Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 CrAdmitted-Finance | ₹1.8 Cr | L1 | Admitted-Finance |
| 2 | L2₹2.1 Cr+₹22.8 L (12.5%)Admitted-Finance | ₹2.1 Cr+₹22.8 L (12.5%) | L2 | Admitted-Finance |
| 3 | Rejected-Technical PLOT NO 170 ZONE II M P NAGAR BHOPAL M P 462011 | BHOPAL | BHOPAL | MADHYA PRADESH | 462011 | - | - | Rejected-Technical Bidder has been rejected due to non adherence to the technical specifications as per tender conditions |
| 4 | Rejected-Technical | - | - | Rejected-Technical Bidder has been rejected due to non adherence to the technical specifications as per tender conditions |
| 5 | Rejected-Technical 331 TOWER A SPAZE I TECH PARK SECTOR 49 SOHNA ROAD GURGAON 122002 | GURGAON | GURGAON | HARYANA | 122002 | - | - | Rejected-Technical Bidder has been rejected due to non adherence to the technical specifications as per tender conditions |
| Sl No | Description | Qty | Unit | EVAC ENGINEERING PROJECTS PVT. LTD. L2 | B M Associates L1 |
|---|---|---|---|---|---|
| 1.00Part A | |||||
| 2.00OUTDOOR UNIT | |||||
| 3.00Supply, installation, testing & commissioning of fully factory assembled Variable Refrigerant Volume type multi unit air-conditioning system inverter type complete with indoor and outdoor units with individual controller for cooling only operations. SITC of Variable Refrigerant Volume/Flow Outdoor Unit complete with hermitically sealed scroll compressor as per following nominal capacities complete with protective coated fins, mounting frame, casing, microproccessor panel, and other standard accessories : i) Microproccessor panel , ii) First charge of refirigerant R 410A or R407C , iii) Protective coated fins iv) Mounting frame with isolation pad , all required accessories, structural support and civil foundation. v) Interconnecting Pipes for Liquid, Discharge and Suction vi) Interconnecting Cables and Earthing from nearest given point, vii) Accumulator, viii) Specific Oil return system All Inverter Scroll Compressor(s) with variable refrigeration evaporating temperature enabled feature in outdoor unit capable of inverter control with 6 pole compressor motor. The inverter compressor should be capable of changing the speed in accordance to the variation in cooling or heating load requirement, back pressure control mechanism for efficient operation in low-load condition. The outdoor unit should be fitted with low noise, aero spiral design fan with minimum External Static Pressure of 75 Pa for easy discharge of Hot air, aero fitting grille, to reduce pressure loss. The outdoor unit should be capable of automatic refrigerant charge function. The heat exchanger shall be constructed with copper tubes mechanically bonded to aluminium fins to form a cross fin coil. The cost should be inclusive of Lifting, Shifting & Positioning of Outdoor Units to the installation platform | |||||
| 3.01 | Outdoor condensing Unit ( 60 HP) Nominal capacity | 4 | Nos | 15,81,108 ₹63,24,432 | 12,09,323 ₹48,37,292 Lowest |
| 4.00Indoor Units- All with corded remote | |||||
| 5.00Supply, installation, testing & commissioning of variable refrigerant volume modular type indoor units comprising of all accessories as per the specifications. The indoor units shall be suitable to work on cooling as well as heating mode.The indoor units shall be suitable for operation on 220 ±6% volts, 50Hz, 1 phase AC power supply. Ductable indoor units shall be suitable to handle extent of ductwork as shown in the design drawings and dehumidified air quantity as mentioned in the heat load summary sheet under "Special Conditions" and the indoor units shall be of following capacities. SITC of Indoor VRV/VRF Ceilling Mounted High Static Flow Type Duct Unit with Independent Vane Control & varibale air flow as per following nominal capacities complete with i) Expansion and mixing arrangements ii) Power Supply interconnections iii) Controlling interconections iv) Piping interconnections v) Supending accessories vi) Insulated Drain pipe line vii) Receiver Kit(Sensor) of Duct AC | |||||
| 5.01 | 4 way Cassette Type Units (1130 cfm/4HP)(nominal capacity) | 8 | Nos | 56,815 ₹4,54,520 | 49,560 ₹3,96,480 Lowest |
| 5.02 | 4 way Cassette Type Units (742 cfm/3.2HP)(nominal capacity) | 64 | Nos | 48,741 ₹31,19,424 | 47,790 ₹30,58,560 Lowest |
| 5.03 | 4 way Cassette Type Units (530 cfm/1.6HP)(nominal capacity) | 8 | Nos | 46,136 ₹3,69,088 | 46,020 ₹3,68,160 Lowest |
| 6.00 | Supply Installation Testing & Commissioning of corded remote controls as per drawing and specifications. | 80 | Nos | 6,554 ₹5,24,320 | 4,720 ₹3,77,600 Lowest |
Tender Value
₹2.3 Cr
EMD Value
₹4.5 L
Closing Date
1 Jun 2026, 2:00 pmClosed
Superintending Engineer
IPM Section, IIT Guwahati
Supply installation testing and commissioning of central VRV air-conditioning system and associated electrical works at 6th and 9th floor of RnD Building in IIT Guwahati Campus
2026_IITG_909230_1
IITG/IPM/NIT/C/2026-27/17
Open Tender
Electrical Works
Works
120 days
IIT Guwahati
Please refer tender document
2 documents required · 2 mandatory
₹5,000
Payable To IIT Guwahati
₹4.5 L
IPM Section
25 Jun 2026
19 May 2026
2 Jun 2026
19 May 2026
1 Jun 2026
19 May 2026
26 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Part A | |||||
| 2OUTDOOR UNIT | |||||
| 3Supply, installation, testing & commissioning of fully factory assembled Variable Refrigerant Volume type multi unit air-conditioning system inverter type complete with indoor and outdoor units with individual controller for cooling only operations. SITC of Variable Refrigerant Volume/Flow Outdoor Unit complete with hermitically sealed scroll compressor as per following nominal capacities complete with protective coated fins, mounting frame, casing, microproccessor panel, and other standard accessories : i) Microproccessor panel , ii) First charge of refirigerant R 410A or R407C , iii) Protective coated fins iv) Mounting frame with isolation pad , all required accessories, structural support and civil foundation. v) Interconnecting Pipes for Liquid, Discharge and Suction vi) Interconnecting Cables and Earthing from nearest given point, vii) Accumulator, viii) Specific Oil return system All Inverter Scroll Compressor(s) with variable refrigeration evaporating temperature enabled feature in outdoor unit capable of inverter control with 6 pole compressor motor. The inverter compressor should be capable of changing the speed in accordance to the variation in cooling or heating load requirement, back pressure control mechanism for efficient operation in low-load condition. The outdoor unit should be fitted with low noise, aero spiral design fan with minimum External Static Pressure of 75 Pa for easy discharge of Hot air, aero fitting grille, to reduce pressure loss. The outdoor unit should be capable of automatic refrigerant charge function. The heat exchanger shall be constructed with copper tubes mechanically bonded to aluminium fins to form a cross fin coil. The cost should be inclusive of Lifting, Shifting & Positioning of Outdoor Units to the installation platform | |||||
| 3.01 | Outdoor condensing Unit ( 60 HP) Nominal capacity | - | Nos | - | - |
| 4Indoor Units- All with corded remote | |||||
| 5Supply, installation, testing & commissioning of variable refrigerant volume modular type indoor units comprising of all accessories as per the specifications. The indoor units shall be suitable to work on cooling as well as heating mode.The indoor units shall be suitable for operation on 220 ±6% volts, 50Hz, 1 phase AC power supply. Ductable indoor units shall be suitable to handle extent of ductwork as shown in the design drawings and dehumidified air quantity as mentioned in the heat load summary sheet under "Special Conditions" and the indoor units shall be of following capacities. SITC of Indoor VRV/VRF Ceilling Mounted High Static Flow Type Duct Unit with Independent Vane Control & varibale air flow as per following nominal capacities complete with i) Expansion and mixing arrangements ii) Power Supply interconnections iii) Controlling interconections iv) Piping interconnections v) Supending accessories vi) Insulated Drain pipe line vii) Receiver Kit(Sensor) of Duct AC | |||||
| 5.01 | 4 way Cassette Type Units (1130 cfm/4HP)(nominal capacity) | - | Nos | - | - |
| 5.02 | 4 way Cassette Type Units (742 cfm/3.2HP)(nominal capacity) | - | Nos | - | - |
| 5.03 | 4 way Cassette Type Units (530 cfm/1.6HP)(nominal capacity) | - | Nos | - | - |
| 6Supply Installation Testing & Commissioning of corded remote controls as per drawing and specifications. | |||||
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.64 MB
NIT.pdf
Tender Documents • 0.84 MB
BOQ_955621.xls
BOQ • 0.42 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .