Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.6 LAccepted-Finance LANE NO 05 HNO 56 SHIV VIHAR TALAB TILLO JAMMU | ₹6.6 L | L1 | Accepted-Finance Being L1 |
| 2 | L2₹6.8 LRejected-Finance NEAR SURAJ ICE FACTORY TALAB TILLO JAMMU | ₹6.8 L | L2 | Rejected-Finance Being L2 |
| 3 | L3₹7.0 LRejected-Finance LANE NO 5 HNO 560 SHAM VIHAR TALAB TILLO JAMMU | ₹7.0 L | L3 | Rejected-Finance Being L3 |
Tender Value
Refer Docs
EMD Value
₹15,128
Closing Date
25 Mar 2026, 2:00 pmClosed
Executive Engineer
Executive Engineer University works department
Construction of Souvenir and coffee shop G plus 1 at New University campus Electrical work
2026_UDJK_305478_1
enit 170 dated 25-2-26
Open Tender
Electrical Works
240 days
University of Jammu
Please refer Tender documents.
2 documents required · 2 mandatory
₹708
Executive Engineer University works department
₹15,128
2 Apr 2026
6 Mar 2026
27 Mar 2026
6 Mar 2026
25 Mar 2026
6 Mar 2026
Wiring for light point/fan point/ceiling fan point/exhaust fan point/call bell point with 1.5 Sq. mm FRLS PVC insulated, copper conductor cable in surface/recessed medium class PVC conduit, with modular type switch,modular plate and earthing the point with 1.5 sq mm. FRLS PVC insulated copper conductor single core cable etc. as required. (Wire Make ISI Marked Havells/Anchor /HPL /KEI/Polycab Conduit Make - ISI Marked Anchor/High Power /AKG/Equivalent make of required specification to be approved by the Engineer In charge (Group ‘B’)
Supplying and fixing of following sizes of medium class PVC conduit along with the accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required- ISI Marked Anchor/High Power /AKG/) Equivalent make of required specification to be approved by the Engineer In charge 25 mm dia
Supplying and fixing 5 Amp to 32 amps rating, 240/415 volts, 10 KA C curve miniature circuit breaker of Single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required. i. Single pole (Make Havells /Anchor/ C&S/HPL/ Equivalent make of required specification to be approved by the Engineer In charge)
Wiring for circuit/sub-main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. (Wire Make ISI Marked Havells/Anchor/KEI/polycab Equivalent make of required specification to be approved by the Engineer In charge ) i. 2x1.5 +1x1.5 Sq mm
ii. 2x2.5+ 1x2.5 Sq mm
ii. 4x6+ 2x6 Sq mm
iv. 4x10+ 2x6 Sq mm
Supply and Fixing following ratings, double pole, 240 volts, isolator in the existing MCB DB Complete with connections, testing and commissioning etc. as reqd. 63 Amp ratings (Make Havells /Anchor/ C&S/HPL/ Equivalent make of required specification to be approved by the Engineer In charge)
c.63 Amp 415 volt Four Pole Isolator.
Supply and fixing of following size/module, GI box along with modular base and cover plate for modular switches in recess etc. as reqd A.12 Module
B.6 Module
C. 3 Module
D. 1 or 2 Module
Supply & fixing 16 amp Modular type switch on the existing switch box or cover including connection as required. (Make: Anchor/Havells /HPL/Sanchi major)
Supply & fixing 6 pin 15/16 amp Modular type socket outlet on the existing switch box or cover including connection as required (Make: Havells/ Anchor/Sanchi major
Supply & fixing 5/6 amp Modular type switch on the existing switch box or cover including connection as required (Make :Havells/ Anchor /Sanchi major)
Supply & fixing 3 pin 5/6 amp Modular type socket outlet on the existing switch box or cover including connection as required(Make: Havells/ Anchor /Sanchi major/)
Earthing with Copper earth plate 600mm x 600mm x 3mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/coke and salt as required.
Providing and fixing 4mm dia copper wire on surface or in recess for loop earthing as required.
Supplying and fixing following way, horizontal type three pole and neutral,sheet steel,MCB distribution board,415 V,on surface/recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB/RCCB/Isolators) ( Havells/Anchor /I.A /HPL Equivalent make of required specification to be approved by the Engineer In charge) i. 6 way(4+18), Double door
Supplying and drawing of following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required (Wire Make ISI Marked Havells/HPL/Anchor/KEI/Polycab/ Equivalent make of required specification to be approved by the Engineer In charge) i 1x1.5 sqmm
ii.2x6 sqmm
Supply and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts washers etc as reqd.
Erection of ACSR conductor of 7/2.11 mm to 7/3.00 mm diameter including binding etc. as required.
Erection of metallic pole of following length in cement concrete 1:3:6 ( 1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling and secured with holding clamps, bolts, nuts etc. as required. a. Above 8 meter upto 11 meter.
Supply & fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. (Make Havells/ Anchor /Major Equivalent make of required specification to be approved by the Engineer In charge)
Supplying and fixing brass batten/Angle holder including connection etc. as required. (Make Havells/ HPL / Anchor / Sanchi Major Equivalent make of required specification to be approved by the Engineer In charge)
Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Make Anchor /Havells /HPL Equivalent make of required specification to be approved by the Engineer In charge) i. 100 AMP 16kA TP MCCB
ii. 200 AMP 25kA TPMCCB
Supply &Installation of following type of surface mounted/recessed mounted decorative Indoor Linear energy saving , energy efficient LED Lumainiers complete with connection testing and commissioning. Make (Halonix/ Havells/Bajaj/HPL/Compact) Equivalent make of required specification to be approved by the Engineer In charge) 4 feet long 18 to 22 watt ,230 volts LED batten type tube light fitting complete .
2 feet 9 to 12 watt ,230 volts LED batten type tube light fitting complete
Recess LED Panel 595X595 36 W Recess mounted fixture difuser with minimum system lumen efficiency of 110W and minimum 3900 lumen with CRCA constant current driver for proper driving Led and P.f is 0.9 with THD 10%, CRI 80. The Led with life of 50k Hrs The Fixture should have minimum surge voltage of 3kV. Make (Halonix/ Havells/Bajaj/HPL/Compact) Equivalent make of required specification to be approved by the Engineer In charge)
18 Watt LED recessed/surface mounting 6500 K, 240 Volts as per cat : Slim Panel down light fittings/luminaries square or round (225x225)mm to (300x300)mm Dimensions.
Design, manufacture, testing at works & supply, installation, testing & commissioning cubicle panel floor mounted (on base frame) totally enclosed and extensible type . The general construction shall comprise to IS 8623-93. The design shall include all provisions for safety of operating and maintenance personal. IP 42 for indoor and IP54 for outdoor, shall be compartmentalized type having space and arrangements for I/C. cable/bus ducting/incoming switch gears, bus couplers, insulated and properly supported compartmentalized switch gear, outgoing compartmentalized switch gear, bus bar support and terminations, interconnection between bus bars & switch gear with auxiliary bus bars/ insulated conductors/strips etc. (Make Electric Field/ Bharti Engineers/Gupta & Friends/ Jai maa/KED)Main Outdoor Building Control Panel MAIN NORMAL a. INCOMING Space for 1 No.200A TP MCCB for power load/light/A.C load. OUTGOING Space for 2 No. 100A TP MCCB for power load/light Load Dimensions 3'0"x3’0"x1’6”
Supply/installation of the following type of outdoor decorative energy efficient LED flood light and Street lights luminaries complete with all accessories connection testing and commissioning as required. Make (Bajaj/Surya /Havells/ C&S/ HPL /compact/ Halonix) 100 watt,230 volts IP 66/IP65.
Supply, testing and commissioning and Laying of PVC sheathed Aluminum conductor 1100 volts graded PVC AA Armoured/unarmoured XLPE Cable including end termination, crimping, cost of thimbles, nuts bolts, glands, connection, testing and commissioning complete job. (Make: Havells / General/Polycab / Gloster) Equivalent make of required specification to be approved by the Engineer In charge) 2 core 16 sq mm armoured cable
3 ½ core 35 sq mm armoured cable
Supply, installation, testing, commissioning of 1200 mm sweep ceiling fans complete with blades BEE 3 to 5 star rated energy efficient .(Make: Havells /Anchor/USHA /Crompton) Equivalent make of required specification to be approved by the Engineer In charge)
Supply, installation, testing, commissioning of 300 mm sweep BEE 1 to 3 star rated energy efficient exhaust fan. Make: ( Anchor/Havellls/Bajaj/Crompton Equivalent make of required specification to be approved by the Engineer In charge)
Supply of swaged type steel tubular pole of following height duly painted with two coats of red oxide and two coats of silver paint made of Mild Steel conforming to IS 2713 part III of 1980 designated as 410 SP 30 HT 9 mtr planted in 1.5 m deep pole pit to be dug for the purpose, welded with (300x300x6) mm base plate at bottom including filling back the pit with cement concrete excavation 1:3:6 (1 cement: 3 corse sand:6 graded stone aggregate 40 mm nomial size) (excluding the cost of CC). The planting depth of the pole shall be 1/6 th 0f pole a) 9 mtr height.
Supply of following size ACSR conductor of required aluminum and steel strands including binding etc. as required as per IS O 398 part 2 a) 7/2.11 mm to 7/4mm
Supply, fabrication of following sizes of channels, angles and flat iron including drilling holes for insulators and painting with primer and silver paint. A)Channel (75x40x6)mm
….do…. Angle (50x50x6)mm
….do…. Flat iron clamps suitable for LT/HT poles (50x6)mm.
Supply, laying amd Testing of 3-core 11 KV graded HT XLPE insulated inner sheath of PVC, Galvanised steel flat strip or round/ Armoured (U.E) cable confirming to IS 7089Part-2.2011 with upto date amendments (Havells/polycab/gloster/General Equivalent make of required specification to be approved by the Engineer In charge) 120 sqmm 3 core
S/F of 32mm dia G.I pipe for flood light bracket including bending to shape, (40x3)mm flat iron clamp and wiring with 1.5 sqmm PVC insulated wire complete wire complete as reqd.
Providing/fixing 32 to 40 amp rating , 230 volts SPN MCB in the existing MCB DB or enclose complete with connection testing and commissing complete Job. (Havells/Anchor/HPL make Equivalent make of required specification to be approved by the Engineer In charge)
Supplying and fixing following ways horizontal type MCB Distribution Board 240V on surface including powder painted earthing etc. as required (But without MCB/RCCB/Isolators. i.4 way, DD For A.C Havells/Anchor /I.A /HPL/ Equivalent make of required specification to be approved by the Engineer In charge
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.10 MB
BOQ_992193.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid