Loading…
Loading…
Tender Value
₹2.2 Cr
EMD Value
₹4.5 L
Closing Date
22 Jul 2026, 3:00 pm
Similar tender results from the same govt authority in the past 3 years.
Supply, installation, testing and commissioning of Telecom material in connection with Provision of CCTV cameras at Maksi, Shambhupura, Barayala Chaurasi, Dalauda, Nimbahera and Runija Goods Sheds.
C4_RTM_PA_26_01
C4_RTM_PA_26_01
Open
8 Months
Chittorgarh, Rajasthan
₹0
₹4.5 L
19 Jun 2026
19 Jun 2026
8 Jul 2026
Item Breakup - A-NS Items
Supply of 12 Core Metal Strengthened Outdoor Metre Unarmoured Optic Fibre Cable (ITUTG-652-D) and all the accessories required for installation, As Per latest TEC/BSNL Specification.
Supply of PVC insulated flexible 3 core x 2.5 Metre sq.mm multi strand power cable as per specification no. IS: 694:1990 reaffirmed 1995 or latest
Supply of CAT-6 cable of Dlink, Digisol, Metre Securenet,paramount, polycab make (with identificationmark/ferrules etc.)
Supply of Anti-Rodent Armoured CAT6 Cables Metre as per Technical specification attached. RATLAM DIVISION-COMMERCIAL/WESTERN RLY
Supply of Thermo shrink Universal Jointing kit Numbers for Quad Cable (for straight joints) as per RDSO spec IRS/TC-77/2012 revision 3 With latest Amd. Inspection by RDSO.
Supply of Thermo shrink Universal Jointing kit Numbers (TSF-1) for PIJF Cable (For 10/20 pair) as per RDSO Spec No RDSO/SPN/TC/57/2015, Rev.1, Amd.1 With latest Amd.
Supply of Half Round RCC pipes & collars of Numbers 150 mm internal dia (1 meter long) along with collars as per IS No. 458/2003 of NP type
Supply of Permanently Lubricated (PLB) High Metre density polyethylene (HDPE) Telecom duct for use as underground cable conduits -40/33 mm as per RDSO/SPN/TC/45/2013 Rev.2.0 amd 1 & 2 or latest amendments. Each km of HDPE duct should have 2 no End Plugs, 2 no Cable sealing plugs, and 2 no plastic couplers slip fit/push fit type.
Supply of RJ 45 Connector DAX, D-link, Digisol, Numbers 430.00 AE, Molex,Amphenol make as approved by Engineer in charge
Supply of PVC casing capping size 32mm Metre x12mm, conforming to IS 14927 Part-2 2001 or latest
Supply of White PVC Pipe of dia 1 Inch of as per Metre Standard IS:9537 (Part 3) with Pipe length of 3 mtrs each (Bend and Eblow as per site requirement will be supplied along with pipe)
Supply of OFC patch cord having SC/LC A P C Numbers 250.00 connector at one end SC/LC APC connector at another end as per site requirement(suitable for media converter/SFP suppIied)and length of patch cords 10 meters as per RDSO/SPN/TC/69/2007 rev.1.0 or latest as per instruction of engineering incharge
Supply of Media Converter [OFC to Ethernet] of Pair make D-Link or MROTEK or DAX or similar as per RDSO Spec No.RDSO/SPN/TC/103/2013 Rev 2.0 or latest.
Supply of Straight Joint Enclosures (SJC) Numbers complete with all accessories as per RDSO/SPN/TC/68/2025 Rev. 2.0 or latest for 48 fibers
Supply of 2 x 48 Fiber of 48 Fiber (SC/APC- Numbers SC/APC) FDMS, including splicing of OFC and termination ofall fibres using pig tail cable of standard size (All materials, including pig tails 1.5 meter minimum each) to be supplied by the contractor, this also includes arrangement & fixing of suitable metal box fixable in the wall for a spare OFC coil.
Supply of wireless router/ access point for WI-FI Numbers connectivity as per technical specification attached
Supply of manageable 8 Port POE+ switch Numbers speed 1000 Mbps with 2 SFP Ports (Total 10 Ports) loaded with SFP asper RDSO spec. No.RDSO/SPN/TC / 83/2020, Rev. 2.0 or latest {Trusted Telecom Portal (TTP) approval and compliance with other applicable regulatory guidelines, if any, are mandatory}.
Supply of full HD IP Colour camera Bullet type Numbers 156.00 as per RDSO spec. No: RDSO/SPN/TC/65/2021 Rev 6.0 or latest with amendment-1 or latest inspection by:- RDSO. With all required accessories as per instructions of the site in charge. RATLAM DIVISION-COMMERCIAL/WESTERN RLY
Supply Transportation to the site. Computer Table (1200 x 600x750) : 1 No. with block board & Sunmica top and Chair cushioned 2 Nos (Godrej make or similar) with all accessories and fixing materials to the Consignee store,and Transportation to the site. Note: One set includes one table and two chairs.
Supply of Fibre Distribution Management Numbers system (FDMS)/LIU for 12 Fiber complete with all accessories with patch cord & pigtail as per TEC Spec.GR/FDM/01/02April' 2007 or latest. This include supply of installation accessories.
Supply of Report generation device as per Numbers technical specification attached
Supply of IP phone as per technical Numbers specification attached, Compatible with existing systems. Accepted Make: Grandstream, FANVIL, Matrix
Supply of Network Attached Storage (NAS). Numbers Technical Specification attached
Supply of 64 Channel Network Video Recorder Numbers and 64TB storage after RAID 5/6 configuration with HDD (8 Nos of HDD, Capacity: 8 TB each must include), 2 nos Ethernet port complete with all other accessories as per RDSO spec. No. RDSO/SPN/TC/65/2021 Ver6.0 or latest, Clause No.10.2. The software licenses should be as per RDSO Spec No.: RDSO/SPN/TC/65/2021 Rev6.0 or Latest Clause 20.0.
Supply of minimum 512 GB SSD External Hard Numbers Disk ofreputed make with 3 years of warranty. Make: SONY/SEAGATE/SAMSUNG/WD
Supply of Iron cage for protection of Cameras Numbers 200.00 as per technical specifciation
Supply of Galvanized Iron Hot dipped Power Metre Coated Cable TRAY, Size W-100 mm, H-50 mm, 1.5 mm thick. Tray Material Specification should be as per EN ISO 1461 as per technical Specification
Supply of Remote Craft Terminal as per Numbers technical specification attached
Supply of Storage cabinet mode of 18 mm Numbers HDHMR board with single drawer unit with 10 mm top glass thickness with two door with locking arrangement (Size- W- 36" X D 18" X 36")
Maintenance Free Earth Electrode of length Numbers 3m, including supply of 3 bags of Earth enhancement material for earthling (10KGs /bag) for each electrode & other accessories as per Drg. No. SDO / RDSO/ E&B/001 and RDSO Spec No. RDSO / SPN/197/2008. Inspection by RDSO.
Double Walled Corrugated (DWC) HDPE Pipe Numbers with associated collars etc. as per RDSO Specification No.RDSO/SPN/204/2011 or latest anti-rodent & anti-oxidant and non-flame propagating type in 6 meters straight length and of size 120 mm outer die,& 103.5 mm inner dia Total 8495231.68 Item- 2 B1- NS Items Execution S No. Item Description of Item Unit Qty Rate Amount No RATLAM DIVISION-COMMERCIAL/WESTERN RLY
Excavation of the cable trench in hard soil Metre and/or Murrum soil mixed with boulders 300 mm wide at the bottom and 1.2 mtr deep or for less depth refilling the same with 1:3:6 CC.
Laying of half round RCC pipe after laying the Metre cables in the trenches. (Cable laying is covered separately)
Supply and installation of RCC pre-fabricated Numbers OFC jointing Pits as per DRG. No- RDSO/TCDO/COP-21 (a)/latest
Blowing of OFC through HDPE duct, where it is Metre not feasible to blow OFC due to curves, road/track crossings, bridges or for any other reason, OFC shall be drawn or laid manually as per standard procedure. In case OFC is to be laid adopting 'Direct in trench method then approval of competent authority will be taken before laying. OFC shall be supplied by the railway. Blowing/Laying shall be started from one end and each drum laying shall be monitored after blowing/laying and before leaving the site, trace/cable parameters for all the fiber/ conductors shall be taken from one central location by contractor's engineer with his own OTDR, optic talk set/measuring equipment's with Railway engineer. All the equipment's and machinery required shall be arranged by the contractor at his own cost
Laying of HDPE pipe as per approved cable Metre route plan in the excavated trench, taking due care while transporting and laying the same in the trenches or other protective works. Both the end of ducts should be sealed with end plugs before laying and should remain sealed till blowing is done
Splicing of fibres OFC Cable and making Splice Numbers 900.00 joint with contractor's own splicing machine (Rates are for single splice)
Wiring, drawing, fixing, laying and clipping of Metre all telecom cable/PVC Power cable in PVC pipe/duct/Casing caping with complete fitting as per the instruction of site Engineer
Supply & installation of 19" 9U rack with all Numbers accessories as per technical specification attached.
Supply, commissioning of 24 port managed POE Layer 2 Access network switch as per RDSO SPECIFICATION- RDSO/SPN/TC/83/2020 Rev 2.0 or latest. {Trusted Telecom Portal (TTP) approval and compliance with other applicable regulatory guidelines, if any, are mandatory}.
Supply, Commissioning of Full HD PTZ type IP Colour Camera along with 128 GB or Higher SD Card with accessories as per RDSO Spec No RDSO/SPN/TC /65/2021, Rev 6.0 or latest.
Installation, Testing & Commissioning of Full Numbers 156.00 HD IP Colour camera along with Mounting kit, as per RDSO spec. No: RDSO/SPN/TC/65/2021 Version 6.0 or latest with amendment-1 or latest. All the accessories and fixing materials required for this installation are to be supplied by contractor within the same cost RATLAM DIVISION-COMMERCIAL/WESTERN RLY
Supply, Installation, testing & commissioning of Numbers rack mountable 24 port manageable Layer -2 aggregate switch with 24 x GE SFP port and 4x 10GE SFP+ ports as per RDSO spec. No: RDSO/SPN/TC/65/202 1Version 6.0 with amendment-1 or latest Clause 14.0(i). All the accessories and fixing materials required for this installation are to be supplied by contractor within the same cost. {Trusted Telecom Portal (TTP) approval and compliance with other applicable regulatory guidelines, if any, are mandatory}.
Supply, Installation, testing & commissioning of Numbers Full HD/4K or higher large format display monitor (55"or higher) with HDMI Ports, complete with all accessories and HDMI cables, remote controller as per RDSO SPN No. RDSO/SPN/TC/65/2021, Rev 6.0 with amendment-1 or latest.
Supply, Installation, testing & commissioning of Numbers PC Workstation for Viewing cameras in multi- screen mode, Monitoring and System management and 4K UHD LED Monitor of 24 inch size along with 2 HDMI PORT in graphic card including all required licensed software's for VSS(like OS, MS Office, Anti-virus with 03 year's subscription), multifunction device for documentation, accommodate PC workstation & monitor with all accessories, spike buster (minimum 5 nos. 6A points with fuse), SOOVA UPS, Mounting Rack and other required materials as per RDSO spec. No: RDSO/SPN/TC/65/2021 Rev6.0 with amendment-1 or latest Clause No. 11.0.
Supply, Installation, testing & commissioning of Numbers Single mode 1G SFP module compatible to Layer-2, Aggregate & field switch Make: Syrotech, Cisco, Black Magic or similar as approved by engineer incharge.
Supply ,installation, testing and commissioning Numbers of ONT unit with 1 PON port& 4 RJ 45 Giga Ethernet, 802. eah, 1 x POTS (RJ 11) Ports, Wi- Fi, VLAN, IGMP, VoIP, QoS, auto discovery /Link detection, Dual Band as pertechnical specification attached.
Supply, Installation, Testing & Commissioning Numbers of 5 KVA online UPS with 120 minutes backup make: APC/Emerson/APLAB or similar as per Technical Specification attached.
Supply, Installation, Testing & Commissioning Numbers 200.00 of software (per camera basis) for video management and video recording with license as per RDSO spec. No: RDSO/SPN/TC/ 65/2021 Rev6.0 with amendment-1 or latest.
Supply, Installation, Testing & Commissioning Numbers of Digital keyboard (joystick) compatible with PTZ cameras as per RDSO spec. No: RDSO/SPN/TC/ 65/2021 Rev 6.0 with amendment-1 or latest.
Supply, Installation, Testing & Commissioning Numbers of 19" 42U Rack with all accessories like Electrical fitting, Fan tray, STP Patch Panel, cable manager, spike buster for housing IP storage unit . All the accessories and fixing materials required for this installation are to be supplied by contractor within the same cost RATLAM DIVISION-COMMERCIAL/WESTERN RLY
Installation, Testing, Wiring and Commissioning Numbers of 64 Channel Network Video Recorder and 64 TB storage after RAID 5/6 configuration. All the accessories and fixing materials required for this installation are to be supplied by contractor within the same cost.
Supply and installation of Electrical board with Numbers 3 nos of 6A/16A Socket,3 nos of 16A Switch, MCB and indicator for providing at Railway stations if required.
Supply and erection of 15 feet GI pipe of 4" dia, Numbers IS No: 1239 (Part1) 1990. Having iron base plate 10mm thick 30cm x 30cm welded at the bottom of pipe with 4 supports of iron bars of sizes 10mm dia. The 3 feet pipe shall be buried in the ground and 12 feet pipe shall be above the ground. The work includes digging of pit on platform, laying of cable in between poles in suitable underground GI pipes, erection of pole and filling the pit with 1:3:4 cement, concrete and sand. Final plastering should be done on the surface. The iron bracket on the top of the pole shall be provided to fix the CCTV camera and junction box.The work includes supply of all the material required in this item.
Supply & Installation of Weatherproof IP65/IP67 Numbers rated Location Box with all accessories as per technical specification attached
Floor/wall cutting and refilling the same, Metre including supply and laying of 25 mm PVC pipe ISI medium.
Supply, Installation, Testing & Commissioning Numbers of Graphical User Interface based Client software (per workstation basis) for workstation as per RDSO spec. No: RDSO/SPN/TC/ 65/2021 Rev6.0 with amendment-1 orlatest.
Fixing of tray for housing of all types of Metre telecom cable. (MS Clamp with all accessories required for fixing of tray are provided by the contractor)
Supply and installation FAT box fully loaded Numbers atleast 12 fiber as per technical specification attached
Supply of 8 Port FXS Gateway (DC or AC based Numbers as per site requirement) including mounting kit and all other accessories. Its standard installation would be as per technical specifications.
Supply and installation of RCC cable route Numbers marker engraved and painted on both side along the route every 50mm and route diversion as per Drg. No 4014/00/CC4 or latest/ Stone marker RATLAM DIVISION-COMMERCIAL/WESTERN RLY
Excavation of cable trench as per cable route cum plan, 1 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr wide advised by Engineer-in-charge alongside the track in normal (all type) soil/strata, conforming to distances as per cable route plan and refilling. This work includes clearing of route from bushes etc., covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately before covering by bricks. The work shall be done as per the extant practice on Western Railway and instructions of Railway Engineer at site. In case 1m depth of trench is not achievable due to site conditions, specific approval of JA grade officer will be required for each site where trench depth of 1m is not possible. Without the approval of JA Grade officer, no payment for trenching will be made for trench depth less than 1m
As and when required by the Engineer in Numbers 130.00 charge arranging /providing of labors for various safety related works such as protection of track etc. with contractors TandP, equipment, hand signal flags, spanners, hammers, etc. as per specification special conditions and detailed scope of work as urnished in the tender and directed by the engineer incharge. [Note:-Numbers to be read as Man-Days]
Placing of DWC/RCC pipes along with collars in Metre trenches at places of track and road crossings, platform cuttings etc. also for straight cable laying. (Cable laying is covered separately.). [Note:-Metre to be read as RM]
Installation Electrode for Maintenance Free Earth spec of RDSO/SPN/197/2008
Cement concrete work for miscellaneous items cum in the ratio 1: 3: 6. Item includes excavation, ramming, curing and plastering with cement & sand mixture (aggregate not exceeding 3.8 cm.) (Aggregate cement & sand to be supplied by the contractor)
Horizontal direction drilling/boring without Metre damage of surface road using Auger Machine/Manual. The bore shall be 150 mm dia & shallbe done at the depth of minimum 2000 mm from the groundlevel. The ground level shall be considered ignoring the bankheight of the bank of the road. The length of the bore shall beminimum 4 Mtrs long. this include insertion of different dia DWCpipe/ GI pipes coupling etc. as per direction of Engineer Incharge. Note:- Pipe will be supplied by railway. Contactor shallprovide all material required for boring and adequate nos. oflabours for proper laying of cables into the bore. Cable shall belaid cautiously so that it should not get damaged due to roughhandling & pressure on cable, Minimum Depth Of Cable 2 Metre. Total 13794235.65
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCCAmdandcorrectionslipDt110626.pdf
ATTACHMENT
GCCACS11of2026.pdf
ATTACHMENT
FirstSecondsheetDt110626.pdf
ATTACHMENT
SpecialConditionDt110626.pdf
ATTACHMENT
VariousformatDt110626.pdf
ATTACHMENT
TechnicalspecDt110626.pdf
ATTACHMENT
LatestSimilarNatureofWorkCCESirMar26.pdf Similar Nature 2026
ATTACHMENT
GCC2022.pdf
ATTACHMENT
TANEarthHQletterDt040725.pdf
ATTACHMENT
LatestSimilarNatureofWorkCCESirMar26.pdf
ATTACHMENT
Download all tender documents and submit your bid