Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.6 LAccepted-AOC | L1 | Accepted-AOC ACCEPT | |
| 2 | L2₹42.1 L+₹1.5 L (3.66%)Rejected-Finance | L2 | Rejected-Finance OK |
Tender Value
₹50 L
EMD Value
₹50,000
Closing Date
5 Feb 2024, 3:00 pmClosed
THE COMMISSIONER, ERODE CITY MUNICIPAL CORPORATION
246,MEENASHI SUNDHARANAR SLAI,ERODE-638001
Construction of community hall at kakkan Nagar (VGB Nagar) in ward No. 25
2024_MAWS_415032_1
E1-1302-2023-2 Construction of community hall at kakkan Nagar (VGB Nagar) in ward No. 25
Open Tender
Civil Works
Works
180 days
ERODE CITY MUNICIPAL CORPORATION
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹50,000
15 Mar 2024
30 Jan 2024
5 Feb 2024
30 Jan 2024
5 Feb 2024
30 Jan 2024
Amount
Earth work excavating and depositing on bank within initial lead of 10 meters and lift of 2 meters in Hard / Ordinary gravelly soil as per S.S. 20B
Cement concrete 1:4:8 mix (One cement four sand and eight metal) using 40mm ISS hard broken granite stone jelly for foundation and flooring including dewatering wherever necessary and laid in layers of not exceeding 15cm thick to required thickness including cost and conveyance of all materials to work site and labour charges etc., complete complying with standard specification (TNDSS No. 23, 28, VI(3.51) 4.2, 4.3)
Supplying and filling of good river sand laid in layers of not exceeding 15cm thick including cost and conveyance of all materials to site and watering , consolidtion etc., complete as per standard specification
Centering for soffits of RCC slabs plane surface including strutting upto 3.00m height using mild steel of size 90cmx60cmx10 gauge fitted with MS angle of size 25mmx25mmx3mm laid over silver oak (CW) joists of size 10cmx6cm spaced at 90cm c/c and support by casurina props of 10 to 13cm dia and spaced at 75cm c/c etc., complete.
for column
Plane surface and beam
BRICK WORK in cement mortar 1:5 (One cement and Five M sand) using Fly Ash bricks of size 230mmx110mmx70mm-virtually the bricks shall be sound compact and uniform in shape free from visible cracks warppage flaws and organic matter.the bricks shall be solid with frog on one of its bearing side. class designation not less than 35 kg/sq.cm an average compressive strength in cement mortar 1:6 one cement and six sand -including neat finishing ,curing etc.,complete complying with standard specification.
Plastering with cement mortar 1:5 (One cement and five sand) mix 12mm thick including cost of all materials and labour including curing charges complete as per standard specification
Flooring finishing with vertified tiles of size 30cmx30cmx6mm laid in cement mortar 1:3 mix to 20mm thick and painting with white cement using 0.40kg/1m2 including finishing, jointing and painting flush with tiles surface etc., complete.
Paving the floor with design Antiskirt ceramic tiles (colour and shade as directed) of size 305 mm x 305mm x 6 mm in all floors over a base layer of cement mortar 1:3 (one cement and three sand ) 20mm thick laid in-situ and pointed with same coloured cement
Reinforced cement concrete 1:1.5:3 mix (One cement one point five sand and three aggregate) for all reinforced cement concrete works using 20mm ISS gauge hard broken granite stone metal including cost and conveyance of all materials at site including all labour charges for concrete mixing laying concrete finishing the surface neatly watering curing property laid excluding the cost of steel reinforcement and centering etc., complete complying with standard specification (TNDSS No.30)
Supplying, fabrication and placing in position of mild steel or ribbed tar steel for reinforced cement works including cost of steel binding wire all labour charges for cutting fabrication and placing of rods and other incidental charges etc., complete as per standard specification
Plastering with cement mortar 1:3 mix (One cement and three sand) 10mm thick concrete surface cleaning, curing etc., complete including cost of materials to site etc., complete as per standard specification.
Plastering with cement mortar (1:3) 20mm thick in all floors including cost and conveyance of all materials to site and labour charges etc, complete complying with standard specifications
Supplying and fixing of MS sheet steel window consists of frame and shutters the frame will be of 40mmx40mmx6mm MS angle alround the indermediate of frame will be of T section using 40mmx6mm and 25mmx6mm M.S. flats the shutters will be of 18 gauge of MS sheet with L angle of size 25mmx25mmx4mm alround in each leaf and cross bracing of MS flats 25mmx6mm including cost of tower bolt of 10mm dia MS bars with necessary hook and arrangement including cost of materials clamps for fixing of window in the wall cutting bending welding and fixing charges etc., complete as per standard specification.
Supplying and fixing of steel door double leaf made out of 18 gauges M.S. sheet outer frame 35x35x5mm angle inner frame, 25x25x5mm angle cross stiffener MS flat 20x5mm with aldrop 1 No. tower bolts 4 Nos, two handle and six hold fast complete welded and revitted and painted one coat of red oxide paint including cost of all materials and labour charges etc., complete as per standard specification.
Weathering course concrete with broken brick jelly 20mm size in pure slacked lime in proportion 32:12:5 (without sand) over RCC roof slab laid to the required slope and thickness for easy flow of rain water beaten with wooden beaters complete as per standard specification
Wiring with 2x1.5 sq.mm (22/0.3) PVC insulated unseathed SC Cu. Conductor of 1100V grade in suitablev PVC rigid pipe concealed in wall and ceiling with PVC accessoires with TW switch box and 5A F.T. switch in flushwith wall with 3mm thick hylum sheet cover for making good of the concealed portion with suitable colour for PVC concealed light point.
Wiring with 2x1.5 sq.mm (22/0.3) PVC insulated unseathed SC Cu. Conductor of 1100V grade in suitablev PVC rigid pipe concealed in wall and ceiling with PVC accessoires with TW switch box and 5A F.T. switch in flushwith wall with 3mm thick hylum sheet cover for making good of the concealed portion with suitable colour for PVC concealed fan point. ( For electronic regulator)
Wiring with 2x1.5 sq.mm (22/0.3) PVC insulated unseathed SC Cu. Conductor of 1100V grade in suitablev PVC rigid pipe concealed in wall and ceiling with PVC accessoires, in flush with wall, with150mm x 100 mm x 113mm TW switch box with 3mm thick hylum sheet cover for 5A 3 Pin non inter locking CS Plug with cotinuous earth wire connection of 14SWG TC wire and making good of the concealed portion with suitable colour for PVC plug point.
Wiring with 2x 4 sq.mm (56/0.3) PVC insulated unseathed SC Cu. Conductor of 1100V grade in suitablev PVC rigid pipe concealed in wall and ceiling with PVC accessoires, in flush with wall, with150mm x 100 mm x 113mm TW switch box with 3mm thick hylum sheet for 15A 3 Pin non inter locking CS Plug with cotinuous earth wire connection of 14SWG TC wire and making good of the concealed portion with suitable colour for concealed power plug point.
Supplying and fixing of 4' 40 w flu. Fitting complete with copper choke and condensor with TW round blocks on wall or ceiling with flu. Tube with PVC unseathed copper leads fromterminals to the fitting.
Supplying and fixing of 1200mm ( 48 ") AC ceiling fan complete with stepped electronic 300W regulator with 450mm down rod on the existing clamp.
Supply and run of 4 x 6 sq.mm. (84 / 0.3) PVC insulated single core unsheathed copper conductor of 1100V on 7 / 20 GI bearer wire for service connection mains(SD68)
Supply and run of 4 x 6 sqmm ( 84/0.3) PVC insulated SC unseathed cu. Conductor of 1100V grade in 32mm dia GI pipe (class 'B') suitably bent at both ends with necessary angle iron up right and end supports for mains.
Supply and fixing 3 phase 32 A aerial fuse units for 3 Nos. 32A fuse units (500V) on suitable MS sheet covered with 6mm hylum sheet. On suitable angle iron work On the tapping pole with necessary clamps.
Supplying and fixing of TNEB meter board suitable for 32A three phase service connection with 3 Nos of 32A fuse unit (500V) 32A neutral link and earth link(1"x1/8"copper flate) on TW plank of size 600mm x 450mm x 19mm with supporting TW reepers of 1" thick an either side with painting with suitable bolt and nuts for fixing TW plank on wall with earth connection and inter connection with 7/20 PVC insulated copper wire from EB meter to fuse unit.
Refilling the trenches with excavated soil earth (other than sand) complying with the standard specification etc complete., as directed by Engineer in charge
Painting two coats with approved quality of weather seal paint over the plastered surface including cost and conveyance of all materials to site and all labour charges etc., complete as per standard specification.
Painting two coats with best approved quality of enamal paint over one coat of priming for new iron work including all labour charges etc., complete as per standard specification.
Supply and fixing in position of 110mm dia PVC rainwater downfall pipe with necessary PVC shoe, PVC bend, TW plug, Ci clamps including all labour charges cost and conveyance of all materials to site etc., complete as per standard specification.
Supplying, fabricating, erecting structural steel work for roofing welded or bolted type using MS channels, angles, plates and round bars etc. conforming to IS specification including primer coating and enamal painting as per Design given by the departmental officers etc, complete as per standard specification
Roofing with Galvanised Coruugated Iron Sheet of 0.8mm thickness - 10 m2
KING CONSTRUCTION
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_493802.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .