Tender Value
₹2.8 L
EMD Value
₹5,600
Closing Date
1 Sept 2026, 9:30 amClosed
EE(Elect.)/ONZ
EE(Elect.)/ONZ Division
Provision of 1 Nos. Semi High Mast Pole with LED lights near Jat Dharamshala in Ward No. 34 Nangloi in AC-08 under Narela Zone.
2026_MCD_288812_1
EE/Elect/ONZ/2026-27/TC/17
Open Tender
Electrical Works
Percentage
90 days
Outer North Zone
Please refer Tender documents.
3 documents required · 3 mandatory
₹590
₹5,600
1 Sept 2026
24 Aug 2026
1 Sept 2026
24 Aug 2026
1 Sept 2026
24 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Earthing with GI earth pipe 4.5Mx40mm dia i/c accessories and providing masnary enclosure with cover plate having locking arrangement and watering pipe etc(but without charcoal or coke and salt complete) as required. | - | Each | 5,958 | - |
| 2 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) | 4 | Metre | 160 | ₹640 |
| 3 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. | - | Metre | 287 | - |
| 4 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm | 82 | Metre | 47 | ₹3,854 |
| 5 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. Mm | 12 | Metre | 36 | ₹432 |
| 6 | Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required. | 2 | Each | 2,783 | ₹5,566 |
| 7 | Providing and laying in position cement concrete 1:3:6 (1cement : 2 coarse sand : 6 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required. | 1.5 | cum | - | - |
| 8 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.(a) 63 mm dia (OD-63 mm & ID-51 mm nominal) | 10 | Metre | 289 | ₹2,890 |
| 9 | LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy >135lm/Watt) Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%,Input voltage: Input voltage: 140-270 Volt AC,frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI>70, under voltage and over voltage rotection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).(a) 100 Watt | - | Each | 2,567 | - |
| 10 | Providing and laying i/c HDPE pipe of 40 mm outer dia with PN 4 rating by hand moling / mannual method confirming to IS 4984. | 66 | Metre | 592 | ₹39,072 |
stage.html
html • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
Tendernotice_2.pdf
PDF • 33.81 MB
BOQ_336857.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .