Tender Value
₹12 L
EMD Value
₹24,000
Closing Date
11 Nov 2023, 6:00 pmClosed
CWE NAVY CHENNAI
Commander Works Engineers Navy Military Engineer Services Fort St George Rajaji Salai Chennai600 009
82576 PROVISION OF SPLIT AC AT COMNETCEN UNDER AGE(I) NAVY CHENNAI
2023_MES_623378_1
WE/NAVY/CHE/82576/E8 OF 2023-24
Open Tender
Miscellaneous Works
Item Rate
90 days
Chennai
As per NIT
8 documents required · 8 mandatory
₹500
AGE I Navy Chennai
₹24,000
Yes
29 Nov 2023
16 Oct 2023
13 Nov 2023
16 Oct 2023
11 Nov 2023
30 Oct 2023
16 Oct 2023 - 23 Oct 2023
Amount
SCHEDULE 'A' PART-I [ ELECTRICAL WORKS]
Supply ,install and testing split Air conditioner of 1.5 TR capacity inverter type 3 Star rating with indoor and outdoor units (copper condenser coil, copper cooling coil and evaporator including required length of copper tubing and cables for connecting indoor and outdoor units ) complete with cordless remote control unit , with inverter rotary compressor with inbuilt air ioniser and plazma filter for better indoor air quality complete ,complete all as specified and as directed. Make : VOLTAS / BLUESTAR /CARRIER/ O GENERAL/HITACHI. Note : Rate quoted is inclusive of the following:- (i) Drilling hole on the brick wall to facilitate routing of Copper pipe, drain pipe and cable from indoor unit to outdoor unit. (ii) Sealing the hole from outside ,after installation, with white cement. (iii) Pressure testing , cooling performance check and product demonstation. (iv) cable for connecting indoor and outdoor unit upto 3.00 Mtr each. (v) Material and labour for fixing Remote stand in wall. (vi) Copper pipe, upto 3.00 Mtr each.
Supply ,install and testing split Air conditioner of 2 TR capacity inverter type 3 Star rating with indoor and outdoor units (copper condenser coil, copper cooling coil and evaporator including required length of copper tubing and cables for connecting indoor and outdoor units ) complete with cordless remote control unit , with inverter rotary compressor with inbuilt air ioniser and plazma filter for better indoor air quality complete ,complete all as specified and as directed. Make : VOLTAS / BLUESTAR /CARRIER/ O GENERAL/HITACHI. Note : Rate quoted is inclusive of the following:- (i) Drilling hole on the brick wall to facilitate routing of Copper pipe, drain pipe and cable from indoor unit to outdoor unit. (ii) Sealing the hole from outside ,after installation, with white cement. (iii) Pressure testing , cooling performance check and product demonstation. (iv) cable for connecting indoor and outdoor unit upto 3.00 Mtr each. (v) Material and labour for fixing Remote stand in wall. (vi) Copper pipe, upto 3.00 Mtr each.
Supply & fixing of PVC drain pipe of 15mm size flexible type of including clamp ets complete all as specified and directed.
Supply and fixing Copper pipe 1/2" dia with foam insulation including connecting, including taking down old unserviceable pipe and deposite to MES store yard,complete all as specified and directed.
Supply and fixing Copper pipe 1/4" dia with foam insulation including connecting, including taking down old unserviceable pipe and deposite to MES store yard, complete all as specified and directed.
Supply & fixing of three core flexible cord copper wire of size 4 Sqmm complete all as specified and directed.
Supply and fixing of GI powder coated brackets , for fixing of split AC's including grouting with suitable size fastners complete all as specified and directed.
M & L for single pole and neutral (SPN) sheet metal enclosure with a two pin and earth plug and socket complet with one single pole MCB 240 V, 20 amp complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for sub main wiring (concealed) complete with two single core 4 Sqmm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through in and including 20 mm dia rigid non-metallic PVC conduit heavy grade and conduit accessories including 4 Sqmm FRLS PVC insulated unsheathed stranded copper earth cable connected to common earth dolly complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface all as specified and directed. Note: 2 run of 4 sqmm,1 run of 4 sqmm & one run of PVC conduit shall be measured as single unit
Supply and Fix sheet metal enclosures powder coated double door DB's, TPN, 4 way IP-43, with 200amps rated busbar including taking down the old unserviceable DB and deposite to MES store yard, complete all as specified and as directed.
Supply and fix MCCBs 63 Amps, 415V,16KA, TPN 50HZ including making necessary incoming and outgoing electrical connection with suitable size of copper lugs complete all as specified and as directed.
Supply and Fix MCB SP 10-32 amps with 10KA breaking capacity B curve confirming to IS/IEC 60898-1 2002 integrated label holder sliding bottom clamp IP 20 protected terminal sliding shutter 240v 50HZ including making necessary incoming and outgoing electrical connection with suitable size of copper lugs complete all as specified and as directed.
G.L.THIRUMALAI NAIDU AND COMPANY
Banyan Engineers and Contractors
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .