Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.1 CrAdmitted-Finance GRAM AEMANPUR DISTRICT BULANDSHAHR UTTAR PRADESH | BULANDSHAHR | BULANDSHAHR | UTTAR PRADESH | ₹2.1 Cr | L1 | Admitted-Finance |
| 2 | L2₹2.5 Cr+₹39.3 L (18.9%)Admitted-Finance 248 1 CHHEDIPURWA STATION ROAD BEHIND GURU NANAK SCHOOL GONDA UTTAR PRADESH 271001 | GONDA | UTTAR PRADESH | 271001 | ₹2.5 Cr+₹39.3 L (18.9%) | L2 | Admitted-Finance |
| 3 | L3₹3.0 Cr+₹86.5 L (41.5%)Admitted-Finance | ₹3.0 Cr+₹86.5 L (41.5%) | L3 | Admitted-Finance |
| 4 | Rejected-Technical | - | - | Rejected-Technical TENDER CONDITION NOT QUALIFIED |
| 5 | Rejected-Technical 2 1433 D 6 KAMAL COLONY SAHARANPUR UP PIN 247001 | SAHARANPUR | UTTAR PRADESH | 247001 | - | - | Rejected-Technical TENDER CONDITION NOT QUALIFIED |
| Sl No | Description | Qty | Unit | M/S SMM INFRATECH PVT Ltd L2 | M/S S.P. & CO L3 | SINGH ENTERPRISES L1 |
|---|---|---|---|---|---|---|
| 1.00Safe loading & carriage including unloading & proper stacking of following store materials from ESC Hardoi/J.E. store to site of work. | ||||||
| 1.01 | S.T. Pole SP-55 Mtr. Long | 688 | No | 550 ₹3,78,400 | 560 ₹3,85,280 | 290 ₹1,99,520 Lowest |
| 1.02 | 25 KVA Transformer | 5 | No | 1,500 ₹7,500 | 4,800 ₹24,000 | 1,300 ₹6,500 Lowest |
| 1.03 | 11 KV M.S. Top Channel (100x50x6) 2240 mm | 91 | No | 100 ₹9,100 | 80 ₹7,280 Lowest | 100 ₹9,100 |
| 1.04 | 11 KV M.S. Dropper Channel (100x50x6) 2240 mm | 91 | No | 100 ₹9,100 | 80 ₹7,280 | 30 ₹2,730 Lowest |
| 1.05 | 11 kV Disc Insulator with fitting 45 KN | 300 | No | 50 ₹15,000 | 32 ₹9,600 | 8 ₹2,400 Lowest |
| 1.06 | Earthing Complete | 688 | No | 50 ₹34,400 | 32 ₹22,016 | 4 ₹2,752 Lowest |
| 1.07 | 11 kV (3 x 185) sqmm XLPE cable | 17,200 | Mtr. | 13 ₹2,23,600 | 32 ₹5,50,400 | 8 ₹1,37,600 Lowest |
| 1.08 | H.S. Cable jointing kit for 11 KV (3 x 185) sqmm cable Outdoor/Indoor type. | 344 | No | 100 ₹34,400 | 48 ₹16,512 Lowest | 90 ₹30,960 |
| 1.09 | 11 KV (3 x 185) sq mm straight through cable Jointing Kit. | 20 | No | 100 ₹2,000 | 48 ₹960 Lowest | 140 ₹2,800 |
Tender Value
₹4.8 Cr
EMD Value
₹4.8 L
Closing Date
27 Sept 2021, 5:00 pmClosed
SE, EDCH, MVVNL
SE, EDC, ASHA NAGAR, HARDOI(UP)
92/EDC(H)/2021-22
2021_MVVNL_617324_2
92/EDC(H)/2021-22
Open Tender
Miscellaneous Works
Item Rate
180 days
HARDOI
AS PER TENDER DOCUMENT
2 documents required · 2 mandatory
₹5,900
A/C No. 06597620000044, IFSC Code HDFC 0000659
₹4.8 L
23 Dec 2021
13 Sept 2021
28 Sept 2021
13 Sept 2021
27 Sept 2021
13 Sept 2021
Amount
Safe loading & carriage including unloading & proper stacking of following store materials from ESC Hardoi/J.E. store to site of work.
S.T. Pole SP-55 Mtr. Long
25 KVA Transformer
11 KV M.S. Top Channel (100x50x6) 2240 mm
11 KV M.S. Dropper Channel (100x50x6) 2240 mm
11 kV Disc Insulator with fitting 45 KN
Earthing Complete
11 kV (3 x 185) sqmm XLPE cable
H.S. Cable jointing kit for 11 KV (3 x 185) sqmm cable Outdoor/Indoor type.
11 KV (3 x 185) sq mm straight through cable Jointing Kit.
G.I. Pipe 160 mm
11 kV Fuse set
11 KV V type cross arm
H.S. Cable jointing kit for 33 kV (3 x 300) sqmm cable Outdoor/Indoor type
11 KV Pin insulator with GI pin
T off channel (100 x 50 x 6) 1300 mm
M.S. Angle (65 x 65 x 6) 2600 mm for brassing with 04 clamp
T/F Base angle set
ACSR Rabbit conductor
ACSR Dog conductor
X-arm holding clamp with bolt & nut
33 KV disc insulator B&S type 70 KN
Disc fitting 70 KN
Barbed wire
33 KV Stay set (20 X 1800) mm with stay wire, stay clamp, insulator , nut & bolt etc.
11 KV Stay set (16 X 1800) mm with stay wire, stay clamp, insulator , nut & bolt etc.
33 kV (3 x 300) sq mm XLPE cable
33 KV (3 x 300) sq mm straight through cable Jointing Kit.
M.S. Angle (65 x 65 x 6) 4300 mm for brassing with 04 clamp
33 KV V type cross arm
33 KV M.S. Top Channel (125x65x6) 3200 mm
33 KV M.S. Dropper Channel (125x65x6) 3000 mm
33 KV Pin insulators with G.I. Pin.
Fabrication & erection of single pole support for 33 KV line on 11 M long ST Pole with fixing of necessary clamp & other accessories like 1 no. Channel cross arm, Danger board, barbed wire etc. contractor shall provide, necessary clamps, F-Bracket etc. as per RESPO norms.
Fabrication, erection of single section pole for 33 KV line on 11 M long ST Pole with fixing of necessary clamps & other accessories like 1 no. top channel 125X65 mm - 2.24 M 1 no. Guarding Angle 2.5 mtr and No plate, danger board and barbed wire, installation of 4 no stay set included in this work etc.(all material arranged by contractor except steel & pole & insulators).as per RESPO norms.
Fabrication, erection of sectional double pole for 33 KV line on 11 M long ST Pole with fixing of necessary clamps & other accessories like 1 no. top channel 125X65 mm - 3.24 M 1 no. Guarding Angle 3.5 mtr and 3 X bracing, No plate, danger board and barbed wire, installation of 8 no stay set included in this work etc.(all material arranged by contractor except steel & pole & insulators).as per RESPO norms.
Fabrication, erection of tri pole for 33 KV line on 11 M long ST Pole with fixing of necessary clamps & other accessories like 2 no. top channel 100X50 mm - 3.24 M. 2 no. Guarding Angle and 3 X bracing etc one plate, danger board barbed wire etc.(all material arranged by contractor except steel & pole & insulators).as per RESPO norms.
Fabrication, erection of four pole for cable exposure for 33 kV line on 11 M. ST pole long with fixing of necessary clamps & other accessories like pin pin insulator and making bus bar complete .(all material arranged by contractor except steel & pole & insulators).as per RESPO norms.
Fabrication, erection, of end type double pole of with one side cable exposure for 33 KV line on 11 M long ST pole with fixing of necessary clamps & other accessories like disc insulator, 1 no. top channel 125×65 mm - 3.20M & 1 no. guarding angle and 1 no. X bracing, disc fittingits,33kv pin with pin insulator ,danger board, number plate, barbed wire, jumpering by PG clamp etc. (all material arranged by contractor except steel, insulator, disc insulator with fitting & pole).as per RESPO norms.
Conversion of existing 33 KV single pole support into section type double Double pole by fixing of 1 no top channel 125x65 mm of 3244 mm, 1 no guarding angle 3500 mm long 6 nos 33 KV disc fitting and disc insulator 24 no 3 no pin and 33 KV pin Insulator and other associated work grouting, painting and plinthing of new pole also include this work (all material arranged by contractor except steel & pole & insulators) as per RESPO norms.
Erection of single stud pole support on ST pole 11 M long with fixing of necessary clamps and other accessories required for erection.
Laying of 33 KV XLPE Cable.
Double circuit Cable laying in normal soil by digging of trench 1050 mm deep, 750 mm wide including supply of required material as fine sand, 1st class bricks, stone slab. Inter axial spacing between the two cable should be in between 0.25 m to 0.40m. the two cables should be separated by a partition of single bricks (All the material required for laying will be supplied by the contractor except 33 KV XLPE cable)
Stringing & sagging of three phase 33KV line on ACSR Dog conductor as per RESSPO Norms. (Conductor provided by the department. )
33 KV CABLE LAYING BY DRILL METHOD In HDPE pipe 160 mm dia
Hoisting of 33KV XLPE cable on double pole with MS pipe of size 6" dia 3 M long including its jumpering complete with clamps, nuts and bolts (Nut & Bolt arrange by the contractor).
Installation of 33 kV cable box 3x300 sq. mm outdoor/indoor
Installation of 33 kV cable box 3x300 sq. mm Straight Through Joint
Fabrication & erection of S/S type double pole for 11KV line on 11 M long ST pole with fixing of necessary clamps & other accessories like 1 no. top channel 100×50 mm,2 no.MS angle 65x65x6mm,danger board, number plate, barbed wire, D.O. fuse set.
Fabrication, erection of Single pole for 11 KV line on 11 M long ST Pole with fixing of necessary clamps & other accessories like 1 no. 11KV V-type Cross arm,1 no. Guarding Angle 65x65x6.
Fabrication, erection of double pole for end type terminations with one side cable exposure for 11 KV line on 11 M long ST Pole with fixing of necessary clamps & other accessories like 1 no. top channel 100X50 mm - 2.24 M. 1 no. Guarding Angle and X bracing etc.(all material arranged by contractor except steel & pole).as per RESPO norms.
Fabrication, erection of sectional double pole for 11 KV line on 11 M long ST Pole with fixing of necessary clamps & other accessories like 3 no. top channel 100X50 mm - 2.24 M 2 no. Guarding Angle and 3 X bracing etc.(all material arranged by contractor except steel & pole & insulators).as per RESPO norms.
Fabrication, erection of for conversion of existing single pole support into sectional double pole for 11 KV line on 11 M long ST Pole with grouting plinthing and painting of one ST pole in the alignment of existing pole fixing of necessary clamps & other accessories like 3 no. top channel 100X50 mm - 2.24 M 2 no. Guarding Angle and 3 X bracing etc.(all material arranged by contractor except steel & pole & insulators) necessary stay set shall be provided by contractor at his own cost. as per RESPO norms.
Erection of single stud pole support on ST pole 11 M long with fixing of necessary clamps and other accessories required for erection.
Fabrication, erection of four pole for cable exposure for 11 kV line on 11 M. ST pole long with fixing of necessary clamps & other accessories like pin insulator and making bus bar complete .(all material arranged by contractor except steel & pole & insulators).as per RESPO norms.
Stringing & sagging of three phase 11KV line on ACSR Rabbit conductor as per RESSPO Norms. (Conductor provided by the department.)
Laying of 11 KV XLPE Cable.
Double circuit cable laying in normal soil by digging of trench 1050 mm deep, 750 mm wide including supply of required material as fine sand, 1st class bricks, stone slab. Inter axial spacing between the two cable should be in between 0.25 m to 0.40m. the two cables should be separated by a partition of single bricks (All the material required for laying will be supplied by the contractor except 11 KV XLPE cable)
S/C Cable laying in normal soil by digging of trench 900 mm deep, 500 mm wide including supply of required material as fine sand, 1st class bricks, stone slab. (All the material required for laying will be supplied by the contractor except 11 KV XLPE cable)
Cable laying By drill method Single circuit
Laying of 11 KV XLPE Cable in HDPE pipe 160 mm dia by horizontal deep drilling method
Hoisting of 11KV XLPE cable3x185 sq mm on double pole with GI pipe of size 6" dia 3 M long including its jumpering complete with clamps, nuts and bolts(G.I. Pipe provided by Department).
Installation of cable box 11 kV 3x 185 sq mm outdoor/indoor
Installation of cable box 11 kV 3x 185 sq mm straight through Joint
High Pressure testing of 33 KV & 11 KV XLPE cable. Testing equipment will be arranged by the contractor.
33 KV cable
11 KV cable
LT WORK
Placement of 11/0.4 KV T/Fs on S/S Type D/P & installation, commissioning of 25/ KVA T/F including cost of L-pieces and lugs jumpering with the system WITH ELECTRODE EARTHING ( All the required material for above job shall be provided by contractor except T/Fs)
Installation of tell less fuse unit on D/P for 25 KVA T/F (Tell less fuse unit provided by contractor)
Nozeling, winding & grouting of stay set. (All the civil material & stay set will be arranged by the contractor except stay wire).
Fixing of earth rod (2500x20mm) as per norms. For earthing support of old existing poles of 33, 11 KV lines including 6 SWG GI/Earth wire. (earthing rod provided by department)
Grouting, Plinthing and Painting of new erected 11M long ST poles of single pole support, double pole cable exposures and end type poles of 11 &33 KV lines
Digging of Pit in kachcha/ Pakka land in depth upto 1/6 length of Pole, Dragging of STP from nearby place/Dump, Erection of Single pole along with stone pad in bottom with proper alignment of line for 33 KV line on 11 M long ST Pole and refilling with ramming of earth.
Grouting of pole in depth of 1/6 the length of pole in ratio 1:4:8 in cement sand and brick ballast as per RESPO norms.
Construction of pole plinth 300mm x 450 mm above ground level in 1:2:4 in cement, coarse sand and stone grit as per RESPO norms.
Painting of new erected ST pole with two coat of red oxide paint, PO red paint at top of pole 2 M & balance by two coats of best quality aluminium paint ISI of Burger/Nerolac/Asian mark as per norms.
Dismantling of 11KV line, L.T. lines & distribution boxes and its dump at suitable place on site up to completion of work and its safe loading/unloading/weighing carriage from dump site to je"s store/ESC daliganj (Except broken PCC Pole).
ST Pole 11 Mt Long/PCC pole
ACSR mix conductor
M/S SMM INFRATECH PVT Ltd
M/S S.P. & CO
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.06 MB
RTD92.pdf
Tender Documents • 0.42 MB
BOQ_960634.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .