Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.6 LAccepted-AOC NO 439 AHIV ADAN 11ND FLOOR 2RD STAGE INDIRA NAGAR BANGALORE 560 075 | BENGALURU URBAN | KARNATAKA | 560075 | L1 | Accepted-AOC deduct credit | |
| 2 | L2₹52.8 L+₹3.9 L (8.07%)Rejected-Finance BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | L2 | Rejected-Finance rejected being L2 | |
| 3 | L3₹53.4 L+₹4.6 L (9.35%)Rejected-Finance | L3 | Rejected-Finance rejected being L3 | |
| 4 | L4₹53.9 L+₹5.1 L (10.5%)Rejected-Finance | L4 | Rejected-Finance rejected being L4 | |
| 5 | L5₹54.3 L+₹5.5 L (11.3%)Rejected-Finance | L5 | Rejected-Finance rejected being L5 |
Tender Value
Refer Docs
EMD Value
₹92,000
Closing Date
31 Oct 2020, 6:00 pmClosed
GE I R AND D East Bangalore
GE RD East Bangalore 93
REPLACEMENT OF OLD PANEL BOARD AND REMOVAL OF CAPACITOR BANK AT HMFHPASE AND REPLACEMENT OF OF OLD SV LAMP TO LED FITTINGS AT ECS TF BUILDING AT TEST FACILITIES GROUP AT GTRE BANGALORE
2020_MES_385068_1
8975
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE I R AND D East Bangalore
D b (i)
8 documents required · 8 mandatory
₹500
Yes
GE I R AND D East Bangalore
₹92,000
Yes
22 Dec 2020
9 Oct 2020
5 Nov 2020
9 Oct 2020
31 Oct 2020
26 Oct 2020
10 Oct 2020 - 20 Oct 2020
Amount
M & L for point wiring complete with multi stranded copper conductor size 2.5Sqmm PVC insulated, unsheathed FRLS cable, cable 1100 Volts grade confirming to IS 694 multistranded, drawn in and including rigid PVC conduit concealed in wall modular type switches and sockets and also including 1.5Sqmm PVC insulated unsheathed copper cable green in colour as continuous earth continuity onductor and connecting to earth dolly, cutting chasis to walls/floors/ceiling and repairing with existing surface after work, complete all as specified and directed for for 3 pin 15 Amps socket outlet independently all as specified and as directed by Engr-in-Charge
Supply and fix switch modular type 1 way 16 Amp , 1 module all as specified and as directed
Supply and fix socket modular type 6/16A 2-3 pin combined 2 module, 230 Volts grade all as directed
Supply and fix single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20A complete all as specified and as as directed
Supply and fix three pole and neutral enclosure with a three pin and earth plug and socket complete with one three pole MCB 32A complete all as specified and as directed
Supply and fix three pole and neutral enclosure with a three pin and earth plug and socket of capaity 125Amps complete all as specified and as as directed Make : Legrand Cat Part No. for surface mounted socket 3P+N+E - 555659 and straight plug 3P+N+E - 555629 or equivalent in L&T/IndoAsian
M & L for sub main wiring complete with 2 runs of 6 Sqmm PVC insulated and unsheathed cable with multistranded copper conductor confirming to IS-649, 1100 volts grade and drawn through and including steel conduits and conduit accessories concealed and connecting terminal ends including 1 run of 4 Sqmm of PVC insulated unsheathed copper conductor cable green colour as earth continuity conductor and connecting to earth dolly including removing unserviceable sub main wiring complete all as directed and specified for ACs Note :-(i) One run of PVC conduit, two runs of copper cable and one run of earth wire shall be measured and paid as one unit.
M & L for sub main wiring complete with 4 runs of 10 Sqmm PVC insulated and unsheathed cable with multistranded copper conductor confirming to IS-649, 1100 volts grade and drawn through and including steel conduits and conduit accessories concealed and connecting terminal ends including 1 run of 6 Sqmm of PVC insulated unsheathed copper conductor cable green colour as earth continuity conductor and connecting to earth dolly including removing unserviceable sub main wiring complete all as directed and specified Note :-(i) One run of PVC conduit, four runs of copper cable and one run of earth wire shall be measured and paid as one unit.
S & F MCB DB TPN 4 way 415 Volts Double door type 4 way complete all as specified and directed
S & F MCB TPN 415 Volts 32 Amps 10kA complete all as directed
S & F MCB SPN 240 Volts 20Amps complete all as directed
M & L for earthing complete with galvanised steel earth plate electrode 60 x 60cm x 6mm thick , buried directly in ground (earth pit not less than 2.25metre deep below normal groud level ) with top edge of the plate not less than 1.5 metres below normal ground level connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel including necessary excavation and earth work (in any of strata) providing charcoal dust, salt mixed with fine sand in continuous layers, PCC (1:3:6 ) type C1 in chember ,Precast 50 mm thick in cement ( 1: 2:4) type B.1 with CI frame with cover, 20mm dia bore light grade GI watering pipe furnel etc fixing of GI Pipe 40 mm bore protection for earthing strip from earth pit to test point complete & making connection all as specified in Electrical plate No 3 and as directed by Engineer-in-Charge.
Supply, laying , jointing , testing and commissioning of LT under ground cable 1100 Volts grade XLPE (cross linked polyethene) armoured with galvanised round steel wire or steel strip, electric power cable heavy duty , with multi stranded aluminium conductor , fix on walls/poles with proper size saddles and clamp laid under roads/path/drain/culverts or enclosed in GI pipe/fix complete all as specified for size 400 Sqmm 3.5 core complete all as directed
Supply, laying , jointing , testing and commissioning of LT under ground cable 1100 Volts grade XLPE (cross linked polyethene) armoured with galvanised round steel wire or steel strip, electric power cable heavy duty , with multi stranded aluminium conductor fix on walls/poles with proper size saddles and clamp laid under roads/path/drain/culverts or enclosed in GI pipe/fix complete all as specified for size 16 Sqmm 4 core for ACs and 200Amps Industrial Sockets complete
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in deep and getting out in hard/dense soil for laying GI Pipe underground cable, foundation etc complete all as directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soils all as specified as directed.
Removing excavated material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all as specified and as directed
Material and labour for fine and dry sand cushioning for under ground cable including providing with layers of sand 8cm deep before laying the cable and 15 cm deep after laying the cable & stretching the cable complete all as specified and as directed.
Supply and laying well burnt brick sub class B of size 230mm x 115mm x 75mm in size, laid in trenches for cable protection complete all as specified and as directed.
Boring of holes under road, pavement, hardstandinig by trenchless technology using ultrasound technique and necessary maching including HDPE pipe of 110mm dia suitable for 0.4 mpa working pressure.
Supply, install, testing and commissioning of CPRI approved LT Panel board, outdoor cubicle , dust and vermin proof made out of 3.15mm thick MS sheet with front end back door openable type fitted with nuts, bolts and washers fitted with knobs and hinges iSupply, install, testing and commissioning of CPRI approved LT Panel board, outdoor cubicle , dust and vermin proof made out of 3.15mm thick MS sheet with front end back door openable type fitted with nuts, bolts and washers fitted with knobs and hingeainting with two coats of enamlled paint over a coat of red oxide primer suitablefor 415 Volts 50Hz,3 phase 4 wire suitable for Ppnel 1 and including the following:-
Supply and fix Air cooled split unit air conditioner electric driven single phase of capacity of 2 TR, BEE 5 star rated completed including all fittings and fixtures all as specified and as directed
S & F voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 volts to 250 volts with out put voltage stabilized at 230 volts with accuracy of +/- 2.5% and of capacity 5 KVA. Model VDN 500
M & L for copper tubing 24 SWG 3/8 and 5/8 inches dia of superior quality suitable for refrigeration suction/ discharge line along with tubular rubber insulation suitable for air conditioners.
Making opening / drilling of size 65mm dia using heavy duty stone driller / cutter machine in the stone masonry wall for installing split type air conditioners and for passing suction and discharge refrigerant pipe lines, drain pipe, cable etc, complete all as specified and directed.
M & L for MS stand duly painted suitable for fixing 2/1.5 TR AC out door unit and fixed complete all as directed.
Supply & install, testing and commissioning indoor type LT electric panel consisting separate compartment for each out going feeders with locking arrangement for each feeder fabricated out of 2 mm thick MS sheet floor mounting type suitable size base frame/channel, painted with powder coated and pre coted primer including necessary PCC 1:3:6 type C2 foundation of panel boad and earth work including comprising the following :- (a) Bus bar chamber of 3 phase and neutral 4 strip 415 volts with 2400Amps copper strip - 1 set (b) Easy Pact MVS Air circuit breaker Draw-out Type circuit breaker with Microprocessor based ET6G Trip Unit with display 4 pole 1600 Amps capacity - 1 No (In coming) (c) Moulded Case Circuit Breaker 4 pole 50 KA breaking capacity 800 Amps capacity with thermal magnetic trip unit (TMD) - 02 No (Out going) (d) Moulded Case Circuit Breaker 4 pole 25 KA breaking capacity 200 Amps capacity with thermal magnetic trip unit (TMD) - 02 No (Out going) (e) Moulded Case Circuit Breaker 4 pole 25 KA breaking capacity 100 Amps capacity with thermal magnetic trip unit (TMD) - 02 No (Out going) (f) Three phase volt meter 1.0 - 01 No (g) LED Indicator lamp Red, Yellow, Blue - 01 Set (h) Three phase Ammeter 1.0 - 01 No Note : (i) All termination of existing cable should be provided with copper lugs/thimbles and suitable size of glands & rate for the same is deemed to be included in the item
Supply & install, testing and commissioning indoor type LT electric panel consisting separate compartment for each out going feeders with locking arrangement for each feeder fabricated out of 2 mm thick MS sheet floor mounting type suitable size base frame/channel, painted with powder coated and pre coted primer including necessary PCC 1:3:6 type C2 foundation of panel boad and earth work including comprising the following :- (a) Bus bar chamber of 3 phase and neutral 4 strip 415 volts with 2000 Amps copper strip - 1 set (b) Easy Pact MVS Air circuit breaker Draw-out Type circuit breaker with Microprocessor based ET6G Trip Unit with display 4 pole 1250 Amps capacity - 1 No (In coming) (c) Moulded Case Circuit Breaker 4 pole 36 KA breaking capacity1000 Amps capacity with thermal magnetic trip unit (TMD) - 01 No (Out going) (d) Moulded Case Circuit Breaker 4 pole 36 KA breaking capacity 400 Amps capacity with thermal magnetic trip unit (TMD) - 03 No (Out going) (e) Moulded Case Circuit Breaker 4 pole 25 KA breaking capacity 100 Amps capacity with thermal magnetic trip unit (TMD) - 04 No (Out going) (f) Three phase volt meter 1.0 - 01 No (g) LED Indicator lamp Red, Yellow, Blue - 01 Set (h) Three phase Ammeter 1.0 - 01 No (j) Provision of extra space for two more outgoing feeders suiable for 400 Amp MCCB Note : (i) All termination of existing cable should be provided with copper lugs/thimbles and suitable size of glands & rate for the same is deemed to be included in the item
M & L for dismantling the existing old vintage capacitor bank panel 01 Nos and LT Indoor panel (02 Nos) at HMFHPASF after disconnecting electric supply from the system all as specified and directed.
S& F LED high bay fittings 150 W , rectangular high bay with excellent heat sink alongwih IP 66 protection, with suitable bracket on wall and necessary indluding connecting with twin copper conductor of size 2.5 sqmm complete all as specifed and directed. Make: Crompton Greaves/Havells/Bajaj
M&L Point wiring complete with 1.5 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable 1100 Volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit (minimum 20 mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I, ISI marked with wall thickness not less than 1.8 mm including conduit accessories like bends, tees, junction boxes etc fixed concealed/ recessed in wall or ceiling etc including 1.5 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire including modular type metal flush box with cover plate and frame of required module for mounting of modular switches, sockets, switch sockets, fan regulators with required modules all as specified etc for the following:-
a) One light point controlled by one 5 Amps one way switch
b) One celing/exhaust fan point controlled by one 5 Amps one-way switch and regulator.
Supply and fix modular switch one way 6 Amp, 1 module with frame and cover 230 Volts complete
Supply and Ceiling rose surface backlite three terminal complete all as specified and directed.
M & L for refixing of ceiling /exhaust fan of any sweep on ceiling after reparing in workshop by rewinding/replacement of bush, bearing, three core flexible wire from ceiling rose to fan , rubber bush, nuts and bolts /washers and small spares including painting with synthetic enamel paint and making the fan serviceable in all aspect all as specified and as directed.
Supply and fixing LED surface and wall mounted LED battern extruded aluminium bousing provided for efficient heat dissipation with polycorbonate diffuser & integrated electronic drivero of 20 Watts all as specified and as directed.
S&F in replacement Sheet steel metal enclosure distribution box double door, SPN MCB DB double door SPN for MCB 8 Way 240Volts, flush mounting CRCA powder coated with 200 Amps rated bus bar complete
S & F MCB SPN 40 AMP 10 KA capacity 240 volts all as specified and direcred. Make :- Indo Asian/C&S/Legrand
S & F MCB Single pole 6 to 32 Amp 40 AMP 10 KA capacity 240 volts all as specified and direcred. Make :- Indo Asian/C&S/Legrand
M & L for submain wiring of 2 run 2.5Sqmm size PVC insulated unsheathed multistranded copper conductor 1100 Volts FRLS grade drawn through and including suitable size of PVC conduit accessories concealed in wall/roof including one run of 2.5 Sqmm PVC insulated multistranded copper wire for earth , ISI marked and connecting up complete including removing old unserviceable cables all as specified and directed by Engr-in-Charge Note :-(i) One run of PVC conduit, 2 runs of copper cable and one run of earth wire shall be measured and paid as one unit.
M&L Earthing complete with galvanised steel earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground( earth pit not less than 2.25metres deep below the normal ground level) with top edge of the plate not less than 1.5m below normal GL connected as required 32 x 6mm upto 7.5Mtr GI strip up to means of GI bolts, nuts , check nuts and washers and connected to building panel/DB including taking down old unserviceable earthing and necessary excavation and earth work (in any of strata) providing charcoal dust, salt mixed with fine sand in continuous layers, PCC (1:3:6 ) type C1 in chember ,Precast 50 mm thick in cement ( 1: 2:4) type B.1 with CI frame with cover, 20mm dia bore light grade GI watering pipe furnel etc fixing of GI Pipe 40 mm bore protection for earthing strip from earth pit to test point complete & making connection all as specified in Electrical plate No 3 and as directed by Engineer-in-Charge.
S&F Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/GI pipe or fixed to poles or any other indicated situation for loop earthing etc as required of GI strip 20 x 3 mm complete all as specified and as directed
RAHUL ENTERPRISES
R R Constructions
UNITED ENGINEERS CORPORATION
AishwaryaConstructions
Meghana and Gowda Enterprises
Vishwas Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .