| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.5 LAccepted-AOC BYE PASS DALHOUSIE ROAD PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹24.1 L+₹2.6 L (12.1%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹26.9 L+₹5.4 L (25.1%)Rejected-Finance 201 GANAPATI SANKUL AGASHIVNAGAR MALKAPUR KARAD SATARA MAHARASHTRA 415539 | SATARA | MAHARASHTRA | 415539 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹28.1 L+₹6.6 L (30.8%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹33.7 L+₹12.2 L (56.5%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
30 Sept 2023, 6:00 pmClosed
GE Satwari
GE Satwari Jammu
CLEANING AND PAINTING OF OH TANK REPAIR OF VALVES PIT CHAMBER FENCING OF PUMP HOUSES ETC UNDER AGE E/M OF GE SATWARI
2023_MES_614969_1
GEJM-54/2023-24
Open Tender
Civil Works
Item Rate
270 days
GE Satwari
D Class Cat a ii
9 documents required · 9 mandatory
₹500
GE Satwari
₹70,000
Yes
13 Nov 2023
31 Aug 2023
2 Oct 2023
31 Aug 2023
30 Sept 2023
15 Sept 2023
Amount
Material & Labour for cleaning of Over Head Tank (inside the tank/dume) and removed the deposited scales from the wall/surface of capacity one (1.0) Lakh Gallons with the help of wire mesh brush and vacum suction cleaners at the pressure not less than 50 to 80 bar including white wash the inner surfaces of wall (all side of dume/tank) complete all as specified and directed by Engineer-in-charge. Note: (i) Deposited sludge material inside the tank to be removed from the tank before white wash. (ii) All type of safety equipment and tool required at site rate deemed to be included in quoted rate.
All as per ser item No 01 her-in-before but of capacity 0.75 lakh Gallons
All as per ser item No 01 her-in-before but of capacity 0.50 lakh Gallons
All as per ser item No 01 her-in-before but of capacity 0.30 lakh Gallons
All as per ser item No 01 her-in-before but of capacity 0.10 lakh Gallons
All as per ser item No 01 her-in-before but of capacity 1.0 lakh Gallons underground sump
All as per ser item No 01 her-in-before but of capacity 0.75 lakh Gallons underground sump
All as per ser item No 01 her-in-before but of capacity 0.50 lakh Gallons underground sump
All as per ser item No 01 here-in-before but of capacity 0.20 lakh Gallons underground sump (Children school)
Material & Labour for scrabbing of outer side wall/surface with wire brush of Over Head Tank/dume incl colums of capacity one (1.0) Lakh Gallons for preparing the surfaces colour wash and applying two coats of cement based paint or as per existing clour complete all as specified and directed by Engineer-in-charge. Note: (i) Scrap material deposited plinth over tank to be removed away upto 50 mtr from tank. (ii) All type of safety equipment and tool required at site rate deemed to be included in quoted rate.
All as per ser item No 10 here-in-before but of capacity 0.75 lakh Gallons
All as per ser item No 10 here-in-before but of capacity 0.50 lakh Gallons
All as per ser item No 10 here-in-before but of capacity 0.30 lakh Gallons
All as per ser item No 10 here-in-before but of capacity 0.10 lakh Gallons
All as per ser item No 10 heer-in-before but of capacity 1.0 lakh Gallons underground sump
All as per ser item No 10 here-in-before but of capacity 0.75 lakh Gallons underground sump
All as per ser item No 10 here-in-before but of capacity 0.50 lakh Gallons underground sump
M&L for preparing painting and writing letters of "SAVE WATER" over the surface of over head tank in colour code "Blue" of size 36" x 18" and background over the surface of white painted on dome of RCC over head tank and under ground sump incl writing tank capacity, date of cleaning and due date of cleaning in capital letters of 80mm size on external surface of wall in white colour and back ground painted with black paint on the surfaces complete all as specified and directed by Engineer-in-charge.
Material and labour for applying synthetic enamel paint with one coat of spray painting of approved colour to header including connected acessories such as sluice valves (80mm to 200mm size), flanges, bends etc including marking inlet/outlet and area wise as per instruction by Engineer-in-charge complete including prepration of old painted surface complete all as specified and directed.
Material and labour for applying synthetic enamel paint with one coat of painting of approved colour to 150mm dia vertical CI/DI/MS pipe (incoming 02 Nos, outgoing 02 Nos and overflow/washout) each approx of 21 to 25 mtrs connected to OHT Reservoir including Ladder and railing of OHT, Water level meter stand with marking as per existing and connected acessories such as sluice valves (80mm to 200mm size), flanges, bends etc with marking inlet/outlet and area wise as per instruction by Engineer-in-charge complete including prepration of old painted surface complete all as specified and directed by Engineer-in-charge.
Material and labour for applying synthetic enamel paint with Two coat of spray painting of approved colour to Main gates and pillars of pump houses and writing "save water, save electricity, GE Satwari pump house Nos etc with marking as per instruction complete including prepration of old painted surface complete all as specified.
Supplying, fixing, jointing & testing DI pipes with flanged ends/ verticaliy cast class 'A' in any length 150mm bore laid for OHT rising, overflow, pumping,supply & washout etc including taking out old water mains complete all as specified and directed.
Description all as per ser item No 22 here-in-before of size 100 mm bore complete.
Supply and fixing upto 150 mm dia bore CI/DI special such as bends, tees collars tail pieces conforming to IS-9523 complete all as specified and directed.
S&F in replacement of integral LED Aviation light 25 Watts comprising of aluminium housing with polycarbonate enclosure including taking down old one.
S&F in replacement of Air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified.
S&F in replacement of Aluminium strip 25X3.15 mm with saddles and fixing screws etc for roof conductors above ground including taking down of old unsv strip.
S & F in repairs of test point terminal block made out of gun metal 75 mm x 75 mm x 25 mm drilled and screwed including three Nos 8mm dia 25 mm long hexagonal head screws and including provision of suitable MS box made out of 3 mm thick MS sheet to accommodate the terminal block all as directed including removing the old test point.
Supplying, laying in replacement, jointing & testing M S Pipes (ERW) heavy grade 80 mm bore with all fitting such as flange, bends, elbows, tees, short pieces etc laid in floors/rising main/supply distribution line including taking out old unserviceable,cracked MS tubing with all fittings complete all as specified and directed.
Description all as per Srl item No 29 here in before but for 100mm bore pipe
Description all as per Srl item No 29 here in before but for 150mm bore pipe
Supply only Orthotolidine (OT) solution in 500 ml bottle all as specified and directed.
Supply, fix, installation and testing (replacement) of ultra sonic non contact sensor for level monitoring for overhead tank with following specification:- Principal:- Ultrasonic sound waves water level sensing. O/P Port:- 4-20 ma/0-20 V, Data Transmitting out put port, SCADA Operation output port Range 8 Meters with anti theft device (micro controller based). Make: Unison/Crystal/Banner/As per OEM of automation panel.
M & L for servicing and testing of existing high torque motorize valve to make it functional with gears and adopters self lubricating type, weather proof with gears and adopters self lubricating type, weather proof with protection against, over voltage Jamming of valve and over current protection with manual by-pass arrangement to open/Close the valve on power failure having following features:- (a) Valve size:-150 RM, (b) Designed line pressure 4 Kg/sq cm (c) Operating angles:-90 degree, (d) Disc Material:- CI with nylon coating (e) Valve type:-Butterfly valve PN 1.0 with geared motor on top. (f) SCADA output pot., (g) Anti theft device micro controller based (h) Torque 35 Nm running time 13s, (i) Close off pressure 1200 KPA (j) Operating voltage 230 V AC with 2 in built auxiliary switches, IP 67 with control relay 24/12V & 2 Nos change over., Make: Belimo/ Leader/ Kirloskar
Description all as per Srl item No 34 here in before but for 100mm bore valve
Description all as per Srl item No 34 here in before but for 80mm bore valve
Supply & fixing on wall/ laying in ground 4 pair X 1.5 Sqmm PVC insulated & PVC copper armoured cable with heavy duty PVC Saddles 60 cm apart complete all as specied and directed.
Supply & fixing on wall/ laying in ground 6 pair X 1.5 Sqmm PVC insulated & PVC copper armoured cable with heavy duty PVC Saddles 60 cm apart complete all as specied and directed.
Supply and fixing in replacement of Intellegent panel meter 415 Volts 50 HZ of size 96x96mm
Supply and laying in replacement of PVC insulated, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 4 sqmm 2 core conforming to ISI marked fixed it to wall including testing and commissioning complete. All as directed by Engr-in-Charge.
Supply, Installing, testing and commissioning of motor controls enclosure indoor type, floor mounted with overall size not less than 1.2 mx 1.0 m x 0.45 m , fabricated out of 2.0 mm thick CRCA sheet steel and front & back door openable type and suitable for operation on 415 Volts, 50 HZ, AC supply and accessories as below complete with pad locking sealing arrangement, earthing stud labelling, painting, interconnections, providing of danger plates and internal wirring etc. as per specifications. The panel shall be placed over pedestals in PCC (1:3:6) height 150mm above floor level complete all as specified and directed including the following accessories and taking down old unserviceable panel with accessories :- (Note - MCCB/FASD starter shall be measured and paid separately )
S & F in replacement of MCCB 250 Amps 4 pole 415V 3 phase 50 HZ, of breaking capacity 36 KA with adjustable thermal & adjustable magnetic setting complete all as specified and directed.
S & F in replacement of MCCB 160 Amps 4 pole 415V 3 phase 50 HZ, of breaking capacity 36 KA with adjustable thermal & adjustable magnetic setting complete all as specified and directed. .
S & F in replacement of MCCB 100 Amps 3 pole 415V 3 phase 50 HZ of breaking capacity 16 KA with adjustable thermal & adjustable magnetic setting. complete all as specified.
S & F in replacement of MCCB 63 Amps 3 pole 415V 3 phase 50 HZ of breaking capacity 16 KA with fixed type complete all as specified.
S & F in replacement of MCCB 160 Amps 3 pole 415V 3 phase 50 HZ, of breaking capacity 36 KA with adjustable thermal & adjustable magnetic setting complete all as specified and directed.
S & F in replacement of MCCB 80/100 Amps 3 pole 415V 3 phase 50 HZ, of breaking capacity 25 KA with Fixed type complete all as specified and directed.
S & F in replacement of MCCB 40/63 Amps 3 pole 415V 3 phase 50 HZ of breaking capacity 16 KA with with Fixed type complete all as specified and directed.
Material and Labour for earthing complete with galvanised mild steel earthh plate electrode of size 600mm x 600mm x6mm thick buried dirctly in ground earth (in vertical) earth pit not less than 2.25 mtr below ground level with top edge of plate not less than 1.5 mtr below ground level connected to Galvanised iron earth strip of size 32mm x 6mm by means of nut, bolt,check nuts and washer of galvanised iron including PCC pit in PCC 1:2:4 type B-1, 50mm thick pre-cast RCC 1:2:4 type B-1 cover slab using reinforcement with XPM weighing not less than 1.87 kg/Sqm with suitable handle made of 12mm end bar,including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one end fixed with cast iron funnel and wire mesh 40mm bore light grade galvanized steel tubing upto 5m length for earth pre protection ,common salt, charcoal, etc complete as shown in electrical plate No 3 of SSR Part-l and testing on completion.
Supply, Installing, testing and commissioning of motor controls enclosure indoor type, floor mounted with overall size not less than 0.9mx 0.6m x 0.45m, fabricated out of 2.0 mm thick CRCA sheet steel and front & back door openable type and suitable for operation on 415 Volts, 50 HZ, AC supply and accessories as below complete with pad locking sealing arrangement, earthing stud labelling, painting, interconnections, providing of danger plates and internal wirring etc. as per specifications. The panel shall be placed over pedestals in PCC (1:3:6) height 150mm above floor level complete all as specified and directed including the following accessories and taking down old unserviceable panel with accessories :-
S&F in repair 80 mm bore sluice valve of CI body, both ends flanged duly drilled, ISI marked with IS-14846-2000, PN-1.6 having Stainless Steel spindle and check nut including operating wheel cap, fixing with new nuts, bolts, washers and rubber insertion/ packing complete all as directed for the following sizes :-
All as per item No 56 above here-in-before but of size 100 mm bore
All as per item No 56 above here-in-before but of size 150mm bore
All as per item No 56 above here-in-before but of size 200mm bore
S&F in repair 150mm bore non rerurn (NRV) sluice valve of CI body, both ends flanged duly drilled, ISI marked with IS-14846-2000, PN-1.6 having Stainless Steel spindle and check nut including operating wheel cap, fixing with new nuts, bolts, washers and rubber insertion/ packing steel plate as required complete all as specified and directed.
All as per item No 60 above here-in-before of size 100 mm bore
All as per item No 60 above here-in-before of size 80mm bore
M&L for replacement of Single phase preventer suitable for upto 40 HP 3 Phase 415V Pump set complete all as specified and directed.
M&L for repairs to unserviceable star delta starter for pump set 40 HP by replacing over load relay of suitable range coil, spare kit for contactor, terminals, short pieces of copper wire duly crimped with bottle lugs etc and any other spares as required for proper functioning and monitoring of pump set (Model of starter ML 3F) all as specified and directed.
All as per Sl item No 64 here-in-before but for 30/35 HP capacity (Model of starter ML 1.5)
All as per Sl item No 64 here-in-before but for 20 /25HP capacity
All as per Sl item No 64 here-in-before but for 15 HP capacity
Surface dressing not exe 15 cm deep and getting out in hard/ dense soil / hard core including removing the excavated grass /weeds/hard cement concrete / stone etc. and leveling neatly the excavated area for Pump House yards/OHT/UG Sump Area etc complete all as specified and directed by Engineer-in-charge. Note:- (i) The rate shall be deemed to be included the cost of removing the grass, weeds, debris, excess soil etc to a distance not less than 500m and keeping the excavated surface clean and leveled all as directed. (ii) During the surface cleaning any damage the existing services like HT/LT UG cable, Telephone wire, pipe line and sewage line etc will be repaired by the contractor, rate deeemed to be included in quoted rate. ( Rate considered average soft/loose & hard dense soil)
Demolition of cement concrete or any type incl removal complete all as specified and directed.
M&L for concrete type D2 1:4:8 with 40 mm graded aggregate for foundation of cable duct & panel and repair for foot path at Pump house bldg etc all as specified & as directed
M&L Plain cement concrete, type B1, mix 1:2:4 (with 20mm graded stone aggregates) as in coping, benching, bed plates, bed for tanks & other similar including weathering, slightly rounded or chamfered edges and throating including necessary form work all as specified and as directed.
S&F in repairs of OHT stairs steel work in hand rails, wind ties, posts and struts in stairs screwed or welded to shape as directed including all necessary drilling holes, notching for stair rails bolting or riveting etc and similar work confirming to Fe-290 Gde E-165 completed all as specified and as directed by the Engineer-in-charge.
Supply and fixing in replacement of steel chequered plate of thickness 6mm for cable duct cover in Pump house Bldg duly painted on all sides with two coats of black synthetic enamel paint over a coat red oxide primer all as specified & as directed.
Supply and laying Chequerred Rubber Mat 2mtrx1mtr length 2.5mm thick complete all as specified and directed. Make:Jyothi ISI mark or its equivalent
Repair & maintenance of existing cable duct with of size 600mm x 600mm for using PCC concrete1:3:6 type C-1, 80 mm thick using 20 mm graded stone aggregate in existing floor 230 mm thick brick wall in cement mortar 1:4 including breaking of floor, excavation and earth work complete finished with 15 mm thick CM 1:4 plaster and 6 mm thick MS chequred plate duct cover including lifting arrangement, angle iron 25 x 25 mm fixed on both side edge of duct and cross angle 40 x 40 on duct over 80 mm inside duct for rest of cable on 1 Mtr distance and two coat of synthetic enameled paint over a coat red oxide on steel surface.
All as per item No 75 above here-in- before of size 450 x 600 mm cross section
Dismantling the existing valve pit of any size or type complete.
Material and labour for construction of one brick thich (23 cm) masonary valve pit built in cement mortar 1:4 of size 150cm x 120cm x150cm (internal dimension) over 15cm thick PCC 1:3:6 type C-2 sub base extended allround 15cm beyond external edge of brick work including plastering 15mm thick in cement mortar 1:6 internally and flush pointing to brick wall surfaces externally as work proceeds complete with MS sheet cover 10 SWG with handle,angle iron frame 40mm x 40mm x 6mm (grouting with anchor fasteners length not less than 15cm - 04 Nos) locking arrangement and painting as per colour code complete all as specified and directed by Engr-in-Charge. (Rate quoted by the tenderer shall deemed to be included the cost of extra excavation and earth work).
Description all as per Srl item No 78 here in before but of size 120cm x 90cm x 120cm (internal dimension).
Taking down the existing sluice valve for repair/maintenance of size 80mm bore and refacing, regrinding and refixing incl minor replacement of unserviceable parts i.e spindle, seat, body/bonnet connection/wedgeor disc/seat ring complete all as specified and directed by Engineer-in-charge.
Description all as per Srl item No 80 here in before but for iron pipe of 100mm bore
Description all as per Srl item No 80 here in before but for iron pipe of 150mm bore
Description all as per Srl item No 80 here in before but for iron pipe of 200mm bore
M & L for welding the existing leakage of GI /MS/DI Pipe line any size laid in trenches header's along with overhead in vertical position by using electric welding machine & welding electrode complete all as directed by Engr-in-charge. Note :Earth work should be deemed to be included in the quoted rate.
Testing of water by the approved govt lab authority and test the following parameters of water:- PH range, Total solids, Total hardness, Floride, Nitrites, Lead arsenic, Ammonia, Chlorides, Cadminum, Cyanide, Mercury Iron, Management sulphate, Phemolic and submission the report to Department or as directed by Engineer-in-charge. Note: (i) Water sample collected on the presence of Medical staff or MES staff, the empty sample collection bottle will be provide by the contractor rate deemed to be included in the quoted rate. (ii) Water will be collected all pump houses/tube well. (iii) Water sample will be collect every quater and test report submitted by the contractor.
S&F integral solar aviation LED light comprising of aluminium housing with polycarbonate enclosure, lighting colour: Red, Input Voltage: 180 - 280V AC 0r 40 - 58V DC, IP66 rating including taking down old one from OHT reservior of 30 Mtr Height. Make:- Geltronix, Bajaj, Crompton
Excavating in any type of soil for post holes (or similar holes) each n exc. 0.5 cum. Getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm.watering and removing surplus soil to a distance n. exc. 50 metre and making good surface.
M&L for Cement concreteType D2 1:4:8 (40 mm graded ) in foundations, filling and mass concrete complete all as specified.
M&L for Cement concreteType B2 1:2:4 (40 mm graded ) in foundations, filling and mass concrete complete all as specified.
M&L Mild steel posts and struts in n fencing including cutting tops to shape as directed, drilling holes, notching for wires etc flat iron fillets ( for screwing wire mesh etc ) including all necessary dirilling, bolting or riveting etc and similar work conforming to Fe-290 Gde E-165,all as specified and directed by Engr-in-charge.
M&L Mild steel screw bolts(machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, 11 to 15 mm dia, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long.
S&F galvanized, 2 strand, steel barbed wire 2.24mm dia, barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossings with and provision of galvanized mild steel wire, staples or steel pins, etc as directed.
Fixing only Chain link fencing including line wires, any mesh, size & type to any type of standards, rails,fixed with RCC Columns,RCC Posts and struts in fencing including drilling holes bolting, straining blots, etc. including provision of binding wire.
Supply only MS galvanished chain link fencing.
Supply and fixing MS Round bars fix in chain link fencing using 0.90 mm dia GI wire as strengthing bar.
Supply and fabricated and fixing in replacement of MS clamp suitable for 100 mm dia colum pipe made for 150 X 10 mm thick plate including bolts/ nuts and washers of required size complete all as specified and directed.
M & L for Developmewnt of tube well upto 300 Mtr depth with air compressor not less then 400 PSI compressor/ over pumping unit till sand free water obtained and testing the yield for duration (a) For first 08 Hrs by using air compressure sand free (b) If ist 08 hours sand not free, then subsequent hours beyound 08 hrs increase as per directed by Engineer-in-charge all as specified. (Note: (i) All type of T & P and transportation required shall be arranged by the contractor him self and rate for the same will be deemed to included the qoated rate. (ii) Contractor has to provide own DG set /Prime mover to run compressure at site.
Supply and fixing cast iron air valves single air out lets 50 mm dia bore and fixing up to ductile iron water supply mains (with cap) complete with bolts, nuts, rubber washers insertions etc duly ISI marked confirming to IS-780, flanged end for water mains complete all as specified and directed
Material and labour in replacement of GATE TOP LIGHT MONACO decorative LED 3000K 10W fixture, aluminium die casting, transperent glass diffuser, black colour IP-43 complete inluding fixing using metal sleeve anchor fastners and bolts of suitable size incl PCC work and electrical connection as per nearest bldg or pole to be fixed complete all as specified and directed.
BMMJ TRADERS AND ENGINEERS
Prakash Trading Corporation
G M ENGINEERING SERVICES
M/S S K Electricals Regd
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .