Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.1 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹25.1 L+₹1.0 L (4.19%)Rejected-Finance | L2 | Rejected-Finance L1 being accepted | |
| 3 | L3₹25.5 L+₹1.4 L (5.64%)Rejected-Finance | L3 | Rejected-Finance L1 being accepted | |
| 4 | L4₹25.6 L+₹1.5 L (6.33%)Rejected-Finance | L4 | Rejected-Finance L1 being accepted | |
| 5 | L5₹25.8 L+₹1.7 L (6.90%)Rejected-Finance 10TH MILE RISHI ROAD KALIMPONG DISTRICT DARJEELING PIN 734301 | KALIMPONG | DARJEELING | WEST BENGAL | 734301 | L5 | Rejected-Finance L1 being accepted |
Tender Value
₹22 L
EMD Value
₹44,000
Closing Date
30 Dec 2019, 6:00 pmClosed
GE 867 EWS
GE 867 EWS C/O 99 APO 913867
SPECIAL REPAIRS TO BLDG NO. R-55 AT RONGLI AND SPECIAL REPAIRS TO EXTERNAL WATER SUPPLY AT RHENOCK AND RONGLI UNDER GE 867 EWS
2019_MES_301275_1
CA NO GE / 867 / TOKEN / 25 OF 2019-2020
Open Tender
Civil Works - Others
Item Rate
180 days
Rhenock
Refer tender documents
8 documents required · 8 mandatory
₹500
GE 867 EWS
₹44,000
Yes
13 Jan 2020
26 Nov 2019
31 Dec 2019
26 Nov 2019
30 Dec 2019
11 Dec 2019
26 Nov 2019 - 2 Dec 2019
Amount
S&F 0.63 mm thick galvanised, corrugated mild steel sheeting with two corrugation side lap fixed with "L" or "J" type hook bolts and bitumen washers as in roof covering etc.,with grade of Zinc coating 275 Grms/Sqm including taking down existing steel sheetng of any type complete all as specified and directed by Engineer-in-Charge.
S&F 0.63 mm thick galvanised, plain mild steel sheeting with two corrugation side lap fixed with "L" or "J" type hook bolts and bitumen washers as in ridges, hips,valley gutters, drip and straight flashing etc.,with grade of Zinc coating 275 Grms/Sqm including taking down existing steel sheetng of any type complete all as specified and directed by Engineer-in-Charge.
M&L preparing new Zinc or galvanised surfaces of any description over 10 cm width or girth including CGI sheet in roof etc., and applying one coat of moderent solution to receve painting and applying two coats of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
S&F GI frame work of size 605 x 605 mm, for seamless celing comprising of GI perimeter chanel 0.55mm thick with two unequal flanges of 20 and 30 mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/ intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre including 6mm dia GI hangers (upto1200mm length) adjusting level and providing 4 mm thick asbestos cement plain building boards, fixed to GI frame work with screws as in ceiling and applying 2 coats of white wash including taking down existing ceiling boards of any type complete all as specified and as directed by Engineer-in-charge.
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engineer-in-charge.
M & L for modular fly ash bricks as in brick work straight or curved on plan exceeding 6m mean radious built in cement mortar 1:6 complete all as specified and directed by Engineer-in-charge.
M & L for modular fly ash bricks as in brick work straight or curved on plan exceeding 6m mean radious built in cement mortar 1:6 using serviceable bricks obtained from demolition vide item No. 5 hereinbefore complete all as specified and directed by Engineer-in-charge.
M&L for reinforced cement concrete 1:2:4 mix, type B1 (using 20 mm graded stone aggregate) as in beams, cantilevers, bressummers, lintels exceeding 1.5 m span etc., all as specified and directed by Engineer-in-Charge. Note: Formwork and reinforcement shall be measured and paid seperately.
M&L for reinforced cement concrete 1:2:4 mix, type B1 (using 20 mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams, plinth beams etc., all as specified and directed by Engineer-in-Charge. Note: Formwork and reinforcement shall be measured and paid seperately.
M&L for reinforced cement concrete 1:2:4 mix, type B1 (using 20 mm graded stone aggregate) as in slabs supported on walls, beams and colums in floors, roofs, landings, balconies, canopies, deck slabs and in shelves etc., all as specified and directed by Engineer-in-Charge. Note: Formwork and reinforcement shall be measured and paid seperately.
Use and removal of steel formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc., for rough finished surfaces of concrete flat all as specified and directed by Engineer-in-Charge.
Use and removal of steel formwork to foundations, including rafts, footings, foundation beams, plinth beams etc., for rough finished surfaces of concrete flat all as specified and directed by Engineer-in-Charge.
Use and removal of steel formwork to soffits slabs supported on walls, beams and colums in floors, roofs, landings, balconies, canopies, deck slabs and in shelves etc., for rough finished surfaces of concrete flat all as specified and directed by Engineer-in-Charge.
M&L for Mild steel deformed TMT bars 10mm dia and above as in reinforcement to concrete cut to length bent to shape required including cranking bending and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as directed by Engr-in-charge.
M&L for Mild steel deformed TMT bars 8mm dia as in reinforcement to concrete cut to length bent to shape required including cranking bending and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as directed by Engr-in-charge.
M&Lfor Mild steel deformedTMT bars 5mm dia and over up to and including 10 mm dia as in stirrups, spacers and binders , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with and including mild steel wire (annealed) not less than 0.9mm dia all as specified.
M&L for rendering 15 mm thick on brickwork or concrete surfaces in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed by Engr-in-charge.
M&L for rendering 20 mm thick in two layers of 10mm thick each on brickwork or concrete surfaces in cement mortar 1:4 finished fair and even including waterproofing compound @ 3% by weight of cement as per manufacturer's instructions in the second coat complete all as specified and directed by Engr-in-charge.
M&L for preparation of new plastered surfaces of walls and applying two coats of distemper oil emulsion over one coat of alkali resistant primer complete all as specified and as directed by Engineer-in-Charge. Make: ASIAN/SHALIMAR/BERGER/ JENSON & NICHOLSON/NEROLAC
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement based paint over one coat of primer complete all as specified and directed by Engineer-in-Charge. Make: INDOCEM/ SUPERSNOWCEM/ AQUACEM/ DURACEM
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 sqm each, including cutting holes for taking out hold fasts or dismantling brick work and making good in PCC 1:2:4 type B1 or cement mortar 1:4 (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.) complete all as specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area exceeding 1.5 Sqm and not exceeding 4 sqm each, including cutting holes for taking out hold fasts or dismantling brick work and making good in PCC 1:2:4 type B1 or cement mortar 1:4 (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.) complete all as specified and as directed.
S&F 125x60 mm size pressed steel door frame for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., including PCC 1:3:6 type C0 filling complete all as directed by Engr-in-Charge. Make: - DIWAN STEELS/Ajanta Ispat/AVA Steels or equivalent as approved by GE.
S&F 30mm thick factory made flush shutters, solid core construction with block board core and plywood face panels, commercial type on both sides complete all as specified and directed by Engineer-in-Charge. Make: - Green Ply/Archid Ply or equivalent as approved by GE.
S & F 30 mm thick Second class hard wood Glazed and skeleton shutters for doors, open rebated and prepared to receive glass,gauze etc. without sash bars, edges of framing plain, chamferred or rounded, fitted with cut and mitred beads for securing glass, wire gauge etc. ; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) fitted to chowkats all as specified and directed. Timber:- Sal/Kalasiris/Chaplash/Hollock/Bijasal
S&F steel window with side hung shutters (glazed or wire mesh shutters) fitted with box type hinges with suitable MS handles, peg stays, with glazing bars for receiving glass / MS flat for receiving wire mesh complete all as directed by Engr-in-charge.
S&F steel window with side hung shutters (glazed or wire mesh shutters) fitted with box type hinges with suitable MS handles, peg stays, without glazing bars complete all as directed by Engr-in-charge. Make for Item No. 26&27: M/s Madhu industries / M/s.SEN Harvick / M/s. Shiv Mular / M/s. AGEW. / M/s. Multiwyn Industries Corpn/ M/s Ganesh rolling shutters/AVA steels/Ajanta Ispat or equvalent make as approved by GE.
S & F 3 mm thick Sheet Glass, ordinary quality and glazing with oil putty in steel windows or fitted with wooden beadings in square n. exe 0.5 sqm each pane all as specified and directed. Make: TRIVENI /VALLBH/ATUL/ HINDUSTAN / PILKINGTON / MODIGUARD/SAINTGOBAIN
S & F galvanised mild steel wire cloth, 0.63 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised wire staples or wooden beeds all as specified and directed.
S&F 250mm long aluminium alloy anodised sliding door bolts with hasp & staple (bolt type) and fixing clip of sheet , cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy all as specified and directed.
S&F 150 mm long Aluminium alloy handles cast type anodised all as specified and directed.
S&F 150 mm long Aluminium anodised barrel tower bolts of extruded aluminium section all as specified and directed. Make for Item No. 30 to 32: - CROWN/ CLASSIC/ JYOTHI/ AMIT/ MOWJEE/ARGENT/Bharat/Alans/Hettich/Everlite or any ISI marked make as approved by GE.
M&L Preparing new or previously un treated surfases of wood and wood based surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer all as specified and directed.
M&L for preparation of new or previously untreated surfaces of steel and iron surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer all as specified and directed by Engineer-in-Charge. Make for Item No. 33&34: ASIAN/ SHALIMAR/ BERGER/ JENSON&NICHOLSON/IEL
M&L for 75 mm thick PCC 1:3:6, type C2 (using 40mm graded stone aggregate) in plinth protection, paths etc., laid in alternative bays finished even and smooth without using extra cement including demolition of existing plith protection and removing rubbish off the premises complete all as directed by Engr-in-charge.
M&L for PCC 1:5:10 type E2 (using 40 mm graded crushed stone aggregate) as in surface channels, drains including fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc including all necessary form work including demolition of existing concrete and removing rubbish off the premises complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick square/rectangular area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors etc., jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tiles laid on and including 15mm thick screed bed in cement mortar 1:6 including dismantling existing tiles and removing rubbish off the premises complete all as directed by Engr-in-charge.
M&L for coloured glazed ceramic tiles of size 300x200x7mm thick on vertical surfaces such as skirting/dado, jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tiles laid on and including 10mm thick rendering in cement mortar 1:4 backing coat including dismantling existing tiles and removing rubbish off the premises complete all as directed by Engineer –in-Charge.
S&F Fe 410-W (Gde-E- 250) quality-A Rolled steel sections, as in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., including taking down existing truss complete all as specified and directed by Engineer-in-charge.
Welding in repairs exc 2.5cm but n.exc 5cm in length to structural members, thickness n.exc. 6mm complete all as specified and directed by Engineer-in-charge.
S&F 15mm bore GI water tubing medium grade with all fittings and fixed to wall, floor, ceiling complete including short lengths including taking down existing GI pipe complete all as specified and as directed by Engr-in-charge. Make: TATA/JINDAL/ZENITH
S&F in repairs bib taps 15 mm bore, cast copper alloy chromium plated screwed down high pressure, with crown or capstan head, screwed for iron pipe all as specified and directed by Engr-in-Charge.
S&F in repairs Stop/angle valves 15 mm bore, cast copper alloy chromium plated screwed down high pressure, with crown or capstan head, concealed type with long shank ang cup screwed both ends for iron pipe or for unions all as specified and directed by Engr-in-Charge. Make for Item No. 43&44: SEIKO/RYBO/SPECTRUM/ NMC/L&K/ESSCO (DELUXE)
M&L for salt glazed stone ware drain pipes of 150 mm bore grade 'A' laid in trenches and jointed in cement mortar 1:1 including demolition of old broken pipes including bedding and haunching and removing rubbish outside MD land complete all as directed by Engineer - in -Charge.
M&L for salt glazed stone ware bends or taper bends of 150 mm bore and jointed in cement mortar 1:1 including demolition of old bends and removing rubbish outside MD land complete all as directed by Engineer - in -Charge. Make for Item No. 45&46:- INDO PIPES/ KIRAN POTTERIES/ MANCHERIAL CERAMICS/NOVODAYA CERAMICS or equivalent make as approved by GE
M&L for plain cement concrete bed 1:3:6, type C2 (using 40 mm graded stone aggregate) to drain pipe 150 mm bore including packing under and hunching against the sides of pipes after they laid and tested complete all as directed by Engineer - in -Charge.
M&L for point wiring with 1.5 Sqmm (nominal area) PVC insulated un - sheathed single core stranded copper conductor FRLS cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC casing and capping, medium grade of suitable size with all necessary fittings, fixed on walls/ceilings etc., including 1.5 Sq mm PVC insulated copper conductor FRLS cable for earth continuity conductor and connected to earth dolly and to be terminated in 1.6 mm thick pressed steel terminal boxes concealed type/surface type for mounting fittings like switch, socket, fan regulator etc. with 3 mm thick laminated bakelite sheet cover (Make: Hylem or equivalent ) for housing switches, socket outlet, regulator etc., for one light /fan point controlled by one switch/one bell / buzzer point controlled by one bell push/one 3 / 5 -pin switch socket outlet 5 amps on independent board including taking down existing unserviceable point wiring including switches, sockets, regulators, ceiling roses, terminal boxes and making good disturbed surfaces including testing on completion complete all as specified and directed by Engineer-in-Charge.
All as per item No. 48 above but for One 3/5 pin switch socket outlet 5 amps on same board along with other switches complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring with 2.5 Sqmm (nominal area) PVC insulated un - sheathed single core stranded copper conductor FRLS cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC casing and capping, medium grade of suitable size with all necessary fittings, fixed on walls/ceilings etc., including 2.5 Sqmm PVC insulated copper conductor FRLS cable for earth continuity conductor and connected to earth dolly and to be terminated in 1.6 mm thick pressed steel terminal boxes concealed type/surface type for mounting fittings like switch, socket, fan regulator etc. with 3 mm thick laminated bakelite sheet cover (Make: Hylem or equivalent ) for housing switches, socket outlet, regulator etc., for one 5 / 6 -pin switch socket outlet 15 amps on independent board including taking down existing unserviceable point wiring including switches, sockets, regulators, ceiling roses, terminal boxes and making good disturbed surfaces including testing on completion complete all as specified and directed by Engineer-in-Charge.
M&L for sub main wiring complete with 2 runs of 6 Sqmm PVC insulated heavy duty and unsheathed FRLS cable with multistranded copper conductor and drawing through and including non metalic rigid PVC casing & caping of 20mm size fixed on wall/ceiling and connecting terminal ends including provision of 1 run of 6 Sqmm PVC insulated heavy duty and unsheathed FRLS cable with multistranded copper conductor as earth continuity conductor and connecting to earth dolly including taking down old unserviceable wiring and making good disturbed surfaces complete all as directed by Engr-in-charge. Note: 2 runs of 6 Sqmm and one run of 6 Sqmm and one run of Casing&Caping shall be measured as one unit length. Make for Item No. 48 to 51 Cable: (i) Finolex, (ii) Plaza, (iii) Havells, (iv) Polycab, (v) KEI, (vi) Anchor Casing&Caping: (i) Kinjal, (ii) Alwyn (iii) Harsh, (iv) Finolex (v) Berlia (vi) Plaza
S&F switch piano, flush button, single pole, 5 amps, one way complete all as specified and as directed by Engineer-in-Charge.
S&F switch socket combination 2 – in – one, 3 Pin / 5 Pin, 5 amps flush type complete all as specified and as directed by Engineer-in-Charge.
S&F switch socket combination 2 – in – one 6 Pin , 5 / 15 amps flush type complete all as specified and as directed by Engineer-in-Charge.
S&F lamp holder, insulated body with back plate for batten fittings complete all as specified and as directed by Engineer-in-Charge.
S&F ceiling rose 3 terminal PVC/Polycarnonate, isolated body complete all as specified and as directed by Engineer-in-Charge. Make for Item No. 52 to 56: (i) Anchor (ii) Plaza, (iii) Havells (Crabtree) (iv) ABB (v) Shalabh
S&F metal plug socket single pole and neutral encloser with two pin earth plug with 01 No MCB SP 20 Amp, C series complete all as specified.
S&F sheet metal enclosure DB SPN 8 way 240 V with 200 Amp rated bus bar, powder coated, double door including taking down old unserviceable DB complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing of MCB SPN 5 to 32 Amps, 10 KA breaking capacity, 240 volts, 50 Hz complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing of MCB SP 6 to 32 Amps, 10 KA breaking capacity, 240 volts, 50 Hz complete all as specified and as directed by Engineer-in-Charge. Make for Item No. 57 to 60: HPL/INDOASIAN/ HAVELLS/C&S/ STANDARD
S&F Energy efficient LED Tube light fitting, 1x18/20 watt, with LED tube rod 18/20 Watt with bipin holders, connector block etc., complete with all accessories internally prewired and including connecting up with three core pvc sheathed flexible copper conductor cable of size 1 sqmm including taking down existing fitting and making good disturbed surfaces complete all as specified and as directed by Engineer-in-Charge. Make: Cat part DMLN1LT8-16 of Fitting and LTT8-20 of rod of Crompton or HSN Code:8539 & MAS18W865 T8I-2100lm(PC body),20W865 T8INDI-2100 lm(rod) of Philips or Cat No. SUB118T8 LED(Body),SLETL-DSPC REFORM of Surya.
Supply and fixing integrated LED bulk head luminaries comprises of pressure die cast housing with clear acrylic diffuser & frame and IP 65 protection including 10 W LED bulb and connecting up with existing cable including taking down existing fitting and making good disturbed surfaces complete all as specified and as directed by Engineer-in-Charge. MAKE: Cat part No. LBHE-10-CDL of Crompton or Philips Cat no. WT202WLED 6S NW PSUS2PC or Cat no. SLEBLH 10W of Surya.
S&F retro fit LED Lamp of B-22 holder base with poly corbonate body aluminium heat shrink 05 Watt complete all as specified and as directed by Engineer-in-Charge. Make: Philips /Bajaj/Surya/Crompton/Havells/Mescab/C&S
S&F LED security light suitable for 20 W LED with pressure die cast housing with epoxy coted dark graphite grey colour finish, prismatic polycorbonate cover with individual LED lenses, IP65 including bracket made out of 25 mm dia light grade GI pipe not less than 1.2 mtr long bend to shape duly fixed with MS clamps of 3mm thick, nut, bolts etc complete fixed to wall including electrical connection complete with 3 core 1.5 Sqmm sheathed copper wire ISI marked stranded to LT terminal box to fitting complete including taking down existing fitting all as specified and as directed. Make: Philips /Bajaj/Surya/Crompton/Havells/Mescab/C&S
Supply and fixing Exhaust Fan AC Single Phase, 230/240 Volts, of size 450 mm sweep, Heavy duty, with & including louvers, mounting ring, MS rag bolts, nuts, washers etc and connected from ceiling rose/connector with & including suitable size flexible copper conductor PVC insulated sheathed cord, and testing on completion including taking down existing exhaust fan and removing to store complete all as specified and as directed by the Engineer-in-Charge. Make: Polar/Havells/Khaitan/Usha/Orient/CG
Supply and fixing Water heater storage type (Geyser), electric driven single phase 230 volt, 50 Hz of capacity 50 litres complete in all respect including grouting to wall with suitable size of nut, bolt and connecting with necessary electrical system including taking down existing Gerser and removing to store complete all as specified and directed by Engineer-in-Charge. Make: Bajaj/Venus/Racold/Havells/Crompton
Earthing in repairs complete with galvanized steel earth plate electrode 600 x 600 x 6.3 mm buried directly in ground ( earth pit not less than 2.25 m deep bellow ground level ) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI earth lead wire 4 mm dia. by means of galvanized iron or steel bolts , nuts , check nuts and washers, and connected to equipments as directed , including funnel with GI medium grade watering pipe 20 mm bore , wire mesh , charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode , with concrete pit in PCC 1:3:6 type C-1 , 50 mm thick pre cast RCC 1 : 2 : 4 type B-1 cover slab reinforced with 8 mm dia deformed bar 15 cm C/C and suitable handle of 10 mm dia round bar, 15 mm GI medium grade pipe for earth lead protection including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc. 50 m and necessary testing complete all as shown on electrical plate No. 3 of MES SSR Part-I complete all as specified and as directed by Engineer-in-Charge. NOTE: Rate quoted shall be deemed to include for earth lead and protection pipe upto 7.5m.
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5 in depth for taking out /laying of cable pipe etc., and getting out in soft/loose soil.complete all as specified and directed by Engineer-in-Charge.
Returning, filling in soil, including spreading leveling, watering and wall ramming in laying not exceeding 25 cm thick complete all as specified and directed by Engineer-in-Charge.
Removing excavated soil to a distance n.exe 50m and depositing where directed at alevel n.exe 1.5m above the starting point complete all as directed by Engineer - in -Charge.
Supply and spreading of dry sand in trenches for cable coushioning and punned down complete all as specified and directed by Engineer-in-Charge. Note:- Punned thickness only shall be measured for payment purpose.
M&L for common burnt bricks, sub class 'B', of size 230 x 115 x 75 mm laid in trenches for cable protection complete all as specified and directed by Engineer-in-charge.
Supply and laying in trenches, fixed to wall or drawn through pipe etc., XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sqmm 2 core and connecting with necessary lugs including taking out exising unserviceable cable complete all as specified and directed by Engineer-in-Charge. Note:- Excavation, earth work, brick protection, protection pipe and sand coushioning shall be measured and paid separately. Make of cable shall be CCI / Gloster / ICC / Unistar / NICCO / Asian (RPG) / Havells / Polycab/PRG/Universal/Plaza/Crystal cables/Terracom/ Rallison/Mescab/Jeypore/KEI
Material and labour for 25 mm dia bore GI tubing Light grade, laid under roads/ floor, or fixed to wall or along the pole with suitable size M.S.flat iron clamps, nuts, bolts and washers for cable protection or as in stand for post top lantern including taking down/out existing pipe complete all as specified and directed by Egineer-in-Charge. Make: TATA/ZENETH/JINDAL or equivalent as approved by GE.
S&F 50mm dia bore medium grade galvanised iron tubing with all fittings and fixtures complete laid in trenches or on ground including taking up or down existing water tubing and connections complete all as specified and as directed by Engineer-in-Charge. NOTE: Excavation and earth work shall be measured and paid separately.
All as per item No. 75 above but 40 mm dia bore.
All as per item No. 75 above but 25 mm dia bore.
All as per item No. 75 above but 20 mm dia bore. Make for Item No. 75 to 78: TATA/ ZENITH / JINDAL
M&L for taking up or down existing 50 mm dia bore water tubing and connections and cleaning & re-laying with and including new ISI marked pipe fittings, in new or old position in trenches, floors, etc., complete all as specified and as directed by Engineer-in-Charge. NOTE: Excavation and earth work shall be measured and paid separately.
All as per item No. 79 above but 40 mm dia bore.
All as per item No. 79 above but 25 mm dia bore.
All as per item No. 79 above but 20 mm dia bore.
S&F gun-metal, globe or gate valves of with iron wheel head, screwed both ends for iron pipe of 50 mm dia bore and fixed including taking down existing unserviceable valve complete all as specified and directed by the Engineer-in-Charge.
All as per item No. 83 above but 40 mm dia bore.
All as per item No. 83 above but 25 mm dia bore.
All as per item No. 83 above but 20 mm dia bore. Make for Item No. 83 to 86:LEADER/NETA/ANCHOR/NMC/ DURGA/ZOLOTO or equivalent ISI marked make as approved by GE.
Supply and fixing Rotational moulded polyethylene water storage tank cylindrical vertical double layered, 2000 ltrs capacity with closed top hoisted and fixed in position all as specified in SSR Part I including taking down existing water tank complete all as specified and directed by Engineer-in-Charge.
All as per item No. 87 above but 1000 ltrs capacity.
All as per item No. 87 above but 500 ltrs capacity. Make for Item No. 87 to 89: SINTEX/ INFRA/ GP/ ROTEX/ ORIPLAST/ ASHISH/ POLYCON or equivalent ISI marked make as approved by GE.
S&F Symet ball valve 25 mm with high pressure of PTMT with epoxy coated aluminum rod & high density plastic ball screwed for iron pipe and fixed min weight for 25 mm 455 gms, including taking down existing unserviceable ball valve complete all as specified and directed by Engineer-in-Charge.
S&F Symet ball valve 20 mm with high pressure of PTMT with epoxy coated aluminum rod & high density plastic ball screwed for iron pipe and fixed min weight for 20 mm 210 gms, including taking down existing unserviceable ball valve complete all as specified and directed by Engineer-in-Charge. Make for Item No. 90&91:- PRAYAG/POLYTUFF or equivalent as approved by GE.
M&L for Plain cement concrete 1:3:6 mix type C2 (using 40 mm graded stone aggregate) in foundations, filling and mass-concrete etc., all as specified and directed by Engineer-in-Charge.
M & L Plain cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) as in coping including necessary formwork, weathering, slightly rounded or chamfered andgles, finishing of exposed surfaces of concrete to even and smooth without using extra cement all as specified and directed by Engr-in-charge.
M&L for Plain cement concrete 1:3:6 mix type C2 (using 40 mm graded stone aggregate) in walls or retaining walls, pillars etc., including necessary form work all as specified and directed by Engineer-in-Charge.
Sub Total of Schedule 'A'
Schedule of Credit (Minus) Rs. 84,440.00 B/F from Ser page No. 34 NOTE: Bidder shall insert credit amount as rate Rs. 84,440.00 in Green field under Col-M. If bidder does not insert the amount the same will be deducted from total amount of Schedule 'A' and accordingly total amount of tender will be considered in deciding the lowest tender.
Sub Total of Schedule of Credit
DEEP CHANDRA JOSHI
SANJAY SAW MILL
GARGO TRADERS
MS MAYA PRAKASH GOEL AND SONS
SANJAY MITTAL
RAJU TAMANG
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .