Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.7 LAccepted-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | L1 | Accepted-Finance L1 | |
| 2 | L2₹7.2 L+₹51,231 (7.63%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | L2 | Rejected-Finance L2 | |
| 3 | L3₹7.3 L+₹55,440 (8.25%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹8.1 L+₹1.4 L (20.9%)Rejected-Finance A 303 VEENA CGHS LTD PLOT NO 5D SECTOR 22 DWARKA NEW DELHI 110077 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110077 | L4 | Rejected-Finance L4 | |
| 5 | L5₹9.9 L+₹3.2 L (48.1%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
12 Oct 2021, 6:00 pmClosed
GE AF FARIDABAD
Garrison Engineer AF Faridabad Dabua Colony Faridabad Haryana Pin-121005
REPAIR OF DG SETS LT PANELS MCCBS OLD US CABLE AND EARTH PITS AND CONNECTED WORKS IN TECH AREA AND OFFICER MESS AT MCC AIR FORCE STATION BASANT NAGAR
2021_MES_476854_1
GE (FBD)/AF-45/2021-2022
Open Tender
Civil Works
Item Rate
180 days
PALAM
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF FARIDABAD
₹20,000
Yes
26 Nov 2021
21 Sept 2021
19 Oct 2021
21 Sept 2021
12 Oct 2021
28 Sept 2021
22 Sept 2021 - 27 Sept 2021
Amount
Maintenance/repair to 320 KVA Gen set installed at sub station by replacement of lubricant oil filter fuel oil filter bye pass filter, “O’ ring, fuel filter water separator assembly, draining out un serviceable engine oil, cleaning of pump, checking & tightening of mounting nut & bolts, crank case, cleaning of valves, battery terminals, checking of radiator, PH value of coolant, topping with premixed coolant and inhibitor corrosion testing the engine on load and checking for any leakage of oil/fuel/coolant complete all as specified and directed by Engineer-in-Charge. Note :-(i) Parts required for replacement will be measured and paid separately under Schedule ‘A’ item (ii) The contractor will be responsible for attending any complaint/defect occurs to DG set at odd hours during operation. If the defects are not attended within 4-6 hrs recovery of Rs. 300/- per day will be effected (iii) The contractor has to submit the responsibility certificate of all changed/repaired parts for six months from the date of servicing/repair.
Supply only Element lub oil filter Cartrige . Kirloskar cat part No KV0.043.03.0.00 complete all as specified and directed by Engineer-in-Charge.
Supply only fuel filtter Cartage Kirloskar cat part No KV0.110.01.0.00 complete all as specified and directed by Engineer-in-Charge.
Supply only Pre Filter Assembly Kirlosker part No KV2.506.20.0.00 complete all as specified and directed by Eng-in -charge.
Supply only seal 'O' ring Make- Kirloskar complete all as specified and directed by Eng-in -charge.
Supply only KOEL Care genuine oil Kirloskar Part No 82.050.10.0.20 complete all as specified and directed by Engineer-in-Charge.
Supply only K-COOL super plus Coolent Kirloskar part No - 82.020.35.1.05 complete all as specified and directed by Engineer-in-Charge.
Supply only Air Filter for 320 KVA DG Set . Make :-Kirloskar complete all as specified and directed by Engineer-in-Charge.
Supply only distilled water complete all as specified and directed by Engineer-in-Charge.
Supply only Battery terminals complete all as specified and directed by Engineer-in-Charge.
Maintenance/repair to 75 KVA Gen set " Greevs" installed at sub station in Basant Nagar Officer's Mess by replacement of lubricant oil filter fuel oil filter bye pass filter, “O’ ring, fuel filter water separator assembly, draining out un serviceable engine oil, cleaning of pump, checking & tightening of mounting nut & bolts, crank case, cleaning of valves, battery terminals, checking of radiator, PH value of coolant, topping with premixed coolant and inhibitor corrosion testing the engine on load and checking for any leakage of oil/fuel/coolant complete all as specified and directed by Engineer-in-Charge. Note :- (i) Parts required for replacement will be measured and paid separately under Schedule ‘A’ item (ii) The contractor will be responsible for attending any complaint/defect occurs to DG set at odd hours during operation. If the defects are not attended within 4-6 hrs recovery of Rs. 300/- per day will be effected (iii) The contractor has to submit the responsibility certificate of all changed/repaired parts for six months from the date of servicing/repair.
Supply only Element lub oil filter Cartrige complete all as specified and directed by Engineer-in-Charge.
Supply only fuel filtter Cartage complete all as specified and directed by Engineer-in-Charge.
Supply only Pre Filter Assembly complete all as specified and directed by Engineer-in-Charge.
Supply only seal 'O' ring Make- Kirloskar complete all as specified and directed by Engineer-in-Charge.
Supply only genuine Engine oil Make- Servo/Castrole complete all as specified and directed by Eng-in -charge.
Supply only Coolent complete all as specified and directed by Eng-in -charge.
Supply only Air Filter for 75 KVA DG Set complete all as specified and directed by Eng-in -charge.
Supply only distilled water.complete all as specified and directed by Eng-in -charge.
M&L for repair of PCB suitable for 320 KVA DG set AMF panel complete all as specified and directed .
M&L for repair of AVR Unit of 320 KVA DG Set complete all as specified and directed by Engr-In-Charge.
M&L for Repair of Self starter of 320 KVA DG Set complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of fuel pipe of DG set connecting from inlet of the tank to dg set complete all as specified and directed by Engineer-in-Charge.
S&F in repair of Digital maltifunctional power meter for AMF panel complete all as specified and directed by Engineer-in-Charge.
Supply and replacement of V belt for radiator fan suitable for 320 KVA DG set as per sample complete all as specified and directed by Engineer-in-Charge.
M&L for repair/replacement of battery 12 volts, 180 amh complete all as specified and directed by Engineer-in-Charge. Make :Exide/Amron/SF.
M&L for complete oherhauling of Engine incl opening of engine head of 320 KVA DG Set carefully and Servicing of internal parts of engine, piston, lining etc and entire assembly and fixing the parts after opening complete all as specified and directed by Engineer-in-Charge. Note :- Spare part are paid separately.
M&L for replacement of the following unserviceable parts of 320 KVA DG set as per the existing Kirloskar model of the DG set complete all as specified and directed by Engineer-in-Charge:- (a) Piston
(b) Ring set
(c) Piston pin
(d) CR Bearing
(e) Head valve
(f) Head Gas kit
(g) Head seal
(h) Packing kit of the engine
S&F in replacement of water pump suitable for 320 KVA DG Set complete all as specified and directed by Engineer-in-Charge. Make- Kirloskar
M&L for replacement of engine lining after complete opening of engine of 320 KVA DG Set including topup of engine oil complete all as specified and directed by Engineer-in-Charge.
M&L for Repair of fuel nozzeles of 320 KVA DG Set complete all as specified and directed by Engineer-in-Charge.
M&L for repair of turbocharger of 320 KVA DG SET complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of Battery charger 24 V DC with digital display complete all as specified and directed by Engineer-in-Charge.
M&L for Design, development, supply commissioning and testing EHCC certified ground tubular effective chemical earthing system (CPRI tested for 15 KA current capacity for LT Iine) highly anticorrosive long life electrode with and including adequate protective coating to withstand servere weather conditions in the earth pit of the standard size comprising of 40mm x 3m Long Copper rod as primary conductor and hollow copper tube of 80mm x 3m long as secondary conductor to install with suitable connecting terminal confirming of IS 3043 : 1987 specification, highly conductive packing material to be filled in earth pits for providing uniform, low resistivity anticorrosive, hygroscopic medium around the earth system for improving the efficiency of current dissipation with crystalline conductive mixture (CCM) 20 Kg per bag (3 bag per kit) minimum or sufficient quanitities required as per site complete including RCC earthing pit cover , material and labour complete all as specified and directed by Engineer-in-Charge.
Dewatering the existing U/G sump of 20000 Ltrs capacity and cleaning the internal surface of sump for removing scales, funges, mud and other foreign material ,scrubbing with water using wire brush and watering the surfaces with mixture of bleaching powder and water ,finally washing with fresh water and treating with one coat of lime wash to internal wall and bottom surfaces etc complete for one time,writing in enamel paint note in block capital letter as cleaned on (date) and due date etc,height not less than 5 cm complete all as specified and directed by Engineer-in-Charge.
M&L for repair of centrifugal pump of capacity 5 hp ,3 phase shifting to workshop Complete opening for rewinding with super enamled copper wire of existing size & repair/replacement of worn out parts such as shaft,Ball bearing, bush, impellers, coupling ,mechanical seal,jet assembly etc including re-assembling and refixing in position complete all as specified and directed by Engineer-in-Charge.
M&L for disconnecting the main supply & taking out the submersible pump capacity 10 HP , 3 phase from the borewell with the help of Chain pulley arrangement and shifting to the workshop and back after rewinding and repair/replacement of wornout parts including refixing with complete electric and water pipe connections & testing after installing complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement MCCB 630 Amps ,3 Pole ,36 KA ,50 Hz ,415 Volt including under voltage/over voltage relay,adjustable overload setting and short circuit setting complete all as specified and directed by Engineer-in-Charge. Make :-Havells/Indoasian /L&T
Supply and fix in repair Air termination, single pointed, copper rod 12mm dia and 300mm long complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair Copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of starter panel for 10 HP motor ,3 phase ,415 V in sheet enclosure including phase corretor complete all as specified and directed by Engineer-in-Charge. Make :- L&T /HPL/Indoasian
Supply and fix in replacement of starter panel for 5 HP motor ,3 phase ,415 V in sheet enclosure including phase corretor complete all as specified and directed by Engineer-in-Charge. Make :- L&T /HPL/Indoasian
Suply and fix in replacement of Sheet metal enclosure for MCCB 3P, one no complete all as specified and directed by Engineer-in-Charge.
S&F in repair wall mounted TPN busbar chamber factory made with busbar of current rating 400 Amp, 415, 4 way complete all as specified and directed by Engineer-in-Charge.
Supply and fixed in repair,MCCB 400 Amp ,3 pole, microprocessor based thermal magnetic type ,36 KA including under voltage/over voltage relay complete all as specified and directed by Engineer-in-Charge. Make : -HPL TABBASIX2200C3P/Havells/indoasian)
Taking out old rusted solar water heater tank of capacity 100-150 ltr and Supply and fix new solar water heater tank of same capacity incluted connection of water inlet and outlet and including heating element of 2 kW complete all as specified and directed by Engineer-in-Charge.
M&L for scrapping of surface of steel tubular poles of any size with emery paper and painting of pole one coat of primer and two coats of silver colour paint including writing pole No on yellow colour with 30cm strip upto 1.5 Mtr height from ground level complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of Onload Changover switch 200 Amp, 4 pole ,415 V,50 Hz in sheet metal enclosure complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of Onload Changover switch 400 Amp, 4 pole ,415 V,50 Hz in sheet metal enclosure complete all as specified and directed by Engineer-in-Charge.
M& L for preparation of trench for cable laying of size 300mm x 450 x 10 m long including excavation, brickwork, PCC work , plastering and finishing complete all as specified and directed by Engineer-in-Charge.
Supply and fixed in repair,MCCB 250 Amp ,3 pole, microprocessor based thermal magnetic type ,25KA including under voltage/over voltage relay complete all as specified and directed by Engineer-in-Charge. Make : -HPL TABBASIX2200C3P/Havells/indoasian)
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ XLPE, armoured, Al conductor cable of size 16 to 35 sqmm,Outdoor type complete all as specified and directed by Engineer-in-Charge.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ XLPE, armoured, Al conductor cable of size 70 to 95 sqmm,Outdoor type complete all as specified and directed by Engineer-in-Charge.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ XLPE, armoured, Al conductor cable of size 150 to 185 sqmm,Outdoor type complete all as specified and directed by Engineer-in-Charge.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ XLPE, armoured, Al conductor cable of size 300 to 400 sqmm,Outdoor type complete all as specified and directed by Engineer-in-Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 sq mm 3.5 core complete all as specified and directed by Engineer-in-Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 400 sq mm 3.5 core complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches not exceeding 1.5 m wide and and not exceeding 1.5 m depth in loose/soft soil and getting out complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, with excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25 cm, complete all as specified and directed by Engineer-in-Charge.
Removal of surplus soil to distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified and directed by Engineer-in-Charge.
M & L for brick protection with sub class 'B' bricks laid dry flat over electric cable in trenches all as specified and directed by Engineer-in Charge.
M & Labour for sand cushioning with a layer of sand 80mm thick consolidated before laying of cable and 150mm thick consolidated after laying of cable in trenches ducts for electric cable protection including consolidation complete all as specified and directed by Engineer-in-Charge.
Supply, installing testing and commissioning starter panel in replacement of factory made and tested (Including CPRI test cetified) indoor type floor mounted LT panel board, cubical type suitable for 415 Volts 3 phase, 4 wire 50Hz, Ac supply system having busbar chember with insulated AL busbar of rating 100 A for phase installed on porcelin/SMC insulators. The panel shall be dust and vermin proof IP-54 class protection and made out of 2.00 mm thick CRCA MS sheet and angle iron frame 40x 40x 6mm thick frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coat of red oxide primer, front and back opening type with aproaches for cable entry with double door shutter and locking arrangements including internal wiring with PVC insulated stranded copper conductor cable FRLS IS 694 sheathed 1100V grade of appropriate size. The panel shall be comprising of following:- Incomer section (i) 63A TP MCCB 16 Ka Make : Legrand/L&T/ Seimens (ii) RYB indication Lamps,220V AC Make : Vaishno/Teknic (iv)Current Transformer, 60/5A, C1-1.0 Make ; Hind Asia/AE (v) MCB-6A SP, 6A Make: Hager/Legrand (vi) Power Contactor, 40A, TP Make: Legrand/L&T (vii) Mechnical Interlock for contactor, Make : Legrand/L&T (viii) Phase Sensor, (x) Aux. Relay, 2C/o Make : Omron
Commercial Traders
JAIPAL and BROS
Ridhi engineers and builders
Surjit and Sons
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .