| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.0 LAdmitted-Finance 53 13 A OUTER CIRCULAR ROAD KILPAUK GARDEN COLONY CHENNAI 600 010 | CHENNAI | CHENNAI | TAMIL NADU | 600010 | L1 | Admitted-Finance | |
| 2 | L2₹25.1 L+₹3.2 L (14.4%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹26.5 L+₹4.6 L (20.7%)Admitted-Finance OLD NO 338 NEW NO 17 19TH NEDUMANEHLIAN STREET G K M COLONY CHENNAI 600 082 | CHENNAI | CHENNAI | TAMIL NADU | 600082 | L3 | Admitted-Finance | |
| 4 | L4₹27.5 L+₹5.6 L (25.4%)Admitted-Finance NO 235 PSK ILLAM SANKARAN NAGAR CHINNAMMAN KOIL STREET AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | L4 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/s.Sai Agency L1 | PSK Enterprises L4 | Akshaytraders L2 | GK ENTERPRISES L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exc 1.5m in width and 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed. | 588.22 | cum | 260 ₹1,52,937.2 | 260 ₹1,52,937.2 | 270 ₹1,58,819.4 | 250 ₹1,47,055 Lowest |
| 2.00 | Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25cm complete all as specified and as directed. | 365.42 | cum | 206 ₹75,276.52 | 98 ₹35,811.16 | 50 ₹18,271 Lowest | 90 ₹32,887.8 |
| 3.00 | Removing excavated material / soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. | 50.04 | cum | 350 ₹17,514 | 98 ₹4,903.92 | 50 ₹2,502 Lowest | 70 ₹3,502.8 |
| 4.00 | Cushioning of cable laid in trenches using excavated soil, fine sieved and spreading levelling for cable trenches complete all as specified and directed.
(Note: Punned thickness only shall be measured and paid.) | 172.34 | cum | 170 ₹29,297.8 | 98 ₹16,889.32 | 80 ₹13,787.2 Lowest | 200 ₹34,468 |
| 5.00 | Supply and laying well burnt bricks sub class 'B' in trenches for cable protection of U/G cable complete all as specified and directed. | 12,000 | Each | 5.3 ₹63,600 Lowest | 5.3 ₹63,600 Lowest | 7 ₹84,000 | 9 ₹1,08,000 |
| 6.00 | DWC (Double wall corrugated) pipe 50 x 38 mm conforming to IS: 14930/ IS 16205 for protection of electric cables including necessary snap-fit coupler required for fixing. | 600 | RM | 44 ₹26,400 Lowest | 170 ₹1,02,000 | 50 ₹30,000 | 130 ₹78,000 |
| 7.00 | Taking out the existing PVC/XLPE, 1100 volts grade, LT UG electric cable of size 25 sqmm x 3.5 core from trenches/ walls (or) passing through pipes/in floor removing the unserviceable fault cable and carefully stacking the serviceable cable for reusing all as specified and directed by the Engr-in- charge
Note:- Excavation and Earth work shall be measured and paid separately under appropriate items | 432 | RM | 26 ₹11,232 | 17 ₹7,344 Lowest | 35 ₹15,120 | 30 ₹12,960 |
| 8.00 | All as per item No.7 above but 35sqmm 3.5 core | 405 | RM | 26 ₹10,530 Lowest | 26 ₹10,530 Lowest | 35 ₹14,175 | 30 ₹12,150 |
| 9.00 | All as per item No.7 above but 50 sqmm 3.5 core | 473 | RM | 35 ₹16,555 | 26 ₹12,298 Lowest | 35 ₹16,555 | 30 ₹14,190 |
| 10.00 | All as per item No.7 above but 70sqmm 3.5 core | 459 | RM | 35 ₹16,065 | 26 ₹11,934 Lowest | 35 ₹16,065 | 40 ₹18,360 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
19 Sept 2026, 6:00 pmClosed
GE Chennai
GARRISON ENGINEER FORT SAINT GEORGE CHENNAI - 600009
REPAIRS/MAINT OF LT EXTERNAL ELECTRIFICATION DISTRIBUTION NETWORK AND CONNECTED ACCESSORIES AT A, B and D AREA UNDER GE CHENNAI
2026_MES_785974_1
8962/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE Chennai
As per NIT
7 documents required · 7 mandatory
₹500
GE Chennai
₹60,000
Yes
23 Sept 2026
22 Aug 2026
21 Sept 2026
22 Aug 2026
19 Sept 2026
5 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation in trenches not exc 1.5m in width and 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed. | 588.22 | cum | - | - |
| 2 | Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25cm complete all as specified and as directed. | 365.42 | cum | - | - |
| 3 | Removing excavated material / soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. | 50.04 | cum | - | - |
| 4 | Cushioning of cable laid in trenches using excavated soil, fine sieved and spreading levelling for cable trenches complete all as specified and directed.
(Note: Punned thickness only shall be measured and paid.) | 172.34 | cum | - | - |
| 5 | Supply and laying well burnt bricks sub class 'B' in trenches for cable protection of U/G cable complete all as specified and directed. | 12,000 | Each | - | - |
| 6 | DWC (Double wall corrugated) pipe 50 x 38 mm conforming to IS: 14930/ IS 16205 for protection of electric cables including necessary snap-fit coupler required for fixing. | 600 | RM | - | - |
| 7 | Taking out the existing PVC/XLPE, 1100 volts grade, LT UG electric cable of size 25 sqmm x 3.5 core from trenches/ walls (or) passing through pipes/in floor removing the unserviceable fault cable and carefully stacking the serviceable cable for reusing all as specified and directed by the Engr-in- charge
Note:- Excavation and Earth work shall be measured and paid separately under appropriate items | 432 | RM | - | - |
| 8 | All as per item No.7 above but 35sqmm 3.5 core | 405 | RM | - | - |
| 9 | All as per item No.7 above but 50 sqmm 3.5 core | 473 | RM | - | - |
| 10 | All as per item No.7 above but 70sqmm 3.5 core | 459 | RM | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.35 MB
Tender8962.pdf
Tender Documents • 0.71 MB
BOQ_880755.xls
BOQ • 0.29 MB
8962_OTHER_Corrigendum.pdf
PDF • 0.48 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .