| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.1 LAccepted-AOC NEAR RAILWAY CROSSING ADAMPUR DOABA JALANDHAR JALANDHAR PUNJAB 144103 | JALANDHAR | PUNJAB | 144103 | L1 | Accepted-AOC Being lowest tender | |
| 2 | L2₹41.8 L+₹2.7 L (6.94%)Rejected-Finance V P O JAGANOO TEH DISTT UDHAMPUR J K 182124 | UDHAMPUR | JAMMU AND KASHMIR | 182124 | L2 | Rejected-Finance Being other than lowest bid | |
| 3 | L3₹42.5 L+₹3.4 L (8.76%)Rejected-Finance 13 P N DOGRA MARKET GOLE MARKET UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L3 | Rejected-Finance Being other than lowest bid | |
| 4 | L4₹43.0 L+₹3.9 L (9.95%)Rejected-Finance 21 JHAMRI 151 JHAMRI JHAMRI ROHTAK HARYANA 124142 UDYAM HR 07 0030314 | JHAJJAR | HARYANA | 124142 | L4 | Rejected-Finance Being other than lowest bid | |
| 5 | L5₹43.2 L+₹4.1 L (10.5%)Rejected-Finance JAIN SADAN MAHAL ROAD SHIVPURI DISTT SHIVPURI MP | SHIVPURI | SHIVPURI | MADHYA PRADESH | L5 | Rejected-Finance Being other than lowest bid |
Tender Value
₹46.8 L
EMD Value
₹93,580
Closing Date
14 Nov 2024, 6:00 pmClosed
GE NORTH UDHAMPUR
GE NORTH UDHAMPUR, C/o 56 APO, PIN-182101
ADDN / ALTN TO BLDGS NOS NP-10, NP-11, NP-12, NP-13 AND NP-14 AT BN ASC AND PROVN OF CHAIN LINK FENCE WITH IRON POLE (200 MTR) FOR THE AREA ADJACENT TO BDY WALL OF 222 COY (SUP) TYPE G UNDER GE (NORTH) UDHAMPUR
2024_MES_665558_2
GE/U(N)-50/2024-25
Open Tender
Civil Works
Item Rate
180 days
AOR OF GE NORTH UDHAMPUR
As per tender
7 documents required · 7 mandatory
₹500
GE North Udhampur
₹93,580
Yes
28 Jan 2025
27 Sept 2024
21 Nov 2024
27 Sept 2024
14 Nov 2024
6 Oct 2024
28 Sept 2024 - 3 Oct 2024
Amount
Demolition of brick work or stone boulder masonry, built in cement mortor including all quoins, arches, pillars etc., complete all as specified and directed.
M&L for brick work with sub class 'B' bricks, old size, straight or curved on plan exc 6 mtr mean radius, build in CM 1.6, complete all as specified and directed.
Taking down cement plaster on brick walls, stone masonry, concrete surfaces etc. including raking out joints, hacking for key, scrubbing down with water etc., complete all as specified and directed.
M&L for 10mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:6, finished the surface even and smooth without using extra cement, complete all as specified and directed.
M&L for 15mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:4 with using water proofing compound, finished the surface even and smooth without using extra cement, complete all as specified and directed.
M&L for 5mm thick rendering CM in 1:3 as on ceiling, finished the surface even and smooth without using extra cement, complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames), area not exceeding 1.50 Sqm each and making good disturbed surface to match with existing surface, complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from frames), area exceeding 1.50 Sqm but not exceeding 4.0 Sqm each and making good disturbed surface to match with existing surface, complete all as specified and directed.
S&F pressed steel frames of size 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. (thickness of sheet shall be 1.25mm) with one shop coat of red oxide primer and making good disturbed surface to match with existing surface, complete all as specified and directed.
S&F 35mm thick factory made 2nd class hard wood plain framed, panelled shutters (two Nos panels) with lock rail and panel of 9mm thick BWP commercial ply or 12mm thick veneered partical board with commercial veneering on both sides. The size of rail and stile as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated, complete all as specified and directed.
S&F 35mm thick 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (with sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc, sizes of members of shutters as specified in SSR Part-I, Section 8, Clause 8.24 (a), complete all as per specified and directed.
M&L for plain cement concrete 1:3:6, type C-0 (using 12.5mm graded crushed stone aggregates) as filling in the pressed steel door frame/ hold fast/ back in chowkats, complete all as specified and directed.
S&F factory made steel windows (box type) with glazing bars, dovetailed or welded including hinges, steel handles, steel peg stays etc. including one shop coat of red oxide zinc chrome primer, fixed at site, complete all as shown on drawingn (as provided by EIC) and directed.
S&F factory made steel windows (box type) without glazing bars, dovetailed or welded including hinges, steel handles, steel peg stays etc. including one shop coat of red oxide zinc chrome primer, fixed at site, complete all as shown on drawingn (as provided by EIC) and directed.
M&L for mild steel framed work such as grills, gratings etc. with ends of bars, shouldered and/ or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walkways, railings, staging for water tanks and similar work, conforming to Fe-290, Gde-E-165, complete all as specified and directed.
S&F aluminium anodised barrel tower bolts, 150mm long of extruded section, complete all as specified and directed.
S&F 300mm long aluminum alloy, anodised, sliding door bolt with hasp staple (bolt type) and fixing clip of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminum alloy, complete all as specified and directed.
S&F alunminium handle, cast type, 150mm long, oval type, complete all as specified and directed.
M&L for preparation of new wooden surfaces or wooden articles, exceeding 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed.
M&L for preparation of new steel or iron surfaces of any description, exceeding 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
M&L for preparation of new decorated surfaces of wall and applying two coats of oil emulsion distemper over and including a coat of 1mm thick wall care putty, complete all as specified and directed.
M&L for preparation of surfaces and applying three coats of white wash on ceiling of any description, complete all as specified and directed.
M&L for preparation of new surfaces of wall and applying two coats of cement base paint over and including a coat of alkali resistant primer, complete all as specified and directed.
S&F galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm, complete all as specified and directed.
M&L for 10mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:4 with using water proofing compound, finished the surface even and smooth without using extra cement, complete all as specified and directed. Note :- WPC shall be measured and paid separately under respective item of BOQ
Supply only integral water proofing compound, complete all as specified and directed.
M&L for preparation the roof surface and priming with bitumenous primer @ 0.30 litre/ Sqm and applying a coat of semi hot blown 85/25 grade bitumen @ 1.2 Kg/ Sqm and thereafter supply and laying polymeric membrane, five layered of weight not less than 3 Kg/ Sqm with centre layer core of 90 micron high molecular density polythylene film and bonded completely to the surface with overlap of 10cm (overlap to be thermo fused by flame) followed by another coat of semi hot blown 85/25 grade bitumen @ 0.70 Kg/Sqm blinded with fine sand in dry condition @ 0.50 Kg/Sqm including dismantling existing membrane sheet including plastering, complete all as specified and directed.
M&L for preparation of surfaces and applying two coats of aluminium paint on roof padding surfaces, complete all as specified and directed.
Excavating in post holes (or similar holes) each, not exceeding 0.50 Cum and getting out in any type of soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm thick, complete all as specified and directed.
M&L for plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) as in foundation, filling in and mass concrete etc., complete all as specified and directed.
M&L for mild steel work as joist, channel, angle, or tee sections, fixed independently without connecting plates etc. (cut to ordinary lengths i.e. within 20mm of the length indicated, conforming to Fe-290, Gde E-165, complete all as specified and directed.
Supply only chain link MS galvanisd fencing, any size or type, complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type, to any type of standards, rails, straining bolts etc. including provision of binding wire, complete all as specified and directed.
Holes drilled upto 12mm dia (and countersunk, if required) depth of holes exc 3mm but not exc 12mm, complete all as specified and directed.
M&L for mild steel screw bolts (machine made) 5 to 10mm neck with hexagonal or square heads at one end and sS&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, not exceeding 5cm long and 5-10mm dia of neck, complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60cm in height, copings and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
S&F galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails, straining bolts, including securing or tying at crossing with and provision of galvanised mild steel wire, staples or steel pins etc., complete all as specified and directed.
M&L for preparation of old decorated surfaces of any description by brooming down and applying one coat of white on ceiling, complete all as specified and directed.
M&L for complete removing of existing treatment and preparation of old surfaces of walls and applying two coats of oil bound distemper over and including 2-3mm thick wall care putty, complete all as specified and directed.
M&L for complete removing of existing treatment and preparation of old surfaces of walls and applying two coats of cement base paint over and including a coat of alkali resistant primer, complete all as specified and directed.
M&L for 6mm thick asbestos cement, corrugated or semi-corrugated sheets as in roofs, walls etc, fixed with coach screws, complete all as specified and directed.
Fixing ony 6mm thick asbestos cement, corrugated or semi-corrugated sheets as in roofs, walls etc, fixed with coach screws, complete all as specified and directed.
M&L for 6mm thick asbestos cement two piece adjustable plain wing ridge, fixed with coach screws, complete all as specified and directed.
Fixing only 6mm thick asbestos cement two piece adjustable plain wing ridge, fixed with coach screws, complete all as specified and directed.
M&L for 6mm thick non asbestos fibre cement building boards, fixed or laid/ inserted to timber/ GI/ aluminium framework with screws, complete all as specified and directed.
Fixing only 6mm thick non asbestos fibre cement building boards, fixed or laid/ inserted to timber/ GI/ aluminium framework with screws, complete all as specified and directed.
S&F anodised aluminium snap grid frame work for false ceiling, complete all as specified and directed.
Fixing only anodised aluminium snap grid frame work for false ceiling, complete all as specified and directed.
Dismantling CGI / ACC / AC (corrugated or semi corrugated etc.) sheet as in roof, walls, covering including ridges, complete all as specified and directed.
Dismantling wall and ceiling boards, fibre, pulp, insulation etc.) or insulation boards/ slabs/ blankets of any thickness including cover fillets, complete all as specified and directed.
S&F brass chromium plated tubular towel rail, 20mm dia, 'D' type, 60cm long between flanges, complete all as specified and directed.
Taking down carefully the existing copper / aluminium point wiring of any size and type by disconnecting from the either terminals complete with switches, sockets, ceiling rose, regulators, bell etc. by unscrewing and removing materials to store for keeping in safe custody for re-use or for taking credit and making good to disturb surface to match with existing surfaces, complete all as specified and directed.
M&L for point wiring with PVC insulated unsheathed, FRLS 1100 volts grade, stranded copper conductor cable, single core 1.5 Sqmm for one light / fan point, controlled by one way switch and wire to be drawn in and including rigid PVC concealed conduit of dia not less than 20mm of 2mm wall thickness, complete with all accessories including GI annealed metal box 1.2mm thick switch board of suitable size, fixed as flush wall with 3mm thick ebonite sheet cover and necessary screws, cap washers etc. or to be fixed on wall respectively as directed and providing earth continuity wire using PVC insulated, un-sheathed single core stranded copper conductor FRLS cable of size 1.5 Sqmm, complete all as specified and directed.
All as per Srl item No. 53.00 here-in-above but for 3/5 pin 5 Amps socket outlet on same board with other switches, complete all as specified and directed.
All as per Srl item No. 53.00 here-in-above but for one 5 Amps socket outlet on independent board, complete all as specified and directed.
All as per Srl item No. 53.00 here-in-above but wire of size 2 x 2.5 Sqmm and providing earth continuity wire using PVC insulated, unsheathed single core stranded copper conductor FRLS cable of size 2.5 Sqmm to controlled the 3 pin 5/15 Amps socket outlet on independent board, complete all as specified and directed.
S&F in replacement switch piano, flush type, one way, single pole, 5 Amps, suitable for 240 Volts, 50 Hz, AC supply, complete all as specified and directed.
S&F in replacement socket, flush type, single pole, 5 Amps, one way, complete all as specified and directed.
S&F in replacement switch socket combination, 2 in 1, 3 pin, 5 and 15 Amp, flush type universal, complete all as specified and directed.
S&F in replacement stepped type electronic fan regulator, flush type on the existing phenolic laminated sheet as required, complete all as specified and directed.
S&F in replacement ceiling rose, 3 terminal, PVC/ polycarbonate isolated body, complete all as specified and directed.
S&F in replacement LED light fitting, PLUTO NEO PANEL, 2'X2' PLR 36 Watt LED 857S, environmental friendly, new generation, aesthetically designed, ultra modern recess mounting luminaire with high brightness SMD LEDs as light source suitable for armstrong / grid / ceiling, complete all as specified and directed.
S&F in replacement slim linear LED lighting fixture 20 Watt LED batten with full base of extruded aluminium section acting as a heat sink with closed back, isolated driver, complete making all connection using 1.5 Sqmm copper conductor multistandard PVC insulated 2 Core flexible cable with flexible PVC pipe from ceiling rose to fittings, complete all as specified and directed.
S&F in replacement E-Lite LED curve lighting fixture 10/12 Watt LED batten with full base of extruded polycarbonate body environmental friendly, energy efficient ready to use pack with isolated driver, complete making all connection using 1.5 Sqmm copper conductor multistandard PVC insulated 2 Core flexible cable with flexible PVC pipe from ceiling rose to fittings, complete all as specified and directed.
S&F in replacement LED 9/10 Watt LED bulk head (6500K) light fitting, surface mounting type, extruded aluminium body with diffuser complete with testing, complete all as specified and directed.
S&F in replacement LED street light fitting, 35 Watt, 230 Volts, AC, outdoor type with high pressure die-cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP- 65/66 protection, complete all as specified and directed.
Taking down fan, sealing cable end, dismantling blades and removing fan and blades to store for refixing on same location, complete all as specified and directed.
M&L for repair of ceiling fan/ exhaust fan 1200/300mm sweep of any make, oiling, greasing, cleaning slot, overhauling & replacement of defective nuts, bolts, washers etc. including painting and rewinding (As required) and other minor items as required at site, complete all as specified and directed.
Hanging / fixing only ceiling/ exhaust fan and connecting up including provision of cable from ceiling rose or connector to fan, complete all as specified and directed.
S&F electric water heater, storage type, steel body with copper inner tank and heating element upto 2 KW of capacity 25 litres, BEE 5 Star rated, complete with all accessories such as safety valve, thermostate, NRV, connection piece etc, complete all as specified and directed.
S&F ceiling fan complete with blades, down rods, electronic regulator and accessories, 230 Volts, 1200mm sweep, minimum air delivery 210 CFM with service value 6.00 BEE, 5 Star rated with brushless direct current motor (BLDC), complete all as specified and directed.
S&F exhaust fan, steel body, AC, single phase, 230 Volts of size 450mm sweep with blades and frame and louver, complete all as specified and directed.
M&L for submain wiring with two run single core 6.0 Sqmm FRLS copper conductor cable PVC insulated, 1100 V grade including 25mm dia in PVC concealed conduit / PVC casing & caping, medium grade, ISI Marked with all accessories such as Tees, elbows, junction boxes etc. as required, fixed on wall alongwith one run of 6.0 Sqmm single core FRLS PVC insulated unsheathed copper conductor cable as continious earth wire and connecting to existing main switch board / distribution board complete including taking down unserviceable submain of any type and size and testing on completion, complete all as specified and directed. Note : Two run of 6.0 Sqmm and one run 6.0 Sqmm cable and one run of PVC conduit or PVC casing and capiing shall be measured as one unit.
M&L for submain wiring with two run single core 4.0 Sqmm FRLS copper conductor cable PVC insulated, 1100 V grade including 25mm dia in PVC concealed conduit / PVC casing & caping, medium grade, ISI Marked with all accessories such as Tees, elbows, junction boxes etc. as required, fixed on wall alongwith one run of 4.0 Sqmm single core FRLS PVC insulated unsheathed copper conductor cable as continious earth wire and connecting to existing main switch board / distribution board complete including taking down unserviceable submain of any type and size and testing on completion, complete all as specified and directed. Note : Two run of 4.0 Sqmm and one run 4.0 Sqmm cable and one run of PVC conduit or PVC casing and capiing shall be measured as one unit.
S&F in replacement single pole and neutral, sheet steel powder coated distribution board for MCBs, fitted with bus bar, neutral link, earth bar and din rail, suitable for use on 240 Volts, 50 Hz supply, double door 8 Way, complete all as specified and directed.
S&F in replacement connection and testing 'C' series, SPN, MCB 40 to 63 Amp, 240 Volts, 50 Hz, 10 KA for lighting and other domesitc loads including necessary copper lugs etc, complete all as specified and directed.
S&F in replacement connection and testing 'C' series, SP, MCB 06 to 32 Amp, 240 Volts, 50 Hz, 10 KA for lighting and other domesitc loads including necessary copper lugs etc, complete all as specified and directed.
S&F in replacement metal clad plug socket, single pole enclosure with two pin earth plug and socket with one single 20 Amp, 240 volts MCB, complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to earth lead by means of bolts nuts and washers of GI and including earthing pit charcoal, common salt, GI 4mm dia lead wire with 20mm GI medium grade watering pipe and 15mm bore light grade protection pipe upto 5 mtr length with wire mesh and funnel, PCC pit in PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregates), angle iron frame and RCC cover and earth work, complete all as shown in electrical plate No.3 of SSR -2009 (Part-1) complete all as specified and directed.
S&F sheet metal TPN DB, 4 way with metal door, 415 Volts grade IP-43 protection grade, fixed flush to wall complete including connections should be provide with necessary reducer lugs, complete all as specified and directed.
S&F DPX3 thermal magnetic MCCB 4 Pole 160 Amps, 415 Volts, 16 KA including making necessary arrangements, complete all as specified and directed.
S&F 415 Volts, 10 KA, 'C' curve MCB TPN 63 to 100 Amp complete with connection and testing, complete all as specified and directed.
Supply and laying in replacement XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 4 Core, laid in trenches/ floor/ pole/ GI pipe complete including cutting/ chasing to any surface and making good to the disturbed surface to match with existing surface, complete all as specified and directed.
Excavating in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation, shaft, wells, cesspits, manholes, laying of pipe etc. and getting out in any type of soil, complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick, complete all as specified and directed.
Removing excavated material (soil) to a distance not exceeding 50 mtr and deposited where directed at a level not exceeding 1.50 mtr from the starting point, complete all as specified and directed.
M&L for dry river sand as cushioning to underground cable provided with a layer of sand of 8cm thick before laying cable and 15cm thick after laying cable, complete all as specified and directed.
Supply and laying brick, Sub class ‘B’, Old size, well burnt as covering to UG cable, complete all as specified and directed.
M&L for 40mm bore GI tubing, light grade with all fitting and fixed to walls/ poles or laid in floors, complete all as specified and directed.
HANS RAJ SHARMA (BID ID -3165456)
VARDHMAN INTERNATIONAL (BID ID -3142481)
KUMAR CONSTRUCTION CO (BID ID -3165471)
anil construction co. (BID ID -3136974)
s l sharma and sons (BID ID -3143766)
JOGINDER SINGH (BID ID -3141944)
takashdeep traders (BID ID -3143826)
M/S JANDIAL ENTERPRISES (BID ID -3136909)
M/S SHREE RAM DUBEY AND SONS (BID ID -3144489)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .