SPL REP TO ROOF TREATMENT CHAJJA PLASTER FALSE CEILING TILING PAINTING AND ELECTRIC FITTINGS OF BLDG NO P 1850 OF HQ JOSA OTHER SANCTIONED WORKS IN ARMY AREA UNDER GE ARMY CENTRAL
2022_MES_563046_1
GE/J/A OF 2022-23
Open Tender
Civil Works
Item Rate
180 days
JODHPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE ARMY CENTRAL
₹97,000
Yes
22 Dec 2022
14 Nov 2022
14 Dec 2022
14 Nov 2022
12 Dec 2022
29 Nov 2022
Amount
B/R ITEMS Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 15 cm thickness (below or above ground level) and removal unserviceable materials, debris and rubbish to a distance out side MD land complete all as specified and directed.
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) in any description and in any position not otherwise specifically provided for and removal unserviceable materials, debris and rubbish to a distance out side MD land complete all as specified and directed.
M&L for 25 mm thick plain cement concrete 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) as in sub base of flooring, including finishing the surface even & rough to receive tiling etc., complete all as specified and directed.
M&L for dark shade ultracharged Vitrified Ceramic tiles, 10 mm thick (square/ rectagular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, (size & shape, shade and pattern as approved by GE), as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match shade of tiles, over & including M&L 15 mm thick screed bed in cement mortar 1:6, complete all as specified and directed.
All as per item No. 4.00 here-in-above, but as in skirting over & including M&L 10 mm thick backing coat in cement motar 1:4, complete all as specified and directed. Make : Somany/ Kajaria/ Johnson as approved by GE.
M&L for non skid ceramic colour tiles (premium quality) of size 400 mm x 400 mm x 6-7 mm, (size & shape, shade and pattern as approved by GE),as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match shade of tiles, over & including M&L 15 mm thick screed bed in cement mortar 1:6, complete all as specified and directed.
M&L for glazed colour ceramic tiles (premium quality) of size 300X450X6-7 mm, as in vertical surface such as i.e. dado/skirting etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, over & including M&L 10mm thick backing coat in CM (1:4) complete all as specified and directed.
Removing existing roof treatment and preparing surfaces to the entire satisfaction of Engr-in Charge /GE including taking down existing plaster, padding,cleaning of all foreign material such as grass roots dust etc and roughening the concrete surfaces by wire brushes and washing down to remove dust etc . flushing at junction of parapets complete and removing the same to the places where directed by Engr-in-Charge
Taking down carefully cement concrete /spalled out concrete from RCC roof projections, ceiling ,sunsheds, beams, etc upto cover depth by chipping out lightly including necessary scafolding etc, complete all as specified and directed.
M&L for plain cement concrete 1:2:4, type B-0 (using 12.50mm graded crushed stone aggregate), as in roof padding over roof for making good depression / undulation to make the existing as filling in depression of roof slab, complete all as specified & directed.
M&L for neat cement slurry @ 3.00 kg/Sqm and screeding / bedding layer of 10 mm thick in CM 1:3 mixed with water proofing compound as per manufacturer instructions over the RCC roof slab for laying of water proofing treatment including providing the following as roof treatment complete all as specified and as directed : - (a) FIRST COURSE: Applying a coat of bituminous primer @ 0.4 litre / Sqm manufactured by the same agency that of APP with a density 0.87 to 0.89 Kg/litre at 25 degree celsius on prepared plastered surfaces. (b) SECOND COURSE: Applying one coat of bonding material using blown type bitumen conforming to IS-702 grade 85/25 @ 1.20 Kg/Sqm (c) THIRD COURSE : Provide a layer of APP modified polymeric membrane centre core of 100mm micron HMHDPE, outer film 20 micron each, thickness 3.00mm having weight not less than 3.00 Kg/Sqm using torch application method with minimum 10cm side lap and 15cm end lap complete . (d) FOURTH COURSE : Applying one coat of bonding material using blown type bitumen conforming to IS- 702 grade 85/25 @ 1.20 Kg/Sqm. (e) FOURTH COURSE : 40 mm thick plain cement concrete 1:2:4 (using 20 mm stone crushed aggregate) as in roof padding NOTE :- 1. A Information Tablet will be put up in the front side wall of the buildings where this work will be done. All building/structure shall be provided with plaque (tablet) furnishing the information as per PS clause, in plaster engraving in and painted as directed by GE 2.WPC shall be measured and paid separately under respective item.
Supply only integral water proofing compound ISI Marked all as specified.
Taking down cement plaster on stone masonry RCC surfaces, dado surfaces etc complete including racking out joints, hacking for key scrubbing down with water, complete all as specified and directed.
Taking down cement plaster, any description on ceiling etc including racking out joints, hacking for key, scrubbing down with water etc including removing rubbish to out side MD land complete all as specified and directed.
Rendering 15 mm thick in cement mortar 1:6 on stone masonry surfaces finished even and smooth with out using extra cement including mixing with water proofing compound ( WPC) as per manufacturer instructions complete all as specified and directed. Note :- WPC will be measured and paid separately as supply only.
Rendering 10mm thick in cement mortar 1:3 on concrete ceiling surfaces / sunsheds / facia / RCC chajja, finished even and smooth without using extra cement, complete all as specified and directed. Note -Rate are deemed to be included for scaffolding, trestles, ladders, cradles, etc. necessary for execution of work and protective measures.
Racking out joints/ pointing to random rubble or polygonal rubble un-coursed or brought up to courses masonry built in cement mortar or cement lime mortar, coursed or un-coursed in walls not less than 12mm deep, washing the joints, removing rubbish off the premises and keeping the surface to pointed or plastered wet for two days prior to re-pointing or plastering complete all as specified & directed.
M&L keyed pointing in cement mortar (1:3) to squared rubble masonry regular coursed or un coursed complete all as specified & directed.
M&L PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregate for plate form for water tank on roof, slightly rounded edges as directed, including demolition of old u/s concrete, complete all as specified & directed.
S&F in replacement rotational moulded polythene water storage tanks of 500 ltrs capacity, white three layered (ISI marked) (Cylinderically vertical with closed top) hoisted and fixed in postion all as specified in SSR Part-I with PTMT ball valve heigh pressure with epoxy coated aluminium rod and high density plastic ball suitable for 20mm bore pipe weight not less than 210gms including dismantling old tanks, complete all as specified and directed.
All as per item No. 20.00 here-in-above, but of size 1000 Ltrs capacity complete all as specified and directed.
Preparation of newly plastered surface of walls and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces, complete all as specified and directed. Note -i)- Rate are deemed to be included for scaffolding, trestles, ladders, cradles, etc. necessary for execution of work and protective measures. ii)- Paint shall be in one or more colours/ shades all as approved by GE.
Complete removal of existing treatment of wall & preparation of old decorative / painted surface of walls and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces, complete all as specified and directed. Note -Rate are deemed to be included for scaffolding, trestles, ladders, cradles, etc. necessary for execution of work and protective measures.
M&L for preparation of old white washed surfaces and applying two coats of white wash on wall surfaces complete all as specified and directed.
M&L for preparation of old white washed surfaces and applying two coats of white wash on ceiling surfaces complete all as specified and directed.
Complete removal of existing treatment of walls and applying two coats of cement base paint on wall surface over one coat of primer including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces complete complete all as specified and as directed . Note -Rate are deemed to be included for scaffolding, trestles, ladders, cradles, etc. necessary for execution of work and protective measures.
M&L for preparing new plastered or unplastered surfaces and applying 2 mm thick wall care putty including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of oil bound distemper on walls, complete all as specified and directed. Note -i)- Rate are deemed to be included for scaffolding, trestles, ladders, cradles, etc. necessary for execution of work and protective measures. ii)- OBD shall be in one or more colours/ shades all as approved by GE.
All as per item No. 27.00 here-in-above, but apply on ceiling, complete all as specified and directed.
Complete removal of existing treatment of ceiling and applying 2 mm thick wall care putty including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of oil bound distemper on ceilings, complete all as specified and directed. Note -i)- Rate are deemed to be included for scaffolding, trestles, ladders, cradles, etc. necessary for execution of work and protective measures. ii)- OBD shall be in one or more colours/ shades all as approved by GE.
M&L for preparing new plastered or unplastered surfaces and applying 2 mm thick wall care putty including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of plastic inetrior emulsion paint on walls, complete all as specified and directed. Note -i)- Rate are deemed to be included for scaffolding, trestles, ladders, cradles, etc. necessary for execution of work and protective measures. ii)- Plastic emulsion paint shall be in one or more colours/ shades all as approved by GE.
M&L for GI frame work for seamless ceiling comprising of GI perimeter chanel 0.55mm thick with two unequal flanges of 20 & 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm c/c intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm c/c with GI cleat and steel expansion fasteners with and including ceiling section (not exceeding 1.2M length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to intermediate channel at 457mm c/c and hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slab by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and including M&L for applying 02 mm thick plaster of paris over and including S&F gypsum board 12mm thick in ceiling fixed with screws as per manufacturers instructions over the frame work and preparation of ceiling board and applying two coats of oil bound distemper over a coat of wall / ceiling care putty including dismantling of existing false ceiling of any thickness with cover fillets complete all as specified and as directed.
M&L for preparation of old painted wood and wood based surfaces of any description otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed .
M&L for preparation of old painted wood and wood based surfaces of any description otherwise described, over 10cm width or girth and applying two coat of synthetic enamel paint complete all as specified and as directed .
S&F GI chicken wire mesh of 0.71 mm dia wire & 12 mm mesh size fixed with nails & screws around RCC chajjas/fascias etc., complete all as specified and directed.
M&L 50 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate laid in alternative bays as in plinth protection including finishing the surface even & fair & filling the joints with mastic filling i.e one part of bitumen 85/25 and 3 parts of sand by weight in 2 mtr interval, complete all as specified and directed.
M&L 75 mm thick PCC 1:4:8 type D2 using 40mm graded crushed stone aggregate, as in sub base of floor/hard standing, incld. compaction properly & universal and laid to level, complete all as specified and directed by Engineer-in-charge.
Supply and laying machine pressed / factory made chamfered edge cement concrete rubberised interlocking paver block, 60mm thick with 6 mm thick top layers of anti abrasive material of M-35 grade with any colour, design & pattern, & size/ shape, as approved by GE as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness made by table vibratory method using PU mould, laid in required colour & pattern over and including M&L 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, complete all as specified and directed.
Supply and laying machine / factory made kerb stone of M-25 grade,at or near ground level, cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required, complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint on new concrete surfaces of any description over 10 cm width or girth, over & including M&L a coat of primer including preparation of surfaces, complete all as specified and directed.
M&L for preparation of old painted steel surfaces of any description not other wise described over 10 cm width or girth and applying two coat of synthetic enamel paint complete all as specified and directed.
M&L for machine pressed precast chequered cement concrete tiles any shape, 28 to30 mm thick with 6 mm thick top layers of anti abrasive material, with white cement and pigments, set, jointed and pointed in neat cement slurry as in floors/ path etc over and including 15 mm thick screed bed in CM 1:4 including dismantling old unserviceable tiles complete all as specified and directed.
S&F in replacement of 75 mm bore PVC (SWR) pipes single socketed in any length Type 'B' (ISI Marked) with rubber ring joints fixed to walls with MS clamps of suitable size complete all as specified and as directed .
S&F in replacement of 100 mm bore PVC (SWR) pipes single socketed in any length Type 'B' (ISI Marked) with rubber ring joints fixed to walls with MS clamps of suitable size complete all as specified and as directed .
S&F 110 mm bore (SWR) PVC bends any radius with oval access door complete all as specified and directed.
S& F 110 mm bore PVC [SWR] branch piece, single (single Y) equal or unequal complete all as specified and directed.
M&L for sand stone slabs, 5 cm thick, Jodhpur pattern/colour in sun-shades, chajjas, shelves, cills, landings, cover stones, templates, etc not exceeding 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in cement mortar 1:4 complete all as specified and directed.
M&L powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-Charge.
S&F for tinted glass 5.5mm thick, fixed to aluminium frame with rubber beading, exceeding 0.5 Sq.m in each pane complete all as specified and directed.
M&L for treating the surface with beeswax polish, complete all as specified and directed.
M&L for solid PVC wall lining consisting of 5mm thick plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per manufacturer specifications, including dismantling of old u/s existing wall lining, complete all as specified and directed.
Taking down of steel window and ventilators, complete all as specified and directed.
S&F factory made box type windows (steel) (BWM) with side hung shutter including cooler opening as shown in Drg No CEJZ/TD/20 sheet1/3 to 3/3 complete with glazing bars, dovetailed or welded, complete all as specified and as directed by Engr-in-Charge. Note : Both shutter (wherever applicable) will be jointed internally with flat iron of size 40 x 4mm and quoted rate deemed to include the cost component of the same.
S&F of box type steel ventilator with top hung shutter including hinges with steel handle, and steel peg stay, complete without glazing bars, complete all as specified and directed.
S&F of aluminium alloy anodised sliding door bolt with hasp and staple bolt type and fixings clips of sheet cast or extruded sections and fixings bolts and sliding bolts of extruded sections and fixed 16mm dia and 200mm long, complete all as specified and directed.
S&F of aluminium anodized,tower bolt extruded section of size 200 mm long, complete all as specified and directed.
S&F aluminum anodised handle extruded section of size 150mm long, complete all as specified and directed.
S&F 150 mm size double action spring hinge bright finished body of brass, with phosphor bronze wire spring, bright polished all as per the sample of complete all as spd & directed.
Taking down chowkhats or frame with shutters (without taking of shutters from the frames) area exc 1.5 Sqm but not exceeding 4 Sqm each, complete all as directed.
M&L for 15-18mm thick machine cut Udaipur green marble, (size & shape, shade and pattern as approved by GE) as in cooking platform over & including M&L 10mm thick screed bed in cement mortar (1:4) and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including polishing and rounding the edges, complete all as specified and directed..
M&L of 20-25 mm thick machine cut KOTA stone slab as in shelves (Single piece) fixed in walls machine cut, laid over cement and jointed with grey cement slurry with pigment to match the shade of the slab, including rubbing and Mirror polishing, complete all as specified and as directed.
M&L for 25 mm thick (telephone black shade) granite stone or sink, as in cooking plateform, jambs, steps, pillars, wash basin counter top oval type, & similar work, machine cut, mirror polished best quality as per sample, over & including M&L 15 mm thick screeding in CM1:4 including rounding of the edges & providing suitable dia hole in the slab for the gas pipe, complete all as specified and directed.
M&L 25-30 mm thick precast cement concrete 1:3:6 type C1 (using 12.50 mm stone crushed aggregate) as in kangaroose , width 30 cm with intricate design on one side all as per sample, including two coat cement base paint, complete all as per specified and directed by Engg.-in-charge.
S&F 35mm thick precast cement concrete 1:2:4 type B-0 (using12.5mm graded crushed stone aggregate, (measured solid), as in louvers and jallies including all moulding, excluding frame, set in CM 1:4, complete all as specified and directed.
S&F precast cement concrete 1:2:4 Type B-1 (using 20mm graded aggregate) as in post of size 100mmx100mmx75cm, fixed in CM 1:4 with grooves for fixing of RCC jali, complete all as specified and directed.
Demolition of stone / boulder masonry walling, built in cement mortar including all quoins, arches, pillars etc and removal unserviceable materials, debris, rubbish to out side MD land complete all as specified and directed.
M&L precast cement concrete block masonry using PCC 1:2:4, type B-1 solid blocks, 10 cm thick and setting in cement mortar 1:4, straight or curved on plan exceeding 6 m mean radius complete all as specified and directed.
S&F in replacement of PVC door seal, including taking down old u/s door seal, complete all as per specified & directed by Engg.-in-charge.
Demolition of cement concrete (unreinforced) in any description and roof padding of WPT including removing bituminious sheet, paving not exc 20 cm thickness and removal unserviceable materials, debris and rubbish to a distance out side MD land complete all as specified and directed.
Disconnecting existing tanks setting aside [or lowering if required] for repairs,cleaning etc., and hoisting if required reconnecting, including Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, and refixing in position of water tanks of capacity exceeding 500 litres and not exceeding 1000 litres complete all as specified and directed.
Rendering 15 mm thick in cement mortar 1:4 on stone masonry surfaces finished fair and even with out using extra cement including mixing with water proofing compound ( WPC) as per manufacturer instructions complete all as specified and directed. Note :- WPC will be measured and paid separately as supply only.
M&L for preparing new plastered or unplastered surfaces and applying 2 mm thick of wall care putty including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of plastic acrylic emulsion paint on walls, complete all as specified and directed. Note -i)- Rate are deemed to be included for scaffolding, trestles, ladders, cradles, etc. necessary for execution of work and protective measures. ii)- Plastic emulsion paint shall be in one or more colours/ shades all as approved by GE.
Complete removal of existing treatment of wall & preparation of old decorative / painted surface of walls and applying 2 mm thick of wall care putty including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of plastic acrylic emulsion paint on walls, complete all as specified and directed. Note -i)- Rate are deemed to be included for scaffolding, trestles, ladders, cradles, etc. necessary for execution of work and protective measures. ii)- Plastic emulsion paint shall be in one or more colours/ shades all as approved by GE.
Surface excavation not exceeding 30cm and averaging 15 cm deep and getting out in soft / loose soil complete all as specified and directed.
Excavating in post holes or similar holes each not exc 0.50 cu.m, getting out in any type of soil, returning,fillig in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm and removing srplus soil soil to a distance not exc. 50 m, complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified and as directed .
M&L for squared rubble walling, Jodhpur type, regular coursed, well bonded ,bedded and solidly hearted built in cement mortar 1:6, complete all as specified and directed.
M&L plain cement concrete 1:3:6 type C-2 by using 40 mm graded crushed stone aggregate as in foundation, filling and mass concrete, concrete block for iron strut or post complete all as specified and as directed .
S&F steel work in tubular trusses including special shaped washers etc complete using ERW or induction butt welded tubes confirming to IS:1161-1979 Grade St-240 complete all as specified and directed.
S&F rolled mild steel roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., complete all as specified and directed.
S&F rolled mild steel work confirming to Fe 410-W, Grade-E- 250, Quality-A as in plates [plain & chequered], channels, angles, square cut or notched [ordinary or counter sunk] forming holes without any attachment complete all as specified and directed.
M&L for preparation of new or previously untreated steel surface of any description, over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red- oxide, zinc chrome primer complete all as specified and directed.
M&L Prepainted galvalume aluminium zinc coating GI based corrugated steel sheeting 0.50 mm thick any colour having tensile strenght 550Mpa in roof coverings fixed with self tapping screws, complete all as specified and as directed by Engr-in-Charge.
Removing excavated soil to a distance not exceeding 50 mtr and depositing where directed at a level n. exc. 1.50 mtr above the starting point complete all as specified and as directed.
M&L plain cement concrete (1:4:8) type D-2 using 40 mm graded crushed stone aggregate as in foundation, filling and mass concrete complete all as specified & directed by Engineer-in-charge.
M&L for hard core broken stone of gauge not exc. 63mm, deposited, spread and levelled in layers not exc. 15cm thick, water and rammed to a true surface, with power roller, complete all as specified and as directed by Engr-in-Charge.
M&L 40 mm thick PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in flooring/hard standing laid in alternative bays using glass dividing strips, complete all as specified and directed.
Supply only 38mm wide and 3mm thick glass dividing strip complete all as specified & directed by Engineer-in-charge.
M&L plain cement concrete (1:2:4) type B-1using 20mm graded crushed stone aggregate as in roof kerbs or mud steps as chamfered on edge in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed, rounded or chamfered on edge, fixing of holdfast etc complete all as specified & directed.
S & F in repairs 1.00mm thick Steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type complete all as specified and directed.
S&F Sheet glass 3mm thick, ordinary quality and glazing with oil putty in squares not exceeding 0.5 Sq.m in each pane complete all as specified and directed.
Preparation of new plastered or unplastered surfaces and applying three coats of white wash on ceiling surfaces complete all as specified and directed.
Taking up or down 25mm bore steel tubing and connections including cleaning for refixing or credited to contractor complete all as specified and directed.
All as per item No. 92.00 here-in-above, but size 20 mm bore
All as per item No. 92.00 here-in-above, but size 15 mm bore
Refixing old GI water tubing of 25 mm bore, medium grade and including S&F all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing complete all as specified and directed.
All as per item No. 95.00 here-in-above, but size 20 mm bore
All as per item No. 95.00 here-in-above, but size 15 mm bore
S&F of water GI tubing medium grade, galvanized, with all fittings fixed to wall, ceilings or laid n floors, complete all as specified and directed. (a) 25 mm bore,
-Ditto- All as per Item No. 98 above but 20 mm bore.
-Ditto- All as per Item No. 98 above but 15 mm bore including cutting chases, pinning in & making good to disturbed portion to match the existing surface etc., complete all as specified and directed.
E/M ITEMS Taking down carefully aluminium/copper point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendent, regulators, sockets, bell push, bell, light fittings etc. removing serviceable materials to store for keeping in safe custody for reuse at site or for taking credit (Credit shall be made as per Schedule of credit), removing rubbish from the site and making good all disturbed surfaces of walls, floors etc. to match to the existing surfaces, complete all as directed.
M&L modular point wiring using approved colour coding (Red , Black and Green for single phase circuits) as per IS code -694 with valid CML No., with multi stranded copper conductor 1.5 sq mm nominal cross-sectional area, single core, PVC insulated and sheathed FRLSH cable 1100 Volts grade, ISI marked, in and including heavy duty non metallic PVC rigid conduit of 25mm dia with accessories concealed in wall/roof/floor etc, ISI marked with1.6mm thick mild steel/ prestressed steel sunken / concealed box (with earth dolly) duly painted two coats of anti corrosive paint/aluminium paint over a coat of red oxide primer internally and two coats of black bituminous paint over a coat of red oxide primer externally, with 1 module modular cover plate(ISI Marked) cover for fixing of switches, sockets and fan regulators etc, inciuding PVC insulated & sheathed multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly for One light/fan/bell point controlled by one, one way switch, complete all as specified and directed.
All as per serial Item No.102.00 above but for one 3 pin socket outlet 5/6 Amps on the same board with other switches complete all as specified and directed.
All as per serial Item No.102.00 above but for one 3 pin socket outlet 5/6 Amps on the independent board, complete all as specified and directed.
All as per serial Item No.102.00 above but for 16 Amps 3 pin socket point on independent board with 2.50 Sqmm PVC insulated FRLSH multi-stranded copper conductor with 2.50 Sqmm PVC insulated & FRLSH multi-stranded copper conductor as earth wire complete all as specified and directed .
All as per serial Item No.102.00 above but for 16 Amps 3 pin socket point on independent board with 4.00 Sqmm PVC insulated FRLSH multi-stranded copper conductor with 4.00 Sqmm PVC insulated & FRLSH multi-stranded copper conductor as earth wire complete all as specified and directed .
S&F modular switch, one way, 6 Amps, 1 module, complete all as specified and directed.
S&F modular switch, one way, 16 Amps, 1 module, complete all as specified and directed.
S&F modular socket outlet, 2/3 Pin, combined 2 module, 6 Amps, complete all as specified and directed.
S&F modular socket outlet, 6 Pin, combined 2 module, 16 Amps, complete all as specified and directed.
S&F modular bell push 6 Amp, 1 module, complete all as specified and directed.
S&F bell electric multi music type type 230 volts single pole, complete all as specified and as directed.
S&F modular fan step regulator, 120W, 2 module, hume free and connecting electrically, complete all as specified and as directed by Engr-in-Charge.
S&F lamp holder insulated body polycarbonate type with back plate, including 9W LED lamp complete all as specified and as directed by Engr-in-Charge.
M&L ceiling rose, 3 phase / PVC / Polycarbonate, isolated body, ISI Marked, complete all as specified and as directed.
Supply and fixing LED lights fitting 1x 20W/22W, 4 feet, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, as in repairs, including taking down old u/s material complete all as specified and directed.
S&F LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed.
S&F LED light fitting 1X9W / 1X10W bulk head luminaries, with lamp holders including 9 W LED bulb including taking down old fitting complete all as specified and as directed
S&F bldg security LED Light Luminaire of 35 Watts having IP 65/66 protection fiting made out of pressure die cast Aluminium housing, operating Voltage 140-270 Volts with in built surge protectore, toughened glass with and including GI pipe 32mm dia bracket of 1.5 m in length including drilling holes, nuts & bolts 2 coats of red oxide primer on GI pipe and fixing with wall security light on building wall connecting cable, complete all as specified and directed.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size, complete all as specified and directed.
Supply and fixing round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed.
S&F decorative wall mounting, brushed nickel finish fixture with opal glass diffuser suitable with 9W LED Lamp B22 base all as specified and directed.
S&F decorative gate light, high grade unbreakable polycarbonate material suitable with 20W LED Lamp B22 base all as specified and directed.
S&F 25 watt LED strip light with driver, ISI Marked, complete all as specified and directed by Engg.-in-charge.
S&F in replacement of ceiling fans with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep, min air delivery 210 CFM with service value 6.00 BEE, 5 star rated with brushless direct current motor (BLDC) connecting up with and including three core flexible PVC insulated multi stranded copper condutor of size 1.0 sqmm from ceiling rose/ conector to fan (earth wire to connected to fan hook), ISI marked, including taking down old u/s ceiling fan, complete all as per directed and specifed
S&F in replacement of exhaust fan, heavy duty steel body, AC single phase 300 mm sweep complete with louvers including cutting / making holes in wall fixing/grouting of frame & connecting with & including 3 core PVC insulated copper conductor flexible cable of size 23/0.0076 (or eq. Size in mm) from ceiling rose to fan, including taking down old u/s exhaust fan, complete all as specified and as directed.
S&F exhaust fan, made of sturdy Engineering plastic body, complete with louvers shutter, 250 mm sweep, 1200 RPM, 230 V 50 Hz, AC single phase, complete with louvers including fixing/grouting of frame & connecting with & including 3 core PVC insulated copper conductor flexible cable of size 23/0.0076 (or eq. Size in mm) from ceiling rose to fan & making opening, including taking down old u/s exhaust fan complete all as specified and directed.
Supply and fixing single pole neutral enclosure with two pin and earth plug and socket modular type complete with one single pole MCB 20 Amps, complete all as specified and directed.
S&F and testing factory made sheet metal enclosure for MCB DB SPN 8 way 240 volt with double door, IP - 43 protection duly fixed/concealed in wall complete and making good disturbed surfaces of wall, floor etc including necessary connection lugging with copper lugs pin/ring type, complete all as specified and as directed.
S&F and testing factory made sheet metal enclosure for MCB DB SPN 12 way 240 volt with double door, IP - 43 protection duly fixed/concealed in wall complete and making good disturbed surfaces of wall, floor etc including necessary connection lugging with copper lugs pin/ring type, complete all as specified and as directed.
S&F and testing factory made sheet metal enclosure for MCB DB TPN 4 way 415 volt with double door, IP - 43 protection duly fixed/concealed in wall complete and making good disturbed surfaces of wall, floor etc including necessary connection lugging with copper lugs pin/ring type, complete all as specified and as directed.
Supply, fixing, testing and commissioning TPN 63 Amps 415V 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection, complete all as specified and as directed.
Supply, fixing, testing and commissioning SPN 40 Amps 240V 10KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection, complete all as specified and as directed.
Supply, fixing, testing and commissioning SPN 63 Amps 240V 10KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection, complete all as specified and as directed.
Supply, fixing, testing and commissioning SP 6 to 32 Amps 240V 10KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection, complete all as specified and as directed.
S&F for in replacement sub main wiring with two runs of PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade of size 6 Sqmm and one run of 6 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH cable (Phase-Red, Neutral-Black, Earth-Green) 1100 volt grade as earth lead drawn through in and including non metallic PVC conduit of size 25 mm dia (external) with wall thickness not less than 1.8 mm, (ISI marked) concealed in wall including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc., complete all as specified and as directed. NOTE: Two runs of 6.00 Sqmm cable with one run of 6.00 Sqmm earth wire and PVC conduit shall be measured & paid for as one length.
S&F for in replacement sub main wiring with two runs of PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade of size 4 Sqmm and one run of 4 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH cable (Phase-Red, Neutral-Black, Earth-Green) 1100 volt grade as earth lead drawn through in and including non metallic PVC conduit of size 25 mm dia (external) with wall thickness not less than 1.8 mm, (ISI marked) concealed in wall including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc., complete all as specified and as directed. NOTE: Two runs of 4.00 Sqmm cable with one run of 4.00 Sqmm earth wire and PVC conduit shall be measured & paid for as one length.
Supply,testing and installation of electric storage geyser of capacity 25 Ltrs, BEE 5 star rating, 230Volts, AC, 50Hz, comprising of heating element 2000 watt,puff insulation,both power indicating LED lamp and heating indicating LED lamp neccasry suitable 3 core copper cable,suitable plug top, inlcluding supply and fixing of inlet and out let connection to geyser with steel grip,chromium plated PVC connection of 600mm in length - 02 Nos (one for inlet GI pipe and other one for outlet connection) suitable to connect inlet GI pipe 15mm dia and out let GI pipe 15mm dia (out let PVC connection should be capable to withstand the designed temparature of Geyser) and geyser shall be fixed on wall surface with wall mount bracket and 10 cm anchor bolts as required inclduing all necessary plumbling works and civil works complete all as directed and as specified.
Taking down unserviceable electric geyser any type, applying two coats painting and refixing in same position by suitable size of fasteners, complete all as directed.
Taking down carefully electric meter any type and capacity and depositing in MES store yard and refixing in same position, complete all as directed.
Supply, laying, jointing, testing and commissioning 1100 volt grade heavy duty XLPE insulated LT under ground cable, sheathed, as per IS- 7098 (Part I) 1988, galvanized steel strip armoured heavy duty multi stranded aluminum conductor laid in trenches / passed through pipe/duct road crossing, fixed on poles/ wall with clamps made out of mild steel flat iron including fixing accessories like brass cable glands double compression type, lugs, nuts, bolts, washers etc of size 4 core 25 sqmm, including taking down old u/s cable from duct/trench/pipes/pole/wall etc. with protection pipe, PCC cable cover & etc., complete all as specified and directed Note: - (i) Excavation and earthwork, sand cushioning, PCC cable cover, shall be measured and paid separately in relevant item here in after .
M&L for earthing complete with galvanised steel earth plate electrode 60 x60cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in elevtrical plate no. 3 connected to Earthing test point all as specified or indicated including testing on completion Note : (i) Rates are deemed to be included for necessry earth work ,PCC pit , RCC cover etc complete. (ii) Earth lead shall be up to 7.5 Mtr and rates are deemed to be included for GI pipe 15mm Light grade upto 7.5 mtrs for protection of earth wire 4.0 mm dia, complete all as specified and as directed.
M&L for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised strip of size 25 x 4mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion, complete all as specified and as directed. Note:- (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead.
M&L for dry clean fine river sand as in sand cushioning to underground cable including punning down of sand layer, complete all as specified and as directed. Note :- Punned thickness shall only be measured and paid.
Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1, flat, size 250x150mm x40 mm, complete all as specified and directed.
M&L for galvanised steel tubing, light grade, for protection of cable, laid in trenches/road crossing/floor or fixed to pole/wall with all fittings, of size 40 mm bore, complete all as specified and directed.
S&F for in replacement sub main wiring with four runs of PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade of size 10 Sqmm and one run of 10 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH cable (Phase-Red, Neutral-Black, Earth-Green) 1100 volt grade as earth lead drawn through in and including non metallic PVC conduit of size 25 mm dia (external) with wall thickness not less than 1.8 mm, (ISI marked) concealed in wall including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc., complete all as specified and as directed. NOTE: Five runs of 10.00 Sqmm cable with one run of 6.00 Sqmm earth wire and PVC conduit shall be measured & paid for as one length.
M&L for checking out of split type AC 1.50/2 TR capacity indoor unit in any position & location of army area Jodhpur, including necessary servicing i.e. electrical connection wiring, cleaning condensor, blower fan motor, servicing including replacement of micro filter of approved quality and testing for proper functioning of split AC type air conditioner all as directed by Engg.-in-charge. Note: - (1) The rate quoted by the contractor shall be inclusive of maintaining record of machine with capacity, location, obtain signature of user after satisfactory completion of servcing duly verified by concerned JE/AGE. 2)- Greasing / oiling of blower fan motor including charging of Gas will measured and paid seperately.
Taking down Indoor Unit and out door unit safely and disconnect copper tube (suction and discharge line ) and relocate new position with proper fastening and drilling suitable hole on wall with proper finish and connect outdoor unit with suitable size of suction and discharge line and refill gas as per existing and connect properly via soldering and MISC work etc including pressureing the complete unit with suitable Gas as per specified and as directed
M&L for nylon insulation on discharge and suction pipe of split AC in existing location and position, all as directed.
M&L in replacement for copper dischagre tube of size 3/8" duly nylon insulated in existing location and position, all as directed.
M&L in replacement for copper suction tube of size 5/8" duly nylon insulated in existing location and position, all as directed.
Supply only refrigerant gas M-404/444/R22, in existing location and position, all as directed. Note:- Gas to be supplied in cylinder duly sealed by manufacturer/ factory sealed with proper PV's & other docs or specifications
Supply, install, commission and testing factory made weather proof powder coated cubical type LT panel board made out of CRCA sheet of 3.15mm thick ,outdoor canopy type, CPRI approved ,conform to IS-8623, IP-54 class protection, floor mounted, dust and vermin proof,front and rear operated door, mounted on MS angle iron frame work of size 50X50x6mm ,with necessary locking arrangement and duly painted with two coats of powder coated paint of approved shade after seven tank treatment process both internally and externally and fixed 0.5m above ground level and 0.3m grouted in ground / floor including necessary excavation/ earth work in any type of soil, foundation PCC 1:4:8 type D2 and the panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be complete with suitable capacity of Aluminium bus bar 300Amp TPN with suitable size of PVC insulated copper conductor, thimbles glands including taking down old panel board complete all as specified and directed with the following accessories :- In coming : (a) MCCB 4Pole, 125 Amps, 25KA -01 No (b) Digital amperemeter 0 to 800 amps -01 No (c) Digital voltmeter 0 to 500 V - 01 No. (d) Phase indicator lamp (RYB) (set of three) - 01 Set Out going :- (a) CHANGE OVER 100 Amps 10 KA -01 No (b) MCB TPN 63 Amps 10 KA -03 No (e) MCB SPN 63 Amps 10 KA -03 No (f) Blanking space for accommodate electric meter 01 Nos
S&F 6 Sqmm copper conductor 3 core PVC insulated sheated wire 1100 V grade, complete all as specified & directed .
Note:- (i) All items in BOQ are for "Materials and labour / Supply and fix" and to be executed in "Repairs/Replacement unless otherwise specifically mentioned as "Supply only" or Fixing only" in BOQ Bidders are required to quote their rates accordingly. (ii) The contract sum shall be arrived at after duducting amount of schedule of "Credit" from the Total quoted amount (iii) Makes of materials will be approved by GE in writing before commencement of work. (iv)- Quantities are clubbed in BOQ for different Jobs. For which ref. Annexure-I on Sl. page. No. 45 (R), 46 to 47 of tender document.
M/S KAUTILYA GARG
SNEH CORPORATION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .