| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.0 LAccepted-AOC 30 INDUSTRIAL AREA KOKAR RANCHI 834004 JHARKHAND | RANCHI | JHARKHAND | 834004 | ₹28.0 L | L1 | Accepted-AOC Lowest quoted |
| 2 | L2₹32.2 L+₹4.1 L (14.8%)Rejected-Finance 119 LANE NO 4 DAYA NAND NAGAR LAWRENCE ROAD AMRITSAR PUNJAB 143001 | AMRITSAR | PUNJAB | 143001 | ₹32.2 L+₹4.1 L (14.8%) | L2 | Rejected-Finance Other than lowest quoted |
| 3 | L3₹33.2 L+₹5.2 L (18.5%)Rejected-Finance 85 D GHOSH PARA ROAD BARRAKPORE KOLKATA PIN 700120 | 24 PARAGANAS NORTH | WEST BENGAL | 700120 | ₹33.2 L+₹5.2 L (18.5%) | L3 | Rejected-Finance Other than lowest quoted |
| 4 | Rejected-Technical SHANTI KUNJ CHESIRE HOME ROAD BARIATU RANCHI 834009 JHARKHAND | RANCHI | JHARKHAND | 834009 | - | - | Rejected-Technical Wrong DD Submitted |
| 5 | Rejected-Technical GALI NO 4 GAUSHALA ROAD VIKASH NAGAR RAMGARH CANTT RAMGARH JHARKHAND 829122 | RAMGARH CANTT | RAMGARH | JHARKHAND | 829122 | - | - | Rejected-Technical Wrong DD Submitted |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
15 Jun 2024, 6:00 pmClosed
Shri Sahil Ratusaria, IDSE
Garrison Engineer Ranchi, 7th Club Road Ranchi, PIN-834001
REPAIR/ MAINT OF CONTROL PANEL FEEDER PILLAR BOX VOLTAGE STABLIZER UPS AND CONNECTED ACCESSORIES AT NAMKUM KHOJATOLI AREA UNDER GE RANCHI
2024_MES_655210_1
8400/1227/E8
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer Ranchi, 7th Club Road Ranchi, PI
Class D Cat b (I)
6 documents required · 6 mandatory
₹500
Yes
GE Ranchi
₹60,000
Yes
31 Aug 2024
21 May 2024
17 Jun 2024
22 May 2024
15 Jun 2024
3 Jun 2024
Amount
All as per item No.01 here-in-before but Main incoming MCCB 250 Amps and bus bar of rating 300 Amps and suitable Ampere meter with CTs and the size of busbar box minimum not less than 900 mm x 600mm x 450mm including 03 Nos cable glands for outgoing
All as per item No.02 here-in-before but Main incoming MCCB 125 Amps and bus bar of rating 200 Amps and suitable Ampere meter with CTs and the size of busbar box minimum not less than 900 mm x 600mm x 450mm including 03 Nos cable glands for outgoing .
Repair Maintenance of Servo Voltage stabilizers dry type 200 KVA any make with complete calibration of systems including all parameteras per manufacturere design servicing rectification of defect by replacing minor parts etc, and major parts shall be measured as supply only under items here in after item No 7 to 10. Relevant scheduled while servicing once in three months all as directed by Engr-in-charge. Note - Service report shall be submit to AGE E/M office for record.
Supply only the Carbon brush up to 200 K suitable for 200 kVA voltage stabilizer complete all as specified and directed.
Supply only the Servo motor suitable for 200 kVA voltage stabilizer complete all as specified and directed.
Supply only the Contactor /relay for cut off/tripping suitable for 200 kVA voltage stabilizer complete all as specified and directed.
Supply only the PCB Suitable for 200 KVA suitable for 200 kVA voltage stabilizer complete all as specified and directed.
Supply and fixing the Voltage stablizer of capaciy 5 KVA with input voltage 140V -160 and output voltage upto 280Volts digital display , high & low cutoff protection testing complete all as specified and directed. make -Volina/Mirotek/
Servicing to LT panels/Feeder pillar boxes comprising MCCBs/change over switches metering eqpt etc. as incomming/outgoing controls including cleaning, greasing the hinges, locking arrangement, checking the seviceability of individual items, identification of the defective parts replacing the wornout fastners, insulators, rubber door beadings, gakets etc all as directed Note:- (1) Unserviceable parts replaced if any shall be measured & paid seperately under respective items.
Removing the existing hinges by cutting and supply and fixing of new hinges all as per existing size
Painting of LT panel board/feeder pillar boxes with two coats of synthetic enamel spray paints over a coat of red oxide primer matching existing colour after scrapping the old paint by means of emery paper and cleaning with thinner including necessary markings/sign writing etc all as specified and directed
Rewiring the LT cubical type panel by means of PVC insulated multi strandard copper wire of existing size including replacing unserviceable connectors, fastners etc,etc after taking out the old unserviceable wiring all as specified and directed.
Supply only LED indication Lamps for R,Y,B Phase
Supply only Indoor resin cast ring type low tension current transformer 50/5A to 75/5A 15VA burden accuracy class 1 confirming to IS 2705 /1992
Supply only Indoor resin cast ring type low tension current transformer 100/5A to 300/5A 15VA burden accuracy class 1 confirming to IS 2705 /1992
M&L dismantling the cable connections of four pole/ three pole Air circuit breaker of capacity 630 A to 800 Amps ,415 V 50 HZ of Make : L&T/C&S/ABB make, strip opening the Air circuit breaker, inspecting the parts for serviceability/overhauling complete and carrying out the following repairs/maintenance :- a) Cleaning the insulation parts including bushings with CTC solution. b) Checking the alignment and condition of movable and stationary contacts and adjust them all as per manufacturer's instructional manual c) Check the bolts, nuts, washers, cotter pins and all terminal connections are in place and tights. d) Check arc chutes for damage and replace damaged parts. e) Clean and lubricate the operating mechanism with a light machine oil and bearings and with a non-hardening grease for the wearing surfaces. Adjust breaker operating mechanism all as per manufacturer's instructional manual. f) Checking / inspecting shunt trip coil for serviceability. g) Checking control device free for operation. j) Check after servicing the circuit breaker to verify the contacts move to the fully opened and fully closed positions, that there is an absence of friction and that the electrical operation is functional Note : The rate quoted deemed to be inclusive of T&P and minor spares like lubricants, nuts/bolts/washers/ pins etc. Major spares like contacts, shunt trip coil, relays, CTs etc will be measured & paid separately under relevant schedule items
Supply only CTs suitable for air circuit breakers of rating 630 Amps to 800 Amps as all per existing.
Supply only Lockable Trip Push Button (LTPB) suitable for air circuit breakers of rating rating 630 Amps to 800 Amps as all per existing.
Supply only Locking of ACB in Isolated position (LIP) suitable for air circuit breakers of rating 630 Amps to 800 Amps as all per existing.
Supply only Racking Interlock suitable for air circuit breakers of rating 630 Amps to 800 Amps as all per existing.
Supply only Door Interlock suitable for air circuit breakers of rating 630 Amps to 800 Amps as all per existing.
Supply only Vertical Terminal Adaptors suitable for air circuit breakers of rating 630 to 800 Amps rated all as per existing
Supply only Shunt Release suitable for air circuit breakers of rating 630 Amps to 800 Amps all as per existing.
Supply only Under Voltage Release suitable for air circuit breakers of rating 630 Amps to 800 Amps all as per existing.
Supply only Earth Fault Release suitable for air circuit breakers of rating 630 Amps to 800 Amps as all per existing.
Supply only Microprocessor based release suitable for air circuit breakers of rating 630 Amps to 800 Amps all as per existing.
Repair Maintenance of UPS 10 KVA any make with complete calibration of systems including all parameteras per manufacturere design servicing rectification of defect by replacing minor parts etc, and major parts shall be paid separately in respective items here in -after .Note Rate are included of transportation charges up and down to authorised service centre and required loading tools etc.
Supply only the rectifier suitable for 10 KVA UPS existing make testing complete all as specified and directed.
Supply only the inverter for 10 KVA UPS existing make testing complete all as specified and directed.
Supply only the static bypass switch suitable for for 10 KVA UPS existing make testing complete all as specified and directed.
Supply only the Battery suitable 12 Volts 26 AH suitable for 10 KVA UPS existing make testing complete all as directed.
Repair Maintenance of SMPS unit of capacity 150 Amp load with 415 volts +- 20% input voltage with out put 48 Volts Nominal any make with complete calibration of systems including all parameteras per manufacturere design servicing ,rectification of defect by replacing minor parts etc, and major parts shall be paid separately in respective items here in -after .Note - Rate are included of transportation charges up and down to authorised service centre /OEM Factory Kolkata and required loading tools etc.
Supply only the DC Meters for displaying charging voltage & Current forsuitable for SMPS unit of capacity 150 Amp load with 415 volts nput voltage with out put 48 Volts make testing complete all as directed.
Supply only the indication for Main ON, Charger On ,float ON, Boost ON,DC under voltage ,charging trip etc suitable for SMPS unit of capacity 150 Amp load with 415 volts input voltage with out put 48 Volts complete all as complete all as directed.
Spply only the three phase transformer double copper wound impregnant natural air cooled with Class E etc suitable for SMPS unit of capacity 150 Amp load with input voltage 415 volts and out put voltage 48 Volts complete all as complete all as directed.
S&F the Battery suitable 2.2 Volts 100 AH suitable for power bank of breaker testing complete all as directed.Make - Exide/Amaron/ Livsure
S&F the Battery charger 230V suitable for voltage range 12-144 Volts battery complete all as directed.Make - Hira/electron/Humuk
Supply and fixing sub-main wiring with two single core flame retardant PVC insulated and unsheathed cable with stranded copper conductor of 4 Sq mm drawing in & including medium grade PVC concealed conduit pipe 20 mm bore ISI marked with all accessories on walls and making good of disturbed surfaces including all conduit fittings, clamps, gutties etc and one additional earth wire of 4.0 Sq mm but green in colour for earth DBs and boxes with proper thimbles thimbles connecting up and taking down old submain wiring complete all as specified and directed,.(Note : Two run of wire and one run of earth wire drown in PVC conduit of 20 mm dia shall be measured as one RM).
Supply and fixing sub-main wiring with two single core flame retardant PVC insulated and unsheathed cable with stranded copper conductor of 6 Sq mm drawing in & including medium grade PVC concealed conduit pipe 20 mm bore ISI marked with all accessories on walls and making good of disturbed surfaces including all conduit fittings, clamps, gutties etc and one additional earth wire of 6.0 Sq mm but green in colour for earth DBs and boxes with proper thimbles thimbles connecting up and taking down old submain wiring complete all as specified and directed.(Note : Two run of wire and one run of earth wire drown in PVC conduit of 20 mm dia shall be measured as one RM).
Supply and fixing sub-main wiring with four single core flame retardant PVC insulated and unsheathed cable with stranded copper conductor of 10 Sq mm drawing in & including medium grade PVC concealed conduit pipe 32 mm bore ISI marked with all accessories on walls and making good of disturbed surfaces including all conduit fittings, clamps, gutties etc and one additional earth wire of 6.0 Sq mm but green in colour for earth DBs and boxes with proper thimbles thimbles connecting up and taking down old submain wiring complete all as specified and directed.(Note : four run of wire and one run of earth wire drown in PVC conduit of 20 mm dia shall be measured as one RM).
Supply and fixing in replacement of TPN Vertical Type Distribution Board, IP-43 protection, fitted with bus bars, neutral links, blanking plates (with out MCCB), 415 volts, 4 way double door type, grouted in wall in cement mortar 1:3 and making good of disturbed surface and matching with existing surface, complete all as specified and directed and including taking down old DBs and take to schedule of credit.Make- Legrand/Havells/Indo Asian (optipro).
Supply and fixing in replacement of MCCB, 4P, rated current 63 Amp, breaking capacity 16/18 kA thermal magnetic type and making electrical connection, complete all as specified and directed and including taking down old mccb and take to schedule of credit.Make- Legrand/Havells/Indo Asian (optipro).
Supply and fixing in replacement of MCCB, 4P, rated current 100 Amp, breaking capacity 16/18 kA thermal magnetic type and making electrical connection, complete all as specified and directed and including taking down old mccb and take to schedule of credit.Make- Legrand/Havells/Indo Asian (optipro).
M&L for Earth electrode 17.2 mm dia 3 mtr long of low carbon steel electrode with copper bonding of thickness 250 micron, Back-fill earthing enhancing compound Carbon based compound conductive concrete type which has a resistivity of less than 0.12 Ohm Mtr as per Clause 14.5D of IEEE : 80 standard. Back-fill compound should be electronically conductive (Like in metals) and should not depend on moisture for conduction. Back-fill comound should be environment friendly & should be solidify when mixed with water and set like concrete and should not leach / diffuse into the ground. Back-fill compound shall not be mixed with any soil while pouring in the bore hole. Test Certificate as per as per IEC: 62561-7 for Back-fill compound shall be submitted along with the material including SS clamp to be provode both side and PVC EARTH PIT 300 X 300 MM WITH PLASTIC LID complete all as specifiedNote - (i) Earth electrode should be applicable Standards IS: 3043, IEC 62561-2 & IEC 60364-5 and made of High Tensile steel rods copper bounded, High tensile strength,good electrical conduction & effective performance and suitable for all type of soil and provided minimum distance 3 Mtrs. (ii) Back-fill compound should be Compliance to the Standards IEEE: 80, IS-3043, BS 7430, IEC 62561-7, ANSI/NSF 60 Certification.(iii) Positive low resistance electrical connection to the earth. (iv) Does not contain hazardous chemicals.(v) Electronically conductive (like in metals) and is not dependent on moisture.(v) Provide the desire value of earth resistance as per required specified values. (vi) Provide the Exothermic welding joints to entire grid system joints of earthing electrod. (vii) Test certificated to be provide of each electrod.
S&F Earth continiuty conductor or main earthing lead fixed on wall on batten or recess or chases or buired in ground or drawn in conduit / pipe or fixed to wall up to test point / laying in below ground drown in GI tubing or any other indicated suituation for loop earthing etc, as required for 20x3 mm copper strip with proper saddles / spacer, screw.
Vp sanjiv
india trading company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .