Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹20.1 L+₹3.6 L (22.1%)Rejected-Finance G 86 DATA RAM SECTOR 18 ROHINI NEW DELHI DELHI 110085 | NORTH WEST DELHI | DELHI | 110085 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹22.6 L+₹6.1 L (36.8%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹22.6 L+₹6.1 L (37.0%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹22.6 L+₹6.1 L (37.3%)Rejected-Finance A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
8 Jun 2023, 6:00 pmClosed
GE (NORTH) DELHI CANTT
GE (NORTH) DELHI CANTT
REPAIR MAINT OF INTERNAL ELECTRICATION WORK INCL REPLACEMENT OF UNSV DISTRIBUTION BOARDS MCCBS BLDG SECURITY LIGHTS WIRING LIGHT FITTINGS FIXTURES SUBMAIN WIRING ETC OF OTM ACCN AT INSIDE AT 505 ABW AND OTM ACCN 226 ASC AND 19 BIHAR AREA UNDER GE N
2023_MES_593547_1
CA NO. GE/NORTH-24/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE (NORTH) DELHI CANTT
As per NIT
2 documents required · 2 mandatory
₹500
Yes
GE (NORTH) DELHI CANTT
₹70,000
Yes
23 Jun 2023
6 May 2023
10 Jun 2023
6 May 2023
8 Jun 2023
2 Jun 2023
Amount
Taking down carefully copper / aluminium point wiring (light / fan socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc for taking credit including making good the disturbed surfaces to match with the existing complete all as specified and directed.
M&L for point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc and making good to the disturbed surfaces to match the existing complete all as specified and directed for One light / bell / buzzer point controlled by one, one way switch 06 Amps.
All as per the description of srl item No 02 here-in-before but one fan point controlled by one, one way switch 06 Amps.
All as per the description of srl item No 02 here-in-before but one 3 pin, 06 Amps socket outlet point on independent board controlled by one, one way 06 Amps switch.
All as per the description of srl item No 02 here-in-before but one 3 pin, 06 Amps socket outlet point on same board controlled by one, one way 06 Amps switch.
All as per the description of srl item No 02 above but point wiring with 2.5 Sqmm single core FRLS cables and earth continuity wire of 2.5 Sqmm single core FRLS cable for one 3 pin 15 Amps socket out let point controlled by one, one way switch on independent board complete all as specified and directed.
S&F of switch piano flush type, 06 Amps, single pole, one way, 230 volts complete all as specified and directed.
S&F of bell push, flush type, 06 Amps, 230 volts with switch frame complete all as specified and directed.
S&F of switch piano flush type, 16 Amps, single pole, one way, 230 volts with switch frame complete all as specified and directed.
S&F of socket outlet 2 in 1, 5 pin, 06 Amps, flush type, 230 volts with socket frame complete all as specified and directed.
S&F of socket outlet 2 in 1, 3 pin, 06 Amps and 3 pin, 16 Amps, flush type, 230 volts with socket frame complete all as specified and directed.
S&F of ding dong bell, AC, 230 volts, single pole complete all as specified and directed.
S&F of ceiling fan regulator, stepped type of 0 to 04 rotary steps, electronic, humfree, AC, 230 volts, 100 watts complete all as specified and directed.
S&F of ceiling rose, 6 Amps, 230 volts, AC, ISI marked with three equal size terminals and PVC / Polycarbonate insulated body of 50 x 25mm size complete all as specified and directed.
Supply and fix in repair of lamp holder, PVC / Polycarbonate type with back plate suitable for batten fitting including 9W LED bulb complete all as specified and directed.
S&F in repairs 10/12W LED TL fitting (2 fit) attractive wall mounted type suitable for mirror fittings, all accessories pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size complete all as specified and directed.
S&F in repairs on wall / ceiling LED batten lighting fixture 20 watts LED 5700K (4'), with extruded aluminium heat sink, integrated electronic driver and all accessories pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size with connector block complete all as specified and directed.
S&F in repairs of decorative wall mounting light SS finish fixture with extruded glass difuser suitable for up to 40 watt mini glass lamp, lamp holder, including 9 Watts LED bulb for fixing in decorative wall mounting light and all accessories pre-wired including connecting up including taking down of existing unserviceable light fitting complete all as specified and directed.
S&F in repairs Supply and fixing LED luminaire 600mm x 600mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete complete all as specified and directed.
S&F in repairs of LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. pre-wired including connecting up with PVC insulated copper conductor cable 1.5 Sqmm, 3 core as required for connections and 50mm bore light grade G. I. tube mounting bracket of 1.5 meter in length, bend to shape at 140 degree in ‘L’ shape and fixed to wall by means of 02 nos. of 40 x 5mm flat iron clamps, nuts, bolts & washers complete all as specified and directed.
Taking down of existing u/s highbay lights and Supply and fixing LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp. and all accessories complete, arrangements for mounting of fitting i.e. bracket, clamps, nuts, bolts and washers etc all as per site requirement including connecting up with provision of PVC insulated copper conductor cable 1.5 Sqmm, 3 core as required for connections complete all as specified and directed.
Taking down of existing unserviceable highbay lights and Supply and fixing LED flood light 150 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp. and all accessories complete, arrangements for mounting of fitting i.e. bracket, clamps, nuts, bolts and washers etc all as per site requirement including connecting up with provision of PVC insulated copper conductor cable 1.5 Sqmm, 3 core as required for connections complete all as specified and directed.
Material and labour for sub main wiring with 04 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable with and including continuous earth wire of size 4 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable drawing into and including rigid non-metallic PVC concealed conduit of 25mm dia, medium grade with all conduit accessories and connected to common earth dolly with suitable copper lugs including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified & directed, including taking down old sub main wiring. Note:- Two run for phase and neutral & earthing for continuous as earth wire.
All as per the description of srl item No 23 above but for 02x1.5 Sqmm for phase & neutral and 01x 1.5 Sqmm for continuous earth wire Note:- Two run for phase and neutral & earthing for continuous as earth wire.
All as per the description of srl item No 23 above but 06 Sqmm nominal cross sectional area and 01x 6 Sqmm for continuous earth wire Note:- Two run for phase and neutral & earthing for continuous as earth wire.
All as per the description of srl item No 23 above but 10 Sqmm nominal cross sectional area, four single core, with and including continuous earth wire of size 10 Sqmm nominal cross sectional area. Note:- Three run for phase, one run for neutral & earthing for continuous as earth wire.
S&F in repairs industrial type SPN enclosure with a two pin and earth plug and socket complete with and including MCB, SP, AC, 230 volts of 20 Amps, 'C' curve 10 KA breaking capacity and flush to wall including all cuttings & chases etc in wall and making good to the disturbed surfaces to match the existing complete all as specified and directed.
S&F in repairs industrial type TPN enclosure with a three pin and neutral and earth plug and socket complete with and including 32 Amps MCB, four pole, AC, 415 volts and flush to wall including all cuttings & chases etc in wall and making good to the disturbed surfaces to match the existing complete all as specified and directed.
S&F in repairs industrial type TPN enclosure with a three pin and neutral and earth plug and socket complete with and including 63 Amps MCB, four pole, AC, 415 volts and flush to wall including all cuttings & chases etc in wall and making good to the disturbed surfaces to match the existing complete all as specified and directed.
S&F in repairs sheet metal enclosure distribution board, single pole and neutral, AC, 230 volts, 08 way, with 200 Amps rated copper bus bar and metal double door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified and directed.
S&F in repairs sheet metal enclosure distribution board triple pole and neutral (VTPN), AC, 440 volts, 04 ways with 200 Amps rated copper bus bar and metal door with IP 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified and directed and comprising of the following :- (a) MCCB, 125 Amps, 04 pole, AC, 415 Volts,16 KA - 01 No. (b) MCB, SP, AC, 230 volts of 06 to 32 Amps, "C" curve, 10 KA - 12 Nos.
S&F in repairs of sheet metal enclosure distribution board triple pole and neutral (VTPN), AC, 440 volts, 04 ways with 400 Amps rated copper bus bar and metal door with IP 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified and directed and comprising of the following:- (a) MCCB, 250 Amps, 03 pole, AC, 415 Volts, 25 KA - 01 No. (b) MCB, SP, AC, 230 volts of 63 Amps, "C" curve, 10 KA - 12 Nos.
S&F in repairs MCB, SP, AC, 230 volts of 06 to 32 Amps capacity "C" curve, 10 KA breaking capacity and making connections by using copper lugs complete all as specified and directed.
S&F in repairs MCB, DP, AC, 230 volts of 40 Amps capacity "C" curve, 10 KA breaking capacity and making connections by using copper lugs complete all as specified and directed.
S&F in repairs MCB, DP, AC, 230 volts of 63 Amps capacity "C" curve, 10 KA breaking capacity and making connections by using copper lugs complete all as specified and directed.
Supply and fix in repair of exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm, cutting of hole in wall, making of wooden frome, all arrangements for mounting of fan including making good of disturbed surface etc complete all as specified and directed.
Supply and fix in repair of exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm, cutting of hole in wall, making of wooden frome, all arrangements for mounting of fan including making good of disturbed surface etc complete all as specified and directed.
S&F in repairs MCCB, 63 Amps, 03 pole, AC, 415 Volts of 16 KA breaking capacity complete all as specified and directed.
S&F in repairs MCCB, 100 Amps, 03 pole, AC, 415 Volts of 16 KA breaking capacity complete all as specified and directed.
S&F in repairs MCCB, 125 Amps, 03 pole, AC, 415 Volts of 16 KA breaking capacity complete all as specified and directed.
S&F in repairs MCCB, 160 Amps, 04 pole, AC, 415 Volts of 36 KA breaking capacity complete all as specified and directed.
S&F in repairs MCCB, 200 Amps, 04 pole, AC, 415 Volts of 36 KA breaking capacity complete all as specified and directed.
S&F in repairs MCCB, 250 Amps, 04 pole, AC, 415 Volts of 36 KA breaking capacity complete all as specified and directed.
S&F or passing through pipe, 10 Sqmm, 2 core, 1100 Volts grade, heavy duty, multi-stranded, PVC insulated, aluminium conductor, served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed service cable for service connections from existing LT Panel/Pole to DB/busbar chamber including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified and directed.
S&F in repairs Supply and fixing LED luminaire 4 X 1 feet, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete complete all as specified and directed.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 450MM sweep with, blades, and frame and louvers and taking down old exhaust fan and depositing to MES store yard, all arrangements for mounting of fan including making good of disturbed surface etc complete all as specified and directed.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300MM sweep with, blades, and frame and louvers and taking down old exhaust fan and depositing to MES store yard all arrangements for mounting of fan including making good of disturbed surface etc complete all as specified and directed.
M&L for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried vertically in ground (earth pit not less than 2.25meter deep below ground level) with top edge of the plate not less than 1.5meter below normal ground level steel earth plate connected with GI wire 04mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 75mm center to center both way with 12mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40mmx40mmx3mm frame for pit cover including testing on completion complete all as specified and directed. Note:- On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.
S&F in repairs of switch piano flush type, 06 Amps, single pole one way 230 volts complete all as specified and directed.
S&F in repairs of switch piano flush type, 16 Amps, single pole one way 230 with switch frame, complete all as specified and directed.
S&F in repairs of socket out let 2 in 1, 5 pin, 06 Amp, flush type 230 volts with socket frame, complete all as specified and directed.
S&F in repairs of socket out let 2 in 1, 3 pin, 06 Amp & 3 pin, 16 Amps flush type 230 volts with socket frame, complete all as specified and directed.
S&F in repairs of ding dong bell, AC, 230 volts, single pole complete all as specified and directed.
S&F in repairs of ceiling fan regulator, stepped type of 0 to 04 rotary steps, electronic humfree AC, 230 volts, AC, 230 bolts, 100 watts, complete all as specified and directed.
NEETU TRADERS (INDIA)
m/s lovely cool air
Adhunik Builders
M/s Adhikari construction co.
M/s Prakash Enterprises
Jai Ambay traders
P S TRADERS
Surjit and Sons
Shiv Enterprises
SANJEEV ENTERPRISES
POONAM ENTERPRISES
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .