| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25 LAccepted-AOC | ₹25 L Quoted ₹26.1 L | L1 | Accepted-AOC Accepted being L1 bidder. |
| 2 | L2₹27.0 LRejected-Finance | ₹27.0 L | L2 | Rejected-Finance Rejected being other L1 bidder |
| 3 | L3₹27.8 LRejected-Finance | ₹27.8 L | L3 | Rejected-Finance Rejected being other L1 bidder |
| 4 | L4₹27.8 LRejected-Finance | ₹27.8 L | L4 | Rejected-Finance Rejected being other L1 bidder |
| 5 | L5₹29.2 LRejected-Finance AZAD COLONY B 90 FEET ROAD SOURA SRINAGAR J K 190011 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190011 | ₹29.2 L | L5 | Rejected-Finance Rejected being other L1 bidder |
| Sl No | Description | Qty | Unit | M/S SHABIR AHMAD SHAH AND CO L3 | M/S ABBAS M. ENTERPRISES L4 | M/S BASHIR AHMAD AND SONS L6 | FG CONSTRUCTION L5 | M/S MARSHAL TRADERS L10 | M/S GEE EMM MIR L1 | M/S BALI AGENCIES L2 | M/s Gh Qadir and Sons L7 | VEDA INFRASTRUCTURE L9 | BHAT CONTRACTORS AND GENERAL ORDER SUPPLIERS L8 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L for Earthing complete with Copper earth plate 600 x 600 x 3.15 mm thick buried directly in ground (earth pit not less that 2.25mtr deep below ground level ) with top edge of the plate not less than 1.5mr below normal ground level connected to 20x3 mm Cu strip as earthing lead by means of brazing after tighten by bolts, nuts, check nuts and washers from earth pit to test point with protection GI pipe of size 50mm dia light grade and providing masonry enclosure including watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 20 mm GI pipe light grade for earth strip protection complete with earth pit pit covers of 300mmx 300 mm made of cast iron including painting as per color coding as per IS,in PCC 1:2:4 type B0 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work in any type of soil, returning filling in and removal of surplus soil complete all as specified, complete as specifed and directed.
Note: (i) Copper strip 7.5 mtr included in the quoted rate from earth pit to test point (ii) Contractor should ensure that result of each earthing is less than 2 Ohm and in case soil is not suitable for the same is to be placed suitable clay soil to bring the desired result. Contractor shall qute rates after site visit accordingly. (iii) On testing after completion if the desired resistance is not obtained the contractor shall redo the earthing without any extra cost to department. (iv) Work includes brazing work for earth strip. (v) Work includes brazing of Cu strip to copper earth electrode. | 36 | Each Job | 11,500 ₹4.1 L | 14,000 ₹5.0 L | 16,000 ₹5.8 L | 13,500 ₹4.9 L | 31,000 ₹11.2 L | 7,000 ₹2.5 L | 8,900 ₹3.2 L | 12,500 ₹4.5 L | 20,700 ₹7.5 L | 17,000 ₹6.1 L |
| 2.00 | M&L for Earthing complete with GI earth plate 600 x 600 x 6 mm thick buried directly in ground (earth pit not less that 2.25mtr deep below ground level ) with top edge of the plate not less than 1.5 m below normal ground level connected to 32X6mm GI strip as earthing lead by means of brazing after tighten by bolts, nuts, check nuts and washers from earth pit to test point with protection GI pipe of size 50 mm dia light grade and providing masonry enclosure including watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 20 mm GI pipe light grade for earth strip protection complete with earth pit in PCC 1:2:4 type B0 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work in any type of soil, returning filling in and removal of surplus soil complete all as specified and as directed.
Note: GI strip 7.5 mtr included in the quoted rate from earth pit to test point | 75 | Each | 5,200 ₹3.9 L | 3,800 ₹2.9 L | 4,500 ₹3.4 L | 5,000 ₹3.8 L | 4,800 ₹3.6 L | 4,000 ₹3 L | 4,800 ₹3.6 L | 5,500 ₹4.1 L | 7,500 ₹5.6 L | 22,000 ₹16.5 L |
| 3.00 | M&L for Earthing complete with GI earth plate 600 x 600 x 6 mm thick buried directly in ground (earth pit not less that 2.25mtr deep below ground level ) with top edge of the plate not less than 1.5 m below normal ground level connected to 25X4 mm GI strip as earthing lead by means of brazing after tighten by bolts, nuts, check nuts and washers from earth pit to test point with protection GI pipe of size 50mm dia light grade and providing masonry enclosure including watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 20 mm GI pipe light grade for earth strip protection complete with earth pit in PCC 1:2:4 type B0 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work in any type of soil, returning filling in and removal of surplus soil complete all as specified and as directed.
Note: GI strip 7.5 mtr included in the quoted rate from earth pit to test point | 80 | Each | 5,300 ₹4.2 L | 4,000 ₹3.2 L | 4,500 ₹3.6 L | 4,500 ₹3.6 L | 4,800 ₹3.8 L | 4,000 ₹3.2 L | 4,800 ₹3.8 L | 5,500 ₹4.4 L | 7,000 ₹5.6 L | 5,000 ₹4 L |
| 4.00 | M&L for brazing in repair work for GI strip not exceeding 3.2 cm in length and not exceeding 6 mm in thickness complete all as specified. | 400 | Each job | 125 ₹50,000 | 200 ₹80,000 | 50 ₹20,000 | 100 ₹40,000 | 200 ₹80,000 | 90 ₹36,000 | 200 ₹80,000 | 300 ₹1.2 L | 50 ₹20,000 | 50 ₹20,000 |
| 5.00 | M&L for brazing in repair work for copper strip not exceeding 3.2 cm in length and not exceeding 6 mm in thickness complete all as specified. | 300 | Each job | 150 ₹45,000 | 300 ₹90,000 | 50 ₹15,000 | 150 ₹45,000 | 230 ₹69,000 | 149 ₹44,700 | 180.08 ₹54,023.46 | 300 ₹90,000 | 50 ₹15,000 | 100 ₹30,000 |
| 6.00 | S&F in replacement of saddle/insulator for strip with fixing arrangement in roof/wall of building having configuration upto G+5 for run of strips on it complete all as specified and directed. | 500 | Each | 50 ₹25,000 | 25 ₹12,500 | 50 ₹25,000 | 25 ₹12,500 | 75 ₹37,500 | 50 ₹25,000 | 42.65 ₹21,325.05 | 100 ₹50,000 | 100 ₹50,000 | 50 ₹25,000 |
| 7.00 | Refixing only of strip (serviceable strips as obtained from taking down) of any type & size but including saddles/insulators with screws for fixing complete all as specified. | 900 | RM | 20 ₹18,000 | 10 ₹9,000 | 5 ₹4,500 | 5 ₹4,500 | 90 ₹81,000 | 10 ₹9,000 | 18.96 ₹17,060.04 | 50 ₹45,000 | 5 ₹4,500 | 10 ₹9,000 |
| 8.00 | S&F aluminium strip 25x3.15 mm with saddles/insulators, complete with fixing screws for roof/down conductors/main earthing lead, including bracing/jointing and nut bolts jointing at all joints complete all as specified. | 300 | RM | 100 ₹30,000 | 90 ₹27,000 | 60 ₹18,000 | 65 ₹19,500 | 300 ₹90,000 | 149 ₹44,700 | 80.56 ₹24,168.39 | 100 ₹30,000 | 100 ₹30,000 | 50 ₹15,000 |
| 9.00 | S&F copper strip 32 x 6 mm earthing lead laid in trenches/GI pipe for making grid/loop of earthing pit complete all as required at site all as specified and directed by Engr-in-charge. | 400 | RM | 450 ₹1.8 L | 500 ₹2 L | 1,100 ₹4.4 L | 750 ₹3 L | 2,500 ₹10 L | 649 ₹2.6 L | 500 ₹2 L | 700 ₹2.8 L | 900 ₹3.6 L | 300 ₹1.2 L |
| 10.00 | S&F copper strip 20x3.15 mm with saddles/insulators, complete with fixing screws for roof/down conductors/main earthing lead, including bracing and nut bolts jointing at all joints complete all as specified. | 500 | RM | 250 ₹1.3 L | 250 ₹1.3 L | 300 ₹1.5 L | 390 ₹1.9 L | 1,250 ₹6.3 L | 549 ₹2.7 L | 210 ₹1.1 L | 450 ₹2.3 L | 600 ₹3 L | 200 ₹1 L |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
8 Oct 2025, 6:00 pmClosed
GE (AF) AWANTIPUR
GE (AF) AWANTIPUR, C/O 8 FBSU, AF STN AWANTIPUR
REPAIR/ MAINT OF EARTHING INFRASTRUCTURE AND OTHER CONNECTED ITEMS OF TECH INFRA AT AF STN AWANTIPUR
2025_MES_730274_1
GE (AF) AWA-55/2025-26
Open Tender
Electrical and Maintenance Works
180 days
GE (AF) AWANTIPUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (AF) AWANTIPUR
₹90,000
20 Apr 2026
10 Sept 2025
10 Oct 2025
10 Sept 2025
8 Oct 2025
24 Sept 2025
Amount
M&L for brazing in repair work for GI strip not exceeding 3.2 cm in length and not exceeding 6 mm in thickness complete all as specified.
M&L for brazing in repair work for copper strip not exceeding 3.2 cm in length and not exceeding 6 mm in thickness complete all as specified.
S&F in replacement of saddle/insulator for strip with fixing arrangement in roof/wall of building having configuration upto G+5 for run of strips on it complete all as specified and directed.
Refixing only of strip (serviceable strips as obtained from taking down) of any type & size but including saddles/insulators with screws for fixing complete all as specified.
S&F aluminium strip 25x3.15 mm with saddles/insulators, complete with fixing screws for roof/down conductors/main earthing lead, including bracing/jointing and nut bolts jointing at all joints complete all as specified.
S&F copper strip 32 x 6 mm earthing lead laid in trenches/GI pipe for making grid/loop of earthing pit complete all as required at site all as specified and directed by Engr-in-charge.
S&F copper strip 20x3.15 mm with saddles/insulators, complete with fixing screws for roof/down conductors/main earthing lead, including bracing and nut bolts jointing at all joints complete all as specified.
S&F galvanized iron strip 25x4 mm with saddles/insulators, complete with fixing screws for roof/down conductors/main earthing lead, including bracing/welding and nut bolts jointing at all joints complete all as specified.
M&L for brazing in repair work for aluminum strip not exceeding 3.2 cm in length and not exceeding 6 mm in thickness complete all as specified.
Taking down the existing aluminium/copper/GI strip of any size and type from the top of blast pens/ground/equipment/bldg (roof/down conductor) and keeping in shape custody (for serviceable strips to re-use ) complete all as specified and directed.
M&L for Test point terminal block for earthing made of gun metal or phosphorus bronze size 75x75x25mm driled and srewed including 3 nos 8mm dia 25mm long hex head srew,complete as specified and directed.
Taking down Old material retrieved from copper/chemical/ GI earthing any type and size.
M&L for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI wire 4 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth (Plate) electrode at one end and connected to main switch board /panel/ test point at the other including watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 20 mm GI pipe light grade for earth strip protection complete with earth pit in PCC 1:2:4 type B0 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work in any type of soil, returning filling in and removal of surplus soil complete all as specified.
S & F Air terminal single pointed aluminum rod 12mm dia and 300mm long including taking down old u/s air termination rod of any type all as specified and as directed.
Supply and laying GI pipe light grade with all fittings for protection of earthing conductor laid in trenches or fixing to wall with suitable size of FI clamp complete of 40 mm bore dia including taking down old pipe etc
- do - but of 20mm bore as in protection for GI Earth wire or for watering arrangement all as specified and as directed by Engineer In Charge
S & F Marking Earthing Pit with white/ coloured Hylam sheet/per pex sheet 3mm thick of size 200x150 mm fixed with MS angle iron 20X20X4 mm and .75 mtr long lncluding painting with synthetic eneamelled paints 2 coats over a coat of red oxide primer fixed by means of 2 nos nuts,bolts,washer of suitable size and grout the maker nearer to the earth pit with PCC 1:2:4 of size 0.15 x 0.15x 0.15 m including necessary earth work.Maker shall be written the following letters (letter of size 25 mm)
EARTH PIT NO : EQUIPMENT/BUILDING CONNECTED : DATE OF TEST : EARTH RESISTANCE IN OHMS :
Supply & fix 15mm nominal bore tubes, medium grade galvanised with all fittings fixed on walls,ceiling,laid in floors or burried under the ground for filling of water in earthing pit including inserting suitable size of tee with outgoing water deilvery pipe line from PVC over head tank to earthing pit complete all as specified and as directed by Engr-in-charge.
Note:- An amount of Rs. 1,08,700.00 on account of Credit Schedule for Sch 'A' Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum.
M/S BALI AGENCIES (BID ID -3440074)
M/S SHABIR AHMAD SHAH AND CO (BID ID -3439905)
M/S ABBAS M. ENTERPRISES (BID ID -3440425)
FG CONSTRUCTION (BID ID -3445859)
M/S BASHIR AHMAD AND SONS (BID ID -3443303)
M/s Gh Qadir and Sons (BID ID -3439856)
BHAT CONTRACTORS AND GENERAL ORDER SUPPLIERS (BID ID -3445662)
VEDA INFRASTRUCTURE (BID ID -3445965)
M/S MARSHAL TRADERS (BID ID -3446017)
stage.html
html • 0.07 MB
technical_817567.pdf
techsummary_817567.pdf
finance_817567.pdf
BOQ Comparative Chart
xlsx
finsummary_817567.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.26 MB
BOQ_817567.xls
BOQ • 0.29 MB
tender55.pdf
Tender Documents • 1.64 MB
Download all tender documents and submit your bid