| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹3.9 LAccepted-AOC AT BACHRA P O BACHRA P S PIPARWAR BACHRA 829201 | BACHRA | CHATRA | JHARKHAND | 829201 | ₹3.9 L Quoted ₹3.3 L | L-1 | Accepted-AOC L-1 |
| 2 | L-2₹3.4 LRejected-Finance AT MOHAN NAGAR PO DAKRA PS KHALARI DISTT RANCHI JHARKHAND 829201 | CHATRA | JHARKHAND | 829201 | ₹3.4 L | L-2 | Rejected-Finance L-2 |
| 3 | Rejected-Technical AT BACHRA P O BACHRA DIST CHATRA JHARKHAND | CHATRA | JHARKHAND | 825103 | - | - | Rejected-Technical All documents are not as per e-NIT |
| 4 | Rejected-Technical AT P O BACHRA P S PIPARWAR PIN 829201 | CHATRA | JHARKHAND | 829201 | - | - | Rejected-Technical All documents are not as per e-NIT |
| Sl No | Description | Qty | Unit | M/S ASHOK ENTERPRISES L1 | M/S MAA CONSTRUCTION L2 |
|---|---|---|---|---|---|
| 1.00 | Wiring for light point /exhaust fan point/ with 1.5 Sq. mm FRLS PVC insulated copper single core cable in surface/recessed medium class PVC conduit with Piano type switch, phenolic laminated sheet suitable size M.S /PVC box and earthing the point with 1.5Sq mm FRLS PVC insulated copper single core cable etc. Required. | 108 | point | 1,026.02 ₹1.1 L | 1,068.18 ₹1.2 L |
| 2.00 | Wiring for circuit/Sub mains wiring along with wire with theFRLS PVC insulated copper conductor single core cable in surface/recess medium class PVC conduit as required 2x1.5 Sqmm+1x1.5 Sq. mm earth wire. | 216 | mtr. | 208.05 ₹44,938.80 | 216.6 ₹46,785.60 |
| 3.00 | Supplying and fixing 15/16 Amp Switch | 23 | no. | 108.41 ₹2,493.43 | 112.86 ₹2,595.78 |
| 4.00 | Supplying and fixing 6pin 15/16 Amp Socket outlet | 23 | no. | 123.74 ₹2,846.02 | 128.82 ₹2,962.86 |
| 5.00 | Supplying and fixing 5/6 Amp Switch | 20 | no. | 44.9 ₹898 | 46.74 ₹934.80 |
| 6.00 | Supplying and fixing 5/6 Amp Switch | 20 | no. | 61.32 ₹1,226.40 | 63.84 ₹1,276.80 |
| 7.00 | Wiring for circuit/ sub main along with earth wire 2x 2.5 Sqmm+ 1x 2.5 Sqmm earth wire as per required. | 265 | mtr. | 248.57 ₹65,871.05 | 258.78 ₹68,576.70 |
| 8.00 | Supplying and fixing of 5 amps to 32 amps, 240/415 V MCB with testing and commissioning etc. as required. | 26 | no. | 235.43 ₹6,121.18 | 245.1 ₹6,372.60 |
| 9.00 | Supplying and fixing of SP and neutral | 11 | no. | 563.93 ₹6,203.23 | 587.1 ₹6,458.10 |
| 10.00 | Supplying and fixing following way,single pole and neutral,sheet steel,MCB distribution board,240V,on surface/recess,complete withtinned copper bus bar,neutral busbar,earthbar,dinbar,interconnections,powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). | 4 | no. | 2,056.41 ₹8,225.64 | 2,140.92 ₹8,563.68 |
Tender Value
₹3.5 L
EMD Value
₹4,500
Closing Date
2 Jun 2025, 5:00 pmClosed
PE(Electrical)
OFFICE OF PO CHP-CPP, Piparwar Area, CCL, PO - Bachra, Dist - Chatra, Jharkhand - 829201 CHP-CPP,PIPARWAR
Repairing/rewiring/Service connection of 7 No. Qtrs. 1) Qtr. No C/C-6 Vasant vihar colony of Sri Nirmal Kumar Murmu and Kailash pd. mahto jointly allotted designation Asst. Mgr. ,2) Qtr. No-B-09 in Vasant vihar colony of Sri Birendar Bhagat desgn. F
2025_CCL_335971_1
PE/Elec/CHP/PPR/e-NIT/25-26/03
Open Tender
Electrical and Maintenance Works
20 days
OFFICE OF PO CHP-CPP, Piparwar Area, CCL
2 documents required · 2 mandatory
₹4,500
Yes
24 May 2026
22 May 2025
3 Jun 2025
22 May 2025
2 Jun 2025
22 May 2025
22 May 2025 - 29 May 2025
Amount
Wiring for light point /exhaust fan point/ with 1.5 Sq. mm FRLS PVC insulated copper single core cable in surface/recessed medium class PVC conduit with Piano type switch, phenolic laminated sheet suitable size M.S /PVC box and earthing the point with 1.5Sq mm FRLS PVC insulated copper single core cable etc. Required.
Wiring for circuit/Sub mains wiring along with wire with theFRLS PVC insulated copper conductor single core cable in surface/recess medium class PVC conduit as required 2x1.5 Sqmm+1x1.5 Sq. mm earth wire.
Supplying and fixing 15/16 Amp Switch
Supplying and fixing 6pin 15/16 Amp Socket outlet
Supplying and fixing 5/6 Amp Switch
Supplying and fixing 5/6 Amp Switch
Wiring for circuit/ sub main along with earth wire 2x 2.5 Sqmm+ 1x 2.5 Sqmm earth wire as per required.
Supplying and fixing of 5 amps to 32 amps, 240/415 V MCB with testing and commissioning etc. as required.
Supplying and fixing of SP and neutral
Supplying and fixing following way,single pole and neutral,sheet steel,MCB distribution board,240V,on surface/recess,complete withtinned copper bus bar,neutral busbar,earthbar,dinbar,interconnections,powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
Supplying and fixing of stepped type electronic fan regulator on existing modular plate switch box including connection as required
Supply and drawing 2x6 Sqmm cable of the FRLS PVC insulated copper conductor single core cable in surface/recess medium class PVC conduit as required for Service connection
Providing and fixing following capacity 63 A, TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.
Supplying LED Bulkhead Light .
Total impact of GST for the purpose of CTC
M/S MAA CONSTRUCTION (BID ID -1156021)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid