| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.8 CrAdmitted-Finance 180 10 STREET NO 10 HARPAL NAGAR NEAR TRIVENI MANDIR BHATTI ROAD BATHINDA 151001 | BATHINDA | PUNJAB | 151001 | ₹2.8 Cr | L1 | Admitted-Finance |
| 2 | L2₹2.9 Cr+₹7.4 L (2.61%)Admitted-Finance | ₹2.9 Cr+₹7.4 L (2.61%) | L2 | Admitted-Finance |
| 3 | L3₹2.9 Cr+₹10.9 L (3.87%)Admitted-Finance H NO 282 GREEN CITY II BATHINDA | BATHINDA | PUNJAB | 151001 | ₹2.9 Cr+₹10.9 L (3.87%) | L3 | Admitted-Finance |
| 4 | L4₹3.0 Cr+₹17.5 L (6.18%)Admitted-Finance 598 ST NO 3 SHAKTI NAGAR AMRIK SINGH ROAD BATHINDA BATHINDA PUNJAB 151001 | BATHINDA | PUNJAB | 151001 | ₹3.0 Cr+₹17.5 L (6.18%) | L4 | Admitted-Finance |
| 5 | L5₹3.1 Cr+₹26.6 L (9.40%)Admitted-Finance | ₹3.1 Cr+₹26.6 L (9.40%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | dyecon infra corporation private limited L7 | EVERCREST PROJECTS PVT LTD L6 | RAJ KUMAR GUPTA CONTRACTORS L5 | M/S Mittal Construction Company L1 | M/s Azure Infrastructure Construction Co. L3 | VARINDER KUMAR BANSAL CONTRACTOR L4 | KEWAL KRISHAN JINDAL L2 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00PART-A : CIVIL WORKS | ||||||||||
| 2.00 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 500 m and lift upto 2.0 m, as directed by Engineer-in-charge | 275 | cum | 61,875 ₹61,875 | 40,397.5 ₹40,397.5 | 37,125 ₹37,125 | 33,000 ₹33,000 | 22,000 ₹22,000 Lowest | 48,125 ₹48,125 | 33,000 ₹33,000 |
| 3.00 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 500 m outside the periphery of the area cleared. | 500 | sqm | 7,500 ₹7,500 | 6,215 ₹6,215 | 22,500 ₹22,500 | 4,000 ₹4,000 Lowest | 10,000 ₹10,000 | 7,000 ₹7,000 | 5,000 ₹5,000 |
| 4.00 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 20 mm nominal size) | 360 | cum | 16,20,000 ₹16,20,000 | 16,80,084 ₹16,80,084 | 12,85,200 ₹12,85,200 | 12,60,000 ₹12,60,000 | 10,08,000 ₹10,08,000 Lowest | 12,60,000 ₹12,60,000 | 19,80,000 ₹19,80,000 |
| 5.00Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering and reinforcement, including admixtures, if required, in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. Minimum Cement content considered in this item is @ 330 kg/cum. | ||||||||||
| 5.10 | All works upto plinth level | 180 | cum | 10,80,000 ₹10,80,000 | 10,85,749.2 ₹10,85,749.2 | 11,05,200 ₹11,05,200 | 8,64,000 ₹8,64,000 Lowest | 9,00,000 ₹9,00,000 | 11,34,000 ₹11,34,000 | 10,80,000 ₹10,80,000 |
| 5.20 | All works above plinth level upto floor V level | 210 | cum | 13,12,500 ₹13,12,500 | 12,66,707.4 ₹12,66,707.4 | 13,73,400 ₹13,73,400 | 10,71,000 ₹10,71,000 Lowest | 11,13,000 ₹11,13,000 | 13,65,000 ₹13,65,000 | 12,60,000 ₹12,60,000 |
| 6.00Centering and shuttering including strutting, propping etc. and removal of form work, all works in plinth level and in superstructure upto 10 mtr height in respective items | ||||||||||
| 6.10 | Foundations, footings, bases of columns, etc. for mass concrete up to plinth level | 250 | Sqm | 75,000 ₹75,000 | 54,522.5 ₹54,522.5 | 56,250 ₹56,250 | 87,500 ₹87,500 | 50,000 ₹50,000 Lowest | 75,000 ₹75,000 | 50,000 ₹50,000 Lowest |
| 6.20 | Lintels, beams, plinth beams, girders, bressumers and cantilevers upto 10 mtr height | 1,350 | Sqm | 6,07,500 ₹6,07,500 | 3,17,304 ₹3,17,304 Lowest | 6,07,500 ₹6,07,500 | 4,72,500 ₹4,72,500 | 4,72,500 ₹4,72,500 | 4,05,000 ₹4,05,000 | 8,10,000 ₹8,10,000 |
Tender Value
₹4.2 Cr
EMD Value
₹1 L
Closing Date
22 Jan 2021, 11:00 amClosed
DGM (Civil)
Civil Department NFL,Bathinda
Construction of Civil and Electrical works of Agro Chemical Plant at NFL Bathinda, Punjab
2020_NFL_65802_1
NFB/CIVIL/CW-280
Open Tender
Civil Works
Item Rate
270 days
bathinda
As mentioned in Eligibility Criteria
3 documents required · 3 mandatory
₹1,000
National Fertilizers ltd. Bathinda
₹1 L
16 Feb 2021
4 Jan 2021
23 Jan 2021
4 Jan 2021
22 Jan 2021
4 Jan 2021
4 Jan 2021 - 21 Jan 2021
PART-A : CIVIL WORKS
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 500 m and lift upto 2.0 m, as directed by Engineer-in-charge
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 500 m outside the periphery of the area cleared.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 20 mm nominal size)
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering and reinforcement, including admixtures, if required, in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. Minimum Cement content considered in this item is @ 330 kg/cum.
All works upto plinth level
All works above plinth level upto floor V level
Centering and shuttering including strutting, propping etc. and removal of form work, all works in plinth level and in superstructure upto 10 mtr height in respective items
Foundations, footings, bases of columns, etc. for mass concrete up to plinth level
Lintels, beams, plinth beams, girders, bressumers and cantilevers upto 10 mtr height
Columns, Pillars, Piers, Abutments, Posts and Struts up to 10 mtr height
Suspended floors, roofs, landings, balconies and access
Providing and laying Cement Concrete pavement of mix M-25 with ready mixed concrete from batching plant / site batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush,groove cutting upto 30 mm deep X 10 mm wide etc. complete as per specifications and directions of Engineer-incharge. Including floor top hardner as per manufacture specification for medium traffic condition. (Note:- Cement content considered in this item is @ 330 kg/cum.)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete Thermo-Mechanically Treated bars of grade Fe-500D or more, upto 10 mtr height complete as per drawing.
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer with 2 coats of Chlorinated rubber paint, including welding and bolted with special shaped washers etc. complete. As per drawing and directions of Engineer-In-Charge: Electric resistance or induction butt welded tubes complete as per drawing.
Providing and fixing precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sum as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineering- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete
Ridges plain (500 - 600mm)
Flashings/ Aprons.( Upto 600 mm)
Gutter (600 mm over all girth)
Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated 'J' or 'L' hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabilizer in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified 2 mm thick corrugated (2.5" or 4.2" or 6") or step-down (2" or 3" or 6" ) as specified
providing and fixing of multivent roof ventilators (turbo Venentilator) on the top of roof with high performance industrial multiroof ventilator of minimum 530 mm dia neck/ throat of aluminium alloy designed to a capacity of 1850 CFM at a high of 25 feet including pollycarbonate stretched from 3.00 mm thick sheet venture dome 1.5mm thick and aII required accessories as per technical specification. multi roof ventilators to be got approved from Engineer-in- charge before installation. The rate includes cutting making holes in the existing roofing sheets.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand)
15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 fine sand) for height upto 10m from ground level.
12 mm cement plaster of mix : Internal plaster 1:6 (1 cement : 6 fine sand) for height upto 10m from ground level.
6 mm cement plaster in ceiling of mix : 1:3 (1 cement : 3 fine sand)
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sq. mtr.
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : Two or more coats on new work over and including priming coat.
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colors such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete
Providing and fixing 1st quality ceramic glazed tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent
Providing and fixing alumnium work for doors, sliding windows, ventilators and partition with extruded built up standard tubular sectuions/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with rawl plugs and screws or with fixing clips or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, botton and sides with required EPDM rubber / PVC / neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/panelling, CP brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In-Charge. (Glazing and panelling to be paid for separately, under this item the weight of only Aluminium sections shall be taken for payment purpose).
For fixed portion (Powder coated aluminium minimum thickness of powder coating 50 micron)
For shutters of doors, sliding windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required including tower bolts, window locking arrangement etc..
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineering- charge. Pre-laminated particle board with decorative lamination on both sides.
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm)
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With stainless steel cover plate minimum 1.25 mm thickness
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5mm depth and 5 mm width
Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. complete as per direction of Engineer-incharge Powder coated minimum thickness 50 micron aluminium
Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineerin- charge: Extruded section profile size 42x50 mm
24 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness, fixed to the shutter styles by means of plastic/galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge. (For W.C. and bathroom door shutter).
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters including one coat of primer and two coats of Chlorinated rubber paint complete.
Extra for providing mechanical device chain and crank operation for operating rolling shutters. Exceeding 16.80 sqm in area
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work over and including one priming coat.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc
15 mm nominal outer dia Pipes
20 mm nominal outer dia Pipes
25 mm nominal outer dia Pipes
32 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge
32 mm nominal outer dia Pipes
50 mm nominal outer dia Pipes
75 mm nominal inner dia Pipes
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 300 mm dia. R.C.C. pipe
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes / sewer line pipe conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
Coupler 110 mm
110 mm Shoe
Single tee with door
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg)
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 150 x 100 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern with PVC connector with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Single half stall urinal with 5 litre P.V.C. automatic flushing cistern
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, PVC connection pipes including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern with PVC connector pipe, including flush pipe, controlled device (handle lever), conforming to IS : 7231, with all fittings and with manually fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with PVC connector pipe, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required Kitchen sink with drain board 510x1040 mm bowl depth 250 mm
Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required :
Providing and fixing C.P brass bib cock of approved quality : 15 mm nominal bore
Providing and fixing C.P brass stop cock of approved quality : 15 mm nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
25 mm nominal bore
50 mm nominal bore gun metal valve
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :
Rectangular shape 453x357 mm
Rectangular shape 1500x450 mm
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth: Granite Stone of approved shade
Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 20 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints ( 10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge (Item of joint fillers, sealants, Reinfoprcement bars, dowel bars with sleeve/ tie bars to be paid separately).
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
Providing and laying in position bitumen hot sealing compound for expansion joints etc. Using grade ‘A’ sealing compound (Unit - per cm depth per cm width per metre length)
Supplying and stacking at site: Good earth
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 500 m and lift upto 1.5 mtr
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 1 KM lead as per direction of Engineer - in- charge.
Demolishing Brick work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 1KM lead as per direction of Engineer-in- charge.
Dismantling structural steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and return the dismantelled material to NFL's main stores.
Demolishing cement concrete manually/ by mechanical means including disposal of material within 500 metres lead as per direction of Engineer - in - charge
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire and nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. Made of G.I. wire of dia 4 mm
Supplying and fixintg at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc embedded in cement concrete blocks45x45x 60 cm of mix 1:4:8 (1 cement:4 fine sand : 8 graded stone aggregate 20 mm nominal size), every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and struts embedded in cement concrete blocks 70x45x50 cm of the same mix, provided with G.I chain link fixed between the posts fitted including two coats of aluminium paint over one coat of primer (cost of G.I chain link fencing, earth work in excavation and concrete to be paid for separately).
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer and two coats of Chlorinated rubber paint using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Vitrified flooring Size of Tile 600x600 mm
Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/ opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection > 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity <0.043 w/ mK.
PART B-Electrical Works Note: It is expected that there shall be some variation in the quantities of Electrical works during execution of contract as per site requirement, which shall be in the preview of Engineer-in-charge NFL and Payment shall be made on actual measurement basis.
Cable
Supplying, Laying, testing and commissioning of following sizes of 1.1 KV XLPE, FRLS insulated, Aluminium/Copper conductor armoured( IS;1554 or latest amended up to date)/unarmoured cables.
4c x 16 sqmm Aluminium Armoured Cable from Emergency Lighting Panel to LPDB
4c x 16 sqmm Aluminium Armoured Cable from MLTP to Shade outgoings
4c x 16 sqmm Aluminium Armoured Cable from Emergency Lighting Panel to External Lighting Panel
4c x 25 sqmm Aluminium Armoured Cable from MLTP to AC DB
3.5cx 95 sqmm Aluminium Armoured Cable from MLTP to Emergency Panel, DG Panel to Emergency Panel
3c x 2.5 sqmm Copper UnArmoured Cable for Shed Light Circuit
3c x 2.5 sqmm Copper Armoured Cable for Street Light
3.5c X 400 sqmm Aluminium Armoured Cable (if cable laying on cable rack / in underground or on underground Trench, including digging with sand & brick)
Termination
Supply and making terminal joints for the following sizes of 1.1 KV XLPE insulated Aluminium/Copper conductor cable including providing complete as required Double compression glands, terminal lugs, crimping insulation tape effecting terminal connections.
4c x 16 sqmm Aluminium Armoured Cable from Emergency Lighting Panel to LPDB
4c x 16 sqmm Aluminium Armoured Cable from MLTP to Shade outgoings
4c x 16 sqmm Aluminium Armoured Cable from Emergency Lighting Panel to External Lighting Panel
3c x 2.5 sqmm Copper Armoured Cable for Street Light
3.5cx 400 sqmm AluminiumArmoured Cable
4c x 25 sqmm Aluminium Armoured Cable from MLTP to AC DB
3.5cx 95 sqmm Aluminium Armoured Cable from MLTP to Emergency Panel
Cable Tray
supply and erection of G.I perforated type cable tray of following sizes including supply of all materials as per specifications, drawings and directions of engineer-in-charge
150 mm wide x 40 mm height x 1.6 mm thick perforated type
300 mm wide x 40 mm height x 1.6 mm thick perforated type
450 mm wide x 40 mm height x 2 mm thick perforated type
Cable tray supports, supporting frame . the supports shall be painted with red oxide primer and aluminium paint. type of structural items required shall be MS angle 35x5mm, 50 x 6mm, Threded rod 8mm and Fastners.
Main LT Panel (Consisting of sl no 75.1 to 75.11)
Design, manufacture, supply inspection, handling, assembling, affecting proper connections, testing and commissioning of 14 SWG CRCA sheet steel fabricated cubical type Main L.T. Panel, floor mounting, dust & vermin proof, front operated construction, enclosure class - IP 52, powder coated, top/bottom removable gland plates, as required, earth bus with appropriate dimension, hinged and lockable doors to achieve dust and vermin proof complete with all inter connections small wiring by min. 2.5 sq. mm. FRLS copper wires, Cross ferulling in panel, ckt labels etc. The Aluminium Bus Bar shall be of suitable length, 500 volts, 3 phase 50 Hz TPN, electrolytic aluminium as per IS 8623 . The panel feeders shall be suitable for terminating suitable nos. 3.5 / 4 core armoured aluminium cable or Aluminium Bus Duct as required. The Pre-qualified OEM for LT Panel should be M/s L&T, GE Power, ABB, Siemens & Schneider only. The panel manufacturer sholud be either OEM OR its authorised dealers /manufaurerer.
Main Incomer-1
Main Incomer-2
Bus Coupler
1 No. 800 Amp 3P ACB, EDO of (50 KA) service breaking capacity with numeric feeder protection relay for O/c, S/C, E/F, Horizontal type draw out.
Bus Bars
1 No. of 1000 Amps TPN Aluminium Bus Bars of suitable length. Bus bars shall be insulated by heat shrinkable sleeves and clip on shrouds for joints. Bus bar shall be designed to with stand a fault level of (50KA) at 415 volts for 1 second. Cadmium coated bolts for busbar jointing. Colour identification of busbars. Outgoing (All MCCBs are Thermal Magnetic Based) 6 nos 250 Amp FP/3P+N SFU for 5 Plants & 1 Spare, 1 nos 160 Amp FP MCCB (25 KA) For Emergency Lighting Panel, 1 nos. 63 Amp FP MCCB (25 KA) For External Lighting Panel near Guard Room, 1 nos. 63 Amp FP MCCB (25 KA) For Shade1 & 2 outgoing, 1 nos. 100 Amp FP MCB (15 KA) For ACDB, 1 nos. 100 Amp FP MCB (15 KA)- Spare, 1 nos. 40 Amp FP MCB (10 KA)- Spare, 1 nos. 63 Amp FP MCB (10 KA)- Spare
FEEDER PILLAR
Emergency Lightning Panel for Backup Supply
INCOMER-1 : 160 AMP FP MCB (10 KA) from MLTP, INCOMER-2 : 160 AMP FP MCB (10 KA) from Backup Supply, Both breaker should be interlock through contactor of suitable rating, BUS BAR : 200 AMP, 500 Volts, 3 phase 50 HZ FP high conductivity electrolytic Aluminium bus bar. The current density of bus bar shall be minimum 1.00 sq mm/amp.OUT GOINGS : 1 nos. 100 AMP FP MCB (15 KA)- Spare , 2 nos. 63 AMP FP MCB (10 KA)-LPDB, 1 nos. 40 AMP FP MCB (10 KA)- LPDB, 1 nos. 40 AMP FP MCB (10 KA)- Spare, 1 nos. 63 AMP FP MCB (10 KA)-Spare
Earthing
Supply, installation & testing of (GI) advance maintenance free Chemical Gel Earthing of 3mtr long 50mm dia with 50 Kgs of mixture of Resistance Lowering Grounding Minerals. The indivugal earth pit resisitance should be less than 4 ohm. The Earth pit should be covered with CI Frame. The earth pit should have earth connection plate having the multiple holes to connect the interconnection earth pit of suitable rating ansd size plate to connect the outgings (For Body earthings)The earth strip has be coonect the disribution board , panel etc. All earth pit should be interconnected. All tall structures/buildings/equipment shall be given protection against lightning as per requirement laid down in relevant Indian/IEC standard.
50X6mm GI strip
32X6mm GI strip
25X6mm GI strip
Internal Points- MS Conduit should be used
Shed-1 (Head A)
Light Point Controlled By Switch
Supply, Installation, Testing & Commissioning of wiring for switch controlled light points with 2×1.5 sq. mm PVC insulated copper conductor 1100 Volt grade stranded flexible wires and including the cost of providing and fixing a 6 amp Modular Plate type switches with moulded cover plate in MS/GI/fibre box and including the cost of running 1 sq. mm PVC insulated copper earth wire for loop earthing etc. (Include Circuit Wiring)
Primary light point
Secondary loop point
Exhaust Fan Wiring
Supply, Installation, Testing & Commissioning of wiring for Exhaust Points with 2×1.5 sq. mm PVC insulated copper conductor 1100 Volt grade stranded flexible wires and including the cost of providing and fixing a 6 amp Modular Plate type switches with moulded cover plate in MS/GI/fibre box and including the cost of running 1 sq. mm PVC insulated copper earth wire for loop earthing etc. (Include Circuit Wiring)
Power Socket Wiring
Supply and wiring for a 1 nos. of 240 volt 6/16 amp single phase and neutral switch socket outlet with 2×4 sq. mm PVC insulated, stranded copper conductor 1100 Volt grade wires in suitable size 1.6 mm thick PVC surface/concealed conduit including cost of providing saddles etc as required for surface conduiting . Providing and fixing of 240 volt 16 amp socket outlet and 16 amp 240 volt single pole switch with moulded cover plate in recessed MS/GI/Fibre box and including earthing of the pin with 2.5 sq. mm PVC insulated solid copper earth wire for loop earthing complete as required.
Supply and wiring for a 1 nos. of 240 volt 6/16 amp single phase and neutral switch socket outlet with 2×2.5 sq. mm PVC insulated, stranded copper conductor 1100 Volt grade wires in suitable size 1.6 mm thick PVC surface/concealed conduit including cost of providing saddles etc as required for surface conduiting . Providing and fixing of 240 volt 16 amp socket outlet and 16 amp 240 volt single pole switch with moulded cover plate in recessed MS/GI/Fibre box and including earthing of the pin with 1.5 sq. mm PVC insulated solid copper earth wire for loop earthing complete as required. (Secondary Power Point to be tapped up by Primary)
Supply and Installation of Distribution Board:
Supply, Installation, Testing & Commissioning of distribution boards double door with enclosure & necessary MCB's minimum 10KA breaking capacity, interconnecting wires minimum size equivalant to sub main wiring etc including dressing, ferruling, thimbling of wires etc complete as per specifications, details as follows, and as per drawings.
LPDB - 6WAY TPN DB
Incomer:1 No. 40A, 4P MCB with 40A, 30mA, DP RCCB in each Phase, Outgoing:12Nos. 10/20/25/32A SP MCB's, LPDB - 06WAY TPN DB as described above.
Supply, Installation, Testing and Commissioning of 1 Nos. 63A FP MCCB with Metal Enclosure.
Shed-2 (Head B)
Internal Points
Light Point Controlled By Switch
Supply, Installation, Testing & Commissioning of wiring for switch controlled light points with 2×1.5 sq. mm PVC insulated copper conductor 1100 Volt grade stranded flexible wires and including the cost of providing and fixing a 6 amp Modular Plate type switches with moulded cover plate in MS/GI/fibre box and including the cost of running 1 sq. mm PVC insulated copper earth wire for loop earthing etc.(Include Circuit Wiring).
Primary light point
Secondary loop point
Light Point Controlled By Switch
Supply, Installation, Testing & Commissioning of wiring for switch controlled Highbay light points with 3×2.5 sq. mm PVC insulated copper conductor 1100 Volt grade stranded flexible cable and including the cost of providing and fixing a 6 amp Modular Plate type switches with moulded cover plate in MS/GI/fibre box. (Circuit Cost paid seperately).
Primary light point
Secondary loop point
Fan Point Controlled By Switch
Supply, Installation, Testing & Commissioning of wiring for switch controlled Fan Points with 2×1.5 sq. mm PVC insulated copper conductor 1100 Volt grade stranded flexible wires and including the cost of providing and fixing a 6 amp Modular Plate type switches with moulded cover plate in MS/GI/fibre box and including the cost of running 1 sq. mm PVC insulated copper earth wire for loop earthing etc. (Include Circuit Wiring).
Exhaust Fan Wiring
Supply, Installation, Testing & Commissioning of wiring for Exhaust Points with 2×1.5 sq. mm PVC insulated copper conductor 1100 Volt grade stranded flexible wires and including the cost of providing and fixing a 6 amp Modular Plate type switches with moulded cover plate in MS/GI/fibre box and including the cost of running 1 sq. mm PVC insulated copper earth wire for loop earthing etc. (Include Circuit Wiring).
Power Socket Wiring
Supply and wiring for a 1 nos. of 240 volt 6/16 amp single phase and neutral switch socket outlet with 2×4 sq. mm PVC insulated, stranded copper conductor 1100 Volt grade wires in suitable size 1.6 mm thick PVC surface/concealed conduit including cost of providing saddles etc as required for surface conduiting . Providing and fixing of 240 volt 16 amp socket outlet and 16 amp 240 volt single pole switch with moulded cover plate in recessed MS/GI/Fibre box and including earthing of the pin with 2.5 sq. mm PVC insulated solid copper earth wire for loop earthing complete as required.
Supply and wiring for a 1 nos. of 240 volt 6/16 amp single phase and neutral switch socket outlet with 2×2.5 sq. mm PVC insulated, stranded copper conductor 1100 Volt grade wires in suitable size 1.6 mm thick PVC surface/concealed conduit including cost of providing saddles etc as required for surface conduiting . Providing and fixing of 240 volt 16 amp socket outlet and 16 amp 240 volt single pole switch with moulded cover plate in recessed MS/GI/Fibre box and including earthing of the pin with 1.5 sq. mm PVC insulated solid copper earth wire for loop earthing complete as required. (Secondary Power Point to be tapped up by Primary)
Supply & wiring of 01 no 240 V 25 A Single phase & neutral socket oultet with 2 x 4 sq.mm PVC insualed copper cond. 1100 V grade with PVC conduit including shedel., providing 25 A Socket & 240 V MCB including box, earthing as per standard.
Supply and Installation of Distribution Board:
Supply, Installation, Testing & Commissioning of distribution boards double door with enclosure & necessary MCB's minimum 10KA breaking capacity, interconnecting wires minimum size equivalant to sub main wiring etc including dressing, ferruling, thimbling of wires etc complete as per specifications, details as follows, and as per drawings.
LPDB - 8WAY TPN DB
Incomer:1 No. 63A, 4P MCB with 63A, 30mA, DP RCCB in each Phase , Outgoing:18Nos. 10/20/25/32A SP MCB's , LPDB - 08WAY TPN DB as described above.
LPDB - 8WAY TPN DB
Incomer:1 No. 63A, 4P MCB with 63A, 30mA, DP RCCB in each Phase, Outgoing:04Nos. 10/20/25/32A SP MCB's, LPDB - 08WAY TPN DB as described above.
Telephone System
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. Make: Kalinga, AKG, Setia
Supply, fixing, connecting and testing of Telephone/computer modular sockets modular plate anodised MS box and blanking late in surface/recessed including connectionetc as required.
RJ-11 telephone socket two line with shutter
Supplying drawing, laying connecting and testing of 0.61mm dia annealed copper conductor PVC insulated PVC sheathed telephone Wire/cables in Existing/ New PVC conduit or a racks as required.
50 pair Telephone cable.
10 pair Telephone cable
Krone box - 50 pair along withTag block
Krone box - 10 pair along with tag block
Flexible drop wire for telephone sets
Bettle make telephone sets
Supplying and drawing of UTP 4 pair CAT 6 LAN/ Telephone Cable 5 pair in the existing surface/ recessed Steel/ PVC conduit as required.
1 run of cable
Supplying and fixing metal box of following sizes (nominal size) on surface or in reces with suitable size of phenolic laminated sheet cover in front including painting etc as required.
75 mm x 75 mm x 60 mm deep
Providing, fixing connecting and testing of solder less telephone Tag block of following capacity ties as required in suitable size of m.s. hinged lockable cover box duly painted etc. as required of Krone type.
50 pair Tele Tag Blk along with cable gland/ termination in electrical MCC room (To be fixed on the wall)
Supply, fixing, connecting and testing of RJ-45/RJ-11 as per requirement, face plate( computer line) with shutter DN-460 computer sockets modular plate anodised MS box and blanking late in surface/recessed including connectionetc as required.
Light Fixtures
Supply 'Installation, testing & commissioning of truss mounting type 150W highbay type Led light fixture, IP 66 IK-10 LED. Surge protection should be 6KV , Life span L-70 B-50 should be 50000 hrs. Efficiency of light should be 125 Lm/w or more.
Supply and fixing 20W (1200 mm) Surface mounted and wall mounted type Led tube light . THD should be less than 10%, Life span L-70 B-50 should be 50000 hrs. Efficacy of light should be 125 Lm/w or more, Driver should follow surge protection and safety test as per IS: 15885Part-2, 140V- 270V Voltage range.
Supply 'Installation, testing & commissioning of recessed mounting type 36W 600 X 600 mm Wave Led light fixture, IP 20. Life span L-70 B-50 should be 50000 hrs. Efficacy of light should be 140 Lm/w or more,Driver should follow surge protection and safety test as per IS: 15885 Part-2, (Optic should have high transmittance polystyrene opel diffusior)THD should be less than 20%.
Supply and fixing 2x20W (1200 mm) Surface mounted and wall mounted type Led tube light, The LED tube light should have less than 10% THD , Life span L-70 B-50 should be 50000 hrs. Efficacy of light should be 140 Lm/w or more,Driver should follow surge protection and safety test as per IS: 15885Part-2, The enclosure should be box type suitable for retrofit LED with G-13 . Single side connection for tube.
Supply 'Installation, testing & commissioning of Post top 40W LED. Life span L-70 B-50 should be 50000 hrs. Efficacy of light should be 140 Lm/w or more,Driver should follow surge protection and safety test as per IS: 15885Part-2,( Similar to Havells Ruby model)Voltage Range- 140V- 270V , single phase.
Supply 'Installation, testing & commissioning of 6W Led Down lighter LED light round in shapetube. Round recess type efficacy 100Lm/W or more SMD type with opel diffuser , Life L-70 B-50 35000Hrs, Driver should follow surge protection and safety test as per IS: 15885Part-2, Voltage range : 140-270V
Supplying, installing, Fixing, testing and commissioning of 1200 mm Celling Fan including all accessories as required, 70-75W range, Perl white in colour air delivery 230 m3 / min. Or more ( Similar to Havells SS390 mettalic or equivalent)
Supplying, installing, Fixing, testing and commissioning of 600 mm dia exhaust fan of Iron body with louvers. Including all accessories as required in Shed, rpm- 900, Colur gray, noise ( 60 Db - 70 Db) Air delivery 10000 cubm/hrs or more , wattage 500W.
Supplying, installing, Fixing, testing and commissioning of 250- 300 mm dia exhaust fan of PVC body with louvers. Including all accessories as required in wash room, single phase, rpm -1200 , Noise level ( 40-45 Db), Air delivery 800m3 / hr or more.
Supply, installation, testing and commissionin of 80W LED Street light along with Wall bracket for installation of pipe and LED light with IP66 IK-07 or more protection & integral electronic driver ( includes civil work and cable laying, clamping, fixing on wall, tray, etc.) The LED light should have less than 20% THD , Life span L-70 B-50 should be 50000 hrs. Efficacy of light should be 140 Lm/w or more,Driver should follow surge protection and safety test as per IS: 15885Part-2, 140V- 270V, Voltage range.
Fire & Safety Equipments
Supply and fixing in position the approved “Shock Treatment Charts” written in English and Local Language. These charts shall be framed in teak wood frame and covered with glass.
Supply and fixing in position the fire extinguishers Fladding Type carbon-di-oxide (CO2) type 4.5 Kgs capacity.
Supply and fixing of in position the fire extinguishers dry chemical powder (ABC) 5 kg capacity.
Supply and fixing of in-position the fire extinguishers dry chemical powder (ABC) 2 kg capacity.
Providing and fixing LT danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Supply and fixing in position 1000 mm wide rubber matting of 11 kV grade as per electricity rules. Thickness of rubber mat shall be not less than 12 mm.
Supply of fire buckets 5 nos. in each set duly filled with fine sand and fixed on an angle iron frame as per requirement of local authorities. Fire buckets shall be painted red from outside and white from inside with additional handle at the bottom.
Supply and fixing position the approved single line diagram framed in 1000 x 800 mm size glass frame and installed in main switch room.
Supply of First Aid box of approved make
SMOKE DETECTOR & FIRE ALARM PANEL (NOTE: Party has to connect the installed system and it is to be hooked up to the existing system of NFL)
Supply, installation, testing & commissioning of conventional optical smoke detector plus base, remote LED output, blinking LED, complete as required in acordance with laid specification or up to the satisfaction of engineer incharge ( Make:Honeywell or its equivalent)
Suply, installation, testing & commissioning of conventional heat detector (fixed temperature come ROR + base remote LED output, blinking LED, LPCB approved, complete as required in accordance with laid specification or up to the satisfaction of engineer incharge. Make: Honeywell or its equivalent
Suply, installation, testing & commissioning of conventional fire alarm hooter (sound output of minimum 90 dB upto a distance of 10 ft with strobe light of minimum of 75 cd intensity with power supply arrangement, complete as required and suitable for wall/ceiling mountain in accordance with laid specification or up to the satisfaction of engineer incharge. Make: ( Make:Honeywell or its equivalent)
Suply, installation, testing & commissioning with proper connection & termination of 2c x 1.5 sqmm Copper Armoured FRLS cable for fire detection system
Suply, installation, testing & commissioning with proper connection & termination of 4c x 1.5 sqmm Copper Armoured FRLS cable for fire detection system
Suply, installation, testing & commissioning of conventinal, manual call point, 24v operation, ABS housing with backbox, reset button complete as required to do the job in all respect in accordance with laid specification or up to the satisfaction of engineer incharge
Suply, installation, testing & commissioning of monitor module complete as required in accordance with laid specification or up to the satisfaction of engineer incharge
Suply, installation, testing & commissioning of conventional fire alarm panel of 4 zone. The panel shall have 240v AC supply, automatic battery charger, 24v. Sealed lead acid maintenance free batteries for sufficient for 24 hours working hourse and then capable of operating the system for 60 minutes during emergency conditions or upto the satisfaction of the engineer incharge. Make: Honeywell or its equivalent)
RCC/Hume Pipe
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. (For Cable Laying)
250 mm dia
300 mm dia
HDPE Pipe
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. including trenching (75 cm deep) and refilling etc as required., complete as required. (Used for Data, Fire & Telephone)
63 mm dia (OD-63 mm & ID-51 mm nominal)
Split AC Unit 1.5 TR. 230V AC, 5 Star rating ( including installation with 2 Pole MCB near AC unit) Make ( Carrier, Hitachi, Blue Star, Voltas)
KEWAL KRISHAN JINDAL
M/s Azure Infrastructure Construction Co.
VARINDER KUMAR BANSAL CONTRACTOR
RAJ KUMAR GUPTA CONTRACTORS
EVERCREST PROJECTS PVT LTD
dyecon infra corporation private limited
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.35 MB
CW280TenderGTC.pdf
Tender Documents • 0.97 MB
BOQ_71022.xls
BOQ • 0.60 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .