Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical GANDIPUR PRANPATTI JAUNPUR | JAUNPUR | JAUNPUR | UTTAR PRADESH | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹15 L
EMD Value
₹15,000
Closing Date
28 Feb 2024, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
S.E., EUDC-IX, LESA TRANS GOMTI-2 LUCKNOW
33/11 KV S/S HAL POWER HOUSE FAIZABAD ROAD LUCKNOW
On Site Preventive maintenance of Distribution T/F 160, 250 , 400, 630 to 1000 KVA installed at various site under 33/11 KV Sub-Stations in the Jurisdiction of EUDD-Indira Nagar, LESA Trans Gomti, Lucknow.
2024_MVVNL_904663_1
85/EUDC-IX/2023-24
Open Tender
Electrical Works
Item Rate
365 days
33/11 KV S/S HAL POWER HOUSE FAIZABAD ROAD LUCKNOW
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
A/C No. 77290200000745 IFSC Code BARB0VJRSMN
₹15,000
Yes
4 Mar 2024
24 Feb 2024
28 Feb 2024
24 Feb 2024
28 Feb 2024
24 Feb 2024
Amount
Removing Top Cover Plate by opening of Bolt and nuts of T/F and other internal connection of T/F required for repairing safely and reconnect it after appropriately after Minor repairing work of Medium Power Distribution Transformer(l l/O.4 KV) installed at various site for Stopping Oil leakage from T/F, Replacement of Damaged H.T/LT Bushing Rod and other work as per site requirement & site conditions. Firm has to make arrangement for draining and refilling of T/F Oil , if required for carrying out the work. (Distance of 20 Km. from concerned store)
160, 250 KVA, 400 KVA T/F
630 KVA and 1000 KVA T/F
Toping Up/Filling of Reclaimed T/F Oil in T/F's
T/F Oil in following capacity of T/F's up to 2/3rd level of conservator Tank for Distribution T/F having less Oil as per Indent placed for repairing by JE/SDO. Filling up of these T/F by Reclaimed T/F Oil upto required level and carriage of reclaimed T/F Oil, T/F drums from concerned store/site including safe loading and unloading at both ends. Complete in all respect as per site requirement( Reclaimed T/F Oil will be provided by the concerned JE(D) ( Required Vehicle & suitable Container for storage of Reclaimed T/F Oil will be arranged by the Contractor at his own cost.)
Replacement of Old and Damaged H.T Busihing rod including Oil Seal/Gaskits etc. ( 160, 250, 400, 630 and 1000 KVA T/F)
Removal of Old and damaged H.T Busing Rod from T/F and fixing of suitable size new H.T Busing rod made of Brass with all nuts and bolts etc. including replacement of all old/damaged Neoprene Oil seal/Gasket set by fixing suitable size New Neoprene Oil Seal/Gasket Set & as per site requirement, Complete Job in all respect. (All material will be provided by the Contractor)
Replacement of Old and Damaged L.T Bushing rod including Oil Seal/Gaskits etc. Removal of Old and damaged L.T Busing Rod from T/F and fixing of suitable size new L.T
Busing rod made of Brass with all nuts and bolts etc. including replacement of all old/damaged Neoprene Oil seal/Gasket set by fixing suitable size New Neoprene Oil Seal/Gasket Set & as per site requirement, Complete Job in all respect. ( All material will be provided by the contractor)
Stopping Oil leakage from T/F H.T/LT Bushing side.
Stopping of Oil leakage from T/F L.T/H.T Side Bushing. Removing of all damaged oil Seal/Gasket Set/Cork sheet and fixing of suitable size new Neoprene Oil seal/Gasket set/Cork sheet and tightening of H.T/LT bushing rod Complete Job in all respect. ( All material will be provided by the contractor)
Replacement of Old and Damaged LT PVC CABLE (All Material will be provided by Department)
Replace LT Aluminum unarmored XLPE/PVC Cable 3.5x400 Sq.mm
Replace LT Aluminum unarmored XLPE/PVC Cable 1X240/400 Sq.mm
Replacement of Old and Damaged Suitable capacity of Aluminum Lugs (All Material will be provided by Contractor).
fixing of suitable capacity of lugs after removing old and damaged lugs from various capacity of PVC cable with using crimping tools.
Maintenance Repairing Of Damage T/F Plinth
Plinth by Using Bricks ,ballast or sand and Cement. (All Material will be provided by Contactor.
SIDDHI ENTERPRISES
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .