for supply and drawing 1.5 sqmm copper conductor cable with one 1.5 sqmm continuous earth wire into existing conduit any type after taking out the existing wiring including replacement of required size of terminal box with 3mm thick bakelite sheet cover fixed with brass screws all as directed for One light/fan/bell point wiring controlled by one, one way switch/bell push button complete all as specified and directed.
-ditto- but one out let socket point 3pin 6 amps on independent board.
-ditto- but on the same board with other switches
All as per Srl item No 10 as per above here-in-before but using 2.5 sqmm copper conductor and with 2.5 sqmm earth wire for one 15 amps socket outlet on independent board all as directed.
All as per Srl item No 10 as above here-in-before but using 4 sqmm copper conductor and with 4 sqmm earth wire for one 20 Amps socket outlet on independent board complete all as specified and directed.
M & L for submain wiring with two single core 6 sq mm nominal area with 1100 volt grade confirming to IS 694 (2010) PVC insulated unsheathed with one run of 6 sq mm multi stranded copper conductor cable (FRLSH) ISI marked for continuous green earth wire drawn in and including concealed rigid non-metallic PVC conduit (ISI mark) of size 19/20 mm dia medium grade with all fitting marked including cutting, chasing for conduit and making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match complete all as directed. Note:- Two runs of 6 Sqmm Cable and one run of 6 Sqmm cable together in & including PVC conduit shall be measured as one RM.
M & L for submain wiring with four single core 6 sq mm FRLSHnominal area for 3 phase & neutral with 1100 volt grade confirming to IS 694 (2010) PVC insulated unsheathed with one run of 6 sq mm multi stranded copper conductor cable (FRLSH) ISI marked for continuous green earth wire drawn in and including concealed rigid non-metallic PVC conduit (ISI mark) of size 19/20 mm dia medium grade with all fitting marked including cutting, chasing for conduit and making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match complete all as directed. Note:- Four runs of 6 Sqmm Cable and one run of 6 Sqmm cable together in & including PVC conduit shall be measured as one RM.
M & L for submain wiring with two single core 10 sq mm nominal area with 1100 volt grade confirming to IS 694 (2010) PVC insulated unsheathed with one run of 10 sq mm multi stranded copper conductor cable (FRLSH) ISI marked for continuous green earth wire drawn in and including concealed rigid non-metallic PVC conduit (ISI mark) of size 19/20 mm dia medium grade with all fitting marked including cutting, chasing for conduit and making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match complete all as directed. Note:- Two runs of 10 Sqmm Cable and one run of 10 Sqmm cable together in & including PVC conduit shall be measured as one RM.
M & L for submain wiring with four single core 10 sq mm FRLSHnominal area for 3 phase & neutral with 1100 volt grade confirming to IS 694 (2010) PVC insulated unsheathed with one run of 10 sq mm multi stranded copper conductor cable (FRLSH) ISI marked for continuous green earth wire drawn in and including concealed rigid non-metallic PVC conduit (ISI mark) of size 19/20 mm dia medium grade with all fitting marked including cutting, chasing for conduit and making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match complete all as directed. Note:- Four runs of 10 Sqmm Cable and one run of 10 Sqmm cable together in & including PVC conduit shall be measured as one RM.
S&F Modular Switch, 1 module, 6A, AC, 240V, one way ISI Marked complete all as specified and directed..
S&F Modular Socket, 2 module, 6A, 3 pin combined, AC, 240V, ISI Marked complete all as specified and directed..
S&F Modular Socket, 2 module, 6A / 16A, 2/3 pin combined, AC, 240V, ISI Marked complete all as specified and directed..
S&F Modular Switch, 1 module, 16A, AC, 240V, one way ISI Marked complete all as specified and directed..
S&F modular outer plate with frame 1/2 module suitable for modular switch & board complete all as specified and directed.
-ditto - but 3 module
-ditto - but 4 module
-ditto - but 6 module
-ditto - but 8 module
-ditto - but 12 module
-ditto - but 18 module
Supply and fix anodised rust proof, 18 SWG, GI box ,flush type of following sizes suitable for modular switches and sockets recessed in wall /gypsum partition complete all as specified & as directed :-
1 module / 2 Module
-ditto - but 3 module
-ditto - but 4 module
-ditto - but 6 module
-ditto - but 8 module
-ditto - but 12 module
-ditto - but 18 module
S&F switch piano flush type, 5A, AC, 240V, one way ISI Marked complete all as specified and directed.
S&F switch piano flush type,15A, AC, 240V, one way ISI Marked complete all as specified and directed.
S&F Bell Push, Flush type, 5A, AC, 240V, ISI Marked complete all as specified and directed.
S&F socket outlet flush type, 5A, 5pin, AC, 240V ISI Marked complete all as specified and directed.
S&F socket outlet flush type, 15A, 6pin, AC, 240V ISI Marked complete all as specified and directed.
S&F Modular 5 Step Fan Regulator, 2 module, 120W, AC, 240V, ISI Marked complete all as specified and directed..
S&F in repairs modular type lamp holder B22 base, PVC / Polycarbonate type with batten back plate, AC, 240V, Pin type, ISI marked complete all as specified and directed..
S&F in repairs lamp holder, angular/ straight ,PVC / Polycarbonate type with batten back plate, AC, 240V, Pin type, ISI marked complete all as specified and directed.
S&F in repairs modular Power Unit 32 A, 3pin, AC, 240V ISI Marked incl PVC Box complete all as specified and directed.
S&F in repairs Ceiling rose surface Bakelite 65x50mm, 3 terminals, AC, 240V, ISI Marked complete all as specified and directed.
S&F in repairs Call Bell, AC, 240V, SP, ISI Marked complete all as specified and directed.
S & F in repair 36W LED recessed mounted 2'X2' panel light having CRCA sheet housing, PC diffuser, luminous efficacy of 100 lumen/W, CRI > 80, PF ≥ 0.9, CCT 6500K/3000K, independent isolated SMPS based constant current electronic LED driver with THD < 20%,built-in surge voltage protection min 2.5kV and other safety tests as per IS 15885 (Part-2/Sec-13): 2012, IP 20 protection, input voltage range 140- 270V , input frequency 50- 60 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed by the Engineer-in-charge.
S & F 20 W surface / wall mounted, 4 feet LED T-5 batten having PC diffuser, luminous efficacy of ≥100 lumen/W, CRI > 80, PF > 0.9, CCT 6500K, independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS 15885 (Part-2/Sec-13): 2012, housed in PC with white coloured ABS end caps, IP 20 protection, input voltage range 140- 270 V, input frequency 50- 60 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed by the Engineer-in-charge.
S & F 20 W surface / wall mounted,single rod 4 feet LED T-8 batten having luminous efficacy of ≥100 lumen/W, CRI > 80, PF > 0.9, CCT 6500K, independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser,CRCA housing with white coloured ABS end caps, IP 20 protection, input voltage range 140- 270 V, input frequency 50- 60 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed by the Engineer-in-charge.
S&Fin repairs Retrofit polycarbonate diffuser type 20 watt retrofit LED tube rod 4 feet,100Lm/Watt,CRI >80, PF >0.90, operating volatage 140- 240V complete all as specified and directed.
S&F in repairs, Wall mounting focus light with polycarbonate diffuser prewired incl 14/15 Watts LED lamp complete all as specified and directed.
S&F in repairs, Wall mounting fancy / round light fitting with polycarbonate diffuser prewired incl 9 Watts LED lamp complete all as specified and directed.
S&F in repairs, bulkhead light post light outdoor fitting with polycarbonate diffuser prewired incl 12/15 Watts LED lamp complete all as specified and directed.
S&F in repairs, fancy mirror light with polycarbonate diffuser prewired incl 14/15 Watts LED lamp complete all as specified and directed.
S&F in repairs pressure die-cast alluminium housing 18 Watt LED flush / surface/reccesd mounting down light luminaire powder coated finish in round or square shape with integral electronic driver THD<10% complete all as specified and directed..
S&F in repairs pressure die-cast alluminium housing 12 Watt LED flush / surface/reccesd mounting down light luminaire powder coated finish in round or square shape with integral electronic driver THD<10% complete all as specified and directed..
S & F 10 W surface / wall mounted, 2 feet LED T-5 batten having PC diffuser, luminous efficacy of ≥100 lumen/W, CRI > 80, PF > 0.9, CCT 6500K, independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in PC with white coloured ABS end caps, IP 20 protection, input voltage range 140- 270 V, input frequency 50- 60 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed by the Engineer-in-charge.
S&F in repairs 25 Watt pewired pressure die cast housing LED bldg security light luminaire IP 66 ingress protection ,Efficacy 120lm/watt ,built-in surge protection,electronic driver incl suitable OD GI pipe bracket, mounting clamps with nuts, bolts and washers, electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose/junction box to the fixture complete all as specified and directed by the Engineer-in-charge.
a) All as per Srl item No 60 as above here-in-befor but 35 Watts.
S&F in repairs 50 Watt pewired pressure die cast LED flood light luminaire IP 66 Efficacy 120lm/watt incl suitable OD GI pipe bracket, two nos mounting clamps with nuts, bolts and washers complete all as specified and directed.
S&F in repairs LED Driver suitable for any make or model LED street light fitting 25 to 60 Watts, 240V complete all as specified and directed.
-ditto- but suitable for 2'x2' ceiling light 36/45 watts
-ditto- but suitable for 12/18 Watts down lighter
S&F 15 watt LED bulb 2 pin B22 base,100 Lumems per watt,PF≥0.9, 180° wide beam angle voltage surge protection 4kV ,6500K cool white,operating voltage 100-240V complete all specified and directed.
-ditto- but 20 Watts.
-ditto- but 12 Watts warm white
-ditto- but 9 Watts
S&F in repair Metallic Enclosure, SPN double door DB, IP43, door earthing,isolated neutralbar ,240V, AC, 4 way, with 200 Amps rated busbar ISI Marked complete all as specified and directed.
-ditto- but 06 way
-ditto- but 08 way
-ditto- but 10 way
-ditto- but 12 way
ditto but TPN DB, vertical mounting,, 4way with 200Amps rated busbar, double door
-ditto- but VTPN DB, incomer MCCB type, 415V, 4way with 200Amps rated busbar, double door.
S&F in repair MCB SP 6 to 32 A, AC, 240V, 10KA, ISI Marked complete all as specified and directed.
S&F in repair Isolator DP, 40A, AC, 240V, ISI/CE Marked conforming to IEC 60947-3,biconnect terminals complete all as specified and directed.
-ditto- but 63A
S&F in repair Isolator 4P, 63A, AC, 415V, ISI/CE Marked complete all as specified and directed.
-ditto- but 100A
-ditto- but 125A
S&F in repairs 1 module SPN metallic enclosure with a two pin and earth plug and socket with one MCB SP 20 Amps complete all as specified and directed.
S&F in repairs, 4 Pole MCCB 63 Amp, 50 Hz, 415 V with rupturing capacity 18KA with Thermal - Magnetic Released complete all as specified and directed.
All as per Srl item No 84 as above here-in-befor but 100Amps 18KA
S&F in repair 1100V grade PVC sheathed flexible two core cable with multistranded copper conductor of size 1.5Sqmm, ISI Marked complete all as specified and directed
S&F in repair copper cable 1.5 Sqmm copper multistandard PVC insulated FR, 1100V grade complete all as specified and directed
S&F in repair copper cable 2.5 Sqmm copper multistandard PVC insulated FR, 1100V grade complete all as specified and directed
S&F in repair copper cable 4 Sqmm copper multistandard PVC insulated FR, 1100V grade complete all as specified and directed
S&F in repair copper cable 6 Sqmm copper multistandard PVC insulated FR, 1100V grade complete all as specified and directed.
Supply only insulation tape roll 20 mm wide 15 Mtr long ISI mared all as directed. Make: Steelgrip / Kinjal / Anchor complete all as specified and directed. Make - kinjal/steel grip/anchor
S/F in repairs, 1100 volts grade heavy duty PVC sheathed stranded Aluminium conductor twin core cable flat or circular of size 10 Sqmm.
S&F in repairs, incl clamping and fixed to wall / pole / channels, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables with stranded aluminium conductor, 1100 volts grade, 6 Sqmm 2 core complete all as specified and directed.
All as per Srl item No 93 as above here-in-befor but 10 Sqmm 2 core
All as per Srl item No 93 as above here-in-befor but 16 Sqmm 2 core
All as per Srl item No 93 as above here-in-before but 16 Sqmm 4 core
All as per Srl item No 93 as above here-in-before but 25 Sqmm 3.5 core
All as per Srl item No 93 as above here-in-before but 35 Sqmm 3.5 core
S & F cable tray , 4' non perforated type, 1.6mm thick GI sheet, completed all as specified and directed.
M & L for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level steel earth plate connected with GI wire 04mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No.3 of SSR part I connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 150mm center to centre both way with suitable lifting handle and pit / chamber in PCC 1:3:6 type C1 , for pit cover including testing on completion complete all as specified and directed
M&L for taking down and refixing back of any height after servicing, repair and replacement of unserviceable parts, including opening of fan body, cleaning, separating serviceable parts for reuse / refix same after repairing and replacing any defecive parts witth new one such asBall / Bush Bearing, Metal Clamps,down rod split pin,screw,connector,ms nut bolt,armature,clutch,bottom/top cover , canopies, etc. reassembling, greasing complete all as specified and removal of existing paint properly and applyin 2 coats of spray paint of over a coat of red oxidide primer with writing the MES Nos., directed for Ceiling Fan 1200mm Sweep of any make or model complete all as specified and directed Note for item No 102 to 107: Supply only new spares shall be measured and paid seperately. Minor spares and consumables like small screws, washers, grease, cleaning agents, consumables etc. is deemed to be included in the cost
All as per Srl item No 101 as above here-in-before but Ceiling Fan 1400mm Sweep of any make or model
All as per Srl item No 101 as above here-in-before but Wall / Cabin Fan 400 / 450mm Sweep of any make or model
All as per Srl item No 101 as above here-in-before but Exhaust Fan 250/300mm Sweep of any make or model
M & L for rewinding including taking down and refixing the fans of any make, any model, from a reputed workshop, removing the burnt winding, cleaning slots, re-winding the motor with super enameled copper wire of size equivalent to the original winding including insulated packing materials, Varnishing, Drying etc, replacement of body screws, testing and commissioning on full load for 4 hrs continuous running all as directed for Ceiling Fan 1200mm Sweep of any make or model complete all as specified and directed
All as per Srl item No 105 as above here-in-before but Exhaust Fan 250 mm Sweep of any make or model
All as per Srl item No 105 as above here-in-before but Exhaust Fan 300mm Sweep of any make or model
S&F in repairs fan Condenser 2.5 mfd 240 Volts ISI marked complete all as specified and directed
All as per Srl item No 108 as above here-in-before but 3.15 mfd
All as per Srl item No 108 as above here-in-before but 4 mfd
S&F in repairs Fan blades made out of not less than 1.2mm thick Aluminium alloy and MS screws duly balanced & spray painted with White or Brown colour, Set of three, suitable for 1200mm sweep ceiling fans of any type, any make complete all as specified and directed
All as per Srl item No 111 as above here-in-before but 1400mm Sweep
S&F in repair BLDC ceiling fan 1200mm sweep 220CMM air delivery,with/without ,BEE 5 star energy rated minimum service value≥6,RPM not more than 280,copper winded motor ,anti rust powder coated aluminium blade,double ball bearing, dynamically balanced including canopy,down rod,shackel assembly,safety pin,nut bolt etc electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose/junction box to the fixture complete incl taking down old u/s one and depositing to MES Storeyard all as specified and directed by the engineer-in-charge.
S&F in repair PVC exhaust fan, 250mm sweep with lovers, AC, 230V incl taking down old u/s one and depositing to MES complete all as specified and directed
All as per Srl item No 114 as above here-in-before but sweep 300mm.
Carrying out electrical maint work of day to day internal electrical complaints such as repairs/rectrification/replacement of defective items ,no light / supply disruption complaints , fault findings etc.as per complaints recived in complaint cell register as per ground requirements by providing skilled electrician at any location under GE (N) Meerut AOR complete all as specified and directed. NOTE :- Stores required will be measured seprately.
Jain Traders
K S Enterprises
NITHYA INFRATECH
PARADISE INFRA POWER COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .