Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.0 LAccepted-AOC | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹23.5 L+₹3.5 L (17.7%)Rejected-Finance 6 GOODS SHED ROAD TITAGARH KOLKATA 700119 | TITAGARH | NORTH 24 PARGANAS | WEST BENGAL | 700119 | L2 | Rejected-Finance 2nd lowest bidder | |
| 3 | L3₹26.0 L+₹6.0 L (30.2%)Rejected-Finance 19 LAKE TEMPLE ROAD KOLKATA 700029 | KOLKATA | WEST BENGAL | 700029 | L3 | Rejected-Finance 3rd lowest bidder | |
| 4 | L4₹32.7 L+₹12.7 L (63.6%)Rejected-Finance 86 TOLLYGUNGE CIRCULAR ROAD KOLKATA WEST BENGAL 700053 | KOLKATA | KOLKATA | WEST BENGAL | 700053 | L4 | Rejected-Finance 4th lowest bidder |
Tender Value
Refer Docs
EMD Value
₹47,800
Closing Date
2 Nov 2022, 12:00 pmClosed
Exe.Engr._I, Kol. South Health El. Divn., PWDte
75 D H Road Kidderpore Kol_23
E.I. and Air-conditioning work for setting up 18 Bedded Hyper Acute Stroke unit at 5th Floor and 5 Bedded Hyper Acute Stroke unit Extension at 4th Fl. at Ramrikdas Haralalka Hospital, IPGMER_S.S.K.M. Hospital_Annex_4 Kolkata
2022_WBPWD_410981_1
WBPWD/KSHED/Q17/22-23(2nd Call)
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
Kolkata
Please refer Tender documents.
2 documents required · 2 mandatory
₹47,800
O/o Exe.Engr., Kol. South Health El. Divn., PWDte
4 May 2023
27 Sept 2022
4 Nov 2022
27 Sept 2022
2 Nov 2022
11 Oct 2022
11 Oct 2022
Amount
E.I. WORK :- S & Laying 1.1KV gr. 4 Core 95 mm² XLPE Ar. / Al. Cable with 2 nos. 10 SWG G.I. Wire incl. making connections as reqd. and marking as per direction of E.I.C. as follows :- (From Sub Panel to VTPN DB for power utilities). (Make :- RR Kabel / Havells / Gloster).
On wall surface by proper clamping through cable duct as to G.S.
On prelaid cable tray
S & F compression type brass cable gland including end finishing of the following different size cables
4 Core 95 mm² XLPE Ar. / Al. Cable
S & F 4 X 25 Sqmm HRFR grade PVC insulated multistranded flexible copper wire.
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. (Make - Legrand)
Up to 160A, 8 way Enclosure
Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB horizontal / vertical enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment
Supplying and fixing MCCB SS enclosure with IP- 20/30 protection, pwder coated provision for housing Four pole (4P) MCCB, on top of existing cubical panel by providing necessary supports of flat iron frame incl. painting, connection & provision for earthing attachment & making holes on existing panel top sheet for 100 A MCCB.
S & F Cable end box suitable for 4-way MCCB Enclosure.
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. Legrand make 4way.
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection. (Make :- Legrand)
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. (Make :- Legrand)
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. (Make :- Legrand)
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire (Finolex/ Havells/ Polycab/Gloster) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment fixed on wall incl. mending good damages to original finish
Avg. Run 8 Mtrs.
Distribution wiring in 1.1 KV single core stranded 'FRLS' PVC insulated & unsheathed copper wire (Make:- Finolex / Havells / RR Kabel/Gloster) in 20 / 25/32 mm size MMS PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required.
4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC in 32mm conduit.
4 x 56/0.3 (4 sqmm) + 2 x 36/0.3 (2.5 sqmm) ECC (For VTPN to AC).
2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC (From TPN PDB to SPN DB).
2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC (For multiple socket Board).
3 x 1.5 mm² copper wire. (For AC control switch & Ceiling rose to fittings ).
Distribution wiring in 1.1 KV single core stranded 'FRLS' PVC insulated & unsheathed copper wire (Make:- Finolex / Havells / RR Kabel/Gloster) in 20/25 mm size HMS PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required. (for outdoor) .
4 x 56/0.3 (4 sqmm) + 2 x 36/0.3 (2.5 sqmm) ECC. (For VTPN to AC).
3 x 1.5 mm² copper wire. (For AC control switch).
Finishing the end of following sizes copper wire end / PVC cable/Al. with dowells solderless socket by crimping method as pre GS as follows :-
10 mm² copper wire.
6 mm² copper wire.
4 mm² copper wire.
2.5 mm² copper wire.
Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board.
Supplying & Fixing 2 Module GI / PVC Modular Switch Board of the followingsizes complete with top cover plate flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works.
Supply & Fixing 240 V 6 A Modular type switch (Brand approved by EIC) on existing GI Modular type switch board having top cover plate and making necessary connections as required.
Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch (Brand approved by EIC), 16A Modular switch type MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 2 nos. 6 A, 3 pin Modular type plug socket with 2 nos. 6A Modular type switch (Brand approved by EIC), without plug top on 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy.connections with PVC Cu wire and earth continuity wire etc.
Supplying & Fixing of PVC water proof type Loop box (Make-Sintex GSJB2520 /Hensel) of size [250X200X100]mm having hinged PVC top cover & 4 mm thick with rubber gasket lining,railway type mechanical locking arrangement, with DIN rail. on wall as per direction of EIC.
S.I.T.C. of Crono time switch [Make - L&T Cat. No. 67DDT0]
S & F of 3 pole contactors ABB make AX32-30-10 with 240 V operating coil.
Fixing only full 2ft x2ft light fitting on false ceiling incl. necessary connection and hanging arrangement from the true ceiling.
Fixing only Recessed type circular (Dia up to 8 inch) LED down light after cutting the false ceiling incl. necessary connection as required.
Supply & Delivery of LED Smart Glow High eficiency light fittings ( Make-Philips, Cat. No.RC383B LED36S-6500 PSU OD WH PIR / Crompton/ wipro having similar specification ).
Supply & Delivery of LED Full Glow High eficiency light fittings ( Make-Philips, Cat. No.RC380B LED36S-6500 G5 L60W60 PSU OD SG / Crompton/ wipro having similar specification ).
Supply & Delivery of 2000Lm output recess mounted LED down light ( Make-Philips, DN296B LED20S-6500 PSU WH / Crompton/ wipro having similar specification )
Supply & Delivery of 1200Lm output recess mounted LED down light ( Make-Philips, DN296B LED12S-6500 PSU WH / Crompton/ wipro having similar specification )
AIR-CONDITIONING WORK:- S&D of minimum 10.55KW nominal cooling capacity ceiling suspended [Concealed] medium static, Split Air Conditioner with R410A / R407C / R-32 Refrigerant having single Scroll Compressor / Swing compressor for inverter machine, suitable for operation on 415V,+_ 5% , 50Hz, 3Ph AC Supply. with precharged refrigerant, Wired/ Wireless remote, filter & all other accessories (Make : DAIKIN model FDMF1125BRV16/ RZMF125BRY16 / Mitsubishi heavy industries model FDUM100CSV-S6/FDC100CSV-S6 / O General model ARG36F/AOG36F).
Installation testing & commissioning of above AC machines at 4th floor by fixing the indoor with two number 1mt long unequal MS "T" section bar of sizes 70mmX35mmX 6mm with minimum 6nos 10mm X75mm anchor fastner bolt drilled into the ceiling. The indoor unit suspended from this "T" section support with 4 nos 40mm X 6mm MS flat & 10mm full threaded suspender bolt with double nut & spring washer. Out door unit will be fixed on existing MS Structure on out side of 4 th floor by four number suitable nut bolt fixed on base with necessary modification by welding flat iron pieces. And mending good the damages of walls by CC & sand cement plaster.
S&D of minimum 13KW nominal cooling capacity ceiling suspended [ concealed] Split Air Conditioner with R410A / R407C / R-32 Refrigerant, with single Scroll Compressor / Swing compressor in inverter machine, suitable for operation on 415V,+_ 5% , 50Hz, 3Ph AC Supply. with precharged refrigerant, Wired/ Wireless remote & all other accessories (Make : DAIKIN model FDMF140BRV16/ RZMF140BRY16 / Mitsubishi heavy industries model FDUM125CSV-S6/FDC125CSV-S6 / O General model ARG60F/AOG60F).
Installation testing & commissioning of above AC machines at 5th floor by fixing the indoor with two number 1.2mt long unequal MS "T" section bar of sizes 70mmX35mmX 6mm with minimum 6nos 10mm X75mm anchor fastner bolt drilled into the ceiling. The indoor unit suspended from this "T" section support with 4 nos 40mm X 6mm MS flat & 10mm full threaded suspender bolt with double nut & spring washer. Out door unit will be fixed on roof by MS chair made by 50mmX50mmX6mm equal angel & minmum hight of 450mm from floor level & grouting the same, painting as per direction of EIC & carrying the outdoor to the roof of building. And mending good the damages of walls by CC & sand cement plaster.
Dismantling the existing out door of 1.5TR/ 2TR split type room air Conditioner installed at 2nd, 3rd, 4th & 5th floor & reinstall the out door at the newly constructed MS structure at 4th floor. Incl ecessary scaffolding & mending good the damages.
Supply & Laying of Refrigerant Copper pipe of following diameter for connecting of Indoor to Outdoor unit, along with drip resistant nitrile rubber insulation with double insulating wrapping tape to avoid dripping of condensate water:-
Discharge Line 6mm dia, min. thickness 0.6m with 9mm thick nitrile insulation. (Make : Rajco / Royku).
Discharge Line 9.5mm dia, min. thickness 0.9m with 9mm thick nitrile insulation. (Make : Rajco / Royku).
Suction Line 15.9mm dia, min. thickness 1.02mm with 9mm thick nitrile insulation. (Make : Rajco / Royku).
Supply & Laying of PVC insulated unarmoured 1.1 KV grade 6 Core 2.5sq mm copper cable from indoor to outdoor unit with necessary fixing arrangement. (Finolex / Polycab / Havells)
Supply & Laying of PVC insulated unarmoured 1.1 KV grade 4 Core 2.5sq mm copper cable from indoor to outdoor unit with necessary fixing arrangement. (Finolex / Polycab / Havells)
Supply & rapping the copper pipe with insulation & electric cable by 26SWG Aluminimum sheet to make it weather & vermin proff.
6mm dia with 9mm thick nitrile insulation, 15.9mm dia with 9mm thick nitrile insulation & 4core 2.5Sqmm Copper cable.
9.5mm dia with 9mm thick nitrile insulation, 15.9mm dia with 9mm thick nitrile insulation & 8core 2.5Sqmm Copper cable.
Supply & laying drain Water piping work with 25 mm dia Schedule 40 PVC/ UPVC hard pipes (Finolex / Ashirbad / Supreme) incl. fitting , accessories bends, elbows, tees, flanges, tapings, etc. insulated with 9mm. thick nitrile rubber tube insulation.
Supply & Fixing of Fresh air package with cowl, bird net & Volume control damper arragements.Make - Systemair / Air Enterprise / Premire / Caryaire / Airmaster
S&F flexible canvas connection for indoor to duct/ air terminal for
10.55KW indoor
13KW indoor
SITC of Powder Coated Al. Grill without VCD suitable size (Make:Systemair / Primier)
S& charging R410refrigerant
Supply & Fixing underdeck insulation by 50 mm thick 16 Kg/cumtr density of EPS insulation for underdeck insulation. Make- Beardsell/ Astha.
Terms and condition
The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them.
Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/submission of bill.
If any refurbished material is supplied and installed, penal action will be taken as per existing rules
Defect Liability period 1 (One) Year
ARATI ENTERPRISE
Shinryo Suvidha Engineers India Pvt Ltd
Lyric International
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .